{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,19]],"date-time":"2026-01-19T12:09:52Z","timestamp":1768824592111,"version":"3.49.0"},"reference-count":49,"publisher":"MDPI AG","issue":"21","license":[{"start":{"date-parts":[[2023,11,5]],"date-time":"2023-11-05T00:00:00Z","timestamp":1699142400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"National Key R &amp; D Program of China","award":["2020YFC2005405"],"award-info":[{"award-number":["2020YFC2005405"]}]},{"name":"National Key R &amp; D Program of China","award":["B18001"],"award-info":[{"award-number":["B18001"]}]},{"DOI":"10.13039\/501100013314","name":"111 Project","doi-asserted-by":"publisher","award":["2020YFC2005405"],"award-info":[{"award-number":["2020YFC2005405"]}],"id":[{"id":"10.13039\/501100013314","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100013314","name":"111 Project","doi-asserted-by":"publisher","award":["B18001"],"award-info":[{"award-number":["B18001"]}],"id":[{"id":"10.13039\/501100013314","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Vancomycin (VAN), a glycopeptide antibiotic, is the preferred therapeutic agent for treating Gram-positive bacteria. Rapid and precise quantification of VAN levels in cerebrospinal fluid (CSF) and plasma is crucial for optimized drug administration, particularly among elderly patients. Herein, we introduce a novel clinical test strip utilizing colloidal gold competitive immunoassay technology for the expedient detection of VAN. This test strip enables the detection of VAN concentrations in clinical samples such as plasma within 10 min and has a limit of detection of 10.3 ng\/mL, with an inhibitory concentration 50% (IC50) value of 44.5 ng\/mL. Furthermore, we used the test strip for pharmacokinetic analysis of VAN in the CSF and plasma of beagle dogs. Our results provide valuable insights into the fluctuations of the drug concentration in the CSF and plasma over a 24 h period after a single intravenous dose of 12 mg\/kg. The test strip results were compared with the results obtained via liquid chromatography\u2013mass spectrometry methods, and the measured VAN concentrations in the CSF and plasma via both of the methods showed excellent agreement.<\/jats:p>","DOI":"10.3390\/s23218978","type":"journal-article","created":{"date-parts":[[2023,11,5]],"date-time":"2023-11-05T07:35:06Z","timestamp":1699169706000},"page":"8978","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Rapid Colloidal Gold Immunoassay for Pharmacokinetic Evaluation of Vancomycin in the Cerebrospinal Fluid and Plasma of Beagle Dogs"],"prefix":"10.3390","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3862-6143","authenticated-orcid":false,"given":"Yechang","family":"Guo","sequence":"first","affiliation":[{"name":"School of Integrated Circuits, Peking University, Beijing 100871, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shaofeng","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Engineering and Technology, China University of Geosciences (Beijing), Beijing 100083, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3370-2936","authenticated-orcid":false,"given":"Peiyue","family":"Li","sequence":"additional","affiliation":[{"name":"School of Integrated Circuits, Peking University, Beijing 100871, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pan","family":"Zhang","sequence":"additional","affiliation":[{"name":"School of Integrated Circuits, Peking University, Beijing 100871, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Integrated Circuits, Peking University, Beijing 100871, China"},{"name":"National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Beijing 100871, China"},{"name":"Beijing Advanced Innovation Center for Integrated Circuits, Beijing 100871, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2023,11,5]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"796","DOI":"10.1111\/bcp.12596","article-title":"Adverse drug reactions in special populations\u2014The elderly","volume":"80","author":"Davies","year":"2015","journal-title":"Br. J. Clin. Pharmacol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"2679","DOI":"10.1021\/acssensors.0c01318","article-title":"Wearable Electrochemical Sensors for the Monitoring and Screening of Drugs","volume":"5","author":"Teymourian","year":"2020","journal-title":"ACS Sens."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1111\/ner.12467","article-title":"Best Practices for Intrathecal Baclofen Therapy: Troubleshooting","volume":"19","author":"Saulino","year":"2016","journal-title":"Neuromodulation"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1128\/AAC.01818-17","article-title":"Impact of Real-Time Therapeutic Drug Monitoring on the Prescription of Antibiotics in Burn Patients Requiring Admission to the Intensive Care Unit","volume":"62","author":"Fournier","year":"2018","journal-title":"Antimicrob. Agents Chemother."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1016\/j.mayocp.2015.01.016","article-title":"Drug management in the elderly adult with chronic kidney disease: A review for the primary care physician","volume":"90","author":"Ponticelli","year":"2015","journal-title":"Mayo Clin. Proc."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"631","DOI":"10.1038\/ja.2014.111","article-title":"Glycopeptide antibiotics: Back to the future","volume":"67","author":"Butler","year":"2014","journal-title":"J. Antibiot."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1021\/cr030103a","article-title":"Glycopeptide and lipoglycopeptide antibiotics","volume":"105","author":"Kahne","year":"2005","journal-title":"Chem. Rev."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"7751","DOI":"10.1002\/jcb.28049","article-title":"FtsA as a cidal target for Staphylococcus aureus: Molecular docking and dynamics studies","volume":"120","author":"Ragunathan","year":"2019","journal-title":"J. Cell. Biochem."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"e45","DOI":"10.1164\/rccm.201908-1581ST","article-title":"Diagnosis and Treatment of Adults with Community-acquired Pneumonia. An Official Clinical Practice Guideline of the American Thoracic Society and Infectious Diseases Society of America","volume":"200","author":"Metlay","year":"2019","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Chattaweelarp, T., Changpradub, D., Punyawudho, B., Thunyaharn, S., and Santimaleeworagun, W. (2020). Is Early Monitoring Better? Impact of Early Vancomycin Exposure on Treatment Outcomes and Nephrotoxicity in Patients with Methicillin-Resistant Staphylococcus aureus Infections. Antibiotics, 9.","DOI":"10.3390\/antibiotics9100672"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/j.cca.2018.11.037","article-title":"Measurement of urinary matrix metalloproteinase-7 for early diagnosis of acute kidney injury based on an ultrasensitive immunomagnetic microparticle-based time-resolved fluoroimmunoassay","volume":"490","author":"Liang","year":"2019","journal-title":"Clin. Chim. Acta"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1143","DOI":"10.1007\/s40265-017-0764-7","article-title":"The Whole Price of Vancomycin: Toxicities, Troughs, and Time","volume":"77","author":"Jeffres","year":"2017","journal-title":"Drugs"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/j.jare.2019.10.005","article-title":"Vancomycin resistant Staphylococcus aureus infections: A review of case updating and clinical features","volume":"21","author":"Cong","year":"2020","journal-title":"J. Adv. Res."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"3987","DOI":"10.1002\/jssc.202000691","article-title":"Simultaneous separation and determination of vancomycin and its crystalline degradation products in human serum by ultra high performance liquid chromatography tandem mass spectrometry method and its application in therapeutic drug monitoring","volume":"43","author":"Fan","year":"2020","journal-title":"J. Sep. Sci."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1295","DOI":"10.4155\/bio-2020-0112","article-title":"A whole blood microsampling assay for vancomycin: Development, validation and application for pediatric clinical study","volume":"12","author":"Moorthy","year":"2020","journal-title":"Bioanalysis"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.jchromb.2014.01.035","article-title":"A simple quantitative method analysing amikacin, gentamicin, and vancomycin levels in human newborn plasma using ion-pair liquid chromatography\/tandem mass spectrometry and its applicability to a clinical study","volume":"951\u2013952","author":"Bijleveld","year":"2014","journal-title":"J. Chromatogr. B Analyt. Technol. Biomed. Life Sci."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/j.cca.2014.12.012","article-title":"Novel LC-MS\/MS method for plasma vancomycin: Comparison with immunoassays and clinical impact","volume":"441","author":"Oyaert","year":"2015","journal-title":"Clin. Chim. Acta"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1016\/S0731-7085(98)00095-8","article-title":"A modified HPLC method for the determination of vancomycin in plasma and tissues and comparison to FPIA (TDX)","volume":"18","author":"Farin","year":"1998","journal-title":"J. Pharm. Biomed. Anal."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"614","DOI":"10.1186\/s40064-015-1411-y","article-title":"ELISA-based detection of gentamicin and vancomycin in protein-containing samples","volume":"4","author":"Odekerken","year":"2015","journal-title":"Springerplus"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"3895","DOI":"10.1021\/acssensors.2c01910","article-title":"Optimization of Vancomycin Aptamer Sequence Length Increases the Sensitivity of Electrochemical, Aptamer-Based Sensors In Vivo","volume":"7","author":"Shaver","year":"2022","journal-title":"ACS Sens."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"21622","DOI":"10.1039\/D1RA03681E","article-title":"Catalysis of electro-oxidation of antibiotics by nitroxyl radicals and the electrochemical sensing of vancomycin","volume":"11","author":"Ono","year":"2021","journal-title":"RSC Adv."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Eguchi, H., Hatano, A., and Yoshimi, Y. (2021). Reagentless Sensing of Vancomycin Using an Indium Tin Oxide Electrode Grafted with Molecularly Imprinted Polymer including Ferrocenyl Group. Sensors, 21.","DOI":"10.3390\/s21248338"},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Aaryashree, A., Takeda, Y., Kanai, M., Hatano, A., Yoshimi, Y., and Kida, M. (2020). A \u201cSingle-Use\u201d Ceramic-Based Electrochemical Sensor Chip Using Molecularly Imprinted Carbon Paste Electrode. Sensors, 20.","DOI":"10.3390\/s20205847"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Tan, F., Zhai, M., Meng, X., Wang, Y., Zhao, H., and Wang, X. (2021). Hybrid peptide-molecularly imprinted polymer interface for electrochemical detection of vancomycin in complex matrices. Biosens. Bioelectron., 184.","DOI":"10.1016\/j.bios.2021.113220"},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Blidar, A., Feier, B., Pusta, A., Dr\u0103gan, A.-M., and Cristea, C. (2019). Graphene\u2013Gold Nanostructures Hybrid Composites Screen-Printed Electrode for the Sensitive Electrochemical Detection of Vancomycin. Coatings, 9.","DOI":"10.3390\/coatings9100652"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"3834","DOI":"10.1002\/jsfa.9605","article-title":"Development of a multicomponent immunochromatographic test system for the detection of fluoroquinolone and amphenicol antibiotics in dairy products","volume":"99","author":"Hendrickson","year":"2019","journal-title":"J. Sci. Food Agric."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"2223","DOI":"10.1002\/jsfa.8032","article-title":"Colloidal gold-McAb probe-based rapid immunoassay strip for simultaneous detection of fumonisins in maize","volume":"97","author":"Yao","year":"2017","journal-title":"J. Sci. Food Agric."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"5109","DOI":"10.3390\/s130405109","article-title":"Performance improvement of the one-dot lateral flow immunoassay for aflatoxin B1 by using a smartphone-based reading system","volume":"13","author":"Lee","year":"2013","journal-title":"Sensors"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1007\/s00216-017-0714-y","article-title":"A multiplex immunochromatographic test using gold nanoparticles for the rapid and simultaneous detection of four nitrofuran metabolites in fish samples","volume":"410","author":"Wang","year":"2018","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Li, Y., Liu, L., Song, S., Kuang, H., and Xu, C. (2018). A Rapid and Semi-Quantitative Gold Nanoparticles Based Strip Sensor for Polymyxin B Sulfate Residues. Nanomaterials, 8.","DOI":"10.3390\/nano8030144"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1016\/j.toxicon.2018.05.015","article-title":"Rapid detection of aflatoxin B(1) in medicinal materials of radix and rhizome by gold immunochromatographic assay","volume":"150","author":"Hu","year":"2018","journal-title":"Toxicon"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"9580","DOI":"10.1039\/C8RA01116H","article-title":"Development of an immunochromatographic lateral flow strip for the simultaneous detection of aminoglycoside residues in milk","volume":"8","author":"Sun","year":"2018","journal-title":"RSC Adv."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"4214","DOI":"10.3390\/s130404214","article-title":"Rapid and highly sensitive detection of lead ions in drinking water based on a strip immunosensor","volume":"13","author":"Kuang","year":"2013","journal-title":"Sensors"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"16680","DOI":"10.1038\/s41598-018-35080-5","article-title":"A Lateral Flow Immunochromato-graphic Strip Test for Rapid Detection of Oseltamivir Phosphate in Egg and Chicken Meat","volume":"8","author":"Yang","year":"2018","journal-title":"Sci. Rep."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1016\/j.foodchem.2018.10.047","article-title":"A colorimetric paper-based sensor for toltrazuril and its metabolites in feed, chicken, and egg samples","volume":"276","author":"Wang","year":"2019","journal-title":"Food Chem."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/j.saa.2017.11.045","article-title":"Utilization of a lateral flow colloidal gold immunoassay strip based on surface-enhanced Raman spectroscopy for ultrasensitive detection of antibiotics in milk","volume":"197","author":"Shi","year":"2018","journal-title":"Spectrochim. Acta A Mol. Biomol. Spectrosc."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"4869","DOI":"10.1002\/jsfa.9686","article-title":"Specific antigen-based and emerging detection technologies of mycotoxins","volume":"99","author":"Rahman","year":"2019","journal-title":"J. Sci. Food Agric."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1016\/j.bios.2015.04.049","article-title":"Development of ELISA and colloidal gold immunoassay for tetrodotoxin detetcion based on monoclonal antibody","volume":"71","author":"Ling","year":"2015","journal-title":"Biosens. Bioelectron."},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Ling, S., Xiao, S., Xie, C., Wang, R., Zeng, L., Wang, K., Zhang, D., Li, X., and Wang, S. (2018). Preparation of Monoclonal Antibody for Brevetoxin 1 and Development of Ic-ELISA and Colloidal Gold Strip to Detect Brevetoxin 1. Toxins, 10.","DOI":"10.3390\/toxins10020075"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/j.foodchem.2018.03.087","article-title":"Colloidal gold-based immunochromatographic strip assay for the rapid detection of three natural estrogens in milk","volume":"259","author":"Wang","year":"2018","journal-title":"Food Chem."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1080\/09540105.2017.1293014","article-title":"Development of ic-ELISA and lateral-flow immunochromatographic assay strip for the detection of vancomycin in raw milk and animal feed","volume":"28","author":"Kong","year":"2017","journal-title":"Food Agric. Immunol."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"763686","DOI":"10.3389\/fchem.2021.763686","article-title":"Rapid Monitoring of Vancomycin Concentration in Serum Using Europium (III) Chelate Nanoparticle-Based Lateral Flow Immunoassay","volume":"9","author":"Bian","year":"2021","journal-title":"Front. Chem."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1002\/rcm.246","article-title":"Rapid bioanalysis of vancomycin in serum and urine by high-performance liquid chromatography tandem mass spectrometry using on-line sample extraction and parallel analytical columns","volume":"15","author":"Cass","year":"2001","journal-title":"Rapid Commun. Mass Spectrom."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1111\/jvim.15357","article-title":"Parenterally administered vancomycin in 29 dogs and 7 cats (2003-2017)","volume":"33","author":"DeStefano","year":"2019","journal-title":"J. Vet. Intern. Med."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"2090","DOI":"10.1016\/j.xphs.2020.03.012","article-title":"New Insights Into the Pharmacokinetics of Vancomycin After Oral and Intravenous Administration: An Investigation in Beagle Dogs","volume":"109","author":"Sauter","year":"2020","journal-title":"J. Pharm. Sci."},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"Barshevskaya, L.V., Sotnikov, D.V., Zherdev, A.V., and Dzantiev, B.B. (2023). Modular Set of Reagents in Lateral Flow Immunoassay: Application for Antibiotic Neomycin Detection in Honey. Biosensors, 13.","DOI":"10.3390\/bios13050498"},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Lai, S., Liu, Y., Fang, S., Wu, Q., Fan, M., Lin, D., Lin, J., and Feng, S. (2023). Ultrasensitive detection of SARS-CoV-2 antigen using surface-enhanced Raman spectroscopy-based lateral flow immunosensor. J. Biophotonics, 16.","DOI":"10.1002\/jbio.202300004"},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"Renzi, E., Piper, A., Nastri, F., Merkoci, A., and Lombardi, A. (2023). An Artificial Miniaturized Peroxidase for Signal Amplification in Lateral Flow Immunoassays. Small, e2207949.","DOI":"10.1002\/smll.202207949"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1038\/nmeth.2089","article-title":"NIH Image to ImageJ: 25 years of image analysis","volume":"9","author":"Schneider","year":"2012","journal-title":"Nat. Methods"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/21\/8978\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T21:17:47Z","timestamp":1760131067000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/21\/8978"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,5]]},"references-count":49,"journal-issue":{"issue":"21","published-online":{"date-parts":[[2023,11]]}},"alternative-id":["s23218978"],"URL":"https:\/\/doi.org\/10.3390\/s23218978","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,5]]}}}