{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T02:43:05Z","timestamp":1760150585397,"version":"build-2065373602"},"reference-count":24,"publisher":"MDPI AG","issue":"23","license":[{"start":{"date-parts":[[2023,11,25]],"date-time":"2023-11-25T00:00:00Z","timestamp":1700870400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"State Grid science and technology project","award":["5400-202255292A-2-0-QZ"],"award-info":[{"award-number":["5400-202255292A-2-0-QZ"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>High-voltage electric field measurement technology has certain applications in electric field measurement of power systems, but due to the limitation of its measurement accuracy and bandwidth, it cannot be used for the measurement of lightning-impulse voltage. In order to calibrate the nonlinearity of the MV-level lightning-impulse voltage measurement system, this paper proposes the design and implementation of a high-precision inductive wideband electric field measuring sensor (EFMS). The influence of the metal shell on the electric field distribution was simulated, and the influence of the electric field non-uniformity coefficient was studied. The characteristics of the EFMS were tested, and the results showed that the EFMS can accurately reproduce the waveform of lightning-impulse voltage and power-frequency voltage, with a proportionality coefficient of 0.05664 V\/(kV\/m). In mostly uniform and extremely non-uniform fields, the nonlinearity of the EFMS for impulse voltage is less than \u00b10.25%, and the nonlinearity of the EFMS for power-frequency voltage is less than 0.1%. It is shown that the EFMS can be used for the nonlinearity calibration of ultra-high voltage impulse measurement devices.<\/jats:p>","DOI":"10.3390\/s23239409","type":"journal-article","created":{"date-parts":[[2023,11,27]],"date-time":"2023-11-27T03:48:17Z","timestamp":1701056897000},"page":"9409","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Development of a Wideband Precision Electric Field Measuring Sensor"],"prefix":"10.3390","volume":"23","author":[{"given":"Zhaozhi","family":"Long","sequence":"first","affiliation":[{"name":"School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China"},{"name":"China Electric Power Research Institute, Beijing 100192, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Feng","family":"Zhou","sequence":"additional","affiliation":[{"name":"China Electric Power Research Institute, Beijing 100192, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fuchang","family":"Lin","sequence":"additional","affiliation":[{"name":"School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiawei","family":"Fan","sequence":"additional","affiliation":[{"name":"China Electric Power Research Institute, Beijing 100192, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wenting","family":"Li","sequence":"additional","affiliation":[{"name":"China Electric Power Research Institute, Beijing 100192, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yinglong","family":"Diao","sequence":"additional","affiliation":[{"name":"China Electric Power Research Institute, Beijing 100192, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kangmin","family":"Hu","sequence":"additional","affiliation":[{"name":"China Electric Power Research Institute, Beijing 100192, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2023,11,25]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Schon, K. (2013). High Impulse Voltage and Current Measurement Techniques: Fundamentals\u2013Measuring Instruments\u2013Measuring Methods, Springer.","DOI":"10.1007\/978-3-319-00378-8"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Harada, T., Wakimoto, T., Sato, S., and Saeki, M. (1999, January 23\u201327). Development of national standard class reference divider for impulse voltage measurements. Proceedings of the 11th International Symposium on High Voltage Engineering, London, UK.","DOI":"10.1049\/cp:19990496"},{"key":"ref_3","unstructured":"Meisner, J., Passon, S., Schierding, C., Hilbert, M., and Kurrat, M. (2017, January 15\u201317). PTB\u2019s new standard impulse voltage divider for traceable calibrations up to 1 MV. Proceedings of the 20th International Symposium on High Voltage Engineering, Paris, France."},{"key":"ref_4","first-page":"1826","article-title":"Device of 1200 kV wideband capacitive divider based on high-voltage standard capacitor","volume":"48","author":"Long","year":"2022","journal-title":"High Volt. Eng."},{"key":"ref_5","unstructured":"Wakimoto, T., and Ishii, M. (2007, January 27\u201331). National standard class measuring system for impulse voltage in Japan. Proceedings of the XVth International Symposium on High Voltage Engineering, Ljubljana, Slovenia."},{"key":"ref_6","first-page":"1","article-title":"Review of research advances and fronts on international lightning and protection","volume":"41","author":"Zeng","year":"2015","journal-title":"High Volt. Eng."},{"key":"ref_7","first-page":"1893","article-title":"Review of high voltage ratio standard devices technology","volume":"47","author":"Lei","year":"2021","journal-title":"High Volt. Eng."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1605","DOI":"10.1109\/TIM.2016.2540999","article-title":"Uncertainty evaluation of the waveform parameters of 1-kV low-impedance impulse voltage calibrator","volume":"65","author":"Ren","year":"2016","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"115007","DOI":"10.1063\/1.5031910","article-title":"Design and performance of a wideband precision capacitive divider for AC and impulse voltage measurement","volume":"89","author":"Long","year":"2018","journal-title":"Rev. Sci. Instrum."},{"key":"ref_10","first-page":"2964","article-title":"Variation law of spatial electric field during the development of streamer under positive switching impulse voltage","volume":"45","author":"Lv","year":"2019","journal-title":"High Volt. Eng."},{"key":"ref_11","unstructured":"International Electrotechnical Commission (2010). IEC60060-2 High-Voltage Test Techniques\u2013Part 2: Measuring Systems, IEC."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"2904","DOI":"10.1109\/TPAS.1984.318292","article-title":"A potential free spherical sensor for the measurement of transient electric fields","volume":"103","author":"Feser","year":"1984","journal-title":"IEEE Trans. PAS"},{"key":"ref_13","first-page":"16","article-title":"Measurement of transient electric field in substations using a spherical three-dimensional electric field probe","volume":"29","author":"Wang","year":"2002","journal-title":"J. North China Electr. Power Univ."},{"key":"ref_14","first-page":"7","article-title":"Research on Fiber Optic Transient EFMS","volume":"23","author":"Zhang","year":"2004","journal-title":"Meas. Control. Technol."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Schutte, A., and Rodrigo, H. (1999, January 23\u201327). Transient phenomena due to disconnect switching in high voltage substations. Proceedings of the IEEE Eleventh International Symposium on High Voltage Engineering, London, UK.","DOI":"10.1049\/cp:19990556"},{"key":"ref_16","first-page":"857","article-title":"Distortion-free Measurement of High Impulse Voltages","volume":"3","author":"Feser","year":"1988","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1109\/41.3117","article-title":"A remote sensor for the three components of transient electric fields","volume":"35","author":"Thomson","year":"1988","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_18","first-page":"661","article-title":"Experience with the detection of faulty composite insulators on high-voltage power lines by the electric field measurement method","volume":"13","author":"Carignan","year":"1998","journal-title":"IEEE Trans."},{"key":"ref_19","first-page":"1641","article-title":"Design of an electro-optic integrated electric field sensor","volume":"46","author":"Chen","year":"2006","journal-title":"J. Tsinghua Univ. (Sci. Technol.)"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1109\/TDEI.2011.5704523","article-title":"Design and application of an integrated electro-optic sensor for intensive electric field measurement","volume":"18","author":"Zeng","year":"2011","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1109\/TIE.2018.2826455","article-title":"Transient Voltage Measurements for Overhead Transmission Lines and Substations by Metal-Free and Contactless Integrated Electro-Optic Field Sensors","volume":"66","author":"Wang","year":"2019","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1436","DOI":"10.1088\/0957-0233\/5\/12\/003","article-title":"A device for the X-Y measurement of electric Fields","volume":"5","author":"Ramirez","year":"1994","journal-title":"Meas. Sci. Tech."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Chekurov, Y., and H\u00e4llstr\u00f6m, J.K. (July, January 27). Fast resistive attenuators for high accuracy measurements of LI voltages. Proceedings of the 2004 Conference on Precision Electromagnetic Measurements, London, UK.","DOI":"10.1109\/CPEM.2004.305598"},{"key":"ref_24","doi-asserted-by":"crossref","unstructured":"Kuhnke, M., Werle, P., Schl\u00fcterbusch, T.C., and Meisner, J. (2020, January 18\u201330). Investigation on new sensors for a contactless impulse voltage measurement. Proceedings of the 2020 IEEE Conference on Electrical Insulation and Dielectric Phenomena, Virtual.","DOI":"10.1109\/CEIDP49254.2020.9437382"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/23\/9409\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T21:30:20Z","timestamp":1760131820000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/23\/23\/9409"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,25]]},"references-count":24,"journal-issue":{"issue":"23","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["s23239409"],"URL":"https:\/\/doi.org\/10.3390\/s23239409","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2023,11,25]]}}}