{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,6]],"date-time":"2026-05-06T00:53:16Z","timestamp":1778028796656,"version":"3.51.4"},"reference-count":37,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2023,12,28]],"date-time":"2023-12-28T00:00:00Z","timestamp":1703721600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Sedentary behaviors and low physical activity among hospitalized patients have detrimental effects on health and recovery. Wearable activity monitors are a promising tool to promote mobilization and physical activity. However, existing devices have limitations in terms of their outcomes and validity. The Activ8 device was optimized for the hospital setting. This study assessed the concurrent validity of the modified Activ8. Hospital patients performed an activity protocol that included basic (e.g., walking) and functional activities (e.g., room activities), with video recordings serving as the criterion method. The assessed outcomes were time spent walking, standing, upright, sedentary, and newly added elements of steps and transfers. Absolute and relative time differences were calculated, and Wilcoxon and Bland\u2013Altman analyses were conducted. Overall, the observed relative time differences were lower than 2.9% for the basic protocol and 9.6% for the functional protocol. Statistically significant differences were detected in specific categories, including basic standing (p &lt; 0.05), upright time (p &lt; 0.01), and sedentary time (p &lt; 0.01), but they did not exceed the predetermined 10% acceptable threshold. The modified Activ8 device is a valid tool for assessing body postures, motions, steps, and transfer counts in hospitalized patients. This study highlights the potential of wearable activity monitors to accurately monitor and promote PA among hospital patients.<\/jats:p>","DOI":"10.3390\/s24010180","type":"journal-article","created":{"date-parts":[[2023,12,28]],"date-time":"2023-12-28T09:35:21Z","timestamp":1703756121000},"page":"180","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Validation of the Activ8 Activity Monitor for Monitoring Postures, Motions, Transfers, and Steps of Hospitalized Patients"],"prefix":"10.3390","volume":"24","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0251-5089","authenticated-orcid":false,"given":"Marlissa L.","family":"Becker","sequence":"first","affiliation":[{"name":"Physical Therapy, Department of Orthopaedics and Sports Medicine, Erasmus MC, University Medical Center Rotterdam, 3000 CA Rotterdam, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5400-7345","authenticated-orcid":false,"given":"Henri L. P.","family":"Hurkmans","sequence":"additional","affiliation":[{"name":"Physical Therapy, Department of Orthopaedics and Sports Medicine, Erasmus MC, University Medical Center Rotterdam, 3000 CA Rotterdam, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jan A. N.","family":"Verhaar","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Sports Medicine, Erasmus MC, University Medical Center Rotterdam, 3000 CA Rotterdam, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Johannes B. J.","family":"Bussmann","sequence":"additional","affiliation":[{"name":"Department of Rehabilitation Medicine, Erasmus MC, University Medical Center Rotterdam, 3000 CA Rotterdam, The Netherlands"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2023,12,28]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1368","DOI":"10.1016\/j.apmr.2020.11.012","article-title":"Levels of Physical Activity and Sedentary Behavior During and After Hospitalization: A Systematic Review","volume":"102","author":"Kirk","year":"2021","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"1660","DOI":"10.1111\/j.1532-5415.2009.02393.x","article-title":"The underrecognized epidemic of low mobility during hospitalization of older adults","volume":"57","author":"Brown","year":"2009","journal-title":"J. Am. Geriatr. Soc."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Tasheva, P., Kraege, V., Vollenweider, P., Roulet, G., M\u00e9an, M., and Marques-Vidal, P. (2020). Accelerometry assessed physical activity of older adults hospitalized with acute medical illness\u2014An observational study. BMC Geriatr., 20.","DOI":"10.1186\/s12877-020-01763-w"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1046\/j.1532-5415.2003.51152.x","article-title":"Loss of independence in activities of daily living in older adults hospitalized with medical illnesses: Increased vulnerability with age","volume":"51","author":"Covinsky","year":"2003","journal-title":"J. Am. Geriatr. Soc."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1093\/ageing\/afaa103","article-title":"Changes in muscle strength and physical function in older patients during and after hospitalisation: A prospective repeated-measures cohort study","volume":"50","author":"Hartley","year":"2020","journal-title":"Age Ageing"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"123","DOI":"10.7326\/M14-1651","article-title":"Sedentary time and its association with risk for disease incidence, mortality, and hospitalization in adults: A systematic review and meta-analysis","volume":"162","author":"Biswas","year":"2015","journal-title":"Ann. Intern. Med."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1823","DOI":"10.1111\/jan.13958","article-title":"Systematic review and meta-analysis of experimental studies: In-hospital mobilization for patients admitted for medical treatment","volume":"75","author":"Cortes","year":"2019","journal-title":"J. Adv. Nurs."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1486","DOI":"10.1111\/jocn.12315","article-title":"Outcomes of inpatient mobilization: A literature review","volume":"23","author":"Kalisch","year":"2014","journal-title":"J. Clin. Nurs."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"4661","DOI":"10.1111\/jan.14954","article-title":"Systematic review of interventions targeting fundamental care to reduce hospital-associated decline in older patients","volume":"77","author":"Cummins","year":"2021","journal-title":"J. Adv. Nurs."},{"key":"ref_10","unstructured":"WHO Regional Office for Europe, The European Observatory on Health Systems and Policies, Rafferty, A.M., Busse, R., Zander-Jentsch, B., Sermeus, W., and Bruyneel, L. (2019). Strengthening Health Systems through Nursing: Evidence from 14 European Countries, World Health Organization. Regional Office for Europe."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1186\/s13643-021-01843-x","article-title":"Barriers and enablers to physical activity in patients during hospital stay: A scoping review","volume":"10","author":"Geelen","year":"2021","journal-title":"Syst. Rev."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1080\/09638288.2018.1492636","article-title":"\u201cI\u2019m not going to walk, just for the sake of walking\u2026\u201d: A qualitative, phenomenological study on physical activity during hospital stay","volume":"42","author":"Koenders","year":"2018","journal-title":"Disabil. Rehabil."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1097\/PHM.0000000000000185","article-title":"Barriers to early mobility of hospitalized general medicine patients: Survey development and results","volume":"94","author":"Hoyer","year":"2015","journal-title":"Am. J. Phys. Med. Rehabil."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"e11819","DOI":"10.2196\/11819","article-title":"Consumer-based wearable activity trackers increase physical activity participation: Systematic review and meta-analysis","volume":"7","author":"Brickwood","year":"2019","journal-title":"JMIR mHealth uHealth"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1136\/bjsports-2020-102892","article-title":"Do smartphone applications and activity trackers increase physical activity in adults? Systematic review, meta-analysis and metaregression","volume":"55","author":"Laranjo","year":"2021","journal-title":"Br. J. Sports Med."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"e192","DOI":"10.2196\/jmir.3469","article-title":"Behavior change techniques implemented in electronic lifestyle activity monitors: A systematic content analysis","volume":"16","author":"Lyons","year":"2014","journal-title":"J. Med. Internet Res."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"e6540","DOI":"10.2196\/mhealth.6540","article-title":"Feasibility and effectiveness of using wearable activity trackers in youth: A systematic review","volume":"4","author":"Ridgers","year":"2016","journal-title":"JMIR mHealth uHealth"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"397","DOI":"10.3109\/07853890.2013.810891","article-title":"Effect of \u2018activity monitor-based\u2019counseling on physical activity and health-related outcomes in patients with chronic diseases: A systematic review and meta-analysis","volume":"45","author":"Vaes","year":"2013","journal-title":"Ann. Med."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/j.pmrj.2010.12.022","article-title":"Early mobilization in critically ill patients: Patients\u2019 mobilization level depends on health care provider\u2019s profession","volume":"3","author":"Ryan","year":"2011","journal-title":"Pm R."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1591","DOI":"10.2522\/ptj.20100018","article-title":"Walking speed threshold for classifying walking independence in hospitalized older adults","volume":"90","author":"Graham","year":"2010","journal-title":"Phys. Ther."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1123\/japa.2014-0115","article-title":"Very Low Levels of Physical Activity in Older Patients During Hospitalization at an Acute Geriatric Ward: A Prospective Cohort Study","volume":"23","author":"Villumsen","year":"2015","journal-title":"J. Aging Phys. Act."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1123\/japa.2014-0190","article-title":"A review of the accuracy and utility of motion sensors to measure physical activity of frail, older hospitalized patients","volume":"24","author":"McCullagh","year":"2016","journal-title":"J. Aging Phys. Act."},{"key":"ref_23","first-page":"9230081","article-title":"Validation of Two Activity Monitors in Slow and Fast Walking Hospitalized Patients","volume":"2022","author":"Pedersen","year":"2022","journal-title":"Rehabil. Res. Pr."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1233","DOI":"10.1177\/0269215519836454","article-title":"Measuring physical activity levels in hospitalized patients: A comparison between behavioural mapping and data from an accelerometer","volume":"33","author":"Valkenet","year":"2019","journal-title":"Clin. Rehabil."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"van Dijk-Huisman, H.C., Bijnens, W., Senden, R., Essers, J.M.N., Meijer, K., Aarts, J., and Lenssen, A.F. (2021). Optimization and validation of a classification algorithm for assessment of physical activity in hospitalized patients. Sensors, 21.","DOI":"10.3390\/s21051652"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1186\/s12984-019-0594-9","article-title":"Detection of body postures and movements in ambulatory adults with cerebral palsy: A novel and valid measure of physical behaviour","volume":"16","author":"Claridge","year":"2019","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Fanchamps, M.H.J., Horemans, H.L.D., Ribbers, G.M., Stam, H.J., and Bussmann, J.B.J. (2018). The accuracy of the detection of body postures and movements using a physical activity monitor in people after a stroke. Sensors, 18.","DOI":"10.3390\/s18072167"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1123\/jmpb.2019-0038","article-title":"Validation of a Clinically Feasible Activity Monitor Which Measures Body Postures and Movements in Adults With Lower-Limb Amputation Who Wear a Prosthesis","volume":"3","author":"Horemans","year":"2020","journal-title":"J. Meas. Phys. Behav."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1249\/JES.0000000000000206","article-title":"A Framework to Evaluate Devices That Assess Physical Behavior","volume":"47","author":"Keadle","year":"2019","journal-title":"Exerc. Sport Sci. Rev."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1267","DOI":"10.3390\/s140101267","article-title":"Recommendations for standardizing validation procedures assessing physical activity of older persons by monitoring body postures and movements","volume":"14","author":"Lindemann","year":"2014","journal-title":"Sensors"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"277","DOI":"10.2522\/ptj.20100159","article-title":"Evaluation of a Body-Worn Sensor System to Measure Physical Activity in Older People With Impaired Function","volume":"91","author":"Taraldsen","year":"2011","journal-title":"Phys. Ther."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"57","DOI":"10.3138\/ptc.2016-61","article-title":"Physical activity of ICU survivors during acute admission: Agreement of the activPAL with observation","volume":"70","author":"Baldwin","year":"2018","journal-title":"Physiother. Can."},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Kirk, A.G., Kimmel, L.A., Behm, K.J., Peiris, C.L., and Ekegren, C.L. (2022). Validity of the ActivPAL and ActiGraph for measuring sitting time and steps in hospitalised orthopaedic patients with altered weight bearing. Disabil. Rehabil., 1\u20139.","DOI":"10.1080\/09638288.2022.2157896"},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Valkenet, K., and Veenhof, C. (2019). Validity of three accelerometers to investigate lying, sitting, standing and walking. PLoS ONE, 14.","DOI":"10.1371\/journal.pone.0217545"},{"key":"ref_35","first-page":"2055668319890535","article-title":"The Activ8 activity monitor: Validation of posture and movement classification","volume":"7","author":"Horemans","year":"2020","journal-title":"J. Rehabil. Assist. Technol. Eng."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1177\/0269215517724850","article-title":"Validity and reliability of accelerometry in identification of lying, sitting, standing or purposeful activity in adult hospital inpatients recovering from acute or critical illness: A systematic review","volume":"32","author":"Anderson","year":"2018","journal-title":"Clin. Rehabil."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"160018","DOI":"10.1038\/sdata.2016.18","article-title":"The FAIR Guiding Principles for scientific data management and stewardship","volume":"3","author":"Wilkinson","year":"2016","journal-title":"Sci. Data"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/1\/180\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T21:43:20Z","timestamp":1760132600000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/1\/180"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,28]]},"references-count":37,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,1]]}},"alternative-id":["s24010180"],"URL":"https:\/\/doi.org\/10.3390\/s24010180","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,12,28]]}}}