{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T00:33:35Z","timestamp":1760142815021,"version":"build-2065373602"},"reference-count":41,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2024,1,2]],"date-time":"2024-01-02T00:00:00Z","timestamp":1704153600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"National Science and Technology Council of Taiwan","award":["111-2221-E-011-020-MY2"],"award-info":[{"award-number":["111-2221-E-011-020-MY2"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>For ultrasound multi-angle plane wave (PW) imaging, the coherent PW compounding (CPWC) method provides limited image quality because of its conventional delay-and-sum beamforming. The delay-multiply-and-sum (DMAS) method is a coherence-based algorithm that improves image quality by introducing signal coherence among either receiving channels or PW transmit angles into the image output. The degree of signal coherence in DMAS is conventionally a global value for the entire image and thus the image resolution and contrast in the target region improves at the cost of speckle quality in the background region. In this study, the adaptive DMAS (ADMAS) is proposed such that the degree of signal coherence relies on the local characteristics of the image region to maintain the background speckle quality and the corresponding contrast-to-noise ratio (CNR). Subsequently, the ADMAS algorithm is further combined with minimum variance (MV) beamforming to increase the image resolution. The optimal MV estimation is determined to be in the direction of the PW transmit angle (Tx) for multi-angle PW imaging. Our results show that, using the PICMUS dataset, TxMV-ADMAS beamforming significantly improves the image quality compared with CPWC. When the p value is globally fixed to 2 as in conventional DMAS, though the main-lobe width and the image contrast in the experiments improve from 0.57 mm and 27.0 dB in CPWC, respectively, to 0.24 mm and 38.0 dB, the corresponding CNR decreases from 12.8 to 11.3 due to the degraded speckle quality. With the proposed ADMAS algorithm, however, the adaptive p value in DMAS beamforming helps to restore the CNR value to the same level of CPWC while the improvement in image resolution and contrast remains evident.<\/jats:p>","DOI":"10.3390\/s24010262","type":"journal-article","created":{"date-parts":[[2024,1,2]],"date-time":"2024-01-02T03:33:33Z","timestamp":1704166413000},"page":"262","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Improvement in Multi-Angle Plane Wave Image Quality Using Minimum Variance Beamforming with Adaptive Signal Coherence"],"prefix":"10.3390","volume":"24","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4542-4195","authenticated-orcid":false,"given":"Che-Chou","family":"Shen","sequence":"first","affiliation":[{"name":"Department of Electrical Engineering, National Taiwan University of Science and Technology, Taipei 106335, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chun-Lin","family":"Huang","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, National Taiwan University of Science and Technology, Taipei 106335, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2024,1,2]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1177\/016173469902100402","article-title":"Time-resolved pulsed elastography with ultrafast ultrasonic imaging","volume":"21","author":"Sandrin","year":"1999","journal-title":"Ultrason. Imaging"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1109\/MM.2011.65","article-title":"Medical ultrasound imaging: To GPU or not to GPU?","volume":"31","author":"So","year":"2011","journal-title":"IEEE Micro"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1109\/TUFFC.2014.2882","article-title":"Ultrafast imaging in biomedical ultrasound","volume":"61","author":"Tanter","year":"2014","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1109\/TUFFC.2009.1067","article-title":"Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography","volume":"56","author":"Montaldo","year":"2009","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"13386","DOI":"10.1038\/s41598-022-16961-2","article-title":"Improving plane wave ultrasound imaging through real-time beamformation across multiple arrays","volume":"12","author":"Foiret","year":"2022","journal-title":"Sci. Rep."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1983","DOI":"10.1109\/TUFFC.2018.2865504","article-title":"High spatial\u2013temporal resolution reconstruction of plane-wave ultrasound images with a multichannel multiscale convolutional neural network","volume":"65","author":"Zhou","year":"2018","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"2010","DOI":"10.1109\/TMI.2018.2809641","article-title":"Deep neural networks for ultrasound beamforming","volume":"37","author":"Luchies","year":"2018","journal-title":"IEEE Trans. Med. Imag."},{"key":"ref_8","first-page":"1","article-title":"Plane-wave image reconstruction via generative adversarial network and attention mechanism","volume":"70","author":"Tang","year":"2021","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"592","DOI":"10.1109\/TUFFC.2021.3127916","article-title":"Complex convolutional neural networks for ultrafast ultrasound imaging reconstruction from in-phase\/quadrature signal","volume":"69","author":"Lu","year":"2022","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1326","DOI":"10.1109\/TUFFC.2022.3152689","article-title":"Improving image quality for single-angle plane wave ultrasound imaging with convolutional neural network beamformer","volume":"69","author":"Lu","year":"2022","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1606","DOI":"10.1109\/TUFFC.2007.431","article-title":"Adaptive beamforming applied to medical ultrasound imaging","volume":"54","author":"Synnevag","year":"2007","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1868","DOI":"10.1109\/TUFFC.2009.1263","article-title":"Benefits of minimum-variance beamforming in medical ultrasound imaging","volume":"56","author":"Synnevag","year":"2009","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"2187","DOI":"10.1109\/TUFFC.2009.1301","article-title":"Beamspace adaptive beamforming for ultrasound imaging","volume":"56","author":"Nilsen","year":"2009","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"2381","DOI":"10.1109\/TUFFC.2010.1706","article-title":"Eigenspace-based minimum variance beamforming applied to medical ultrasound imaging","volume":"57","author":"Asl","year":"2010","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"996","DOI":"10.1016\/j.ultras.2012.07.012","article-title":"Eigenspace-based minimum variance beamformer combined with Wiener postfilter for medical ultrasound imaging","volume":"52","author":"Zeng","year":"2012","journal-title":"Ultrasonics."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1912","DOI":"10.1109\/TMI.2012.2208469","article-title":"Eigenspace based minimum variance beamforming applied to ultrasound imaging of acoustically hard tissues","volume":"31","author":"Mehdizadeh","year":"2012","journal-title":"IEEE Trans. Med. Imag."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1440","DOI":"10.1109\/TUFFC.2014.006934","article-title":"Plane wave compounding based on a joint transmitting-receiving adaptive beamformer","volume":"62","author":"Zhao","year":"2015","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Rindal, O.M.H., and Austeng, A. (2016, January 18\u201321). Double adaptive plane-wave imaging. Proceedings of the 2016 IEEE International Ultrasonics Symposium, Tours, France.","DOI":"10.1109\/ULTSYM.2016.7728906"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"522","DOI":"10.1109\/TUFFC.2018.2793580","article-title":"A spatial coherence approach to minimum variance beamforming for plane-wave compounding","volume":"65","author":"Nguyen","year":"2018","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2097","DOI":"10.1109\/TUFFC.2009.1293","article-title":"MVDR-based coherence weighting for high-frame-rate adaptive imaging","volume":"56","author":"Wang","year":"2009","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1923","DOI":"10.1109\/TUFFC.2009.1268","article-title":"Minimum variance beamforming combined with adaptive coherence weighting applied to medical ultrasound imaging","volume":"56","author":"Asl","year":"2009","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1600","DOI":"10.1109\/TUFFC.2018.2851073","article-title":"Joint subarray coherence and minimum variance beamformer for multitransmission ultrasound imaging modalities","volume":"65","author":"Qi","year":"2018","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1329","DOI":"10.1109\/TUFFC.2010.1553","article-title":"Wiener beamforming and the coherence factor in ultrasound imaging","volume":"57","author":"Nilsen","year":"2010","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"106838","DOI":"10.1016\/j.ultras.2022.106838","article-title":"Plane wave ultrasound imaging using compressive sensing and minimum variance beamforming","volume":"127","author":"Paridar","year":"2023","journal-title":"Ultrasonics."},{"key":"ref_25","unstructured":"Hollman, K.W., Rigby, K.W., and Donnell, M.O. (1999, January 17\u201320). Coherence factor of speckle from a multi-row probe. Proceedings of the 1999 IEEE Ultrasonics Symposium, Tahoe, NV, USA."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1109\/TUFFC.2003.1182117","article-title":"Adaptive imaging using the generalized coherence factor","volume":"50","author":"Li","year":"2003","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1377","DOI":"10.1109\/TUFFC.2011.1957","article-title":"Short-lag spatial coherence of backscattered echoes: Imaging characteristics","volume":"58","author":"Lediju","year":"2011","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1976","DOI":"10.1109\/TUFFC.2014.006362","article-title":"Spatial coherence in human tissue: Implications for imaging and measurement","volume":"61","author":"Pinton","year":"2014","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1109\/TMI.2014.2371235","article-title":"The delay multiply and sum beamforming algorithm in ultrasound B-mode medical imaging","volume":"34","author":"Matrone","year":"2015","journal-title":"IEEE Trans. Med. Imag."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Matrone, G., and Ramalli, A. (2018). Spatial coherence of backscattered signals in multi-line transmit ultrasound imaging and its effect on short-lag filtered-delay multiply and sum beamforming. Appl. Sci., 8.","DOI":"10.3390\/app8040486"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1016\/j.ultras.2019.01.010","article-title":"Ultrasound baseband delay-multiply-and-sum (BB-DMAS) nonlinear beamforming","volume":"96","author":"Shen","year":"2019","journal-title":"Ultrasonics"},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Polichetti, M., Varray, F., B\u00e9ra, J.C., Cachard, C., and Nicolas, B. (2018). A nonlinear beamformer based on p-th root compression\u2014Application to plane wave ultrasound imaging. Appl. Sci., 8.","DOI":"10.3390\/app8040599"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1133","DOI":"10.1109\/TUFFC.2018.2831789","article-title":"Signal coherence and image amplitude with the filtered delay multiply and sum beamformer","volume":"65","author":"Prieur","year":"2018","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"106345","DOI":"10.1016\/j.ultras.2020.106345","article-title":"Computationally efficient minimum-variance baseband delay-multiply-and-sum beamforming for adjustable enhancement of ultrasound image resolution","volume":"112","author":"Shen","year":"2021","journal-title":"Ultrasonics"},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Huang, G.L., and Shen, C.C. (2022, January 10\u201313). Delay-multiply-and-sum beamforming with transmit minimum-variance estimation in multi-angle plane-wave imaging. Proceedings of the 2022 IEEE International Ultrasonics Symposium, Venice, Italy.","DOI":"10.1109\/IUS54386.2022.9958294"},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Shen, C.C., and Hsieh, P.Y. (2019). Two-dimensional spatial coherence for ultrasonic DMAS beamforming in multi-angle plane-wave imaging. Appl. Sci., 9.","DOI":"10.3390\/app9193973"},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Liebgott, H., Rodriguez-Molares, A., Cervenansky, F., Jensen, J.A., and Bernard, O. (2016, January 18\u201321). Plane-wave imaging challenge in medical ultrasound. Proceedings of the 2016 IEEE International Ultrasonics Symposium, Tours, France.","DOI":"10.1109\/ULTSYM.2016.7728908"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"745","DOI":"10.1109\/TUFFC.2019.2956855","article-title":"The generalized contrast-to-noise ratio: A formal definition for lesion detectability","volume":"67","author":"Rindal","year":"2020","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr."},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Synnev\u00e5g, J.F., Nilsen, C.I.C., and Holm, S. (2007, January 28\u201331). Speckle statistics in adaptive beamforming. Proceedings of the 2007 IEEE International Ultrasonics Symposium, New York, NY, USA.","DOI":"10.1109\/ULTSYM.2007.389"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"1641","DOI":"10.1109\/TUFFC.2020.3043795","article-title":"Minimum variance combined with modified delay multiply-and-sum beamforming for plane-wave compounding","volume":"68","author":"Ziksari","year":"2021","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Contr."},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"Hashemseresht, M., Afrakhteh, S., and Behnam, H. (2022). High-resolution and high-contrast ultrafast ultrasound imaging using coherent plane wave adaptive compounding. Biomed. Signal Process. Control, 73.","DOI":"10.1016\/j.bspc.2021.103446"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/1\/262\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T13:38:15Z","timestamp":1760103495000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/1\/262"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,2]]},"references-count":41,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,1]]}},"alternative-id":["s24010262"],"URL":"https:\/\/doi.org\/10.3390\/s24010262","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2024,1,2]]}}}