{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T22:42:48Z","timestamp":1793400168088,"version":"4.5.0"},"reference-count":24,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2024,1,19]],"date-time":"2024-01-19T00:00:00Z","timestamp":1705622400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Science and Technology Projects of State Grid Chongqing Electric Power Company Ultra High Voltage Branch","award":["SGCQJX00YJJS2310465"],"award-info":[{"award-number":["SGCQJX00YJJS2310465"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Residual current is an important monitoring quantity of a power system, and a current sensor plays an important role in detecting current. The substation environment is complex. In addition to the power frequency signal, residual current also has AC and DC components. But it is also affected by the stray magnetic field of the substation. Therefore, the accuracy of the current sensor demands higher requirements. The tunnel magnetoresistive sensor has the advantages of a stable operation, high efficiency, and energy saving, but it is easily affected by the external stray magnetic field during measurements, resulting in a large error. Therefore, this paper proposes a residual-current sensing monitoring system considering the magnetic shielding effect. The root mean square error of the magnetic shielding structure is only 0.572 mA, which can effectively reduce the influence of the external magnetic field and improve the detection accuracy. At the same time, the DC measurement error is less than 1%, the AC measurement error is less than 5%, and the hybrid AC\/DC error is less than 8%. It has good response ability and can accurately detect residual current.<\/jats:p>","DOI":"10.3390\/s24020632","type":"journal-article","created":{"date-parts":[[2024,1,19]],"date-time":"2024-01-19T03:33:41Z","timestamp":1705635221000},"page":"632","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Research on Residual-Current Measurement System of Substation Considering Magnetic Shielding Effect"],"prefix":"10.3390","volume":"24","author":[{"given":"Jinhu","family":"Tian","sequence":"first","affiliation":[{"name":"State Grid Chongqing Electric Power Company Ultra High Voltage Branch, Chongqing 400039, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yu","family":"Xu","sequence":"additional","affiliation":[{"name":"State Grid Chongqing Electric Power Company Ultra High Voltage Branch, Chongqing 400039, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Yang","sequence":"additional","affiliation":[{"name":"State Grid Chongqing Electric Power Company, Chongqing 400015, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yingchun","family":"Zhao","sequence":"additional","affiliation":[{"name":"State Grid Chongqing Electric Power Company Ultra High Voltage Branch, Chongqing 400039, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Man","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing 400044, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4771-9456","authenticated-orcid":false,"given":"Jingang","family":"Wang","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing 400044, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2024,1,19]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"78818","DOI":"10.1109\/ACCESS.2022.3191349","article-title":"A New Current Transducer for On-Line Monitoring of Leakage Current on HV Insulator Strings","volume":"10","author":"Villalobos","year":"2022","journal-title":"IEEE Access"},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Ketjoy, N., Mensin, P., and Chamsa-ard, W. (2022). Impacts on Insulation Resistance of Thin Film Modules: A Case Study of a Flooding of a Photovoltaic Power Plant in Thailand. PLoS ONE, 17.","DOI":"10.1371\/journal.pone.0274839"},{"key":"ref_3","first-page":"92514","article-title":"The Leakage Current Components as a Diagnostic Tool to Estimate Contamination Level on High Voltage Insulators","volume":"8","author":"Salem","year":"2020","journal-title":"IEEE Access"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1016\/j.egyr.2022.08.062","article-title":"Optimal Design and Implementation of Tunnelling Magnetoresistance Based Small Current Sensor with Temperature Compensation","volume":"8","author":"Lei","year":"2022","journal-title":"Energy Rep."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1109\/TEC.2018.2874101","article-title":"Mitigation of DC Current Injection in Transformer-Less Grid-Connected Inverters Using a Voltage Filtering DC Extraction Approach","volume":"34","author":"Zhang","year":"2019","journal-title":"IEEE Trans. Energy Convers."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1109\/TIE.2016.2542126","article-title":"High-Precision Active Suppression of DC Bias in AC Grids by Grid-Connected Power Converters","volume":"64","author":"Vukosavic","year":"2017","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1179","DOI":"10.1109\/TPWRD.2014.2386257","article-title":"High-Precision Sensing of DC Bias in AC Grids","volume":"30","author":"Vukosavic","year":"2015","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1756","DOI":"10.1109\/JSEN.2009.2030880","article-title":"Full Wheatstone Bridge Spin-Valve Based Sensors for IC Currents Monitoring","volume":"9","author":"Reig","year":"2009","journal-title":"IEEE Sens. J."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.sna.2005.09.046","article-title":"Tunnel Magnetoresistive Current Sensors for IC Testing","volume":"129","author":"Boeve","year":"2006","journal-title":"Sens. Actuators A Phys."},{"key":"ref_10","first-page":"1","article-title":"TMR Busbar Current Sensor with Good Frequency Characteristics","volume":"70","author":"Xu","year":"2021","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1016\/j.egyr.2021.08.043","article-title":"Research on Suppression of External Magnetic Field Interference of Tunnel Magnetoresistive Sensor Based on Versoria Variable Step Improved Adaptive Filtering Method","volume":"7","author":"Yu","year":"2021","journal-title":"Energy Rep."},{"key":"ref_12","first-page":"1","article-title":"Optimization Design of a Giant Magneto Resistive Effect Based Current Sensor with a Magnetic Shielding","volume":"24","author":"Yang","year":"2014","journal-title":"IEEE Trans. Appl. Supercond."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"6684","DOI":"10.1109\/JSEN.2019.2914939","article-title":"Current Measurement with 3-D Coreless TMR Sensor Array for Inclined Conductor","volume":"19","author":"Zhang","year":"2019","journal-title":"IEEE Sens. J."},{"key":"ref_14","unstructured":"and Fari, P. (2009, January 19\u201323). Electrical Equivalent Circuits of Outdoor Insulators Based on Leakage Current Waveforms and Computer Simulation. Proceedings of the 2009 IEEE 9th International Conference on the Properties and Applications of Dielectric Materials, Harbin, China."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1109\/TPWRD.2004.837668","article-title":"Frequency Characteristics of Leakage Current Waveforms of a String of Suspension Insulators","volume":"20","author":"Suda","year":"2005","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1109\/94.946726","article-title":"Frequency Characteristics of Leakage Current Waveforms of an Artificially Polluted Suspension Insulator","volume":"8","author":"Suda","year":"2001","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1080\/00150193.2022.2087259","article-title":"Research on AC and DC Leakage Detection Technology Based on Fluxgate Principle","volume":"596","author":"Xu","year":"2022","journal-title":"Ferroelectrics"},{"key":"ref_18","unstructured":"Liu, L., Zhang, X., Xu, L., Luo, S., Zhao, S., Zhu, C., Li, S., Hu, G., Liu, D., and Wu, J. (2023, November 14). Direct Current Electronic Current Transformer Based on Current Divider and TMR Sensorr for Use in Direct Current Engineering, Has Combining Unit Providing Laser with Certain Energy Output to Remote Module through Optical Fiber Insulator. Available online: https:\/\/webofscience.clarivate.cn\/wos\/alldb\/full-record\/DIIDW:2022F5438V."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Gobi, K., Kannapiran, B., and Devaraj, D. (2017, January 23\u201325). Design of Non-Contact Transduction Based Pressure Sensor Using Tunneling Magnetoresistive (TMR) Principle. Proceedings of the IEEE International Conference on Intelligent Techniques in Control, Optimization and Signal Processing (INCOS), Srivilliputtur, India. Available online: https:\/\/webofscience.clarivate.cn\/wos\/alldb\/full-record\/WOS:000428309500069.","DOI":"10.1109\/ITCOSP.2017.8303140"},{"key":"ref_20","first-page":"1","article-title":"High Tunnel Magnetoresistance in Mo\/CoFe\/MgO Magnetic Tunnel Junction: A First-Principles Study","volume":"53","author":"Zhou","year":"2017","journal-title":"IEEE Trans. Magn."},{"key":"ref_21","first-page":"1","article-title":"A Novel Bar-Shaped Magnetic Shielding for Magnetoresistive Sensors in Current Measurement on Printed Circuit Boards","volume":"50","author":"Sun","year":"2014","journal-title":"IEEE Trans. Magn."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1088\/0022-3735\/20\/2\/007","article-title":"Improvement of the Properties of an Eddy Current Magnetic Shield with Active Compensation","volume":"20","author":"Malmivuo","year":"1987","journal-title":"J. Phys. E Sci. Instrum."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1486","DOI":"10.1109\/TIM.2012.2228751","article-title":"Magnetic Shielding Effectiveness of Current Comparator","volume":"62","author":"Shao","year":"2013","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1058","DOI":"10.1109\/TEMC.2022.3157164","article-title":"Novel Spiral-Gap Shielding Shell for a Rogowski Current Sensor","volume":"64","author":"Cheng","year":"2022","journal-title":"IEEE Trans. Electromagn. Compat."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/2\/632\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T13:45:42Z","timestamp":1760103942000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/2\/632"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,19]]},"references-count":24,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2024,1]]}},"alternative-id":["s24020632"],"URL":"https:\/\/doi.org\/10.3390\/s24020632","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,19]]}}}