{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,15]],"date-time":"2025-11-15T04:05:46Z","timestamp":1763179546024,"version":"build-2065373602"},"reference-count":26,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2024,2,5]],"date-time":"2024-02-05T00:00:00Z","timestamp":1707091200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Swiss National Science Foundation","award":["180575"],"award-info":[{"award-number":["180575"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Heat flux measurement shows potential for the early detection of infectious growth. Our research is motivated by the possibility of using heat flux sensors for the early detection of infection on aortic vascular grafts by measuring the onset of bacterial growth. Applying heat flux measurement as an infectious marker on implant surfaces is yet to be experimentally explored. We have previously shown the measurement of the exponential growth curve of a bacterial population in a thermally stabilized laboratory environment. In this work, we further explore the limits of the microcalorimetric measurements via heat flux sensors in a microfluidic chip in a thermally fluctuating environment.<\/jats:p>","DOI":"10.3390\/s24031019","type":"journal-article","created":{"date-parts":[[2024,2,5]],"date-time":"2024-02-05T03:28:29Z","timestamp":1707103709000},"page":"1019","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Experimental In Vitro Microfluidic Calorimetric Chip Data towards the Early Detection of Infection on Implant Surfaces"],"prefix":"10.3390","volume":"24","author":[{"given":"Signe L. K.","family":"Vehusheia","sequence":"first","affiliation":[{"name":"Department of Mechanical and Process Engineering, ETH Zurich, 8092 Zurich, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cosmin I.","family":"Roman","sequence":"additional","affiliation":[{"name":"Department of Mechanical and Process Engineering, ETH Zurich, 8092 Zurich, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Markus","family":"Arnoldini","sequence":"additional","affiliation":[{"name":"Department of Health Sciences and Technology, ETH Zurich, 8093 Zurich, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christofer","family":"Hierold","sequence":"additional","affiliation":[{"name":"Department of Mechanical and Process Engineering, ETH Zurich, 8092 Zurich, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2024,2,5]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1038\/s41378-023-00525-z","article-title":"Enabling direct microcalorimetric measurement of metabolic activity and exothermic reactions onto microfluidic platforms via heat flux sensor integration","volume":"9","author":"Vehusheia","year":"2023","journal-title":"Microsystems Nanoeng."},{"key":"ref_2","first-page":"1","article-title":"Microcalorimetric method to assess phagocytosis: Macrophage-nanoparticle interactions","volume":"13","author":"Sarfraz","year":"2011","journal-title":"AAPS J."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/j.tca.2004.05.033","article-title":"Use of calorespirometric ratios, heat per CO2 and heat per O2, to quantify metabolic paths and energetics of growing cells","volume":"422","author":"Hansen","year":"2004","journal-title":"Thermochim. Acta"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1643","DOI":"10.1111\/j.1537-2995.2007.01336.x","article-title":"Microcalorimetry: A novel method for detection of microbial contamination in platelet products","volume":"47","author":"Trampuz","year":"2007","journal-title":"Transfusion"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Braissant, O., Wirz, D., G\u00f6pfert, B., and Daniels, A.U. (2010). Use of isothermal microcalorimetry to monitor microbial activities. BMC Microbiol., 13.","DOI":"10.1111\/j.1574-6968.2009.01819.x"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Butini, M.E., Abbandonato, G., Di Rienzo, C., Trampuz, A., and Di Luca, M. (2019). Isothermal microcalorimetry detects the presence of persister cells in a Staphylococcus aureus biofilm after vancomycin treatment. Front. Microbiol., 10.","DOI":"10.3389\/fmicb.2019.00332"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"115353","DOI":"10.1016\/j.trac.2021.116353","article-title":"Recent advances of microcalorimetry for studying cellular metabolic heat","volume":"143","author":"Wang","year":"2021","journal-title":"TrAC Trends Anal. Chem."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1016\/j.jbiotec.2005.10.008","article-title":"Chip calorimetry for the monitoring of whole cell biotransformation","volume":"122","author":"Maskow","year":"2006","journal-title":"J. Biotechnol."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Wang, S., Sha, X., Yu, S., and Zhao, Y. (2020). Nanocalorimeters for biomolecular analysis and cell metabolism monitoring. Biomicrofluidics, 14.","DOI":"10.1063\/1.5134870"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"2728","DOI":"10.1021\/ac702213d","article-title":"A microfabricated nanocalorimeter: Design, characterization, and chemical calibration","volume":"80","author":"Xu","year":"2008","journal-title":"Anal. Chem."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"2029","DOI":"10.1063\/1.1457532","article-title":"Heat conduction nanocalorimeter for pl-scale single cell measurements","volume":"80","author":"Johannessen","year":"2002","journal-title":"Appl. Phys. Lett."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1002\/advs.202003415","article-title":"A micromachined picocalorimeter sensor for liquid samples with application to chemical reactions and biochemistry","volume":"8","author":"Bae","year":"2021","journal-title":"Adv. Sci."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1900451","DOI":"10.1002\/smtd.201900451","article-title":"Microfluidics for Biomedical Analysis","volume":"4","author":"Yang","year":"2020","journal-title":"Small Methods"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1016\/j.molmed.2020.01.013","article-title":"Activity-Based Diagnostics: An Emerging Paradigm for Disease Detection and Monitoring","volume":"26","author":"Soleimany","year":"2020","journal-title":"Trends Mol. Med."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1007\/s10529-014-1734-8","article-title":"Microfluidic-based isolation of bacteria from whole blood for sepsis diagnostics","volume":"37","author":"Zelenin","year":"2015","journal-title":"Biotechnol. Lett."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.1039\/c3ib40049b","article-title":"Human kidney proximal tubule-on-a-chip for drug transport and nephrotoxicity assessment","volume":"5","author":"Jang","year":"2013","journal-title":"Integr. Biol."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1021\/acs.accounts.1c00729","article-title":"Droplet Microfluidics for High-Throughput Analysis of Antibiotic Susceptibility in Bacterial Cells and Populations","volume":"55","author":"Postek","year":"2021","journal-title":"Acc. Chem. Res."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"3687","DOI":"10.1039\/C8LC00596F","article-title":"Tumor-on-a-chip platform to investigate progression and drug sensitivity in cell lines and patient-derived organoids","volume":"18","author":"Shirure","year":"2018","journal-title":"Lab Chip"},{"key":"ref_19","unstructured":"Vehusheia, S.L.K., Roman, C., Cesarovic, N., and Hierold, C. (2023, January 25\u201329). Microfluidic thermal model for early detection of infection on aortic grafts. Proceedings of the Technical Digest of 22nd International Conference on Solid State Sensors, Actuators and Microsystems (Transducers), Kyoto, Japan."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"16198","DOI":"10.1038\/s41598-023-42259-y","article-title":"Finite element-based feasibility study on utilizing heat flux sensors for early detection of vascular graft infections","volume":"13","author":"Vehusheia","year":"2023","journal-title":"Sci. Rep."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1007\/s11908-011-0191-y","article-title":"Prosthetic Vascular Graft Infections: A Contemporary Approach to Diagnosis and Management","volume":"13","author":"Nagpal","year":"2011","journal-title":"Curr. Infect. Dis. Rep."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"2447","DOI":"10.1056\/NEJMoa0706930","article-title":"Hypothermia Therapy after Traumatic Brain Injury in Children","volume":"358","author":"Hutchison","year":"2008","journal-title":"N. Engl. J. Med."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.tca.2004.09.010","article-title":"Calorimetry of microbial growth using a thermopile based microreactor","volume":"427","author":"Mas","year":"2005","journal-title":"Thermochim. Acta"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1007\/s004020050361","article-title":"Susceptibility to local infection in biological internal fixation","volume":"119","author":"Arens","year":"1999","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Harrasser, N., Gorkotte, J., Obermeier, A., Feihl, S., Straub, M., Slotta-Huspenina, J., von Eisenhart-Rothe, R., Moser, W., Gruner, P., and de Wild, M. (2016). A new model of implant-related osteomyelitis in the metaphysis of rat tibiae. BMC Musculoskelet. Disord., 17.","DOI":"10.1186\/s12891-016-1005-z"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"820","DOI":"10.1016\/S0736-0266(00)00076-0","article-title":"A simple infection model using pre-colonized implants to reproduce rat chronic Staphylococcus aureus osteomyelitis and study antibiotic treatment","volume":"19","author":"Monzon","year":"2001","journal-title":"J. Orthop. Res."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/3\/1019\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T13:55:02Z","timestamp":1760104502000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/3\/1019"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,5]]},"references-count":26,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2024,2]]}},"alternative-id":["s24031019"],"URL":"https:\/\/doi.org\/10.3390\/s24031019","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2024,2,5]]}}}