{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T00:45:18Z","timestamp":1760143518849,"version":"build-2065373602"},"reference-count":18,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2024,2,11]],"date-time":"2024-02-11T00:00:00Z","timestamp":1707609600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"the National Key R&amp;D Program of China","award":["2021YFC2202401"],"award-info":[{"award-number":["2021YFC2202401"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The performance of the capacitive gap-sensing system plays a critical role in a satellite-based gravity gradiometer that is developed using an electrostatic accelerometer. The capacitive sensing gain mainly depends on the stabilized injection bias amplitude, the gain of the transformer bridge, and the trans-impedance amplifier. Previous studies have indicated that amplitude noise is the main factor influencing the noise of capacitive displacement detection. Analyzing the capacitive gap-sensing system indicates that the amplitude, frequency, phase, and broadband noises of the stabilized injection bias have varying levels of influence on the performance of the detection system. This paper establishes a model to clarify the mentioned effects. The validation of the sub-tests demonstrates that the analysis and evaluation results of various noise coefficients are highly consistent with the model\u2019s predicted outcomes.<\/jats:p>","DOI":"10.3390\/s24041188","type":"journal-article","created":{"date-parts":[[2024,2,12]],"date-time":"2024-02-12T03:50:27Z","timestamp":1707709827000},"page":"1188","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Influence of the Injection Bias on the Capacitive Sensing of the Test Mass Motion of Satellite Gravity Gradiometers"],"prefix":"10.3390","volume":"24","author":[{"given":"Hengtong","family":"Xu","sequence":"first","affiliation":[{"name":"Science and Technology on Vacuum Technology and Physics Laboratory, Lanzhou Institute of Physics, Lanzhou 730000, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jungang","family":"Lei","sequence":"additional","affiliation":[{"name":"Science and Technology on Vacuum Technology and Physics Laboratory, Lanzhou Institute of Physics, Lanzhou 730000, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Detian","family":"Li","sequence":"additional","affiliation":[{"name":"Science and Technology on Vacuum Technology and Physics Laboratory, Lanzhou Institute of Physics, Lanzhou 730000, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yunpeng","family":"Li","sequence":"additional","affiliation":[{"name":"Science and Technology on Vacuum Technology and Physics Laboratory, Lanzhou Institute of Physics, Lanzhou 730000, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wenze","family":"Tao","sequence":"additional","affiliation":[{"name":"Science and Technology on Vacuum Technology and Physics Laboratory, Lanzhou Institute of Physics, Lanzhou 730000, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wenyan","family":"Zhang","sequence":"additional","affiliation":[{"name":"Science and Technology on Vacuum Technology and Physics Laboratory, Lanzhou Institute of Physics, Lanzhou 730000, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Meng","family":"Chen","sequence":"additional","affiliation":[{"name":"Science and Technology on Vacuum Technology and Physics Laboratory, Lanzhou Institute of Physics, Lanzhou 730000, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2024,2,11]]},"reference":[{"key":"ref_1","unstructured":"Drinkwater, M., and Kern, M. (2006). Calibration and Validation Plan for L1b Data Products, ESA ESTEC. Technical Report EOP-SM\/1363\/MD-md."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Beutler, G.B., Drinkwater, M., Rummel, R., and von Steiger, R. (2003). GOCE: ESA\u2019s First Earth Explorer Core Mission, Earth Gravity Field from Space-from Sensors to Earth Sciences, Kluwer Academic Publishers. Space Sciences Series of ISSI.","DOI":"10.1007\/978-94-017-1333-7"},{"key":"ref_3","unstructured":"S\u00fcnkel, H. (1986). Lecture Notes in Earth Sciences, Springer."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"777","DOI":"10.1007\/s00190-011-0500-0","article-title":"GOCE gravitational gradiometry","volume":"85","author":"Rummel","year":"2011","journal-title":"J. Geod."},{"key":"ref_5","unstructured":"Marque, J., Christophe, B., Liorzou, F., Bodovill\u00e9, G., Foulon, B., Gu\u00e9rard, J., and Lebat, V. (October, January 29). The ultra sensitive accelerometers of the ESA GOCE mission. Proceedings of the 59th International Astronautical Congress (IAC-08-B1. 3.7), Glasgow, Scotland."},{"key":"ref_6","unstructured":"Berg\u00e9, J., Christophe, B., and Foulon, B. (2013, January 9\u201313). GOCE accelerometers data revisited: Stability and detector noise. Proceedings of the ESA Living Planet Symposium, Edinburgh, UK."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1023\/B:GEOP.0000004264.04667.5e","article-title":"The European gravity field and steady-state ocean circulation explorer satellite mission its impact on geophysics","volume":"24","author":"Johannessen","year":"2003","journal-title":"Surv. Geophys."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1016\/S0924-4247(99)00227-7","article-title":"Capacitive detection scheme for space accelerometers applications","volume":"78","author":"Josselin","year":"1999","journal-title":"Sens. Actuators A Phys."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1016\/S0094-5765(99)00132-0","article-title":"Electrostatic space accelerometers for present and future missions","volume":"45","author":"Touboul","year":"1999","journal-title":"Acta Astronaut."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1751","DOI":"10.1088\/0264-9381\/19\/7\/371","article-title":"Position sensors for LISA drag-free control","volume":"19","author":"Weber","year":"2002","journal-title":"Class. Quantum Gravity"},{"key":"ref_11","unstructured":"Weber, W.J., Bortoluzzi, D., Cavalleri, A., Carbone, L., Da Lio, M., Dolesi, R., Fontana, G., Hoyle, C.D., Hueller, M., and Vitale, S. (2003). Gravitational-Wave Detection, SPIE."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"062004","DOI":"10.1103\/PhysRevD.96.062004","article-title":"Capacitive sensing of test mass motion with nanometer precision over millimeter-wide sensing gaps for space-borne gravitational reference sensors","volume":"96","author":"Armano","year":"2017","journal-title":"Phys. Rev. D"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"S99","DOI":"10.1088\/0264-9381\/20\/10\/312","article-title":"Gravitational sensor for LISA and its technology demonstration mission","volume":"20","author":"Dolesi","year":"2003","journal-title":"Class. Quantum Gravity"},{"key":"ref_14","unstructured":"Christophe, B., Marque, J., and Foulon, B. (2010, January 21\u201324). In-orbit data verification of the accelerometers of the ESA GOCE mission. Proceedings of the Annual Meeting of the French Society of Astronomy and Astrophysics, SF2A-2010, Marseille, France."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"574","DOI":"10.1016\/j.sna.2011.03.011","article-title":"Actuation to sensing crosstalk investigation in the inertial sensor front-end electronics of the laser interferometer space antenna pathfinder satellite","volume":"167","author":"Gan","year":"2011","journal-title":"Sens. Actuators A Phys."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"112020","DOI":"10.1016\/j.sna.2020.112020","article-title":"Amplitude stability analysis and experimental investigation of an ac excitation signal for capacitive sensors","volume":"309","author":"Li","year":"2020","journal-title":"Sens. Actuators A Phys."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"112734","DOI":"10.1016\/j.measurement.2023.112734","article-title":"A novel modem model insensitive to the effect of the modulated carrier and the demodulated-signal phase adapted for capacitive sensors","volume":"213","author":"Li","year":"2023","journal-title":"Measurement"},{"key":"ref_18","first-page":"012040","article-title":"GRS electronics for a space-borne gravitational wave observatory","volume":"Volume 840","author":"Mance","year":"2017","journal-title":"Journal of Physics: Conference Series"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/4\/1188\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T13:58:39Z","timestamp":1760104719000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/4\/1188"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,11]]},"references-count":18,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2024,2]]}},"alternative-id":["s24041188"],"URL":"https:\/\/doi.org\/10.3390\/s24041188","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2024,2,11]]}}}