{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T20:44:02Z","timestamp":1793738642851,"version":"4.6.1"},"reference-count":50,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2024,2,27]],"date-time":"2024-02-27T00:00:00Z","timestamp":1708992000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003246","name":"Dutch Research Council (NWO)","doi-asserted-by":"publisher","award":["628.011.021"],"award-info":[{"award-number":["628.011.021"]}],"id":[{"id":"10.13039\/501100003246","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Background: Data loss in wearable sensors is an inevitable problem that leads to misrepresentation during diabetes health monitoring. We systematically investigated missing wearable sensors data to get causal insight into the mechanisms leading to missing data. Methods: Two-week-long data from a continuous glucose monitor and a Fitbit activity tracker recording heart rate (HR) and step count in free-living patients with type 2 diabetes mellitus were used. The gap size distribution was fitted with a Planck distribution to test for missing not at random (MNAR) and a difference between distributions was tested with a Chi-squared test. Significant missing data dispersion over time was tested with the Kruskal\u2013Wallis test and Dunn post hoc analysis. Results: Data from 77 subjects resulted in 73 cleaned glucose, 70 HR and 68 step count recordings. The glucose gap sizes followed a Planck distribution. HR and step count gap frequency differed significantly (p &lt; 0.001), and the missing data were therefore MNAR. In glucose, more missing data were found in the night (23:00\u201301:00), and in step count, more at measurement days 6 and 7 (p &lt; 0.001). In both cases, missing data were caused by insufficient frequency of data synchronization. Conclusions: Our novel approach of investigating missing data statistics revealed the mechanisms for missing data in Fitbit and CGM data.<\/jats:p>","DOI":"10.3390\/s24051526","type":"journal-article","created":{"date-parts":[[2024,2,27]],"date-time":"2024-02-27T05:20:32Z","timestamp":1709011232000},"page":"1526","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":21,"title":["Missing Data Statistics Provide Causal Insights into Data Loss in Diabetes Health Monitoring by Wearable Sensors"],"prefix":"10.3390","volume":"24","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2900-9861","authenticated-orcid":false,"given":"Carlijn I. R.","family":"Braem","sequence":"first","affiliation":[{"name":"Department of Biomedical Signals and Systems, University of Twente, 7522 NB Enschede, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6968-8064","authenticated-orcid":false,"given":"Utku S.","family":"Yavuz","sequence":"additional","affiliation":[{"name":"Department of Biomedical Signals and Systems, University of Twente, 7522 NB Enschede, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3065-3876","authenticated-orcid":false,"given":"Hermie J.","family":"Hermens","sequence":"additional","affiliation":[{"name":"Department of Biomedical Signals and Systems, University of Twente, 7522 NB Enschede, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1796-9999","authenticated-orcid":false,"given":"Peter H.","family":"Veltink","sequence":"additional","affiliation":[{"name":"Department of Biomedical Signals and Systems, University of Twente, 7522 NB Enschede, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2024,2,27]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"690","DOI":"10.1037\/a0016136","article-title":"Effective Techniques in Healthy Eating and Physical Activity Interventions: A Meta-Regression","volume":"28","author":"Michie","year":"2009","journal-title":"Health Psychol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1016\/j.amepre.2017.08.015","article-title":"Wearable Technology and Physical Activity in Chronic Disease: Opportunities and Challenges","volume":"54","author":"Phillips","year":"2018","journal-title":"Am. J. Prev. Med."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"631","DOI":"10.1111\/dom.14238","article-title":"Glycaemic Profiles of Diverse Patients with Type 2 Diabetes Using Basal Insulin: MOBILE Study Baseline Data","volume":"23","author":"Peters","year":"2021","journal-title":"Diabetes Obes. Metab."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Maher, C., Ryan, J., Ambrosi, C., and Edney, S. (2017). Users\u2019 Experiences of Wearable Activity Trackers: A Cross-Sectional Study. BMC Public Health, 17.","DOI":"10.1186\/s12889-017-4888-1"},{"key":"ref_5","first-page":"S68","article-title":"Best Practices for Using Physical Activity Monitors in Population-Based Research","volume":"44","author":"Matthews","year":"2012","journal-title":"MSSE"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"9633","DOI":"10.1038\/s41598-021-89141-3","article-title":"Number of Daily Measurements Needed to Estimate Habitual Step Count Levels Using Wrist-Worn Trackers and Smartphones in 212,048 Adults","volume":"11","author":"Yao","year":"2021","journal-title":"Sci. Rep."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1593","DOI":"10.2337\/dci19-0028","article-title":"Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations from the International Consensus on Time in Range","volume":"42","author":"Battelino","year":"2019","journal-title":"Diabetes Care"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1089\/dia.2017.0455","article-title":"Optimal Sampling Duration for Continuous Glucose Monitoring to Determine Long-Term Glycemic Control","volume":"20","author":"Riddlesworth","year":"2018","journal-title":"Diabetes Technol. Ther."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1186\/s12966-019-0824-3","article-title":"Effectiveness of Interventions Using Self-Monitoring to Reduce Sedentary Behavior in Adults: A Systematic Review and Meta-Analysis","volume":"16","author":"Compernolle","year":"2019","journal-title":"Int. J. Behav. Nutr. Phys. Act."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"e020162","DOI":"10.1136\/bmjopen-2017-020162","article-title":"Reliability of Wireless Monitoring Using a Wearable Patch Sensor in High-Risk Surgical Patients at a Step-down Unit in the Netherlands: A Clinical Validation Study","volume":"8","author":"Breteler","year":"2018","journal-title":"BMJ Open"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1740","DOI":"10.1007\/s00415-018-8786-y","article-title":"Wearable Sensors for Clinical Applications in Epilepsy, Parkinson\u2019s Disease, and Stroke: A Mixed-Methods Systematic Review","volume":"265","author":"Johansson","year":"2018","journal-title":"J. Neurol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"9026","DOI":"10.3390\/s101009026","article-title":"Wearable Systems for Monitoring Mobility-Related Activities in Chronic Disease: A Systematic Review","volume":"10","author":"Allet","year":"2010","journal-title":"Sensors"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Haescher, M., Matthies, D.J.C., Krause, S., and Bieber, G. (2019, January 5\u20137). Presenting a Data Imputation Concept to Support the Continuous Assessment of Human Vital Data and Activities. Proceedings of the 12th ACM International Conference on PErvasive Technologies Related to Assistive Environments, Rhodes, Greece.","DOI":"10.1145\/3316782.3322785"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Yang, S., Kalpakis, K., Mackenzie, C.F., Stansbury, L.G., Stein, D.M., Scalea, T.M., and Hu, P.F. (2012, January 12\u201315). Online Recovery of Missing Values in Vital Signs Data Streams Using Low-Rank Matrix Completion. Proceedings of the 2012 11th International Conference on Machine Learning and Applications, Boca Raton, FL, USA.","DOI":"10.1109\/ICMLA.2012.55"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Chakrabarti, S., Biswas, N., Karnani, K., Padul, V., Jones, L.D., Kesari, S., and Ashili, S. (2023). Binned Data Provide Better Imputation of Missing Time Series Data from Wearables. Sensors, 23.","DOI":"10.3390\/s23031454"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Lin, S., Wu, X., Martinez, G., and Chawla, N.V. (2020, January 7\u20139). Filling Missing Values on Wearable-Sensory Time Series Data. Proceedings of the 2020 SIAM International Conference on Data Mining (SDM), Cincinnati, OH, USA.","DOI":"10.1137\/1.9781611976236.6"},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Wu, X., Mattingly, S., Mirjafari, S., Huang, C., and Chawla, N.V. (2020, January 19\u201323). Personalized Imputation on Wearable-Sensory Time Series via Knowledge Transfer. Proceedings of the 29th ACM International Conference on Information & Knowledge Management, Virtual.","DOI":"10.1145\/3340531.3411879"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"e30863","DOI":"10.2196\/30863","article-title":"Continuous Monitoring of Vital Signs with Wearable Sensors During Daily Life Activities: Validation Study","volume":"6","author":"Haveman","year":"2022","journal-title":"JMIR Form. Res."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Syversen, A., Dosis, A., Jayne, D., and Zhang, Z. (2024). Wearable Sensors as a Preoperative Assessment Tool: A Review. Sensors, 24.","DOI":"10.3390\/s24020482"},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Staffini, A., Svensson, T., Chung, U., and Svensson, A.K. (2023). A Disentangled VAE-BiLSTM Model for Heart Rate Anomaly Detection. Bioengineering, 10.","DOI":"10.3390\/bioengineering10060683"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Staffini, A., Svensson, T., Chung, U., and Svensson, A.K. (2022). Heart Rate Modeling and Prediction Using Autoregressive Models and Deep Learning. Sensors, 22.","DOI":"10.3390\/s22010034"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1007\/s41666-019-00063-2","article-title":"Predicting Glycaemia in Type 1 Diabetes Patients: Experiments in Feature Engineering and Data Imputation","volume":"4","author":"Jeon","year":"2020","journal-title":"J. Health Inf. Res."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Gashi, S., Alecci, L., Gjoreski, M., Di Lascio, E., Mehrotra, A., Musolesi, M., Debus, M.E., Gasparini, F., and Santini, S. (2022, January 18\u201321). Handling Missing Data for Sleep Monitoring Systems. Proceedings of the 2022 10th International Conference on Affective Computing and Intelligent Interaction (ACII), Nara, Japan.","DOI":"10.1109\/ACII55700.2022.9953832"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"965","DOI":"10.3945\/ajcn.112.052738","article-title":"Data Imputation for Accelerometer-Measured Physical Activity: The Combined Approach","volume":"97","author":"Lee","year":"2013","journal-title":"Am. J. Clin. Nutr."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Chinapaw, M.J.M., de Niet, M., Verloigne, M., De Bourdeaudhuij, I., Brug, J., and Altenburg, T.M. (2014). From Sedentary Time to Sedentary Patterns: Accelerometer Data Reduction Decisions in Youth. PLoS ONE, 9.","DOI":"10.1371\/journal.pone.0111205"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.ypmed.2014.12.015","article-title":"Occurrence and Duration of Various Operational Definitions of Sedentary Bouts and Cross-Sectional Associations with Cardiometabolic Health Indicators: The ENERGY-Project","volume":"71","author":"Altenburg","year":"2015","journal-title":"Prev. Med."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Orstad, S.L., Gerchow, L., Patel, N.R., Reddy, M., Hernandez, C., Wilson, D.K., and Jay, M. (2021). Defining Valid Activity Monitor Data: A Multimethod Analysis of Weight-Loss Intervention Participants\u2019 Barriers to Wear and First 100 Days of Physical Activity. Informatics, 8.","DOI":"10.3390\/informatics8020039"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1089\/dia.2022.0093","article-title":"Impact of Different Types of Data Loss on Optimal Continuous Glucose Monitoring Sampling Duration","volume":"24","author":"Akturk","year":"2022","journal-title":"Diabetes Technol. Ther."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Chen, R., Jankovic, F., Marinsek, N., Foschini, L., Kourtis, L., Signorini, A., Pugh, M., Shen, J., Yaari, R., and Maljkovic, V. (2019, January 4\u20138). Developing Measures of Cognitive Impairment in the Real World from Consumer-Grade Multimodal Sensor Streams. Proceedings of the 25th ACM SIGKDD International Conference on Knowledge Discovery & Data Mining, Anchorage, AK, USA.","DOI":"10.1145\/3292500.3330690"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1093\/biomet\/63.3.581","article-title":"Inference and Missing Data","volume":"63","author":"Rubin","year":"1976","journal-title":"Biometrika"},{"key":"ref_31","unstructured":"Moritz, S. (2015). Comparison of Different Methods for Univariate Time Series Imputation in R. arXiv."},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Zhou, N., Patel, D., Iyengar, A., Shrivastava, S., and Bhamidipaty, A. (2020, January 10\u201313). A Verifiable Imputation Analysis for Univariate Time Series and Enabling Package. Proceedings of the 2020 IEEE International Conference on Big Data (Big Data), Atlanta, GA, USA.","DOI":"10.1109\/BigData50022.2020.9377909"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1587\/transinf.2018EDP7257","article-title":"Missing-Value Imputation of Continuous Missing Based on Deep Imputation Network Using Correlations among Multiple IoT Data Streams in a Smart Space","volume":"E102.D","author":"Lee","year":"2019","journal-title":"IEICE Trans. Inf. Syst."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"6085","DOI":"10.1038\/s41598-018-24271-9","article-title":"Recurrent Neural Networks for Multivariate Time Series with Missing Values","volume":"8","author":"Che","year":"2018","journal-title":"Sci. Rep."},{"key":"ref_35","doi-asserted-by":"crossref","unstructured":"Gant, C., Binnenmars, S., Berg, E., Bakker, S., Navis, G., and Laverman, G. (2017). Integrated Assessment of Pharmacological and Nutritional Cardiovascular Risk Management: Blood Pressure Control in the DIAbetes and LifEstyle Cohort Twente (DIALECT). Nutrients, 9.","DOI":"10.3390\/nu9070709"},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Den Braber, N., Vollenbroek-Hutten, M., Oosterwijk, M., Gant, C., Hagedoorn, I., Van Beijnum, B.-J., Hermens, H., and Laverman, G. (2019). Requirements of an Application to Monitor Diet, Physical Activity and Glucose Values in Patients with Type 2 Diabetes: The Diameter. Nutrients, 11.","DOI":"10.3390\/nu11020409"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1123\/japa.2020-0059","article-title":"Comparing Methods to Identify Wear-Time Intervals for Physical Activity with the Fitbit Charge 2","volume":"29","author":"Claudel","year":"2020","journal-title":"J. Aging Phys. Act."},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Wing, D., Godino, J.G., Baker, F.C., Yang, R., Chevance, G., Thompson, W.K., Reuter, C., Bartsch, H., Wilbur, A., and Straub, L.K. (2022). Recommendations for Identifying Valid Wear for Consumer-Level Wrist-Worn Activity Trackers and Acceptability of Extended Device Deployment in Children. Sensors, 22.","DOI":"10.3390\/s22239189"},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Hilden, P., Schwartz, J.E., Pascual, C., Diaz, K.M., and Goldsmith, J. (2023). How Many Days Are Needed? Measurement Reliability of Wearable Device Data to Assess Physical Activity. PLoS ONE, 18.","DOI":"10.1371\/journal.pone.0282162"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"e172","DOI":"10.1111\/hae.14624","article-title":"Comparison of Free-living Physical Activity Measurements between ActiGraph GT3X-BT and Fitbit Charge 3 in Young People with Haemophilia","volume":"28","author":"Matlary","year":"2022","journal-title":"Haemophilia"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"e040702","DOI":"10.1136\/bmjopen-2020-040702","article-title":"Multilevel Mobile Health Approach to Improve Cardiovascular Health in Resource-Limited Communities with Step It Up: A Randomised Controlled Trial Protocol Targeting Physical Activity","volume":"10","author":"Tamura","year":"2020","journal-title":"BMJ Open"},{"key":"ref_42","doi-asserted-by":"crossref","unstructured":"Hardcastle, S.J., Jim\u00e9nez-Castuera, R., Maxwell-Smith, C., Bulsara, M.K., and Hince, D. (2020). Fitbit Wear-Time and Patterns of Activity in Cancer Survivors throughout a Physical Activity Intervention and Follow-up: Exploratory Analysis from a Randomised Controlled Trial. PLoS ONE, 15.","DOI":"10.1371\/journal.pone.0240967"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"1763","DOI":"10.1213\/ANE.0000000000002864","article-title":"Correlation Coefficients: Appropriate Use and Interpretation","volume":"126","author":"Schober","year":"2018","journal-title":"Anesth. Analg."},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Gallager, R.G. (2013). Stochastic Processes: Theory for Applications, Cambridge University Press.","DOI":"10.1017\/CBO9781139626514"},{"key":"ref_45","unstructured":"(2023, June 30). Statistical Functions (Scipy.Stats)\u2014SciPy v1.11.1 Manual. Available online: https:\/\/docs.scipy.org\/doc\/scipy\/reference\/stats.html#discrete-distributions."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"143","DOI":"10.11613\/BM.2013.018","article-title":"The Chi-Square Test of Independence","volume":"23","author":"McHugh","year":"2013","journal-title":"Biochem. Med."},{"key":"ref_47","unstructured":"Weir, C.B., and Jan, A. (2024). StatPearls, StatPearls Publishing."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"S97","DOI":"10.2337\/dc23-S006","article-title":"6. Glycemic Targets: Standards of Care in Diabetes\u20142023","volume":"46","author":"ElSayed","year":"2023","journal-title":"Diabetes Care"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"e22218","DOI":"10.2196\/22218","article-title":"Predicting Participant Compliance with Fitness Tracker Wearing and Ecological Momentary Assessment Protocols in Information Workers: Observational Study","volume":"9","author":"Martinez","year":"2021","journal-title":"JMIR mHealth uHealth"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"758","DOI":"10.4103\/ijem.IJEM_156_17","article-title":"Sleep Disorders in Type 2 Diabetes","volume":"21","author":"Khandelwal","year":"2017","journal-title":"Indian. J. Endocrinol. Metab."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/5\/1526\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T14:05:31Z","timestamp":1760105131000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/5\/1526"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,27]]},"references-count":50,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2024,3]]}},"alternative-id":["s24051526"],"URL":"https:\/\/doi.org\/10.3390\/s24051526","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,27]]}}}