{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T00:56:01Z","timestamp":1760144161425,"version":"build-2065373602"},"reference-count":38,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2024,3,27]],"date-time":"2024-03-27T00:00:00Z","timestamp":1711497600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["U22A20229","tsqn202306231"],"award-info":[{"award-number":["U22A20229","tsqn202306231"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Mount Taishan Scholar Programme of Shandong Province","award":["U22A20229","tsqn202306231"],"award-info":[{"award-number":["U22A20229","tsqn202306231"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A composite solid chloride sensor consisting of two single sensors, i.e., Ag\/AgCl working electrode and Mn\/MnO2 reference electrode, was developed. The Ag\/AgCl electrode was prepared by the anodic polarization method, while the Mn\/MnO2 reference electrode was prepared using the powder compaction technique. Then, the electrochemical performances such as stability, reproducibility, and sensitivity of the composite and single sensors were investigated in a saturated Ca(OH)2 solution and mortar specimen. A current density of 0.5 mA\/cm2 and polarization time of 2.5 h were the optimal preparation parameters of the Ag\/AgCl selective electrode. The Ag\/AgCl selective electrode showed a linear potential response with the logarithm of chloride ion content in solution and had good stability, reproducibility, and anti-polarization performances. In addition, the Mn\/MnO2 electrode exhibited potential stability after being activated in an alkaline solution for 60 days. The composite sensor demonstrated exceptional sensitivity to the Cl\u2212 content, boasting a slope of approximately 51.1 mV\/decade, and showcased excellent stability in both solution and mortar specimens. In every measurement, the time needed for the potential of a composite sensor to become stable was less than 30 s. The sensor enables non-destructive in situ monitoring of the chloride ion content in cement mortar, thus realizing early warning of deterioration of reinforcement and guaranteeing long service life of the structure.<\/jats:p>","DOI":"10.3390\/s24072149","type":"journal-article","created":{"date-parts":[[2024,3,27]],"date-time":"2024-03-27T13:39:56Z","timestamp":1711546796000},"page":"2149","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Embeddable Chloride Sensor for Monitoring Chloride Penetration into Cement Mortar"],"prefix":"10.3390","volume":"24","author":[{"given":"Min","family":"Zhang","sequence":"first","affiliation":[{"name":"School of Civil Engineering, Qingdao University of Technology, Qingdao 266033, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hua","family":"Fu","sequence":"additional","affiliation":[{"name":"School of Civil Engineering, Qingdao University of Technology, Qingdao 266033, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Li","family":"Tian","sequence":"additional","affiliation":[{"name":"School of Civil Engineering, Qingdao University of Technology, Qingdao 266033, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhenxing","family":"Du","sequence":"additional","affiliation":[{"name":"School of Civil Engineering, Qingdao University of Technology, Qingdao 266033, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6066-7734","authenticated-orcid":false,"given":"Penggang","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Civil Engineering, Qingdao University of Technology, Qingdao 266033, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2024,3,27]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"31252","DOI":"10.1039\/C7RA05532C","article-title":"Fabrication and evaluation of a highly durable and reliable chloride monitoring sensor for civil infrastructure","volume":"7","author":"Karthick","year":"2017","journal-title":"RSC Adv."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Bertolini, L., Elsener, B., Pedeferri, P., and Polder, R. (2013). Corrosion of Steel in Concrete\u2014Prevention, Diagnosis, Repair, Wiley VCH Verlag Gmbh & Co Kgaa.","DOI":"10.1002\/9783527651696"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"126815","DOI":"10.1016\/j.conbuildmat.2022.126815","article-title":"Effect of nCSH-PCE and slag powder on the autogenous shrinkage of high-strength steam-free pipe pile concrete","volume":"325","author":"Wang","year":"2022","journal-title":"Constr. Build. Mater."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1207","DOI":"10.1016\/S0008-8846(01)00544-0","article-title":"Sources of error in using silver\/silver chloride electrodes to monitor chloride activity in concrete","volume":"31","author":"Atkins","year":"2001","journal-title":"Cem. Concr. Res."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1016\/j.snb.2013.07.046","article-title":"A chronopotentiometric approach for measuring chloride ion concentration","volume":"B188","author":"Abbas","year":"2013","journal-title":"Sens. Actuators B Chem."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.conbuildmat.2014.06.009","article-title":"Non-destructive methods for measuring chloride ingress into concrete: State-of-the-art and future challenges","volume":"68","author":"Schoefs","year":"2014","journal-title":"Constr. Build. Mater."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1016\/0008-8846(87)90079-2","article-title":"Assessment of simple methods of determining the free chloride ion content of cement paste","volume":"17","author":"Arya","year":"1987","journal-title":"Cem. Concr. Res."},{"key":"ref_8","first-page":"1866","article-title":"Research on a fiber Bragg grating based corrosion sensor","volume":"26","author":"Song","year":"2015","journal-title":"J. Optoelectron. Laser"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1002\/stc.1586","article-title":"Corrosion monitoring of post-tensioned concrete structures using fractal analysis of guided ultrasonic waves","volume":"21","author":"Moustafa","year":"2014","journal-title":"Struct. Control Health Monit."},{"key":"ref_10","first-page":"546","article-title":"Applications of Fiber Optic Sensor Technique to Corrosion Monitoring","volume":"20","author":"Dong","year":"2004","journal-title":"J. Anal. Sci."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1016\/j.conbuildmat.2016.05.163","article-title":"Characterization of Ag\/AgCl electrode manufactured by immersion in sodium hypochloride acid for monitoring chloride content in concrete","volume":"122","author":"Jin","year":"2016","journal-title":"Constr. Build. Mater."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"3179","DOI":"10.1021\/ac0517139","article-title":"In situ measurement of Cl-concentrations and pH at the reinforcing steel\/concrete interface by combination sensors","volume":"78","author":"Du","year":"2006","journal-title":"Anal. Chem."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1016\/0008-8846(95)00218-9","article-title":"Monitoring chloride concentrations in hardened cement pastes using ion selective electrodes","volume":"26","author":"Atkins","year":"1996","journal-title":"Cem. Concr. Res."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"631","DOI":"10.1002\/maco.200905296","article-title":"Analysis of the variability of chloride threshold values in the literature","volume":"60","author":"Alonso","year":"2009","journal-title":"Mater. Corros."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"7527","DOI":"10.1007\/s10853-018-2083-0","article-title":"Microstructure, surface chemistry and electrochemical response of Ag|AgCl sensors in alkaline media","volume":"53","author":"Pargar","year":"2018","journal-title":"J. Mater. Sci."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.1016\/0008-8846(96)00104-4","article-title":"Embeddable Ag\/AgCl sensors for in-situ monitoring chloride contents in concrete","volume":"26","year":"1996","journal-title":"Cem. Concr. Res."},{"key":"ref_17","first-page":"9","article-title":"Powder Pellets Preparation for X-Ray Fluorescence Analysis","volume":"15","author":"Shanghua","year":"1998","journal-title":"Chin. J. Spectrosc. Lab."},{"key":"ref_18","first-page":"371","article-title":"Application of the Ag\/AgCl chloride sensor in concrete","volume":"41","author":"Weixuan","year":"2010","journal-title":"J. Funct. Mater."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"8135492","DOI":"10.1155\/2018\/8135492","article-title":"Potentiometric Response of Ag\/AgCl Chloride Sensors in Model Alkaline Medium","volume":"2018","author":"Pargar","year":"2018","journal-title":"Adv. Mater. Sci. Eng."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2637","DOI":"10.1617\/s11527-015-0673-8","article-title":"Ag\/AgCl ion-selective electrodes in neutral and alkaline environments containing interfering ions","volume":"49","author":"Femenias","year":"2016","journal-title":"Mater. Struct."},{"key":"ref_21","unstructured":"Pargar, F., Koleva, D., Koenders, E., and Van Breugel, K. (2014, January 26\u201328). The importance of chloride sensors stability in monitoring ageing phenomena in concrete structures: Ag\/AgCl electrodes performance in simulated pore-water environment. Proceedings of the AMS 14: 1st Ageing of Materials & Structures Conference, Delft, The Netherlands."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1016\/j.cemconcomp.2006.01.005","article-title":"Multiprobe chloride sensor for in situ monitoring of reinforced concrete structures","volume":"28","author":"Montemor","year":"2006","journal-title":"Cem. Concr. Compos."},{"key":"ref_23","first-page":"99","article-title":"Preparation and properties of a pre-embeddable monitoring sensor in concrete","volume":"3","author":"Tang","year":"2015","journal-title":"Port Waterw. Eng."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1016\/j.snb.2005.10.018","article-title":"All-solid-state miniaturised planar reference electrodes based on ionic liquids","volume":"B115","author":"Maminska","year":"2006","journal-title":"Sens. Actuators B"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1016\/j.matlet.2005.09.058","article-title":"Electrochemical studies on the solid embeddable reference sensors for corrosion monitoring in concrete structure","volume":"60","author":"Muralidharan","year":"2006","journal-title":"Mater. Lett."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1016\/j.snb.2013.10.123","article-title":"Long-term relative performance of embedded sensor and surface mounted electrode for corrosion monitoring of steel in concrete structures","volume":"B192","author":"Karthick","year":"2014","journal-title":"Sens. Actuators B Chem."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1451","DOI":"10.1016\/j.corsci.2011.01.025","article-title":"Chloride induced reinforcement corrosion: Electrochemical monitoring of initiation stage and chloride threshold values","volume":"53","author":"Angst","year":"2011","journal-title":"Corros. Sci."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1016\/S0022-0728(03)00045-7","article-title":"Electrochemical behavior of manganese dioxide on a gold electrode","volume":"543","author":"Rogulski","year":"2003","journal-title":"J. Electroanal. Chem."},{"key":"ref_29","first-page":"207","article-title":"Preparation and Characterization of Mn\/MnO2 Reference Electrode for Buried Concrete","volume":"52","author":"Penggang","year":"2020","journal-title":"Adv. Eng. Sci."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Tian, Y., Zhang, P., Zhao, K., Du, Z., and Zhao, T. (2020). Application of Ag\/AgCl Sensor for Chloride Monitoring of Mortar under Dry-Wet Cycles. Sensors, 20.","DOI":"10.3390\/s20051394"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1007\/s10800-009-0029-6","article-title":"Potentiometric determination of the chloride ion activity in cement based materials","volume":"40","author":"Angst","year":"2010","journal-title":"J. Appl. Electrochem."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"2981","DOI":"10.1007\/s11581-015-1485-0","article-title":"Investigation on the performance characteristics of chloride selective electrode in concrete","volume":"21","author":"Jin","year":"2015","journal-title":"Ionics"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1002\/maco.200390095","article-title":"Non destructive determination of the free chloride content in cement based materials","volume":"54","author":"Elsener","year":"2003","journal-title":"Mater. Corros."},{"key":"ref_34","first-page":"211","article-title":"Preparation and properties of solid-state chloride ion selective electrode for detecting chloride ions in concrete","volume":"27","author":"Yongjing","year":"2015","journal-title":"Corros. Sci. Prot. Technol."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1016\/j.electacta.2017.07.152","article-title":"Simulated impedance of diffusion in porous media","volume":"251","author":"Cooper","year":"2017","journal-title":"Electrochim. Acta"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"10226","DOI":"10.3390\/s10111022","article-title":"Fabrication and performance of all-solid-state chloride sensors in synthetic concrete pore solutions","volume":"10","author":"Gao","year":"2010","journal-title":"Sensors"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"27049","DOI":"10.1039\/C8CP02450B","article-title":"Molecular dynamics study on ions and water confined in the nanometer channel of Friedel\u2019s salt: Structure, dynamics and interfacial interaction","volume":"20","author":"Penggang","year":"2018","journal-title":"Phys. Chem. Chem. Phys."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.conbuildmat.2008.02.004","article-title":"Chloride binding of cement-based materials subjected to external chloride environment\u2014A review","volume":"23","author":"Yuan","year":"2009","journal-title":"Constr. Build. Mater."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/7\/2149\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T14:19:32Z","timestamp":1760105972000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/7\/2149"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,27]]},"references-count":38,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2024,4]]}},"alternative-id":["s24072149"],"URL":"https:\/\/doi.org\/10.3390\/s24072149","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2024,3,27]]}}}