{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T17:43:17Z","timestamp":1779990197951,"version":"3.53.1"},"reference-count":35,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2024,4,7]],"date-time":"2024-04-07T00:00:00Z","timestamp":1712448000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000005","name":"Orthotic and Prosthetic Outcomes Research Program","doi-asserted-by":"publisher","award":["W81XWH1910835"],"award-info":[{"award-number":["W81XWH1910835"]}],"id":[{"id":"10.13039\/100000005","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The aim of this work was to assess the accuracy, repeatability, and reproducibility of a hand-held, structured-light 3D scanner (EINScan Pro 2X Plus with High Definition Prime Pack, SHINING 3D Tech. Co., Ltd., Hangzhou, China), to support its potential use in multi-site settings on lower limb prosthetics. Four limb models with different shapes were fabricated and scanned with a metrological 3D scanner (EINScan Laser FreeScan 5X, SHINING 3D Tech. Co., Ltd., Hangzhou, China) by a professional operator (OP0). Limb models were then mailed to three sites where two operators (OP1, OP2) scanned them using their own structured-light 3D scanner (same model). OP1 scanned limb models twice (OP1-A, OP1-B). OP0, OP1-A, and OP2 scans were compared for accuracy, OP1-A and OP1-B for repeatability, and OP1-A and OP2 for reproducibility. Among all comparisons, the mean radial error was &lt;0.25 mm, mean angular error was &lt;4\u00b0, and root mean square error of the radial distance was &lt;1 mm. Moreover, limits of agreement were &lt;3.5% for perimeters and volumes. By comparing these results with respect to clinically-relevant thresholds and to the literature available on other 3D scanners, we conclude that the EINScan Pro 2X Plus 3D Scanner with High Definition Prime Pack has good accuracy, repeatability, and reproducibility, supporting its use in multi-site settings.<\/jats:p>","DOI":"10.3390\/s24072350","type":"journal-article","created":{"date-parts":[[2024,4,8]],"date-time":"2024-04-08T06:04:58Z","timestamp":1712556298000},"page":"2350","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":20,"title":["Accuracy, Repeatability, and Reproducibility of a Hand-Held Structured-Light 3D Scanner across Multi-Site Settings in Lower Limb Prosthetics"],"prefix":"10.3390","volume":"24","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1301-4757","authenticated-orcid":false,"given":"Andrea Giovanni","family":"Cutti","sequence":"first","affiliation":[{"name":"INAIL, Via Rabuina 14, Vigorso di Budrio, 40054 Bologna, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-1142-9037","authenticated-orcid":false,"given":"Maria Grazia","family":"Santi","sequence":"additional","affiliation":[{"name":"Department of Industrial Engineering, University of Padova, 35131 Padova, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew H.","family":"Hansen","sequence":"additional","affiliation":[{"name":"Minneapolis VA Health Care System, One Veterans Drive, Minneapolis, MN 55417, USA"},{"name":"Department of Family Medicine and Community Health, Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN 55455, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5802-035X","authenticated-orcid":false,"given":"Stefania","family":"Fatone","sequence":"additional","affiliation":[{"name":"NUOPC, Department of Physical Medicine and Rehabilitation, Northwestern University, 680 N Lake Shore Dr, Suite 1100, Chicago, IL 60611, USA"},{"name":"Department of Rehabilitation Medicine, University of Washington, 1959 NE Pacific St., P.O. Box 356490, Seattle, WA 98195, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2024,4,7]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Vitali, A., Togni, G., Regazzoni, D., Rizzi, C., and Molinero, G. (2021). A virtual environment to evaluate the arm volume for lymphedema affected patients. Comput. Methods Programs Biomed., 198.","DOI":"10.1016\/j.cmpb.2020.105795"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1097\/00008526-198904000-00009","article-title":"Rectification maps: A new method for describing residual limb and socket shapes","volume":"1","author":"Sidles","year":"1989","journal-title":"J. Prosthet. Orthot."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1109\/86.547931","article-title":"A quantitative method for comparing and evaluating manual prosthetic socket modifications","volume":"4","author":"Lemaire","year":"1996","journal-title":"IEEE Trans. Rehabil. Eng."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"30","DOI":"10.3109\/03093649909071608","article-title":"Validation of a quantitative method for defining CAD\/CAM socket modifications","volume":"23","author":"Lemaire","year":"1999","journal-title":"Prosthet. Orthot. Int."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1177\/0309364616684165","article-title":"Quantification of rectifications for the Northwestern University Flexible Sub-Ischial Vacuum Socket","volume":"41","author":"Fatone","year":"2017","journal-title":"Prosthet. Orthot. Int."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1347","DOI":"10.1007\/s10237-019-01258-7","article-title":"Predictive prosthetic socket design: Part 2-generating person-specific candidate designs using multi-objective genetic algorithms","volume":"19","author":"Steer","year":"2020","journal-title":"Biomech. Model Mechanobiol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1331","DOI":"10.1007\/s10237-019-01195-5","article-title":"Predictive prosthetic socket design: Part 1-population-based evaluation of transtibial prosthetic sockets by FEA-driven surrogate modelling","volume":"19","author":"Steer","year":"2020","journal-title":"Biomech. Model Mechanobiol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"280","DOI":"10.3390\/prosthesis3040027","article-title":"Characterising residual limb morphology and prosthetic socket design based on expert clinician practice","volume":"3","author":"Dickinson","year":"2021","journal-title":"Prosthesis"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"854404","DOI":"10.3389\/fresc.2022.854404","article-title":"Limb prostheses: Industry 1.0 to 4.0: Perspectives on technological advances in prosthetic care","volume":"3","author":"Raschke","year":"2022","journal-title":"Front. Rehabil. Sci."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1097\/PXR.0000000000000157","article-title":"A qualitative study on stakeholder perceptions of digital prosthetic socket fabrication for transtibial amputations","volume":"46","author":"Mayo","year":"2022","journal-title":"Prosthet. Orthot. Int."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1007\/s00170-021-06778-0","article-title":"Comparison of geometrical accuracy of active devices for 3D orthopaedic reconstructions","volume":"114","author":"Redaelli","year":"2021","journal-title":"Int. J. Adv. Manuf. Technol."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Seminati, E., Canepa Talamas, D., Young, M., Twiste, M., Dhokia, V., and Bilzon, J. (2017). Validity and reliability of a novel 3D scanner for assessment of the shape and volume of amputees\u2019 residual limb models. PLoS ONE, 12.","DOI":"10.1371\/journal.pone.0184498"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1097\/PXR.0000000000000105","article-title":"Reliability of three different methods for assessing amputee residuum shape and volume: 3D scanners vs. circumferential measurements","volume":"46","author":"Seminati","year":"2022","journal-title":"Prosthet. Orthot. Int."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1682\/JRRD.2014.10.0272","article-title":"Registering methodology for imaging and analysis of residual-limb shape after transtibial amputation","volume":"53","author":"Dickinson","year":"2016","journal-title":"J. Rehabil. Res. Dev."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1097\/JPO.0000000000000350","article-title":"Selecting appropriate 3D scanning technologies for prosthetic socket design and transtibial residual limb shape characterization","volume":"34","author":"Dickinson","year":"2022","journal-title":"J. Prosthet. Orthot."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1177\/0309364617736088","article-title":"Measurement properties and usability of non-contact scanners for measuring transtibial residual limb volume","volume":"42","author":"Kofman","year":"2018","journal-title":"Prosthet. Orthot. Int."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1097\/PXR.0000000000000087","article-title":"Clinical usability, reliability, and repeatability of noncontact scanners in measuring residual limb volume in persons with transtibial amputation","volume":"46","author":"Kofman","year":"2022","journal-title":"Prosthet. Orthot. Int."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1177\/0309364616664150","article-title":"A smartphone photogrammetry method for digitizing prosthetic socket interiors","volume":"41","author":"Hernandez","year":"2017","journal-title":"Prosthet. Orthot. Int."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1682\/JRRD.2011.05.0097","article-title":"Computer-socket manufacturing error: How much before it is clinically apparent?","volume":"49","author":"Sanders","year":"2012","journal-title":"J. Rehabil. Res. Dev."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1177\/0954411918816124","article-title":"Comparative study of the circumferential and volumetric analysis between conventional casting and three-dimensional scanning methods for transtibial socket: A preliminary study","volume":"233","author":"Mehmood","year":"2019","journal-title":"Proc. Inst. Mech. Eng. Part H"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1002\/uog.5256","article-title":"Reliability, repeatability and reproducibility: Analysis of measurement errors in continuous variables","volume":"31","author":"Bartlett","year":"2008","journal-title":"Ultrasound Obstet. Gynecol."},{"key":"ref_22","unstructured":"Verein Deutscher Ingenieure, e.V. (2024, March 29). VDI\/VDE 2634, Optical 3D Measurement Systems\u2014Multiple View Systems Based on Area Scanning. 2008. Engl. VDI\/VDE-Gesellschaft Mess- und Automatisierungstechnik: Dusseldorf, Germany, Available online: https:\/\/www.vdi.de\/en\/home\/vdi-standards\/details\/vdivde-2634-blatt-3-optical-3d-measuring-systems-multiple-view-systems-based-on-area-scanning."},{"key":"ref_23","unstructured":"Cutti, A., Osti, G., Migliore, G., Cardin, D., Venturoli, F., and Verni, G. (2024, March 29). Clinical Effectiveness of a Novel Hydrostatic Casting Method for Transfemoral Amputees: Results from the First 64 Patients. Available online: http:\/\/oandpnews.org\/2018\/10\/31\/september-october-2018-research-clinical-effectiveness-of-a-novel-hydrostatic-casting-method-for-transfemoral-amputees-results-from-the-first-64-patients\/."},{"key":"ref_24","unstructured":"Fatone, S., and Cutti, A.G. (2024). Limb Model Scans [Dataset], Forthcoming."},{"key":"ref_25","first-page":"272","article-title":"Technique to assess shape captured by two casting approaches","volume":"47","author":"Cutti","year":"2023","journal-title":"Prosthet. Orthot. Int."},{"key":"ref_26","first-page":"129","article-title":"MeshLab: An open-source Mesh processing tool","volume":"1","author":"Cignoni","year":"2008","journal-title":"Computing"},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Schroeder, W., Martin, K., Lorensen, B., and Kitware Inc. (2006). The Visualization Toolkit: An Object-Oriented Approach to 3D Graphics, Kitware. Available online: https:\/\/books.google.it\/books?id=rx4vPwAACAAJ.","DOI":"10.1016\/B978-012387582-2\/50003-4"},{"key":"ref_28","unstructured":"Qt Company Ltd. (2023, June 21). Qt for Python. Available online: https:\/\/doc.qt.io\/qtforpython-6\/index.html#documentation."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1682\/JRRD.2004.05.0054","article-title":"Consistency and accuracy of measurement of lower-limb amputee anthropometrics","volume":"42","author":"Geil","year":"2005","journal-title":"J. Rehabil. Res. Dev."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"949","DOI":"10.1682\/JRRD.2010.09.0189","article-title":"Residual limb volume change: Systematic review of measurement and management","volume":"48","author":"Sanders","year":"2011","journal-title":"J. Rehabil. Res. Dev."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1002\/uog.122","article-title":"Applying the right statistics: Analyses of measurement studies","volume":"22","author":"Bland","year":"2003","journal-title":"Ultrasound Obstet. Gynecol."},{"key":"ref_32","unstructured":"Bland, M. (2000). An Introduction to Medical Statistics, Oxford University Press. [3rd ed.]."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1097\/00008526-199700920-00009","article-title":"Proper time for definitive transtibial prosthetic fitting","volume":"9","author":"Lilja","year":"1997","journal-title":"J. Prosthet. Orthot."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/j.medengphy.2017.03.003","article-title":"Effects of socket size on metrics of socket fit in trans-tibial prosthesis users","volume":"44","author":"Sanders","year":"2017","journal-title":"Med. Eng. Phys."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"13","DOI":"10.3109\/03093649909071606","article-title":"Relaxed versus activated stump muscles during casting for trans-tibial prostheses","volume":"23","author":"Lilja","year":"1999","journal-title":"Prosthet. Orthot. Int."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/7\/2350\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T14:24:28Z","timestamp":1760106268000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/7\/2350"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,7]]},"references-count":35,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2024,4]]}},"alternative-id":["s24072350"],"URL":"https:\/\/doi.org\/10.3390\/s24072350","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4,7]]}}}