{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,19]],"date-time":"2026-06-19T16:33:53Z","timestamp":1781886833521,"version":"3.54.5"},"reference-count":98,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2024,4,11]],"date-time":"2024-04-11T00:00:00Z","timestamp":1712793600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100012329","name":"European Partnership on Metrology","doi-asserted-by":"publisher","award":["22NRM06 ADMIT"],"award-info":[{"award-number":["22NRM06 ADMIT"]}],"id":[{"id":"10.13039\/100012329","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Since the integration of electronic devices and intelligent electronic devices into the power grid, power quality (PQ) has consistently remained a significant concern for system operators and experts. Maintaining high standards of power quality is crucial to preventing malfunctions and faults in electric assets and connected loads. Recently, PQ studies have shifted their focus to a specific frequency range, previously not considered problematic\u2014the supraharmonic 2 kHz to 150 kHz range. This range is not populated by easily recognizable harmonic components of the 50 Hz to 60 Hz mains fundamental, but by a combination of intentional emissions, switching non-linearities and byproducts, and various types of resonances. This paper aims to provide a detailed analysis of the impact of supraharmonics (SHs) on power network operation and assets, focusing on the most relevant documented negative effects, namely power loss and the heating of grid elements, aging of dielectric materials, failure of medium voltage (MV) cable terminations, and interference with equipment and power line communication (PLC) technology in particular. Under some shareable assumptions, limits are derived and compared to existing ones for harmonic phenomena, providing a clear identification of the primary issues associated with supraharmonics and suggestions for the standardization process. Strictly related is the problem of grid monitoring and assessment of SH distortion, discussing the suitability of normative requirements for instrument transformers (ITs) with a specific focus on their accuracy.<\/jats:p>","DOI":"10.3390\/s24082465","type":"journal-article","created":{"date-parts":[[2024,4,12]],"date-time":"2024-04-12T03:34:37Z","timestamp":1712892877000},"page":"2465","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":18,"title":["The Effects of Supraharmonic Distortion in MV and LV AC Grids"],"prefix":"10.3390","volume":"24","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0096-7305","authenticated-orcid":false,"given":"Andrea","family":"Mariscotti","sequence":"first","affiliation":[{"name":"Department of Electrical, Electronic and Telecommunications Engineering, and Naval Architecture (DITEN), University of Genova, 16145 Genova, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1739-1277","authenticated-orcid":false,"given":"Alessandro","family":"Mingotti","sequence":"additional","affiliation":[{"name":"Department of Electrical, Electronic, and Information Engineering (DEI), University of Bologna, 40136 Bologna, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2024,4,11]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1109\/TPWRD.2014.2326692","article-title":"Aggregation and Amplification of Wind-Turbine Harmonic Emission in a Wind Park","volume":"30","author":"Yang","year":"2015","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Novitskiy, A., Schlegel, S., and Westermann, D. (2019, January 12\u201315). Measurements and Analysis of Supraharmonic Influences in a MV\/LV Network Containing Renewable Energy Sources. Proceedings of the Electric Power Quality and Supply Reliability Conference (PQ) & Symposium on Electrical Engineering and Mechatronics (SEEM), K\u00e4rdla, Estonia.","DOI":"10.1109\/PQ.2019.8818259"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"105990","DOI":"10.1016\/j.epsr.2019.105990","article-title":"Development of high frequency (Supraharmonic) models of small-scale (<5 kW), single-phase, grid-tied PV inverters based on laboratory experiments","volume":"177","author":"Darmawardana","year":"2019","journal-title":"Electr. Power Syst. Res."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"2978","DOI":"10.1109\/TPWRD.2020.3031375","article-title":"Impact Assessment of High-Frequency Distortions Produced by PV Inverters","volume":"36","author":"Torquato","year":"2021","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Cassano, S., Silvestro, F., Jaeger, E.D., and Leroi, C. (2019, January 23\u201327). Modeling of harmonic propagation of fast DC EV charging station in a Low Voltage network. Proceedings of the 2019 IEEE Milan PowerTech, Milan, Italy.","DOI":"10.1109\/PTC.2019.8810969"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Chen, F., Zhong, Q., Zhang, H., Zhu, M., M\u00fcller, S., Meyer, J., and Huang, W. (2021, January 20\u201323). Survey of harmonic and supraharmonic emission of fast charging stations for electric vehicles in China and Germany. Proceedings of the 26th International Conference and Exhibition on Electricity Distribution (CIRED), Online Conference.","DOI":"10.1049\/icp.2021.1927"},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Alfieri, L., Bracale, A., Carpinelli, G., and Larsson, A. (2017, January 27\u201329). Accurate assessment of waveform distortions up to 150 kHz due to fluorescent lamps. Proceedings of the 2017 6th International Conference on Clean Electrical Power (ICCEP), Santa Margherita Ligure, Italy.","DOI":"10.1109\/ICCEP.2017.8004756"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1212","DOI":"10.1016\/j.egyr.2023.04.124","article-title":"Research on supraharmonic emission characteristics and influence factors of two-stage single-phase frequency converter","volume":"9","author":"Li","year":"2023","journal-title":"Energy Rep."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Gil-De-Castro, A., Medina-Gracia, R., Ronnberg, S., Blanco, A., and Meyer, J. (2018, January 13\u201316). Differences in the performance between CFL and LED lamps under different voltage distortions. Proceedings of the 18th International Conference on Harmonics and Quality of Power (ICHQP), Ljubljana, Slovenia.","DOI":"10.1109\/ICHQP.2018.8378918"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"11171","DOI":"10.1109\/TPEL.2019.2899176","article-title":"Interferences in AC\u2013DC LED Drivers Exposed to Voltage Disturbances in the Frequency Range 2\u2013150 kHz","volume":"34","author":"Sakar","year":"2019","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"5597","DOI":"10.1049\/iet-gtd.2019.0182","article-title":"Evaluation of supraharmonic emission levels of multiple grid-connected VSCs","volume":"13","author":"Wang","year":"2019","journal-title":"IET Gener. Transm. Distrib."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Bhagat, S., Mariscotti, A., Simonazzi, M., and Sandrolini, L. (2023, January 4\u20138). Variability of Conducted Emissions of EV Chargers due to Mutual Effects on a DC Grid. Proceedings of the 2023 International Symposium on Electromagnetic Compatibility\u2013EMC Europe, Krakow, Poland.","DOI":"10.1109\/EMCEurope57790.2023.10274375"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Mariscotti, A. (2021). Assessment of Human Exposure (Including Interference to Implantable Devices) to Low-Frequency Electromagnetic Field in Modern Microgrids, Power Systems and Electric Transports. Energies, 14.","DOI":"10.3390\/en14206789"},{"key":"ref_14","unstructured":"(2023). Electric Cables\u2014Calculation of the Current Rating. Part 1-1: Current Rating Equations (100% Load Factor) and Calculation of Losses\u2014General (Standard No. IEC 60287-1-1)."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Linde, T., Loh, J.T., Kornhuber, S., Backhaus, K., Schlegel, S., and Grossmann, S. (2021). Implications of Nonlinear Material Parameters on the Dielectric Loss under Harmonic Distorted Voltages. Energies, 14.","DOI":"10.3390\/en14030663"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1882","DOI":"10.1109\/TPWRD.2020.3016952","article-title":"Impact of High-Frequency Voltage Distortion Emitted by Large Photovoltaic Power Plant on Medium Voltage Cable Systems","volume":"36","author":"Knenicky","year":"2021","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_17","unstructured":"Sefl, O. (2021). Influence of Supraharmonics on Aging Rate of Polymeric Insulation Materials. [Ph.D. Thesis, Czech Technical University]."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Mariscotti, A. (2021). Power Quality Phenomena, Standards, and Proposed Metrics for DC Grids. Energies, 14.","DOI":"10.3390\/en14206453"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1689","DOI":"10.1109\/61.248274","article-title":"Pipe-type cable ampacities in the presence of harmonics","volume":"8","author":"Palmer","year":"1993","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1109\/OJIA.2020.2998000","article-title":"Failure of MV Cable Terminations Due to Supraharmonic Voltages: A Risk Indicator","volume":"1","author":"Letha","year":"2020","journal-title":"IEEE Open J. Ind. Appl."},{"key":"ref_21","unstructured":"Klatt, M., Kaiser, F., Meyer, J., Lakenbrink, C., and Gayner, C. (2019, January 3\u20136). Measurement and simulation of supraharmonic resonances in public Low Voltage networks. Proceedings of the 25th International Conference and Exhibition on Electricity Distribution (CIRED), Madrid, Spain."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Letha, S.S., Delgado, A.E., R\u00f6nnberg, S.K., and Bollen, M.H.J. (2021). Evaluation of Medium Voltage Network for Propagation of Supraharmonics Resonance. Energies, 14.","DOI":"10.3390\/en14041093"},{"key":"ref_23","unstructured":"Ronnberg, S., Wahlberg, M., Bollen, M., and Lundmark, C. (October, January 28). Equipment currents in the frequency range 9\u201395 kHz, measured in a realistic environment. Proceedings of the 13th International Conference on Harmonics and Quality of Power, Wollongong, Australia."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"106325","DOI":"10.1016\/j.epsr.2020.106325","article-title":"Summation law for supraharmonic currents (2\u2013150 kHz) in low-voltage installations","volume":"184","author":"Busatto","year":"2020","journal-title":"Electr. Power Syst. Res."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"6667","DOI":"10.1109\/TIM.2020.2992824","article-title":"The Role of Supply Conditions on the Measurement of High-Frequency Emissions","volume":"69","author":"Collin","year":"2020","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1501009","DOI":"10.1109\/TIM.2022.3162291","article-title":"Variability Caused by Setup and Operating Conditions for Conducted EMI of Switched Mode Power Supplies Over the 2\u20131000 kHz Interval","volume":"71","author":"Mariscotti","year":"2022","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"107179","DOI":"10.1016\/j.epsr.2021.107179","article-title":"Diagnosis of supraharmonics-related problems based on the effects on electrical equipment","volume":"195","author":"Letha","year":"2021","journal-title":"Electr. Power Syst. Res."},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Meyer, J., Khokhlov, V., Klatt, M., Blum, J., Waniek, C., Wohlfahrt, T., and Myrzik, J. (2018, January 20\u201322). Overview and Classification of Interferences in the Frequency Range 2\u2013150 kHz (Supraharmonics). Proceedings of the 2018 International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM), Amalfi, Italy.","DOI":"10.1109\/SPEEDAM.2018.8445344"},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Wang, D., Weyen, D., and Van Tichelen, P. (2023). Proposals for Updated EMC Standards and Requirements (9\u2013500 kHz) for DC Microgrids and New Compliance Verification Methods. Electronics, 12.","DOI":"10.3390\/electronics12143122"},{"key":"ref_30","unstructured":"(2019). Instrument Transformers\u2014Additional Requirements for Current Transformers for DC Applications (Standard No. IEC 61869-14)."},{"key":"ref_31","first-page":"07008","article-title":"Estimation of Power Losses Caused by Supraharmonics","volume":"209","author":"Novitskiy","year":"2020","journal-title":"EDP Sci."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1049\/ip-gtd:20000653","article-title":"Experimental investigation into harmonic impedance of low-voltage cables","volume":"147","author":"Du","year":"2000","journal-title":"IEE Proc.-Gener. Transm. Distrib."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"87","DOI":"10.15199\/48.2018.09.21","article-title":"Methods for determining power losses in cable lines with non-linear load","volume":"1","author":"Topolski","year":"2018","journal-title":"Przegl\u0105D Elektrotechniczny"},{"key":"ref_34","unstructured":"(2018). IEEE Recommended Practice for Establishing Liquid Immersed and Dry-Type Power and Distribution Transformer Capability When Supplying Nonsinusoidal Load Currents (Standard No. IEEE C57.110)."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1109\/TPWRD.2018.2882230","article-title":"High Accuracy Insulation Fault Diagnosis Method of Power Equipment Based on Power Maximum Likelihood Estimation","volume":"34","author":"Zhou","year":"2019","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"107440","DOI":"10.1016\/j.ijepes.2021.107440","article-title":"Investigation of supraharmonics\u2019 influence on partial discharge activity using an internal cavity sample","volume":"134","author":"Sefl","year":"2022","journal-title":"Int. J. Electr. Power Energy Syst."},{"key":"ref_37","unstructured":"(2015). Power Electronics Systems and Equipment\u2014Operation Conditions and Characteristics of Active Infeed Converter (AIC) Applications Including Design Recommendations for Their Emission Values Below 150 kHz (Standard No. IEC\/TS 62578)."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"1410","DOI":"10.1109\/TPWRD.2003.817724","article-title":"High-frequency impacts in a converter-based back-to-back tie; the Eagle Pass installation","volume":"18","author":"Paulsson","year":"2003","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_39","unstructured":"(2021). Industrial, Scientific and Medical Equipment\u2014Radio-Frequency Disturbance Characteristics\u2014Limits and Methods of Measurement (Standard No. EN 55011)."},{"key":"ref_40","unstructured":"(2020). Electromagnetic Compatibility of Multimedia Equipment\u2014Emission Requirements (Standard No. EN 55032)."},{"key":"ref_41","unstructured":"(2020). Electromagnetic Compatibility of Multimedia Equipment\u2014Immunity Requirements (Standard No. EN 55035)."},{"key":"ref_42","unstructured":"(2020). Electromagnetic Compatibility\u2014Part 6-1: Generic Standards\u2013Immunity Standard for Residential, Commercial and Light-Industrial Environments (Standard No. EN 61000-6-1)."},{"key":"ref_43","unstructured":"(2019). Electromagnetic Compatibility\u2014Part 6-2: Generic Standards\u2013Immunity Standard for Industrial Environments (Standard No. EN 61000-6-2)."},{"key":"ref_44","unstructured":"(2015). Specification for Radio Disturbance and Immunity Measuring Apparatus and Methods\u2014Part 1-1: Radio Disturbance and Immunity Measuring Apparatus\u2013Measuring Apparatus (Standard No. CISPR 16-1-1)."},{"key":"ref_45","unstructured":"(2014). Specification for Radio Disturbance and Immunity Measuring Apparatus and Methods\u2014Part 2-1: Methods of Measurement of Disturbances and Immunity\u2013Conducted Disturbance Measurements (Standard No. CISPR 16-2-1)."},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"Gil-de-Castro, A., Ronnberg, S.K., and Bollen, M.H.J. (2014, January 1\u20134). Harmonic interaction between an electric vehicle and different domestic equipment. Proceedings of the 2014 International Symposium on Electromagnetic Compatibility, Gothenburg, Sweden.","DOI":"10.1109\/EMCEurope.2014.6931047"},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Mariscotti, A., Sandrolini, L., and Simonazzi, M. (2022). Supraharmonic Emissions from DC Grid Connected Wireless Power Transfer Converters. Energies, 15.","DOI":"10.3390\/en15145229"},{"key":"ref_48","unstructured":"(2015). Study Report on Electromagnetic Interference between Electrical Equipment\/Systems in the Frequency Range Below 150 kHz (Standard No. CLC\/TR 50627)."},{"key":"ref_49","unstructured":"(2017). Investigation Results on Electromagnetic Interference in the Frequency Range below 150 kHz (Standard No. CLC\/TR 50669)."},{"key":"ref_50","doi-asserted-by":"crossref","unstructured":"Unger, C., Kruger, K., Sonnenschein, M., and Zurowski, R. (2005, January 6\u20139). Disturbances due to voltage distortion in the kHz range-experiences and mitigation measures. Proceedings of the 18th International Conference and Exhibition on Electricity Distribution (CIRED), Turin, Italy.","DOI":"10.1049\/cp:20051018"},{"key":"ref_51","doi-asserted-by":"crossref","unstructured":"Klatt, M., Meyer, J., Schegner, P., Koch, A., Myrzik, J., Eberl, G., and Darda, T. (2013, January 10\u201313). Emission levels above 2 kHz-Laboratory results and survey measurements in public low voltage grids. Proceedings of the 22nd International Conference and Exhibition on Electricity Distribution (CIRED 2013), Stockholm, Sweden.","DOI":"10.1049\/cp.2013.1102"},{"key":"ref_52","unstructured":"(2014). Electromagnetic Compatibility (EMC). Part 4-19: Testing and Measurement Techniques\u2014Test for Immunity to Conducted, Differential Mode Disturbances and Signalling in the Frequency Range 2 kHz to 150 kHz at a.c. Power Ports (Standard No. EN 61000-4-19)."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"496","DOI":"10.3390\/smartcities5020027","article-title":"Harmonic and Supraharmonic Emissions of Plug-In Electric Vehicle Chargers","volume":"5","author":"Mariscotti","year":"2022","journal-title":"Smart Cities"},{"key":"ref_54","unstructured":"(2021). Electromagnetic Compatibility\u2014Requirements for Household Appliances, Electric Tools and Similar Apparatus. Part 2: Immunity-Product Family Standard (Standard No. EN 55014-2)."},{"key":"ref_55","unstructured":"Tesla Motors Club (2024, April 07). Lights in House Flicker While Charging New Model 3. Available online: https:\/\/teslamotorsclub.com\/tmc\/threads\/lights-in-house-flicker-while-charging-new-model-3.149841\/."},{"key":"ref_56","doi-asserted-by":"crossref","unstructured":"Singh, G., Sharp, F., and Teh, W.Y. (July, January 28). Effects of Supraharmonics Immunity Testing on LED Lighting. Proceedings of the 2021 IEEE Madrid PowerTech, Madrid, Spain.","DOI":"10.1109\/PowerTech46648.2021.9494893"},{"key":"ref_57","unstructured":"Khokhlov, V., Meyer, J., Schegner, P., Agudelo-Mart\u00ednez, D., and Pavas, A. (2019, January 3\u20136). Immunity Assessment of Household Appliances in the Frequency Range from 2 to 150 kHz. Proceedings of the 25th International Conference and Exhibition on Electricity Distribution (CIRED), Madrid, Spain."},{"key":"ref_58","unstructured":"(2021). Electromagnetic Compatibility\u2014Requirements for Household Appliances, Electric Tools and Similar Apparatus. Part 1: Emission (Standard No. EN 55014-1)."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"2034","DOI":"10.1109\/TPWRD.2011.2130543","article-title":"Interaction Between Narrowband Power-Line Communication and End-User Equipment","volume":"26","author":"Ronnberg","year":"2011","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_60","doi-asserted-by":"crossref","unstructured":"Uribe-P\u00e9rez, N., Angulo, I., Hern\u00e1ndez-Callejo, L., Arzuaga, T., de la Vega, D., and Arrinda, A. (2016). Study of Unwanted Emissions in the CENELEC-A Band Generated by Distributed Energy Resources and Their Influence over Narrow Band Power Line Communications. Energies, 9.","DOI":"10.20944\/preprints201609.0108.v1"},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1109\/MEMC.2016.7866234","article-title":"Static energy meter errors caused by conducted electromagnetic interference","volume":"5","author":"Leferink","year":"2016","journal-title":"IEEE Electromagn. Compat. Mag."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"1629","DOI":"10.1109\/TPWRD.2012.2191423","article-title":"High-Frequency Behavior of Residual Current Devices","volume":"27","author":"Freschi","year":"2012","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"217","DOI":"10.2478\/mms-2014-0019","article-title":"Testing of Energy Meters Under Three-Phase Determined Furthermore, Random Nonsinusoidal Conditions","volume":"21","author":"Olencki","year":"2014","journal-title":"Metrol. Meas. Syst."},{"key":"ref_64","doi-asserted-by":"crossref","unstructured":"Shklyarskiy, Y., Hanzelka, Z., and Skamyin, A. (2020). Experimental Study of Harmonic Influence on Electrical Energy Metering. Energies, 13.","DOI":"10.3390\/en13215536"},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"67","DOI":"10.24084\/repqj19.216","article-title":"The Effects of High-Frequency Residual Currents on the Operation of Residual Current Devices","volume":"19","author":"Slangen","year":"2021","journal-title":"Renew. Energy Power Qual. J."},{"key":"ref_66","unstructured":"Bender (2024, April 07). MRCDB300 SeriesAC\/DC Sensitive Residual Current Monitoring Module. Available online: https:\/\/www.bender.de\/fileadmin\/content\/Products\/m\/e\/MRCDB300-series_D00343_M_XXEN.pdf."},{"key":"ref_67","unstructured":"(2022). General Safety Requirements for Residual Current Operated Protective Devices\u2014Part 1: Residual Current Operated Protective Devices for DC Systems (Standard No. IEC 60755-1)."},{"key":"ref_68","doi-asserted-by":"crossref","unstructured":"Schottke, S., Rademacher, S., Meyer, J., and Schegner, P. (2015, January 16\u201322). Transfer characteristic of a MV\/LV transformer in the frequency range between 2 kHz and 150 kHz. Proceedings of the 2015 IEEE International Symposium on Electromagnetic Compatibility (EMC), Dresden, Germany.","DOI":"10.1109\/ISEMC.2015.7256142"},{"key":"ref_69","doi-asserted-by":"crossref","unstructured":"Slangen, T., de Jong, E., Cuk, V., and Cobben, S. (2023, January 12\u201315). Transfer of supraharmonics through a MV\/LV transformer. Proceedings of the 27th International Conference on Electricity Distribution (CIRED 2023), Rome, Italy.","DOI":"10.1049\/icp.2023.0254"},{"key":"ref_70","doi-asserted-by":"crossref","unstructured":"Michalec, L., Kosty\u0142a, P., and Leonowicz, Z. (2022). Supraharmonic Pollution Emitted by Nonlinear Loads in Power Networks\u2014Ongoing Worldwide Research and Upcoming Challenges. Energies, 16.","DOI":"10.3390\/en16010273"},{"key":"ref_71","unstructured":"(2019). Electromagnetic Compatibility (EMC). Part 2-2: Environment\u2014Compatibility Levels for Low-Frequency Conducted Disturbances and Signalling in Public Low-Voltage Power Supply Systems (Standard No. EN 61000-2-2)."},{"key":"ref_72","unstructured":"(2003). Electromagnetic Compatibility (EMC). Part 2-12: Environment\u2014Compatibility Levels for Low-Frequency Conducted Disturbances and Signalling in Public Medium-Voltage Power Supply Systems (Standard No. EN 61000-2-12)."},{"key":"ref_73","unstructured":"(2020). Electromagnetic Compatibility (EMC). Part 2-4: Environment\u2014Compatibility Levels in Industrial Plants for Low-Frequency Conducted Disturbances (Standard No. EN 61000-2-4)."},{"key":"ref_74","unstructured":"(2009). Electromagnetic Compatibility (EMC)\u2013Part 4-7: Testing and Measurement Techniques\u2013General Guide on Harmonics and Interharmonics Measurements and Instrumentation, for Power Supply Systems and Equipment Connected Thereto (Standard No. IEC 61000-4-7)."},{"key":"ref_75","unstructured":"(2015). Electromagnetic Compatibility (EMC)\u2013Part 4-30: Testing and Measurement Techniques\u2013Power Quality Measurement Methods (Standard No. IEC 61000-4-30)."},{"key":"ref_76","doi-asserted-by":"crossref","unstructured":"Sandrolini, L., and Mariscotti, A. (2020). Signal Transformations for Analysis of Supraharmonic EMI Caused by Switched-Mode Power Supplies. Electronics, 9.","DOI":"10.3390\/electronics9122088"},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"107130","DOI":"10.1016\/j.epsr.2021.107130","article-title":"Impact of short-time fourier transform parameters on the accuracy of EMI spectra estimates in the 2\u2013150 kHz supraharmonic interval","volume":"195","author":"Sandrolini","year":"2021","journal-title":"Electr. Power Syst. Res."},{"key":"ref_78","doi-asserted-by":"crossref","unstructured":"Mariscotti, A. (2021). Critical Review of EMC Standards for the Measurement of Radiated Electromagnetic Emissions from Transit Line and Rolling Stock. Energies, 14.","DOI":"10.3390\/en14030759"},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"109011","DOI":"10.1016\/j.epsr.2022.109011","article-title":"On the suitability of the CISPR 16 method for measuring conducted emissions in the 2\u2013150kHz range in low voltage grids","volume":"216","author":"Lodetti","year":"2023","journal-title":"Electr. Power Syst. Res."},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"109213","DOI":"10.1016\/j.epsr.2023.109213","article-title":"Statistical relationship between RMS and QP spectra of voltage measurements in the 9\u2013150 kHz range","volume":"218","author":"Gallarreta","year":"2023","journal-title":"Electr. Power Syst. Res."},{"key":"ref_81","unstructured":"(2011). Signalling on Low-Voltage Electrical Installations in the Frequency Range 3 kHz to 148,5 kHz\u2014Part 1: General Requirements, Frequency Bands and Electromagnetic Disturbances (Standard No. EN 50065-1)."},{"key":"ref_82","unstructured":"(2019). Electromagnetic Compatibility (EMC). Part 3-2: Limits\u2014Limits for Harmonic Current Emissions (Equipment Input Current \u2264 16 A per Phase) (Standard No. EN 61000-3-2)."},{"key":"ref_83","unstructured":"(2019). Electromagnetic Compatibility (EMC). Part 3-12: Part 3-12: Limits\u2014Limits for Harmonic Currents Produced by Equipment Connected to Public Low-Voltage Systems with Input Current > 16 A and \u2264 75 A per Phase (Standard No. EN 61000-3-12)."},{"key":"ref_84","doi-asserted-by":"crossref","unstructured":"Lodetti, S., Bruna, J., Sanz, J.F., and Melero, J.J. (2019, January 2\u20134). Characterization of the Emission of an Electric Bus Inductive Charging in the 2 kHz to 150 kHz Range. Proceedings of the 2019 AEIT International Conference of Electrical and Electronic Technologies for Automotive (AEIT AUTOMOTIVE), Turin, Italy.","DOI":"10.23919\/EETA.2019.8804604"},{"key":"ref_85","unstructured":"(2023). Instrument Transformers\u2014General Requirements for Instrument Transformers (Standard No. IEC 61869-1)."},{"key":"ref_86","unstructured":"(2012). Instrument Transformers\u2014Additional Requirements for Current Transformers (Standard No. IEC 61869-2)."},{"key":"ref_87","unstructured":"(2011). Instrument Transformers\u2014Additional Requirements for Inductive Voltage Transformers (Standard No. IEC 61869-3)."},{"key":"ref_88","unstructured":"(2014). Instrument Transformers\u2014Additional Requirements for Combined Transformers (Standard No. IEC 61869-4)."},{"key":"ref_89","unstructured":"(2018). Instrument Transformers\u2014Additional Requirements for Low-Power Passive Voltage Transformers (Standard No. IEC 61869-11)."},{"key":"ref_90","unstructured":"(2011). Instrument Transformers\u2014Additional Requirements for Capacitive Voltage Transformers (Standard No. IEC 61869-5)."},{"key":"ref_91","unstructured":"(2016). Instrument Transformers\u2014Additional Requirements for Low-Power Instrument Transformers (Standard No. IEC 61869-6)."},{"key":"ref_92","unstructured":"(2019). Instrument Transformers\u2014Digital Interface for Instrument Transformers (Standard No. IEC 61869-9)."},{"key":"ref_93","unstructured":"(2018). Instrument Transformers\u2014Additional Requirements for Low-Power Passive Current Transformers (Standard No. IEC 61869-10)."},{"key":"ref_94","unstructured":"(2019). Instrument Transformers\u2014Additional Requirements for Voltage Transformers for DC Applications (Standard No. IEC 61869-15)."},{"key":"ref_95","doi-asserted-by":"crossref","unstructured":"Crotti, G., D\u2019Avanzo, G., Femine, A.D., Gallo, D., Giordano, D., Iodice, C., Landi, C., Letizia, P.S., Luiso, M., and Mazza, P. (2023, January 27\u201329). Characterization of Voltage Transformers for MV Applications Up to 150 kHz\u2014A Preliminary Study. Proceedings of the 2023 IEEE 13th International Workshop on Applied Measurements for Power Systems (AMPS), Bern, Switzerland.","DOI":"10.1109\/AMPS59207.2023.10297174"},{"key":"ref_96","doi-asserted-by":"crossref","unstructured":"Mingotti, A., Peretto, L., Tinarelli, R., Angioni, A., Monti, A., and Ponci, F. (2019). A Simple Calibration Procedure for an LPIT plus PMU System Under Off-Nominal Conditions. Energies, 12.","DOI":"10.3390\/en12244645"},{"key":"ref_97","doi-asserted-by":"crossref","unstructured":"Crotti, G., Giordano, D., Letizia, P., Signorino, D., Iodice, C., Luiso, M., Mazza, P., and Palladini, D. (2023, January 27\u201329). How Undesired Non-Idealities of the Input Signal Affect the Accuracy Evaluation of Instrument Transformers at Power Frequency. Proceedings of the 2023 IEEE 13th International Workshop on Applied Measurements for Power Systems (AMPS), Bern, Switzerland.","DOI":"10.1109\/AMPS59207.2023.10297244"},{"key":"ref_98","first-page":"9001312","article-title":"Theory and Experimental Validation of Two Techniques for Compensating VT Nonlinearities","volume":"71","author":"Faifer","year":"2022","journal-title":"IEEE Trans. Instrum. Meas."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/8\/2465\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T14:26:41Z","timestamp":1760106401000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/8\/2465"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,11]]},"references-count":98,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2024,4]]}},"alternative-id":["s24082465"],"URL":"https:\/\/doi.org\/10.3390\/s24082465","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4,11]]}}}