{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,27]],"date-time":"2026-01-27T22:44:26Z","timestamp":1769553866462,"version":"3.49.0"},"reference-count":25,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2024,6,17]],"date-time":"2024-06-17T00:00:00Z","timestamp":1718582400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This paper presents a fully automated experimental setup tailored for evaluating the effectiveness of augmented and virtual reality technologies in healthcare settings for regulatory purposes, with a focus on the characterization of depth sensors. The setup is constructed as a modular benchtop platform that enables quantitative analysis of depth cameras essential for extended reality technologies in a controlled environment. We detail a design concept and considerations for an experimental configuration aimed at simulating realistic scenarios for head-mounted displays. The system includes an observation platform equipped with a three-degree-of-freedom motorized system and a test object stage. To accurately replicate real-world scenarios, we utilized an array of sensors, including commonly available range-sensing cameras and commercial augmented reality headsets, notably the Intel RealSense L515 LiDAR camera, integrated into the motion control system. The paper elaborates on the system architecture and the automated data collection process. We discuss several evaluation studies performed with this setup, examining factors such as spatial resolution, Z-accuracy, and pixel-to-pixel correlation. These studies provide valuable insights into the precision and reliability of these technologies in simulated healthcare environments.<\/jats:p>","DOI":"10.3390\/s24123916","type":"journal-article","created":{"date-parts":[[2024,6,17]],"date-time":"2024-06-17T08:48:31Z","timestamp":1718614111000},"page":"3916","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Experimental Setup for Evaluating Depth Sensors in Augmented Reality Technologies Used in Medical Devices"],"prefix":"10.3390","volume":"24","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7202-6846","authenticated-orcid":false,"given":"Valentyn","family":"Stadnytskyi","sequence":"first","affiliation":[{"name":"Center for Devices and Radiological Health, U.S. Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA"}]},{"given":"Bahaa","family":"Ghammraoui","sequence":"additional","affiliation":[{"name":"Center for Devices and Radiological Health, U.S. Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA"}]}],"member":"1968","published-online":{"date-parts":[[2024,6,17]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Sutherland, I.E. (1968, January 9\u201311). A head-mounted three dimensional display. Proceedings of the AFIPS \u201968, San Francisco, CA, USA.","DOI":"10.1145\/1476589.1476686"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"36","DOI":"10.5772\/60091","article-title":"Recognition of Hand Gestures Observed by Depth Cameras","volume":"12","author":"Kapuscinski","year":"2015","journal-title":"Int. J. Adv. Robot. Syst."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1007\/s42979-023-01751-y","article-title":"An Exploration into Human\u2013Computer Interaction: Hand Gesture Recognition Management in a Challenging Environment","volume":"4","author":"Chang","year":"2023","journal-title":"SN Comput. Sci."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"2300207","DOI":"10.1002\/aisy.202300207","article-title":"A review of hand gesture recognition systems based on noninvasive wearable sensors","volume":"5","author":"Tchantchane","year":"2023","journal-title":"Adv. Intell. Syst."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1409","DOI":"10.1007\/s10278-022-00622-x","article-title":"Evaluation Challenges for the Application of Extended Reality Devices in Medicine","volume":"35","author":"Beams","year":"2022","journal-title":"J. Digit. Imaging"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Dennler, C., Bauer, D.E., Scheibler, A.G., Spirig, J., G\u00f6tschi, T., F\u00fcrnstahl, P., and Farshad, M. (2021). Augmented reality in the operating room: A clinical feasibility study. BMC Musculoskelet. Disord., 22.","DOI":"10.1186\/s12891-021-04339-w"},{"key":"ref_7","first-page":"6","article-title":"Intraoperative clinical application of augmented reality in neurosurgery: A systematic review","volume":"177","author":"Navarro","year":"2018","journal-title":"Clin. Neurol. Neurosurg."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"e2450","DOI":"10.1002\/rcs.2450","article-title":"The intraoperative use of augmented and mixed reality technology to improve surgical outcomes: A systematic review","volume":"18","author":"Bollen","year":"2022","journal-title":"Int. J. Med Robot. Comput. Assist. Surg."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"760","DOI":"10.1016\/j.amjsurg.2019.07.018","article-title":"Telemedicine and telementoring in the surgical specialties: A narrative review","volume":"218","author":"Huang","year":"2019","journal-title":"Am. J. Surg."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.janxdis.2018.08.003","article-title":"Virtual reality exposure therapy for anxiety and related disorders: A meta-analysis of randomized controlled trials","volume":"61","author":"Carl","year":"2019","journal-title":"J. Anxiety Disord."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1240","DOI":"10.1001\/jama.2016.2323","article-title":"Effect of mindfulness-based stress reduction vs cognitive behavioral therapy or usual care on back pain and functional limitations in adults with chronic low back pain: A randomized clinical trial","volume":"315","author":"Cherkin","year":"2016","journal-title":"JAMA"},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Spiegel, B., Fuller, G., Lopez, M., Dupuy, T., Noah, B., Howard, A., Albert, M., Tashjian, V., Lam, R., and Ahn, J. (2019). Virtual reality for management of pain in hospitalized patients: A randomized comparative effectiveness trial. PLoS ONE, 14.","DOI":"10.1371\/journal.pone.0219115"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Addison, A.P., Addison, P.S., Smit, P., Jacquel, D., and Borg, U.R. (2021). Noncontact Respiratory Monitoring Using Depth Sensing Cameras: A Review of Current Literature. Sensors, 21.","DOI":"10.3390\/s21041135"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Xavier Cejnog, L.W., Marcondes Cesar, R., de Campos, T.E., and Meirelles Carril Elui, V. (2019, January 14\u201318). Hand range of motion evaluation for Rheumatoid Arthritis patients. Proceedings of the 2019 14th IEEE International Conference on Automatic Face & Gesture Recognition (FG 2019), Lille, France.","DOI":"10.1109\/FG.2019.8756535"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Ricci, E., Rota Bul\u00f2, S., Snoek, C., Lanz, O., Messelodi, S., and Sebe, N. (2019). Automatic Segmentation Based on Deep Learning Techniques for Diabetic Foot Monitoring Through Multimodal Images. Image Analysis and Processing\u2014ICIAP 2019, Springer.","DOI":"10.1007\/978-3-030-30642-7"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1109","DOI":"10.1007\/s11548-023-02887-1","article-title":"Comparative evaluation of three commercially available markerless depth sensors for close-range use in surgical simulation","volume":"18","author":"Burger","year":"2023","journal-title":"Int. J. CARS"},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Al Farid, F., Hashim, N., Abdullah, J., Bhuiyan, M.R., Shahida Mohd Isa, W.N., Uddin, J., Haque, M.A., and Husen, M.N. (2022). A Structured and Methodological Review on Vision-Based Hand Gesture Recognition System. J. Imaging, 8.","DOI":"10.3390\/jimaging8060153"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"27076","DOI":"10.1364\/OE.26.027076","article-title":"Optical see-through holographic near-eye-display with eyebox steering and depth of field control","volume":"26","author":"Park","year":"2018","journal-title":"Opt. Express"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1145\/3355089.3356539","article-title":"Wirtinger holography for near-eye displays","volume":"38","author":"Chakravarthula","year":"2019","journal-title":"Acm Trans. Graph. (TOG)"},{"key":"ref_20","unstructured":"(2024, January 08). Intel\u00ae RealSense\u2122 LiDAR Camera L515 User Guide. Available online: https:\/\/support.intelrealsense.com\/hc\/en-us\/articles\/360051646094-Intel-RealSense-LiDAR-Camera-L515-User-Guide."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Herrera, C.D., Kannala, J., and Heikkil\u00e4, J. (2011). Accurate and Practical Calibration of a Depth and Color Camera Pair. Computer Analysis of Images and Patterns, Springer.","DOI":"10.1007\/978-3-642-23678-5_52"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Yu, J., Zhang, Y., Qi, B., Bai, X., Wu, W., and Liu, H. (2023). Analysis of the Slanted-Edge Measurement Method for the Modulation Transfer Function of Remote Sensing Cameras. Appl. Sci., 13.","DOI":"10.3390\/app132413191"},{"key":"ref_23","unstructured":"Granton, P. (2023, December 07). Slant Edge Script. MATLAB Central File Exchange. Available online: https:\/\/www.mathworks.com\/matlabcentral\/fileexchange\/28631-slant-edge-script."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"2332","DOI":"10.1093\/ckj\/sfab085","article-title":"Conducting correlation analysis: Important limitations and pitfalls","volume":"14","author":"Janse","year":"2021","journal-title":"Clin. Kidney J."},{"key":"ref_25","unstructured":"Zar, J.H. (1999). Biostatistical Analysis, Pearson Education."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/12\/3916\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T15:00:00Z","timestamp":1760108400000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/12\/3916"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,17]]},"references-count":25,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2024,6]]}},"alternative-id":["s24123916"],"URL":"https:\/\/doi.org\/10.3390\/s24123916","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,6,17]]}}}