{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T01:11:43Z","timestamp":1760145103579,"version":"build-2065373602"},"reference-count":34,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2024,6,20]],"date-time":"2024-06-20T00:00:00Z","timestamp":1718841600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Bio &amp; Medical Technology Development Program of the National Research Foundation (NRF) funded by the Korean government (MSIT)","award":["NRF-2022R1A2C1092176"],"award-info":[{"award-number":["NRF-2022R1A2C1092176"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This study addresses the limitations of current tonometry techniques by exploring vibroacoustic properties for estimating intraocular pressure (IOP), a key diagnostic parameter for monitoring glaucoma\u2014a significant risk factor for vision loss. Utilizing vivo porcine eyeballs, we investigated the relationship between IOP and the nonlinear vibration transfer function ratio (NVTFR). Through applying varying vibration levels and analyzing responses with transfer function analysis and univariate regression, we identified a strong negative correlation between NVTFR and IOP, evidenced by a Pearson correlation coefficient of \u22120.8111 and significant results from generalized linear model (GLM) regression (p-value &lt; 0.001). These findings indicate the potential of NVTFR as a vital indicator of IOP changes. Our study highlights the feasibility of using vibroacoustic properties, specifically NVTFR, to measure IOP. While further refinement is necessary for in vivo application, this approach opens new possibilities for non-invasive and patient-friendly IOP monitoring, potentially enhancing ophthalmology diagnostic techniques and providing a foundation for future research and development in this critical area.<\/jats:p>","DOI":"10.3390\/s24123997","type":"journal-article","created":{"date-parts":[[2024,6,20]],"date-time":"2024-06-20T05:27:19Z","timestamp":1718861239000},"page":"3997","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Exploring the Feasibility of Estimating Intraocular Pressure Using Vibrational Response of the Eye: A Methodological Approach"],"prefix":"10.3390","volume":"24","author":[{"given":"Seongwook","family":"Jeon","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, Hanyang University, Seoul 04763, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5556-8451","authenticated-orcid":false,"given":"Gyungmin","family":"Toh","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Hanyang University, Seoul 04763, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5628-3025","authenticated-orcid":false,"given":"Junhong","family":"Park","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Hanyang University, Seoul 04763, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3506-7139","authenticated-orcid":false,"given":"Won June","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Hanyang University College of Medicine, Seoul 04763, Republic of Korea"},{"name":"Department of Ophthalmology, Hanyang University Seoul Hospital, Seoul 04763, Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2024,6,20]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1090","DOI":"10.1001\/archopht.1991.01080080050026","article-title":"Relationship between intraocular pressure and primary open angle glaucoma among white and black Americans: The Baltimore Eye Survey","volume":"109","author":"Sommer","year":"1991","journal-title":"Arch. Ophthalmol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1136\/bjo.74.1.3","article-title":"Association between intraocular pressure and loss of visual field in chronic simple glaucoma","volume":"74","author":"Vogel","year":"1990","journal-title":"Br. J. Ophthalmol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"P41","DOI":"10.1016\/j.ophtha.2015.10.053","article-title":"Primary open-angle glaucoma preferred practice pattern\u00ae guidelines","volume":"123","author":"Prum","year":"2016","journal-title":"Ophthalmology"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1016\/0002-9394(58)90998-X","article-title":"The Goldmann applanation tonometer","volume":"46","author":"Moses","year":"1958","journal-title":"Am. J. Ophthalmol."},{"key":"ref_5","first-page":"1389","article-title":"Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer, and Tono-Pen","volume":"43","author":"Bhan","year":"2002","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1552","DOI":"10.1016\/j.ophtha.2012.02.030","article-title":"Systematic review of the agreement of tonometers with Goldmann applanation tonometry","volume":"119","author":"Cook","year":"2012","journal-title":"Ophthalmology"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1111\/j.1600-0420.2005.00610.x","article-title":"Clinical evaluation of rebound tonometer","volume":"84","author":"Davies","year":"2006","journal-title":"Acta Ophthalmol. Scand."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"4578","DOI":"10.1167\/iovs.05-0586","article-title":"Reproducibility and clinical evaluation of rebound tonometry","volume":"46","author":"Castillo","year":"2005","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1214","DOI":"10.1001\/archopht.1988.01060140374035","article-title":"The Tono-Pen: A manometric and clinical study","volume":"106","author":"Boothe","year":"1988","journal-title":"Arch. Ophthalmol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1007\/BF02028638","article-title":"Tono-Pen, a new tonometer","volume":"13","author":"Hessemer","year":"1989","journal-title":"Int. Ophthalmol."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1097\/ICU.0b013e3282f391ae","article-title":"New ways to measure intraocular pressure","volume":"19","author":"ElMallah","year":"2008","journal-title":"Curr. Opin. Ophthalmol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1097\/ICU.0000000000000129","article-title":"Measuring intraocular pressure","volume":"26","author":"Okafor","year":"2015","journal-title":"Curr. Opin. Ophthalmol."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"868","DOI":"10.1016\/j.ajo.2005.12.007","article-title":"Central corneal thickness and corneal hysteresis associated with glaucoma damage","volume":"141","author":"Congdon","year":"2006","journal-title":"Am. J. Ophthalmol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1137","DOI":"10.1001\/archopht.1997.01100160307007","article-title":"Central corneal thickness in normal, glaucomatous, and ocular hypertensive eyes","volume":"115","author":"Herndon","year":"1997","journal-title":"Arch. Ophthalmol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.survophthal.2012.05.003","article-title":"24-hour intraocular pressure and ocular perfusion pressure in glaucoma","volume":"58","author":"Quaranta","year":"2013","journal-title":"Surv. Ophthalmol."},{"key":"ref_16","first-page":"1519","article-title":"First-in-human continuous 24-hour measurement of intraocular pressure and ocular pulsation using a novel contact lens sensor","volume":"104","author":"Wasilewicz","year":"2020","journal-title":"Br. J. Ophthalmol."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/j.preteyeres.2016.07.002","article-title":"24-h monitoring devices and nyctohemeral rhythms of intraocular pressure","volume":"55","author":"Aptel","year":"2016","journal-title":"Prog. Retin. Eye Res."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"6801","DOI":"10.1038\/s41467-022-34597-8","article-title":"Wireless theranostic smart contact lens for monitoring and control of intraocular pressure in glaucoma","volume":"13","author":"Kim","year":"2022","journal-title":"Nat. Commun."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1038\/s41551-021-00719-8","article-title":"A soft and transparent contact lens for the wireless quantitative monitoring of intraocular pressure","volume":"5","author":"Kim","year":"2021","journal-title":"Nat. Biomed. Eng."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1245","DOI":"10.2147\/OPTH.S163092","article-title":"Icare\u00ae rebound tonometers: Review of their characteristics and ease of use","volume":"12","author":"Nakakura","year":"2018","journal-title":"Clin. Ophthalmol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1016\/j.jaapos.2011.10.005","article-title":"Home assessment of diurnal intraocular pressure in healthy children using the Icare rebound tonometer","volume":"16","author":"Hsiao","year":"2012","journal-title":"J. Am. Assoc. Pediatr. Ophthalmol. Strabismus"},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Man, X., Arroyo, E., Dunbar, M., Reed, D.M., Shah, N., Kagemann, L., Kim, W., Moroi, S.E., and Argento, A. (2018). Perilimbal sclera mechanical properties: Impact on intraocular pressure in porcine eyes. PLoS ONE, 13.","DOI":"10.1371\/journal.pone.0195882"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"3779","DOI":"10.1167\/iovs.18-24462","article-title":"Regional deformation of the optic nerve head and peripapillary sclera during IOP elevation","volume":"59","author":"Pavlatos","year":"2018","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1239","DOI":"10.1007\/s00417-019-04279-1","article-title":"Outflow facility and extent of angle closure in a porcine model","volume":"257","author":"Hong","year":"2019","journal-title":"Graefe\u2019s Arch. Clin. Exp. Ophthalmol."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Aloy, M., Adsuara, J.E., Cerd\u00e1-Dur\u00e1n, P., Obergaulinger, M., Esteve-Taboada, J.J., Ferrer-Blasco, T., and Mont\u00e9s-Mic\u00f3, R. (2017). Estimation of the mechanical properties of the eye through the study of its vibrational modes. PLoS ONE, 12.","DOI":"10.1371\/journal.pone.0183892"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1105","DOI":"10.1016\/0021-9290(92)90067-B","article-title":"A fluid-structure interaction problem in biomechanics: Prestressed vibrations of the eye by the finite element method","volume":"25","author":"Coquart","year":"1992","journal-title":"J. Biomech."},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Zhang, J., Zhang, Y., Li, Y., Chen, R., Shung, K.K., Richter, G., and Zhou, Q. (2017). Correlation of IOP with corneal acoustic impedance in porcine eye model. BioMed Res. Int., 2017.","DOI":"10.1155\/2017\/2959717"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1167\/iovs.10-5723","article-title":"Correlation of corneal acoustic and elastic properties in a canine eye model","volume":"52","author":"He","year":"2011","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1016\/j.ultras.2017.06.008","article-title":"Noninvasive measurement of wave speed of porcine cornea in ex vivo porcine eyes for various intraocular pressures","volume":"81","author":"Zhou","year":"2017","journal-title":"Ultrasonics"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1784","DOI":"10.1121\/1.4945733","article-title":"Resonance frequency of fluid-filled and prestressed spherical shell\u2014A model of the human eyeball","volume":"139","author":"Shih","year":"2016","journal-title":"J. Acoust. Soc. Am."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"20140920","DOI":"10.1098\/rsif.2014.0920","article-title":"Numerical model of optical coherence tomographic vibrography imaging to estimate corneal biomechanical properties","volume":"11","author":"Kling","year":"2014","journal-title":"J. R. Soc. Interface"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"663","DOI":"10.1111\/opo.12240","article-title":"A corneal elastic dynamic model derived from Scheimpflug imaging technology","volume":"35","author":"Shih","year":"2015","journal-title":"Ophthalmic Physiol. Opt."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1264","DOI":"10.1038\/s41598-020-80321-1","article-title":"A pilot study for intraocular pressure measurements based on vibroacoustic parameters","volume":"11","author":"Kim","year":"2021","journal-title":"Sci. Rep."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1115\/1.3143810","article-title":"Sound and Structural Vibration Radiation, Transmission and Response","volume":"108","author":"Fahy","year":"1986","journal-title":"J. Dyn. Syst. Meas. Control."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/12\/3997\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T15:01:33Z","timestamp":1760108493000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/12\/3997"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,20]]},"references-count":34,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2024,6]]}},"alternative-id":["s24123997"],"URL":"https:\/\/doi.org\/10.3390\/s24123997","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2024,6,20]]}}}