{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T01:15:18Z","timestamp":1760145318596,"version":"build-2065373602"},"reference-count":30,"publisher":"MDPI AG","issue":"13","license":[{"start":{"date-parts":[[2024,7,5]],"date-time":"2024-07-05T00:00:00Z","timestamp":1720137600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A new axially vibrating sensor based on an audio voice coil transducer and a lead zirconate titanate (PZT) piezoelectric disc microphone was developed as a probe for the measurement of in vitro rheological fluid properties, including curing progress for polymethylmethacrylate (PMMA) mixtures with important uses as bone cement in the field of orthopedics. The measurement of the vibrating axial sensor\u2019s acoustic spectra in PMMA undergoing curing can be described by a damped harmonic oscillator formalism and resonant frequency (ca. 180 Hz) shift can be used as an indicator of curing progress, with shifts to the blue by as much as 14 Hz. The resonant frequency peak was measured in 19 different 4.0 g PMMA samples to have a rate of shift of 0.0462 \u00b1 0.00624 Hz\u00b7s\u22121 over a period of 400 s while the PMMA was in a dough state and before the PMMA transitioned to a hard-setting phase. This transition is unambiguously indicated by this sensor technology through the generation of a distinct circa 5 kHz high-Q under-damped ring-down response.<\/jats:p>","DOI":"10.3390\/s24134365","type":"journal-article","created":{"date-parts":[[2024,7,5]],"date-time":"2024-07-05T12:30:59Z","timestamp":1720182659000},"page":"4365","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Cure State Sensing of Polymethylmethacrylate Using a Vibrating Axial Probe"],"prefix":"10.3390","volume":"24","author":[{"given":"Avonley","family":"Nguyen","sequence":"first","affiliation":[{"name":"RFA Systems, LLC., Aldie, VA 20105, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Quang V.","family":"Nguyen","sequence":"additional","affiliation":[{"name":"RFA Systems, LLC., Aldie, VA 20105, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5315-2647","authenticated-orcid":false,"given":"Daniel","family":"Funk","sequence":"additional","affiliation":[{"name":"WaveTest, LLC., Cincinnati, OH 45208, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2024,7,5]]},"reference":[{"doi-asserted-by":"crossref","unstructured":"Kuhn, K.D. (2000). Bone Cements, Springer.","key":"ref_1","DOI":"10.1007\/978-3-642-59762-6"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"851","DOI":"10.1302\/0301-620X.89B7.19148","article-title":"The role of polymethylmethacrylate bone cement in modern orthopaedic surgery","volume":"89","author":"Webb","year":"2007","journal-title":"J. Bone Jt. Surg."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"20130202","DOI":"10.1098\/rsta.2013.0202","article-title":"Experimentally simulating high-rate behavior: Rates and temperature effects in polycarbonate and PMMA","volume":"372","author":"Kendall","year":"2014","journal-title":"Phil. Trans. R. Soc. A"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"6280","DOI":"10.1007\/s10853-006-0506-9","article-title":"Quasi-static and dynamic compressive behavior of poly(methylmethacrylate) and polystyrene at temperatures from 293 K to 363 K","volume":"41","author":"Lee","year":"2006","journal-title":"J. Mater. Sci."},{"doi-asserted-by":"crossref","unstructured":"Szabelski, J., Karpinski, R., Krakowski, P., and Jonak, J. (2021). The Impact of Containing Poly (Methyl Methacrylate) (PMMA) Bone Cements on Their Compressive Strength. Materials, 14.","key":"ref_5","DOI":"10.3390\/ma14102555"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1186\/s13018-019-1080-6","article-title":"Oritavancin polymethylmethacrylate (PMMA)\u2014Compressive strength testing and in vitro elution","volume":"14","author":"Berglund","year":"2019","journal-title":"J. Orthop. Surg. Res."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1186\/s13018-021-02790-y","article-title":"Polymethyl methacrylate cure time in simulated in vivo total knee arthroplasty versus in vitro conditions","volume":"16","author":"Funk","year":"2021","journal-title":"J. Orthop. Surg. Res."},{"doi-asserted-by":"crossref","unstructured":"Sinha, D.N., and Olinger, C.T. (1996). Prototype Acoustic Resonance Spectroscopy Monitor, Los Alamos National Laboratory Publication No. LA-13132-MS (ISPO-385) UC-700.","key":"ref_8","DOI":"10.2172\/214266"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"E175","DOI":"10.1208\/pt070125","article-title":"Acoustic-Resonance Spectrometry as a Process Analytical Technology for Rapid and Accurate Tablet Identification","volume":"7","author":"Meddendorp","year":"2006","journal-title":"AAPS PharmSciTech"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"7425","DOI":"10.1002\/2015JB012297","article-title":"Theory and experiment of Differential Acoustic Resonance Spectroscopy","volume":"120","author":"Vogelaar","year":"2015","journal-title":"J. Geophys. Res. Solid Earth"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"3783","DOI":"10.3390\/ma6093783","article-title":"Monitoring the Cure State of Thermosetting Resins by Ultrasound","volume":"6","author":"Lionetto","year":"2013","journal-title":"Materials"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.polymertesting.2016.10.009","article-title":"Ultrasound monitoring of the cure kinetics of an epoxy resin: Identification, frequency and temperature dependence","volume":"56","author":"Ghodhbani","year":"2018","journal-title":"Polym. Test."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"012047","DOI":"10.1088\/1757-899X\/547\/1\/012047","article-title":"Elastic Modulus Determination of Thermoplastic Polymers with Pulse-Echo Method for Ultrasonic Testing","volume":"547","author":"Judawisastra","year":"2019","journal-title":"IOP Con. Ser. Mater. Sci. Eng."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"012001","DOI":"10.1088\/1361-6501\/ac2c4a","article-title":"Electromechanical resonators for sensing fluid density and viscosity\u2014A review","volume":"33","author":"Jakoby","year":"2022","journal-title":"Meas. Sci. Technol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"041907","DOI":"10.1063\/1.2837181","article-title":"Rheological behavior probed by vibrating microcantilevers","volume":"92","author":"Belmiloud","year":"2008","journal-title":"Appl. Phys. Lett."},{"unstructured":"Youssry, M., Caillard, B., Ayela, C., Pellet, C., and Dufour, I. (2010, January 1\u20133). Microrheology of Newtonian Fluids Using Microcantilevers. Proceedings of the Second IASTED International Conference on Nanotechnology Applications, NANA 2010, Cambridge, MA, USA.","key":"ref_16"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"697062","DOI":"10.1155\/2008\/697062","article-title":"Characterizing Vibrating Cantilevers for Liquid Viscosity and Density Sensing","volume":"2008","author":"Riesch","year":"2008","journal-title":"J. Sens."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/j.sna.2012.03.009","article-title":"Tunable resonators in the low kHz range for viscosity sensing","volume":"86","author":"Heinisch","year":"2012","journal-title":"Sens. Actuators A Phys."},{"key":"ref_19","first-page":"1743","article-title":"On modeling two-mode vibration sensors for combined density and viscosity measurements","volume":"15","author":"Wattinger","year":"2011","journal-title":"WIT Trans. Built Environ."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"719898","DOI":"10.1155\/2012\/719898","article-title":"The microcantilever: A Versatile Tool for Measuring the Rheological Properties of Complex Fluids","volume":"2012","author":"Dufour","year":"2012","journal-title":"J. Sens."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"084005","DOI":"10.1088\/0957-0233\/24\/8\/084005","article-title":"Comparison and experimental validation of two potential resonant viscosity sensors in the kHz range","volume":"24","author":"Lemaire","year":"2013","journal-title":"Meas. Sci. Technol."},{"doi-asserted-by":"crossref","unstructured":"Zhao, L., Hu, Y., Wang, T., Ding, J., Liu, X., Zhao, Y., and Jiang, Z. (2016). A MEMS Resonant Sensor to Measure Fluid Density and Viscosity under Flexural and Torsional Vibrating Modes. Sensors, 16.","key":"ref_22","DOI":"10.3390\/s16060830"},{"doi-asserted-by":"crossref","unstructured":"Kim, D., Hong, S., Jang, J., and Park, J. (2017). Determination of Fluid Density and Viscosity by Analyzing Flexural Wave Propagations on the Vibrating Micro-Cantilever. Sensors, 17.","key":"ref_23","DOI":"10.3390\/s17112466"},{"doi-asserted-by":"crossref","unstructured":"Gan, L., Choudhary, S., Reddy, K., Levine, C., Jandez, L., Uchil, A., and Puchades, I. (2024). Waterproofing a Thermally Actuated Vibrational MEMS Viscosity Sensor. Actuators, 13.","key":"ref_24","DOI":"10.20944\/preprints202401.1532.v1"},{"unstructured":"Anuta, D.A. (1982). Low Viscosity Bone Cement. (4341691), U.S. Patent.","key":"ref_25"},{"key":"ref_26","first-page":"382","article-title":"Loudspeakers in Vented Boxes","volume":"19","author":"Thiele","year":"1971","journal-title":"J. Audio Engr. Soc."},{"key":"ref_27","first-page":"383","article-title":"Direct Radiator Loudspeaker Analysis","volume":"20","author":"Small","year":"1972","journal-title":"J. Audio Engr. Soc."},{"unstructured":"Chong, Y.D. (2024, January 03). Complex Methods for the Sciences. Available online: https:\/\/phys.libretexts.org\/Bookshelves\/Mathematical_Physics_and_Pedagogy\/Complex_Methods_for_the_Sciences_(Chong).","key":"ref_28"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1122\/1.2188567","article-title":"The effect of the shear-thickening transition of model colloidal spheres on the sign of N1 and on the radial pressure profile in torsional shear flows","volume":"50","author":"Lee","year":"2006","journal-title":"J. Rheol."},{"unstructured":"(2002). Implants for Surgery\u2014Acrylic Resin Cements (Standard No. ISO 5833:2002). Available online: https:\/\/www.iso.org\/standard\/30980.html.","key":"ref_30"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/13\/4365\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T15:10:37Z","timestamp":1760109037000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/13\/4365"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,5]]},"references-count":30,"journal-issue":{"issue":"13","published-online":{"date-parts":[[2024,7]]}},"alternative-id":["s24134365"],"URL":"https:\/\/doi.org\/10.3390\/s24134365","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2024,7,5]]}}}