{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,14]],"date-time":"2026-02-14T20:59:16Z","timestamp":1771102756760,"version":"3.50.1"},"reference-count":34,"publisher":"MDPI AG","issue":"17","license":[{"start":{"date-parts":[[2024,9,5]],"date-time":"2024-09-05T00:00:00Z","timestamp":1725494400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"French National Centre for Scientific Research"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This study addresses the need for highly sensitive tools to evaluate hand strength, particularly grasp and pinch strength, which are vital for diagnosing and rehabilitating conditions affecting hand function. Current devices like the Jamar dynamometer and Martin Vigorimeter, although reliable, fail to measure extremely low force or pressure values required for individuals with severe hand impairments. This research introduces a novel device, a modified Martin Vigorimeter, utilizing an ultra-soft latex chamber and differential pressure measurement to detect minute pressure changes, thus significantly enhancing sensitivity. The device offers a cost-effective solution, making advanced hand strength evaluation more accessible for clinical and research applications. Future research should validate its accuracy across diverse populations and settings, exploring its broader implications for hand rehabilitation and occupational health.<\/jats:p>","DOI":"10.3390\/s24175768","type":"journal-article","created":{"date-parts":[[2024,9,5]],"date-time":"2024-09-05T04:15:11Z","timestamp":1725509711000},"page":"5768","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Pressure Sensors for Evaluating Hand Grasp and Pinch"],"prefix":"10.3390","volume":"24","author":[{"given":"Vance","family":"Bergeron","sequence":"first","affiliation":[{"name":"Laboratoire de Physique, University of Lyon, ENS de Lyon, CNRS, F-69342 Lyon, France"}]},{"given":"Petar","family":"Kajganic","sequence":"additional","affiliation":[{"name":"Laboratoire de Physique, University of Lyon, ENS de Lyon, CNRS, F-69342 Lyon, France"}]}],"member":"1968","published-online":{"date-parts":[[2024,9,5]]},"reference":[{"key":"ref_1","first-page":"69","article-title":"Grip and Pinch Strength: Normative Data for Adults","volume":"66","author":"Mathiowetz","year":"1985","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1046\/j.1440-1630.1999.00182.x","article-title":"Handgrip Strength Testing: A Review of the Literature","volume":"46","author":"Innes","year":"1999","journal-title":"Aust. Occup. Ther. J."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"665","DOI":"10.1016\/0363-5023(94)90280-1","article-title":"Hand Strength: Normative Values","volume":"19","author":"Crosby","year":"1994","journal-title":"J. Hand Surg. Am."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1002\/oti.165","article-title":"Comparison of Rolyan and Jamar Dynamometers for Measuring Grip Strength","volume":"9","author":"Mathiowetz","year":"2002","journal-title":"Occup. Ther. Int."},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Hogrel, J.-Y. (2015). Grip Strength Measured by High Precision Dynamometry in Healthy Subjects from 5 to 80 Years. BMC Musculoskelet. Disord., 16.","DOI":"10.1186\/s12891-015-0612-4"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Lee, S.-C., Wu, L.-C., Chiang, S.-L., Lu, L.-H., Chen, C.-Y., Lin, C.-H., Ni, C.-H., and Lin, C.-H. (2020). Validating the Capability for Measuring Age-Related Changes in Grip-Force Strength Using a Digital Hand-Held Dynamometer in Healthy Young and Elderly Adults. BioMed Res. Int., 2020.","DOI":"10.1155\/2020\/6936879"},{"key":"ref_7","unstructured":"Fess, E., and Moran, C. (1981). American Society of Hand Therapists Clinical Assessment Recommendations, American Society of Hand Therapists."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1197\/j.jht.2005.07.003","article-title":"Test-Retest Reliability of Grip-Strength Measures Obtained over a 12-Week Interval from Community-Dwelling Elders","volume":"18","author":"Bohannon","year":"2005","journal-title":"J. Hand Ther."},{"key":"ref_9","first-page":"2","article-title":"A Review on Grip and Pinch Strength Tests","volume":"7","author":"Mohammadian","year":"2023","journal-title":"Ergon. Int. J."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"248","DOI":"10.2340\/16501977-2530","article-title":"Development of Grip Strength during the First Year after Stroke","volume":"51","author":"Stock","year":"2019","journal-title":"J. Rehabil. Med."},{"key":"ref_11","unstructured":"(2024, July 20). Baseline\u00ae Measurement-Fabrication Enterprises. Available online: https:\/\/www.fab-ent.com\/brands\/baseline\/."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1016\/S0894-1130(12)80326-7","article-title":"Accuracy of the Jamar Dynamometer","volume":"6","author":"Harju","year":"1993","journal-title":"J. Hand Ther."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"466.e1","DOI":"10.1016\/j.jamda.2016.02.026","article-title":"The Martin Vigorimeter Represents a Reliable and More Practical Tool Than the Jamar Dynamometer to Assess Handgrip Strength in the Geriatric Patient","volume":"17","author":"Sipers","year":"2016","journal-title":"J. Am. Med. Dir. Assoc."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/j.exger.2018.07.004","article-title":"Martin Vigorimeter Assesses Muscle Fatigability in Older Adults Better than the Jamar Dynamometer","volume":"111","author":"Theou","year":"2018","journal-title":"Exp. Gerontol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1016\/S8756-3282(02)00919-5","article-title":"Independent Predictors of All Osteoporosis-Related Fractures in Healthy Postmenopausal Women: The OFELY Study","volume":"32","author":"Albrand","year":"2003","journal-title":"Bone"},{"key":"ref_16","first-page":"1313","article-title":"Strength and Function in the Normal and Rheumatoid Hand","volume":"18","author":"Jones","year":"1991","journal-title":"J. Rheumatol."},{"key":"ref_17","first-page":"917","article-title":"Comparison of the Grip Strength Using the Martin-Vigorimeter and the JAMAR-Dynamometer: Establishment of Normal Values","volume":"31","author":"Neumann","year":"2017","journal-title":"In Vivo"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"137","DOI":"10.2340\/165019771995137143","article-title":"Comparison of the Jamar Dynamometer and the Martin Vigorimeter for Grip Strength Measurements in a Healthy Elderly Population","volume":"27","author":"Desrosiers","year":"1995","journal-title":"J. Rehabil. Med."},{"key":"ref_19","unstructured":"(2024, July 14). Fabrication Enterprises Inc. Available online: https:\/\/www.fab-ent.com\/evaluation\/strength\/baseline-pneumatic-squeeze-bulb-dynamometers\/."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1111\/ggi.12508","article-title":"Prognostic Value of Handgrip Strength in People Aged 60 Years and Older: A Systematic Review and Meta-Analysis","volume":"16","author":"Rijk","year":"2016","journal-title":"Geriatr. Gerontol. Int."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Benton, M.J., Spicher, J.M., and Silva-Smith, A.L. (2022). Validity and Reliability of Handgrip Dynamometry in Older Adults: A Comparison of Two Widely Used Dynamometers. PLoS ONE, 17.","DOI":"10.1371\/journal.pone.0270132"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1197\/j.jht.2005.04.002","article-title":"Reliability and Validity of the DynEx Dynamometer","volume":"18","author":"Shechtman","year":"2005","journal-title":"J. Hand Ther."},{"key":"ref_23","unstructured":"(2024, July 14). Fabrication Enterprises Inc. Available online: https:\/\/www.fab-ent.com\/evaluation\/strength\/baseline-mechanical-pinch-gauges\/."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1016\/j.jht.2020.03.007","article-title":"Normative Data for the Baseline\u00ae 5 Position Hydraulic Pinch Meter and the Relationship between Lateral Pinch Strength and Pinch Span","volume":"34","author":"Hock","year":"2021","journal-title":"J. Hand Ther."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"37","DOI":"10.5958\/2394-2800.2022.00008.6","article-title":"Normative Values of Hand Grip Strength and Pinch Grip Strength in Healthy Children","volume":"9","author":"Kotecha","year":"2022","journal-title":"Indian J. Health Sci. Care"},{"key":"ref_26","unstructured":"(2024, July 14). Fabrication Enterprises Inc. Available online: https:\/\/www.fab-ent.com\/evaluation\/strength\/baseline-electronic-pinch-gauges\/."},{"key":"ref_27","unstructured":"(2024, July 14). Biometrics Ltd. Available online: https:\/\/www.biometricsltd.com\/hand-therapy.htm."},{"key":"ref_28","unstructured":"(2024, July 14). Noraxon. Available online: https:\/\/www.noraxon.com\/our-products\/."},{"key":"ref_29","unstructured":"(2024, July 14). Novel. Available online: https:\/\/www.novelusa.com\/index.php."},{"key":"ref_30","unstructured":"(2024, July 14). Tekscan. Available online: https:\/\/www.tekscan.com\/products-solutions\/sensors."},{"key":"ref_31","unstructured":"(2024, July 14). Tekscan. Available online: https:\/\/www.tekscan.com\/products-solutions\/systems\/grip-system."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1080\/14763141.2017.1355010","article-title":"Test\u2013Retest Reliability of the Tekscan\u00ae F-Scan\u00ae 7 in-Shoe Plantar Pressure System during Treadmill Walking in Healthy Recreationally Active Individuals","volume":"17","author":"Patrick","year":"2017","journal-title":"Sports Biomech."},{"key":"ref_33","doi-asserted-by":"crossref","unstructured":"Woodburn, J., and Helliwell, P.S. (1997). Observations on the F-Scan in-Shoe Pressure Measuring System. Clin. Biomech., 12.","DOI":"10.1016\/S0268-0033(97)88329-5"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1515\/folmed-2016-0015","article-title":"The T-SCAN System in Evaluating Occlusal Contacts","volume":"58","author":"Bozhkova","year":"2016","journal-title":"Folia Med."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/17\/5768\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T15:48:54Z","timestamp":1760111334000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/17\/5768"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,5]]},"references-count":34,"journal-issue":{"issue":"17","published-online":{"date-parts":[[2024,9]]}},"alternative-id":["s24175768"],"URL":"https:\/\/doi.org\/10.3390\/s24175768","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,9,5]]}}}