{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,25]],"date-time":"2026-07-25T11:27:07Z","timestamp":1784978827968,"version":"3.55.0"},"reference-count":32,"publisher":"MDPI AG","issue":"18","license":[{"start":{"date-parts":[[2024,9,10]],"date-time":"2024-09-10T00:00:00Z","timestamp":1725926400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>In non-invasive blood glucose measurement, the sensitivity of glucose-induced optical signals within human tissue is a crucial reference point. This study evaluates the sensitivity of glucose-induced diffuse reflectance in the 1000\u20131700 nm range. A key factor in understanding this sensitivity is the rate at which the scattering coefficient changes due to glucose, as it is significantly higher than in non-living media and predominantly influences the diffuse light signal level when blood glucose levels change. The study measured and calculated the changes in the scattering coefficient at 1314 nm, a wavelength chosen for its minimal interference from glucose absorption and other bodily constituents. Based on the Mie scattering theory and the results at 1314 nm, the changes in the scattering coefficient within the 1000\u20131700 nm range were estimated. Subsequently, the sensitivity of the glucose signal across this range was determined through Monte Carlo (MC) simulations. The findings from 25 human trials indicate that the measured sensitivities at five other typical wavelengths within this band generally align with the sensitivities calculated using the aforementioned method. This research can guide the identification of blood glucose signals and the selection of wavelengths for non-invasive blood glucose measurements.<\/jats:p>","DOI":"10.3390\/s24185879","type":"journal-article","created":{"date-parts":[[2024,9,10]],"date-time":"2024-09-10T10:20:10Z","timestamp":1725963610000},"page":"5879","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Evaluation and Validation on Sensitivity of Near-Infrared Diffuse Reflectance in Non-Invasive Human Blood Glucose Measurement"],"prefix":"10.3390","volume":"24","author":[{"given":"Qing","family":"Ge","sequence":"first","affiliation":[{"name":"State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tongshuai","family":"Han","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rong","family":"Liu","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zengfu","family":"Zhang","sequence":"additional","affiliation":[{"name":"Sunrise Technology Co., Ltd., Tianjin 300192, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Di","family":"Sun","sequence":"additional","affiliation":[{"name":"Sunrise Technology Co., Ltd., Tianjin 300192, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin","family":"Liu","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2714-0308","authenticated-orcid":false,"given":"Kexin","family":"Xu","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2024,9,10]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1909","DOI":"10.1007\/s10103-017-2317-4","article-title":"Effect of wavelength and beam width on penetration in light-tissue interaction using computational methods","volume":"32","author":"Ash","year":"2017","journal-title":"Lasers Med. Sci."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Alsunaidi, B., Althobaiti, M., Tamal, M., Albaker, W., and Al-Naib, I. (2021). A review of non-invasive optical systems for continuous blood glucose monitoring. Sensors, 21.","DOI":"10.3390\/s21206820"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1016\/j.bspc.2015.01.005","article-title":"Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy","volume":"18","author":"Yadav","year":"2015","journal-title":"Biomed. Signal Process. Control"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1109\/TCE.2020.3011966","article-title":"iGLU 2.0: A new wearable for accurate non-invasive continuous serum glucose measurement in IoMT framework","volume":"66","author":"Joshi","year":"2020","journal-title":"IEEE Trans. Consum. Electron."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1236","DOI":"10.1366\/000370203769699090","article-title":"In vivo Noninvasive Measurement of Blood Glucose by Near-Infrared Diffuse-Reflectance Spectroscopy","volume":"57","author":"Maruo","year":"2003","journal-title":"Appl. Spectrosc."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Srichan, C., Srichan, W., Danvirutai, P., Ritsongmuang, C., Sharma, A., and Anutrakulchai, S. (2020). Non-invasively accuracy enhanced blood glucose sensor using shallow dense neural networks with NIR monitoring and medical features. Sci. Rep., 12.","DOI":"10.1038\/s41598-022-05570-8"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1177\/193229680700100402","article-title":"Selectivity assessment of noninvasive glucose measurements based on analysis of multivariate calibration vectors","volume":"1","author":"Arnold","year":"2007","journal-title":"J. Diabetes Sci. Technol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1100","DOI":"10.1177\/00037028221092474","article-title":"In vivo Near-infrared noninvasive glucose measurement and detection in humans","volume":"76","author":"Han","year":"2022","journal-title":"Appl. Spectrosc."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/0169-2607(95)01640-F","article-title":"MCML\u2014Monte Carlo modeling of light transport in multi-layered tissues","volume":"47","author":"Wang","year":"1995","journal-title":"Comput. Methods Programs Biomed."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Zhu, C., and Liu, Q. (2013). Review of Monte Carlo modeling of light transport in tissues. J. Biomed. Opt., 18.","DOI":"10.1117\/1.JBO.18.5.050902"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1016\/S0263-2241(98)00054-2","article-title":"Non-invasive glucose measurement based on selective near infrared absorption; requirements on instrumentation and spectral range","volume":"24","author":"Tenhunen","year":"1998","journal-title":"Measurement"},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Larin, K.V., Motamedi, M., Ashitkov, T.V., and Esenaliev, R.O. (2003). Specificity of noninvasive blood glucose sensing using optical coherence tomography technique: A pilot study. Phys. Med. Biol., 48.","DOI":"10.1088\/0031-9155\/48\/10\/310"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Kohl, M., Essenpreis, M., and Cope, M. (1995). The influence of glucose concentration upon the transport of light in tissue-simulating phantoms. Phys. Med. Biol., 40.","DOI":"10.1088\/0031-9155\/40\/7\/009"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1364\/OL.22.000190","article-title":"Correlation between blood glucose concentration in diabetics and noninvasively measured tissue optical scattering coefficient","volume":"22","author":"Bruulsema","year":"1997","journal-title":"Opt. Lett."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"2251","DOI":"10.1364\/AO.45.002251","article-title":"In vitro studies toward noninvasive glucose monitoring with optical coherence tomography","volume":"45","author":"Kinnunen","year":"2006","journal-title":"Appl. Opt."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"2263","DOI":"10.2337\/diacare.25.12.2263","article-title":"Noninvasive blood glucose monitoring with optical coherence tomography: A pilot study in human subjects","volume":"25","author":"Larin","year":"2002","journal-title":"Diabetes Care"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"2062","DOI":"10.1364\/OL.19.002062","article-title":"Possible correlation between blood glucose concentration and the reduced scattering coefficient of tissues in the near infrared","volume":"19","author":"Maier","year":"1994","journal-title":"Opt. Lett."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1313","DOI":"10.1366\/14-07728","article-title":"Accuracy of noninvasive glucose sensing based on near-infrared spectroscopy","volume":"69","author":"Liu","year":"2015","journal-title":"Appl. Spectrosc."},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Shen, H., and Wang, G. (2010). A tetrahedron-based inhomogeneous Monte Carlo optical simulator. Phys. Med. Biol., 55.","DOI":"10.1088\/0031-9155\/55\/4\/003"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1007\/s10043-003-0600-z","article-title":"Monte Carlo simulation of near infrared reflectance spectroscopy in the wavelength range from 1000 nm to 1900 nm","volume":"10","author":"Iino","year":"2003","journal-title":"Opt. Rev."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1117\/12.281502","article-title":"Light propagation in tissues with controlled optical properties","volume":"2","author":"Tuchin","year":"1997","journal-title":"J. Biomed. Opt."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Tarumi, M., Shimada, M., Murakami, T., Tamura, M., Shimada, M., Arimoto, H., and Yamada, Y. (2003). Simulation study of in vitro glucose measurement by NIR spectroscopy and a method of error reduction. Phys. Med. Biol., 48.","DOI":"10.1088\/0031-9155\/48\/15\/309"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1255\/jnirs.32","article-title":"Spectrophotometry of human hemoglobin in the near infrared region from 1000 to 2500 nm","volume":"2","author":"Kuenstner","year":"1994","journal-title":"J. Near Infrared Spectrosc."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"192","DOI":"10.3390\/rs16010192","article-title":"Measuring pure water absorption coefficient in the near-infrared spectrum (900\u20132500 nm)","volume":"16","author":"Deng","year":"2012","journal-title":"J. Remote Sens."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Iorizzo, T., Jermain, P., Salomatina, E., Muzikansky, A., and Yaroslavsky, A. (2021). Temperature induced changes in the optical properties of skin in vivo. Sci. Rep., 11.","DOI":"10.1038\/s41598-020-80254-9"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1117\/1.1344191","article-title":"Optical properties of human skin in the near infrared wavelength range of 1000 to 2200 nm","volume":"6","author":"Troy","year":"2001","journal-title":"J. Biomed. Opt."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1195","DOI":"10.1366\/0003702042336136","article-title":"Molar absorptivities of glucose and other biological molecules in aqueous solutions over the first overtone and combination regions of the near-infrared spectrum","volume":"58","author":"Amerov","year":"2004","journal-title":"Appl. Spectrosc."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"879","DOI":"10.1007\/s00216-006-1047-4","article-title":"Comparison of multivariate calibration models for glucose, urea, and lactate from near-infrared and Raman spectra","volume":"387","author":"Ren","year":"2007","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1364\/BOE.506092","article-title":"High-accuracy noninvasive continuous glucose monitoring using OCT angiography-purified blood scattering signals in human skin","volume":"15","author":"Gao","year":"2024","journal-title":"Biomed. Opt. Express"},{"key":"ref_30","first-page":"117","article-title":"Discussion on floating-reference method for noninvasive measurement of blood glucose with near-infrared spectroscopy","volume":"6094","author":"Luo","year":"2006","journal-title":"Proc. SPIE"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1007\/s10765-019-2515-3","article-title":"In vivo measurement of optical properties of human skin for 450\u2013800 nm and 950\u20131600 nm wavelengths","volume":"40","author":"Kono","year":"2019","journal-title":"Int. J. Thermophys."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1111\/j.1600-0846.2009.00410.x","article-title":"In vivo measurement of the water content in the dermis by confocal Raman spectroscopy","volume":"16","author":"Nakagawa","year":"2010","journal-title":"Ski. Res. Technol."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/18\/5879\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T15:53:12Z","timestamp":1760111592000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/18\/5879"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,10]]},"references-count":32,"journal-issue":{"issue":"18","published-online":{"date-parts":[[2024,9]]}},"alternative-id":["s24185879"],"URL":"https:\/\/doi.org\/10.3390\/s24185879","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,9,10]]}}}