{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,17]],"date-time":"2026-06-17T21:32:22Z","timestamp":1781731942148,"version":"3.54.5"},"reference-count":69,"publisher":"MDPI AG","issue":"19","license":[{"start":{"date-parts":[[2024,9,28]],"date-time":"2024-09-28T00:00:00Z","timestamp":1727481600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["11772072"],"award-info":[{"award-number":["11772072"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A circular capacitive rainfall sensor can operate from non-touch mode to touch mode; that is, under the action of enough rainwater, its movable electrode plate can form a circular contact area with its fixed electrode plate. Therefore, the weight of rainwater is borne by only its movable electrode plate in non-touch mode operation but by both its movable and fixed electrode plates in touch mode operation, and the total capacitance of its touch mode operation is much larger than that of its non-touch mode operation. Essential to its numerical design and calibration is the ability to predict the deflection shape of its moveable electrode plate to determine its total capacitance. This requires the analytical solution to the fluid\u2013structure interaction problem of its movable electrode plate under rainwater. In our previous work, only the analytical solution for the fluid\u2013structure interaction problem before its movable electrode plate touches its fixed electrode plate was obtained, and how to numerically design and calibrate a circular non-touch mode capacitive rainfall sensor was illustrated. In this paper, the analytical solution for the fluid\u2013structure interaction problem after its movable electrode plate touches its fixed electrode plate is obtained, and how to numerically design and calibrate a circular touch mode capacitive rainfall sensor is illustrated for the first time. The numerical results show that the total capacitance and rainwater volume when the circular capacitive rainfall sensor operates in touch mode is indeed much larger than that when the same circular capacitive rainfall sensor operates in non-touch mode, and that the average increase in the maximum membrane stress per unit rainwater volume when the circular capacitive rainfall sensor operates in touch mode can be about 20 times smaller than that when the same circular capacitive rainfall sensor operates in non-touch mode. This is where the circular touch mode capacitive rainfall sensor excels.<\/jats:p>","DOI":"10.3390\/s24196291","type":"journal-article","created":{"date-parts":[[2024,9,30]],"date-time":"2024-09-30T07:19:37Z","timestamp":1727680777000},"page":"6291","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["A Circular Touch Mode Capacitive Rainfall Sensor: Analytical Solution and Numerical Design and Calibration"],"prefix":"10.3390","volume":"24","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8880-3961","authenticated-orcid":false,"given":"Xiao-Ting","family":"He","sequence":"first","affiliation":[{"name":"School of Civil Engineering, Chongqing University, Chongqing 400045, China"},{"name":"Key Laboratory of New Technology for Construction of Cities in Mountain Area (Chongqing University), Ministry of Education, Chongqing 400045, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun-Song","family":"Ran","sequence":"additional","affiliation":[{"name":"School of Civil Engineering, Chongqing University, Chongqing 400045, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ji","family":"Wu","sequence":"additional","affiliation":[{"name":"School of Civil Engineering, Chongqing University, Chongqing 400045, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fei-Yan","family":"Li","sequence":"additional","affiliation":[{"name":"School of Civil Engineering, Chongqing University, Chongqing 400045, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4356-7173","authenticated-orcid":false,"given":"Jun-Yi","family":"Sun","sequence":"additional","affiliation":[{"name":"School of Civil Engineering, Chongqing University, Chongqing 400045, China"},{"name":"Key Laboratory of New Technology for Construction of Cities in Mountain Area (Chongqing University), Ministry of Education, Chongqing 400045, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2024,9,28]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1103","DOI":"10.1080\/02678292.2020.1846093","article-title":"Capacitive-type liquid crystal temperature sensor","volume":"48","author":"Jing","year":"2021","journal-title":"Liq. Cryst."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"3539","DOI":"10.1007\/s10854-020-02902-0","article-title":"Performance of interdigitated capacitive-type CO2 sensor based on polypyrrole\/copper phthalocyanine nanocomposite","volume":"31","author":"Riyazi","year":"2020","journal-title":"J. Mater. Sci. Mater. Electron."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1109\/TIM.2020.3040880","article-title":"A linear capacitive sensor for ppm moisture measurement in SF6 gas-insulated switchgear","volume":"70","author":"Zargar","year":"2021","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"2001023","DOI":"10.1002\/admt.202001023","article-title":"Recent progress on flexible capacitive pressure sensors: From design and materials to applications","volume":"6","author":"Mishra","year":"2021","journal-title":"Adv. Mater. Technol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"102023","DOI":"10.1016\/j.mtcomm.2021.102023","article-title":"Highly sensitive and flexible capacitive elastomeric sensors for compressive strain measurements","volume":"26","author":"Qiu","year":"2021","journal-title":"Mater. Today Commun."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"2100358","DOI":"10.1002\/admt.202100358","article-title":"Double Side Electromagnetic Interference-Shielded Bending-Insensitive Capacitive-Type Flexible Touch Sensor with Linear Response over a Wide Detection Range","volume":"6","author":"Yoo","year":"2021","journal-title":"Adv. Mater. Technol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"131620","DOI":"10.1016\/j.snb.2022.131620","article-title":"Printed flexible capacitive humidity sensors for field application","volume":"359","author":"Zhang","year":"2022","journal-title":"Sens. Actuators B Chem."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1441","DOI":"10.1021\/acsami.0c18355","article-title":"Capacitive pressure sensors containing reliefs on solution-processable hydrogel electrodes","volume":"13","author":"Zhou","year":"2021","journal-title":"ACS Appl. Mater. Interfaces"},{"key":"ref_9","first-page":"1","article-title":"Robust analog multisensory array system for lossy capacitive sensors over long distances","volume":"72","author":"Tsirou","year":"2023","journal-title":"IEEE Trans. Instrum. Measurement."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"108383","DOI":"10.1016\/j.sse.2022.108383","article-title":"Sensing performance of Ti\/TiO2 nanosheets\/Au capacitive device: Implication of resonant frequency","volume":"194","author":"Chowdhury","year":"2022","journal-title":"Solid-State Electron."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1016\/j.isatra.2021.01.024","article-title":"A constant phase impedance sensor for measuring conducting liquid level","volume":"115","author":"Rahman","year":"2021","journal-title":"ISA Trans."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"112251","DOI":"10.1016\/j.sna.2020.112251","article-title":"Tunable flexible capacitive pressure sensors using arrangement of polydimethylsiloxane micro-pyramids for bio-signal monitoring","volume":"314","author":"Thouti","year":"2020","journal-title":"Sens. Actuators A Phys."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"115025","DOI":"10.1016\/j.sna.2024.115025","article-title":"Wavy-shaped flexible capacitive strain sensor for multiple deformations recognition","volume":"366","author":"Ma","year":"2024","journal-title":"Sens. Actuators A Physical."},{"key":"ref_14","first-page":"1","article-title":"Flexible interfacial capacitive pressure sensor based on randomly distributed micro-pits electrode","volume":"71","author":"Xie","year":"2022","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1016\/j.carbon.2020.05.042","article-title":"A graphite nanoplatelet-based highly sensitive flexible strain sensor","volume":"166","author":"Xu","year":"2020","journal-title":"Carbon"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"9641","DOI":"10.1109\/JSEN.2019.2926952","article-title":"Investigation of ring touch mode capacitive pressure sensor with an electrothermomechanical coupling contact model","volume":"19","author":"Li","year":"2019","journal-title":"IEEE Sens. J."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"105118","DOI":"10.1016\/j.mejo.2021.105118","article-title":"Capacitance response of concave well substrate touch-mode capacitive pressure sensor: Mathematical analysis and simulation","volume":"114","author":"Kang","year":"2021","journal-title":"Microelectron. J."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1950206","DOI":"10.1142\/S0218126619502062","article-title":"Study of MEMS touch-mode capacitive pressure sensor utilizing flexible sic circular diaphragm: Robust design, theoretical modeling, numerical simulation and performance comparison","volume":"28","author":"Jindal","year":"2019","journal-title":"J. Circuits Syst. Comput."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"502","DOI":"10.1109\/JSEN.2007.891996","article-title":"An analytical solution to circular touch mode capacitor","volume":"7","author":"Daigle","year":"2007","journal-title":"IEEE Sens. J."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"015025","DOI":"10.1088\/2053-1583\/aa8c8a","article-title":"Touch-mode capacitive pressure sensor with graphene-polymer heterostructure membrane","volume":"5","author":"Berger","year":"2018","journal-title":"2D Mater."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Li, X., Sun, J.Y., Shi, B.B., Zhao, Z.H., and He, X.T. (2020). A theoretical study on an elastic polymer thin film-based capacitive wind-pressure sensor. Polymers, 12.","DOI":"10.3390\/polym12092133"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1438","DOI":"10.1080\/00218464.2021.1904911","article-title":"Effect of pressure on pull-off of flat cylindrical punch adhered to circular membrane","volume":"98","author":"Plaut","year":"2022","journal-title":"J. Adhesion."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1016\/j.measurement.2017.07.025","article-title":"A theoretical study of an improved capacitive pressure sensor: Closed-form solution of uniformly loaded annular membranes","volume":"111","author":"Lian","year":"2017","journal-title":"Measurement"},{"key":"ref_24","first-page":"213","article-title":"Circular diaphragm-based MOEMS pressure sensor using ring resonator","volume":"13","author":"Yashaswini","year":"2020","journal-title":"Int. J. Inf. Technol."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Li, F.Y., Zhang, Q., Li, X., He, X.T., and Sun, J.Y. (2022). Polymer conductive membrane-based non-touch mode circular capacitive pressure sensors: An analytical solution-based method for design and numerical calibration. Polymers, 14.","DOI":"10.3390\/polym14153087"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"114285","DOI":"10.1016\/j.sna.2023.114285","article-title":"Multi-functional safety sensor coupling capacitive and inductive measurement for physical human\u2013robot interaction","volume":"354","author":"Yim","year":"2023","journal-title":"Sens. Actuators A Physical"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"5610","DOI":"10.1021\/acs.nanolett.8b02088","article-title":"A highly sensitive capacitive-type strain sensor using wrinkled ultrathin gold films","volume":"18","author":"Nur","year":"2018","journal-title":"Nano Lett."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"2969","DOI":"10.1007\/s10706-020-01672-0","article-title":"Exploring the applicability of low-cost capacitive and resistive water content sensors on compacted soils","volume":"39","author":"Teixeira","year":"2021","journal-title":"Geotech. Geol. Eng."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1080\/00405000.2022.2061761","article-title":"Structure design and application of all-fiber-based capacitive sensor","volume":"114","author":"Chen","year":"2023","journal-title":"J. Text. Inst."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"3735","DOI":"10.1007\/s13762-023-05218-8","article-title":"Soil moisture evaluation with spiral fringing field capacitive sensors","volume":"21","author":"Oommen","year":"2024","journal-title":"Int. J. Environ. Sci. Technol."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"835","DOI":"10.1016\/0924-4247(91)87096-L","article-title":"An integrable capacitive angular displacement sensor with improved linearity","volume":"25\u201327","author":"Wolffenbuttel","year":"1991","journal-title":"Sens. Actuators A Phys."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1356","DOI":"10.1109\/JSEN.2021.3132387","article-title":"Modeling for elastomer displacement analysis of capacitive six-axis force\/torque sensor","volume":"22","author":"Pu","year":"2021","journal-title":"IEEE Sens. J."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"112939","DOI":"10.1016\/j.sna.2021.112939","article-title":"Design of a three-dimensional capacitor-based six-axis force sensor for human-robot interaction","volume":"331","author":"Liu","year":"2021","journal-title":"Sens. Actuators A Phys."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"1662","DOI":"10.1109\/TMECH.2018.2850962","article-title":"Torque sensor embedded actuator module for robotic applications","volume":"23","author":"Kim","year":"2018","journal-title":"IEEE\/ASME Trans. Mechatron."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1080\/03772063.2018.1518732","article-title":"A robust two-axis tilt angle sensor based on air\/liquid two-phase dielectric capacitive sensing structure","volume":"66","author":"Dinh","year":"2020","journal-title":"IETE J. Res."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1089\/soro.2018.0055","article-title":"Capacitive stretch sensing for robotic skins","volume":"6","author":"Tairych","year":"2019","journal-title":"Soft Robot."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.sna.2019.07.007","article-title":"Recent advances in non-contact force sensors used for micro\/nano manipulation","volume":"296","author":"Zang","year":"2019","journal-title":"Sens. Actuators A Phys."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"21391","DOI":"10.1109\/JSEN.2022.3210467","article-title":"Capacitive sensors for multiphase flow measurement: A review","volume":"22","author":"Wu","year":"2022","journal-title":"IEEE Sens. J."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"7716","DOI":"10.1109\/TIM.2020.2982842","article-title":"A nonintrusive magnetically coupled sensor for measuring liquid level","volume":"69","author":"Sandra","year":"2020","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"12441","DOI":"10.1109\/JSEN.2023.3270229","article-title":"Design and application of multidimensional force\/torque sensors in surgical robots: A review","volume":"23","author":"Li","year":"2023","journal-title":"IEEE Sens. J."},{"key":"ref_41","doi-asserted-by":"crossref","unstructured":"Zhang, Q., Li, F.Y., Li, X., He, X.T., and Sun, J.Y. (2022). Polymer conductive membrane-based circular capacitive pressure sensors from non-touch mode of operation to touch mode of operation: An analytical solution-based method for design and numerical calibration. Polymers, 14.","DOI":"10.3390\/polym14183850"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"2100769","DOI":"10.1002\/admt.202100769","article-title":"A super-stretchable and highly sensitive carbon nanotube capacitive strain sensor for wearable applications and soft robotics","volume":"7","author":"Hu","year":"2022","journal-title":"Adv. Mater. Technol."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"27334","DOI":"10.1039\/C9TA10489E","article-title":"A bio-inspired cilia array as the dielectric layer for flexible capacitive pressure sensors with high sensitivity and a broad detection range","volume":"7","author":"Zhou","year":"2019","journal-title":"J. Mater. Chem. A"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"2001187","DOI":"10.1002\/adem.202001187","article-title":"Recent progress in flexible pressure sensors based electronic skin","volume":"23","author":"Zhao","year":"2021","journal-title":"Adv. Eng. Mater."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.snb.2018.12.095","article-title":"A fabrication process of flexible IDE capacitive chemical sensors using a two step lift-off method based on PVA patterning","volume":"284","author":"Filippidou","year":"2019","journal-title":"Sens. Actuators B Chem."},{"key":"ref_46","first-page":"263","article-title":"Capacitive pressure sensor with center clamped diaphragm","volume":"E80C","author":"Omi","year":"1997","journal-title":"IEICE Trans. Electron."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1016\/S0924-4247(99)00069-2","article-title":"Touch mode capacitive pressure sensors","volume":"75","author":"Ko","year":"1999","journal-title":"Sens. Actuators A Phys."},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"Mei, D., Sun, J.-Y., Zhao, Z.-H., and He, X.-T. (2020). A closed-form solution for the boundary value problem of gas pressurized circular membranes in contact with frictionless rigid plates. Mathematics, 8.","DOI":"10.3390\/math8061017"},{"key":"ref_49","doi-asserted-by":"crossref","unstructured":"Li, F.Y., Li, X., Zhang, Q., He, X.T., and Sun, J.Y. (2022). A refined closed-form solution for laterally loaded circular membranes in frictionless contact with rigid flat plates: Simultaneous improvement of out-of-plane equilibrium equation and geometric equation. Mathematics, 10.","DOI":"10.3390\/math10163025"},{"key":"ref_50","doi-asserted-by":"crossref","unstructured":"He, X.-T., Wang, X., Li, F.-Y., and Sun, J.-Y. (2024). An improved theory for designing and numerically calibrating circular touch mode capacitive pressure sensors. Sensors, 24.","DOI":"10.3390\/s24030907"},{"key":"ref_51","doi-asserted-by":"crossref","unstructured":"Sun, J.-Y., Zhang, Q., Wu, J., Li, X., and He, X.-T. (2021). Large Deflection Analysis of Peripherally Fixed Circular Membranes Subjected to Liquid Weight Loading: A Refined Design Theory of Membrane Deflection-Based Rain Gauges. Materials, 14.","DOI":"10.3390\/ma14205992"},{"key":"ref_52","doi-asserted-by":"crossref","unstructured":"Sun, J.-Y., Li, N., and He, X.-T. (2023). An improved mathematical theory for designing membrane deflection-based rain gauges. Mathematics, 11.","DOI":"10.3390\/math11163438"},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.atmosres.2013.04.006","article-title":"Performance of a weighing rain gauge under laboratory simulated time-varying reference rainfall rates","volume":"131","author":"Colli","year":"2013","journal-title":"Atmos. Res."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1016\/j.atmosres.2013.08.007","article-title":"Measurement accuracy of weighing and tipping-bucket rainfall intensity gauges under dynamic laboratory testing","volume":"144","author":"Colli","year":"2014","journal-title":"Atmos. Res."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"1513","DOI":"10.1175\/1520-0426(1997)014<1513:ANMFAD>2.0.CO;2","article-title":"A new method for automated dynamic calibration of tipping-bucket rain gauges","volume":"14","author":"Humphrey","year":"1997","journal-title":"J. Atmos. Ocean. Technol."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1061\/(ASCE)1084-0699(2001)6:2(159)","article-title":"Sampling errors of tipping-bucket rain gauge measurements","volume":"6","author":"Habib","year":"2001","journal-title":"J. Hydrol. Eng."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.atmosres.2004.12.013","article-title":"Improving the accuracy of tipping-bucket rain records using disaggregation techniques","volume":"77","author":"Molini","year":"2005","journal-title":"Atmos. Res."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1016\/j.atmosres.2004.12.012","article-title":"Calibration of tipping bucket rain gauges in the Graz urban research area","volume":"77","year":"2005","journal-title":"Atmos. Res."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1061\/(ASCE)1084-0699(2008)13:6(488)","article-title":"Effect of local errors of tipping-bucket rain gauges on rainfall-runoff simulations","volume":"13","author":"Habib","year":"2008","journal-title":"J. Hydrol. Eng."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"105834","DOI":"10.1016\/j.catena.2021.105834","article-title":"Calibration and error investigation of large tipping bucket flow meters","volume":"209","author":"Schwamback","year":"2022","journal-title":"Catena"},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"125782","DOI":"10.1016\/j.jhydrol.2020.125782","article-title":"A novel method and system for the fast calibration of tipping bucket rain gauges","volume":"597","author":"Liao","year":"2021","journal-title":"J. Hydrol."},{"key":"ref_62","doi-asserted-by":"crossref","unstructured":"Segovia-Cardozo, D.A., Rodriguez-Sinobas, L., Diez-Herrero, A., Zubelzu, S., and Canales-Ide, F. (2021). Understanding the Mechanical Biases of Tipping-Bucket Rain Gauges: A Semi-Analytical Calibration Approach. Water, 13.","DOI":"10.3390\/w13162285"},{"key":"ref_63","first-page":"731","article-title":"Calibration of tipping bucket hyetographs","volume":"26","author":"Bergmann","year":"2001","journal-title":"Phys. Chem. Earth (C)"},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/0169-8095(95)00066-6","article-title":"Adjustment of tipping-bucket precipitation gauge measurements","volume":"42","author":"Sevruk","year":"1996","journal-title":"Atmos. Res."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"121","DOI":"10.2166\/wst.1998.0450","article-title":"Influence of systematic errors from tipping bucket rain gauges on recorded rainfall data","volume":"37","author":"Fankhauser","year":"1998","journal-title":"Water Sci. Technol."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1016\/j.atmosres.2016.04.016","article-title":"Assessment of measurement errors and dynamic calibration methods for three different tipping bucket rain gauges","volume":"178","author":"Shedekar","year":"2016","journal-title":"Atmos. Res."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1016\/j.agrformet.2019.02.044","article-title":"Dynamic real-time volumetric correction for tipping-bucket rain gauges","volume":"271","author":"Sypka","year":"2019","journal-title":"Agric. For. Meteorol."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1016\/j.atmosres.2016.01.016","article-title":"Comparison of simple rain gauge measurements with precision lysimeter data","volume":"174","author":"Hoffmann","year":"2016","journal-title":"Atmos. Res."},{"key":"ref_69","doi-asserted-by":"crossref","unstructured":"Li, X., Sun, J.-Y., Lu, X.-C., Yang, Z.-X., and He, X.-T. (2021). Steady fluid\u2013structure coupling interface of circular membrane under liquid weight loading: Closed-form solution for differential-integral equations. Mathematics, 9.","DOI":"10.3390\/math9101105"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/19\/6291\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T16:06:07Z","timestamp":1760112367000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/19\/6291"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,28]]},"references-count":69,"journal-issue":{"issue":"19","published-online":{"date-parts":[[2024,10]]}},"alternative-id":["s24196291"],"URL":"https:\/\/doi.org\/10.3390\/s24196291","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,9,28]]}}}