{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,20]],"date-time":"2026-04-20T19:08:37Z","timestamp":1776712117103,"version":"3.51.2"},"reference-count":23,"publisher":"MDPI AG","issue":"19","license":[{"start":{"date-parts":[[2024,9,30]],"date-time":"2024-09-30T00:00:00Z","timestamp":1727654400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>As part of an investigation to detect asymmetries in gait patterns in persons with shoulder injuries, the goal of the present study was to design and validate a Kinect-based motion capture system that would enable the extraction of joint kinematics curves during gait and to compare them with the data obtained through a commercial motion capture system. The study included eight male and two female participants, all diagnosed with anterolateral shoulder pain syndrome in their right upper extremity with a minimum 18 months of disorder evolution. The participants had an average age of 31.8 \u00b1 9.8 years, a height of 173 \u00b1 18 cm, and a weight of 81 \u00b1 15 kg. The gait kinematics were sampled simultaneously with the new system and the Clinical 3DMA system. Shoulder, elbow, hip, and knee kinematics were compared between systems for the pathological and non-pathological sides using repeated measures ANOVA and 1D statistical parametric mapping. For most variables, no significant difference was found between systems. Evidence of a significant difference between the newly developed system and the commercial system was found for knee flexion\u2013extension (p &lt; 0.004, between 60 and 80% of the gait cycle), and for shoulder abduction\u2013adduction. The good concurrent validity of the new Kinect-based motion analysis system found in this study opens promising perspectives for clinical motion tracking using an affordable and simple system.<\/jats:p>","DOI":"10.3390\/s24196351","type":"journal-article","created":{"date-parts":[[2024,9,30]],"date-time":"2024-09-30T11:32:05Z","timestamp":1727695925000},"page":"6351","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Kinect-Based Gait Analysis System Design and Concurrent Validity in Persons with Anterolateral Shoulder Pain Syndrome, Results from a Pilot Study"],"prefix":"10.3390","volume":"24","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3855-2877","authenticated-orcid":false,"given":"Fredy","family":"Bernal","sequence":"first","affiliation":[{"name":"Faculty of Engineering, Universidad Militar Nueva Granada, Bogot\u00e1 110111, Colombia"},{"name":"Department of Functional Anatomy, University Libre de Bruxelles, 1170 Brussels, Belgium"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0146-3731","authenticated-orcid":false,"given":"Veronique","family":"Feipel","sequence":"additional","affiliation":[{"name":"Department of Functional Anatomy, University Libre de Bruxelles, 1170 Brussels, Belgium"}]},{"given":"Mauricio","family":"Plaza","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, Universidad Militar Nueva Granada, Bogot\u00e1 110231, Colombia"}]}],"member":"1968","published-online":{"date-parts":[[2024,9,30]]},"reference":[{"key":"ref_1","unstructured":"Jacqueline, P. (1992). Gait Analysis Normal and Pathological Function, SLACK Incorporated."},{"key":"ref_2","unstructured":"Bonnefoy-Mazure, A., and Armand, S. (2015). Normal Gait. Orthopedic Management of Children with Cerebral Palsy, Nova Science Publishers Inc."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"102835","DOI":"10.1016\/j.humov.2021.102835","article-title":"The effects of forearm movements on human gait during walking with various self-selected speeds","volume":"79","author":"Bloom","year":"2021","journal-title":"Hum. Mov. Sci."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1016\/j.irbm.2019.11.001","article-title":"Human Gait Recognition Using Hip, Knee and Ankle Joint Ratios","volume":"41","author":"Akhil","year":"2020","journal-title":"IRBM"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1016\/j.jbiomech.2017.09.011","article-title":"Effect of arm swinging on lumbar spine and hip joint forces","volume":"70","author":"Angelini","year":"2017","journal-title":"J. Biomech."},{"key":"ref_6","first-page":"48","article-title":"Comportamiento de la enfermedad laboral en Colombia 2015\u20132017","volume":"175","year":"2019","journal-title":"Rev. Fasecolda"},{"key":"ref_7","unstructured":"Rojas, V.L.S. (2019). Prevalencia del S\u00edndrome de Manguito Rotador en Pacientes Valorados en una Ips de, Bogot\u00e1. [Posgraduated. Thesis, Universidad del Rosario]."},{"key":"ref_8","unstructured":"Dane, D.N.d.E. (2023, November 10). Poblaci\u00f3n con Registro Para la Localizaci\u00f3n y Caracterizaci\u00f3n de las Personas con Discapacidad. Bogot\u00e1, Available online: https:\/\/www.minsalud.gov.co\/proteccionsocial\/promocion-social\/Discapacidad\/Paginas\/registro-localizacion.aspx."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/j.gaitpost.2004.04.004","article-title":"Human movement analusus using stereophotagrammetry. Part 2: Instrumental errors","volume":"21","author":"Chiari","year":"2005","journal-title":"Gait Posture"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/j.gaitpost.2023.05.026","article-title":"Characteristic 3D foot motion patterns during gait of patients with Charcot-Marie-Tooth identified by cluster analysis","volume":"104","author":"Schmidt","year":"2023","journal-title":"Gait Posture"},{"key":"ref_11","unstructured":"STT System (2023, December 15). Clinical 3DMA. Available online: https:\/\/www.stt-systems.com\/es\/analisis-de-movimiento\/captura-de-movimiento-optico-3d\/3dma-clinico\/."},{"key":"ref_12","unstructured":"Microsoft\u00a9 (2023, June 29). Azure Kinect DK Depth Camera. Available online: https:\/\/learn.microsoft.com\/en-us\/azure\/kinect-dk\/depth-camera."},{"key":"ref_13","first-page":"353","article-title":"Posture and movement: Coordination and control","volume":"135","author":"Lacquaniti","year":"1997","journal-title":"Arch. Ital. De Biol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"e2652","DOI":"10.7717\/peerj.2652","article-title":"Region-of-interest analyses of one-dimensional biomechanical trajectories: Bridging 0D and 1D theory, augmenting statical power","volume":"4","author":"Pataky","year":"2016","journal-title":"PeerJ"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1277","DOI":"10.1016\/j.jbiomech.2015.02.051","article-title":"Zero- vs. one-dimensional, parametric vs. non-parametric, and confidence interval vs. hypothesis testing procedures in one-dimensional biomechanical trajectory analysis","volume":"48","author":"Pataky","year":"2015","journal-title":"J. Biomech."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1976","DOI":"10.1016\/j.jbiomech.2010.03.008","article-title":"Generalized n-dimensional biomechanical field analysis using","volume":"43","author":"Pataky","year":"2010","journal-title":"J. Biomech."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Acal, C., and Aguilera, A. (2022). Basis expansion approaches for functional analysis of variance with repeated measures. Adv. Data Anal. Classif., 1\u201331.","DOI":"10.1007\/s11634-022-00500-y"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"699","DOI":"10.1080\/17461391.2017.1308560","article-title":"Side-to-side differences in lower extremity biomechanics during multi-directional jump landing in volleyball athletes","volume":"17","author":"Sinsurin","year":"2017","journal-title":"Eur. J. Sport Sci."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1016\/j.gaitpost.2012.02.004","article-title":"Longitudinal changes in knee joint biomechanics during level walking following anterior cruciate ligament reconstruction surgery","volume":"36","author":"Webster","year":"2012","journal-title":"Gait Posture"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"111442","DOI":"10.1016\/j.measurement.2022.111442","article-title":"Validity and repeatability of a new inertial measurement unit system for gait analysis on kinematic parameters: Comparison with an optoelectronic system","volume":"198","author":"Piche","year":"2022","journal-title":"Meas. J. Int. Meas. Confed."},{"key":"ref_21","unstructured":"Chakraborty, S., Mondal, D., and Nandy, A. (2018, January 15\u201318). Measurement: Journal of the International Measurement Confederation. Proceedings of the INDICON 2018\u201415th IEEE India Council International Conference, Coimbatore, India."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/j.medengphy.2019.10.017","article-title":"Reliability and validity analyzes of Kinect V2 based measurement system for shoulder motions","volume":"76","author":"Zileli","year":"2020","journal-title":"Med. Eng. Phys."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"784865","DOI":"10.3389\/fphys.2021.784865","article-title":"Development of a Robust, Simple, and Affordable Human Gait Analysis System Using Bottom-Up Pose Estimation with a Smartphone Camera","volume":"12","author":"Viswakumar","year":"2022","journal-title":"Front. Physiol."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/19\/6351\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T16:07:59Z","timestamp":1760112479000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/24\/19\/6351"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,30]]},"references-count":23,"journal-issue":{"issue":"19","published-online":{"date-parts":[[2024,10]]}},"alternative-id":["s24196351"],"URL":"https:\/\/doi.org\/10.3390\/s24196351","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,9,30]]}}}