{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,4]],"date-time":"2026-10-04T09:00:51Z","timestamp":1791104451253,"version":"4.1.0"},"reference-count":44,"publisher":"MDPI AG","issue":"1","license":[{"start":{"date-parts":[[2009,1,8]],"date-time":"2009-01-08T00:00:00Z","timestamp":1231372800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>This paper describes a procedure for the determination of antimony (III) by differential pulse anodic stripping voltammetry using a mercury film screen-printed electrode as the working electrode. The procedure has been optimized using experimental design methodology. Under these conditions, in terms of Residual Standard Deviation (RSD), the repeatability (3.81 %) and the reproducibility (5.07 %) of the constructed electrodes were both analyzed. The detection limit for Sb (III) was calculated at a value of 1.27\u00d710\u20138 M. The linear range obtained was between 0.99 \u00d7 10\u20138 \u2013 8.26 \u00d7 10\u20138 M. An analysis of possible effects due to the presence of foreign ions in the solution was performed and the procedure was successfully applied to the determination of antimony levels in pharmaceutical preparations and sea water samples.<\/jats:p>","DOI":"10.3390\/s90100219","type":"journal-article","created":{"date-parts":[[2009,1,8]],"date-time":"2009-01-08T06:00:18Z","timestamp":1231394418000},"page":"219-231","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":37,"title":["Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode"],"prefix":"10.3390","volume":"9","author":[{"given":"Olga","family":"Dom\u00ednguez-Renedo","sequence":"first","affiliation":[{"name":"Departamento de Qu\u00edmica, \u00c1rea de Qu\u00edmica Anal\u00edtica, Facultad de Ciencias, Universidad de Burgos, Plaza Misael Ba\u00f1uelos s\/n, E-09001 Burgos, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Jes\u00fas G\u00f3mez Gonz\u00e1lez","sequence":"additional","affiliation":[{"name":"Departamento de Qu\u00edmica, \u00c1rea de Qu\u00edmica Anal\u00edtica, Facultad de Ciencias, Universidad de Burgos, Plaza Misael Ba\u00f1uelos s\/n, E-09001 Burgos, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4932-6445","authenticated-orcid":false,"given":"M.","family":"Julia Arcos-Mart\u00ednez","sequence":"additional","affiliation":[{"name":"Departamento de Qu\u00edmica, \u00c1rea de Qu\u00edmica Anal\u00edtica, Facultad de Ciencias, Universidad de Burgos, Plaza Misael Ba\u00f1uelos s\/n, E-09001 Burgos, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2009,1,8]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"1155","DOI":"10.1039\/b513988k","article-title":"Concentrations, enrichment and predominant sources of Sb and other trace elements in size classified airborne particulate matter collected in Tokyo from 1995 to 2004","volume":"7","author":"Furuta","year":"2005","journal-title":"J. Environ. Monit."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1007\/s006040050010","article-title":"Characterisation of screen-printed electrodes for detection of heavy metals","volume":"131","author":"Palchetti","year":"1999","journal-title":"Microchim. Acta"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/S0003-2670(01)01474-X","article-title":"Determination of inorganic antimony species in seawater by differential pulse anodic stripping voltammetry: stability of the trivalent state","volume":"452","author":"Quentel","year":"2002","journal-title":"Anal. Chim. Acta"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/S0165-9936(00)00065-0","article-title":"Speciation of antimony for the 21st century: promises and pitfalls","volume":"20","author":"Krachler","year":"2001","journal-title":"Trac-Trend Anal. Chem."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1016\/0039-9140(82)80068-4","article-title":"Studies of pretreatments in the determination of Zn, Cd, Pb, Cu, Sb and Bi in suspended particulate matter and plankton by differential-pulse anodic-stripping voltammetry with a hanging mercury drop electrode","volume":"29","author":"Gillain","year":"1982","journal-title":"Talanta"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1021\/ac00279a006","article-title":"Preconcentration of selenium and antimony from seawater for determination by graphite-furnace atomic-absorption spectrometry","volume":"57","author":"Sturgeon","year":"1985","journal-title":"Anal. Chem."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/0022-0728(87)85213-0","article-title":"Determination of antimony in seawater by cathodic stripping voltammetry","volume":"235","author":"Capodaglio","year":"1987","journal-title":"J. Electroanal. Chem."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1039\/b517844b","article-title":"Contamination of Canadian and European bottled waters with antimony from PET containers","volume":"8","author":"Shotyk","year":"2006","journal-title":"J. Environ. Monit."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1927","DOI":"10.1016\/0039-9140(93)80117-A","article-title":"Online microwave sample pretreatment for the determination of mercury in blood by flow-injection cold vapor atomic-absorption spectrometry","volume":"40","author":"Guo","year":"1993","journal-title":"Talanta"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"770","DOI":"10.1007\/s00216-003-2351-x","article-title":"Stripping chronopotentiometric measurements of lead(II) and cadmium(II) in soils extracts and wastewaters using a bismuth film screen-printed electrode assembly","volume":"378","author":"Kadara","year":"2004","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1007\/s002160050770","article-title":"Analytical methods for antimony speciation in waters at trace and ultratrace levels. A review","volume":"360","author":"Smichowski","year":"1998","journal-title":"Fresenius J. Anal. Chem."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1007\/s002169600002","article-title":"Trace analysis of antimony (III) and antimony (V) by adsorptive stripping voltammetry","volume":"354","author":"Wagner","year":"1996","journal-title":"Fresenius J. Anal. Chem."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0003-2670(98)00323-7","article-title":"Combined use of differential pulse adsorptive and anodic stripping techniques for the determination of antimony(III) and antimony(V) in zinc electrolyte","volume":"372","author":"Bond","year":"1998","journal-title":"Anal. Chim. Acta"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/0022-0728(93)87040-3","article-title":"Screen-Printed Ultramicroelectrode Arrays for on-Site Stripping Measurements of Trace-Metals","volume":"361","author":"Wang","year":"1993","journal-title":"J. Electroanal. Chem."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1016\/S0039-9140(99)00267-2","article-title":"Hand-held lead analyzer","volume":"51","author":"Yarnitzky","year":"2000","journal-title":"Talanta"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1017","DOI":"10.1002\/(SICI)1521-4109(199810)10:15<1017::AID-ELAN1017>3.0.CO;2-D","article-title":"Determination of trace mercury in saltwaters at screen-printed electrodes modified with sumichelate Q10R","volume":"10","author":"Ugo","year":"1998","journal-title":"Electroanal"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1016\/S0925-4005(98)00078-1","article-title":"An environmental monitoring system for trace metals using stripping voltammetry","volume":"48","author":"Desmond","year":"1998","journal-title":"Sensor Actuator B-Chem."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1002\/1521-4109(200101)13:1<34::AID-ELAN34>3.0.CO;2-5","article-title":"Anodic stripping voltammetry with a heated mercury film on a screen-printed carbon electrode","volume":"13","author":"Jasinski","year":"2001","journal-title":"Electroanal."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1016\/S0165-9936(03)00703-9","article-title":"Screen-printed electrochemical sensors for monitoring metal pollutants","volume":"22","author":"Honeychurch","year":"2003","journal-title":"Trac-Trends Anal. Chem."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1016\/j.aca.2005.07.058","article-title":"Development of a portable electroanalytical system for the stripping voltammetry of metals: Determination of copper in acetic acid soil extracts","volume":"552","author":"Beni","year":"2005","journal-title":"Anal. Chim. Acta"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/j.aca.2004.08.065","article-title":"Miniaturised stripping-based carbon modified sensor for in field analysis of heavy metals","volume":"530","author":"Palchetti","year":"2005","journal-title":"Anal. Chim. Acta"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1007\/s00216-004-2704-0","article-title":"Urease-glutamic dehydrogenase biosensor for screening heavy metals in water and soil samples","volume":"380","author":"Rodriguez","year":"2004","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1016\/S0039-9140(02)00060-7","article-title":"Voltammetric behaviour and trace determination of copper at a mercury-free screen-printed carbon electrode","volume":"57","author":"Honeychurch","year":"2002","journal-title":"Talanta"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1089","DOI":"10.1016\/j.talanta.2005.01.020","article-title":"Resolving the copper interference effect on the stripping chronopotentiometric response of lead(II) obtained at bismuth film screen-printed electrode","volume":"66","author":"Kadara","year":"2005","journal-title":"Talanta"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1080\/0306731021000049617","article-title":"Polymer-mercury coated screen-printed sensors for electrochemical stripping analysis of heavy metals","volume":"83","author":"Palchetti","year":"2003","journal-title":"Int. J. Environ. Anal. Chem."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1016\/S0003-2670(02)00472-5","article-title":"Voltammetric behavior and trace determination of Pb2+ at a mercury-free screen-printed silver electrode","volume":"464","author":"Zen","year":"2002","journal-title":"Anal. Chim. Acta"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1016\/S0003-2670(01)01219-3","article-title":"Screen-printed anodic stripping voltammetric sensor containing HgO for heavy metal analysis","volume":"443","author":"Choi","year":"2001","journal-title":"Anal. Chim. Acta"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"3683","DOI":"10.1016\/j.biomaterials.2004.09.024","article-title":"An amperometric urea biosensor based on covalent immobilization of urease onto an electrochemically prepared copolymer poly (N-3-aminopropyl pyrrole-co-pyrrole) film","volume":"26","author":"Rajesh","year":"2005","journal-title":"Biomaterials"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1016\/0003-2670(94)00452-R","article-title":"Anodic-stripping potentiometric determination of antimony in environmental materials","volume":"302","author":"Adeloju","year":"1995","journal-title":"Anal. Chim. Acta"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1871","DOI":"10.1039\/a803408g","article-title":"Anodic stripping potentiometric determination of antimony on a combined electrode","volume":"123","author":"Adeloju","year":"1998","journal-title":"Analyst"},{"key":"ref_31","unstructured":"Statgraphics Centurion, StatPoint Inc."},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Rousseeuw, P.J., and Leroy, A. M. (1987). Robust Regression and Outlier Detection, Wiley & Sons, Inc.","DOI":"10.1002\/0471725382"},{"key":"ref_33","unstructured":"Massart, D.L., Vandeginste, B.G.M., Buydens, L.M.C., de Jong, S., Lewi, P.J., Smeyers-Verbeke, J., and Mann, C.K. (1998). Handbook of Chemometrics and Qualimetrics, Part A, Elsevier."},{"key":"ref_34","unstructured":"(2000). Capability of Detection. Part 2: Methodology in the Linear Calibration Case (11843-2), International Organization for Standardization, ISO."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"2095","DOI":"10.1016\/S0584-8547(02)00178-7","article-title":"Determination of total arsenic by batch hydride generation atomic absorption spectrometry in injectable drugs containing high levels of Sb(V) as N-methylglucamine antimonate","volume":"57","author":"Flores","year":"2002","journal-title":"Spectrochim. Acta B"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1016\/S0022-0728(74)80469-9","article-title":"Evaluation and comparison of some techniques of anodic-stripping voltammetry","volume":"55","author":"Batley","year":"1974","journal-title":"J. Electroanal. Chem."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"793","DOI":"10.1002\/elan.1140030812","article-title":"Trace determination of antimony and bismuth in snow and water samples by stripping voltammetry","volume":"3","author":"Postupolski","year":"1991","journal-title":"Electroanal."},{"key":"ref_38","first-page":"471","article-title":"Determination of Zn, Cd, Pb, Cu, Sb and bi in milk by differential pulse anodic-stripping voltammetry with a hanging mercury drop electrode following 2 independent mineralization methods","volume":"13","author":"Gillain","year":"1985","journal-title":"Analusis"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"1355","DOI":"10.1039\/an9851001355","article-title":"Applicability of anodic-stripping voltammetry and graphite-furnace atomic-absorption spectrometry to the determination of antimony in biological matrices - A comparative-study","volume":"110","author":"Costantini","year":"1985","journal-title":"Analyst"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1021\/ac00129a004","article-title":"Simultaneous extraction of trivalent and pentavalent antimony and arsenic species in natural-waters for neutron-activation analysis","volume":"59","author":"Mok","year":"1987","journal-title":"Anal. Chem."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"1417","DOI":"10.1039\/AN9931801417","article-title":"L-cysteine as a reducing and releasing agent for the determination of antimony and arsenic using flow-injection hydride generation atomic-absorption spectrometry. 1. Optimization of the analytical parameters","volume":"118","author":"Welz","year":"1993","journal-title":"Analyst"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"1425","DOI":"10.1039\/AN9931801425","article-title":"L-cysteine as a reducing and releasing agent for the determination of antimony and arsenic using flow-injection hydride generation atomic-absorption spectrometry .2. Interference studies and the analysis of copper and steel","volume":"118","author":"Welz","year":"1993","journal-title":"Analyst"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/j.aca.2007.02.069","article-title":"Anodic stripping voltammetry of antimony using gold nanoparticle-modified carbon screen-printed electrodes","volume":"589","year":"2007","journal-title":"Anal. Chim. Acta"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"820","DOI":"10.1016\/j.elecom.2006.11.016","article-title":"A novel method for the anodic stripping voltammetry determination of Sb(III) using silver nanoparticle-modified screen-printed electrodes","volume":"9","year":"2007","journal-title":"Electrochem. Commun."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/9\/1\/219\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T22:09:39Z","timestamp":1760220579000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/9\/1\/219"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,1,8]]},"references-count":44,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2009,1]]}},"alternative-id":["s90100219"],"URL":"https:\/\/doi.org\/10.3390\/s90100219","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,1,8]]}}}