{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T00:17:19Z","timestamp":1789690639840,"version":"4.0.1"},"reference-count":16,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2009,2,2]],"date-time":"2009-02-02T00:00:00Z","timestamp":1233532800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The representative measurement of gas concentration and fluxes in heterogeneous soils is one of the current challenges when analyzing the interactions of biogeochemical processes in soils and global change. Furthermore, recent research projects on CO2-sequestration have an urgent need of CO2-monitoring networks. Therefore, a measurement method based on selective permeation of gases through tubular membranes has been developed. Combining the specific permeation rates of gas components for a membrane and Dalton\u2019s principle, the gas concentration (or partial pressure) can be determined by the measurement of physical quantities (pressure or volume) only. Due to the comparatively small permeation constants of membranes, the influence of the sensor on its surrounding area can be neglected. The design of the sensor membranes can be adapted to the spatial scale from the bench scale to the field scale. The sensitive area for the measurement can be optimized to obtain representative results. Furthermore, a continuous time-averaged measurement is possible where the time for averaging is simply controlled by the wall-thickness of the membrane used. The measuring method is demonstrated for continuous monitoring of O2 and CO2 inside of a sand filled Lysimeter. Using three sensor planes inside the sand pack, which were installed normal to the gas flow direction and a reference measurement system, we demonstrate the accuracy of the gas-detection for different flux-based boundary conditions.<\/jats:p>","DOI":"10.3390\/s90200756","type":"journal-article","created":{"date-parts":[[2009,2,2]],"date-time":"2009-02-02T14:24:15Z","timestamp":1233584655000},"page":"756-767","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":25,"title":["Membrane Based Measurement Technology for in situ Monitoring of Gases in Soil"],"prefix":"10.3390","volume":"9","author":[{"given":"Detlef","family":"Lazik","sequence":"first","affiliation":[{"name":"UFZ - Helmholtz-Centre for Environmental Research, T.-Lieser-Strasse 4, 06120 Halle, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastian","family":"Ebert","sequence":"additional","affiliation":[{"name":"UFZ - Helmholtz-Centre for Environmental Research, T.-Lieser-Strasse 4, 06120 Halle, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Leuthold","sequence":"additional","affiliation":[{"name":"UFZ - Helmholtz-Centre for Environmental Research, T.-Lieser-Strasse 4, 06120 Halle, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jens","family":"Hagenau","sequence":"additional","affiliation":[{"name":"UFZ - Helmholtz-Centre for Environmental Research, T.-Lieser-Strasse 4, 06120 Halle, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Helmut","family":"Geistlinger","sequence":"additional","affiliation":[{"name":"UFZ - Helmholtz-Centre for Environmental Research, T.-Lieser-Strasse 4, 06120 Halle, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2009,2,2]]},"reference":[{"key":"ref_1","unstructured":"Barber, C. Real-time and in situ Investigation and Monitoring of Organic Contaminants for Assessment of Impact of Remediation. Perth, Australia."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"4","DOI":"10.3390\/s5010004","article-title":"Overview of Sensors and Needs for Environmental Monitoring","volume":"5","author":"Ho","year":"2005","journal-title":"Sensors"},{"key":"ref_3","unstructured":"Johnston, P., and Santillo, D. Carbon Capture and Sequestration: Potential Environmental Impacts. Regina, Canada."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Gerard, D., and Wilson, E.J. (2009). Environmental Bonds and the Challenge of Long-term Carbon Sequestration. J. Environ. Manage., in press.","DOI":"10.1016\/j.jenvman.2008.04.005"},{"key":"ref_5","unstructured":"Caldeira, K. Monitoring of ocean storage projects. Regina, Canada."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1461","DOI":"10.1016\/j.marpolbul.2008.04.048","article-title":"Regional Scale Impacts of Distinct CO2 Additions in the Northern Sea","volume":"56","author":"Blackford","year":"2008","journal-title":"Mar. Pollut. Bull."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1683","DOI":"10.3390\/s7091683","article-title":"The Relative Performance of NDIR-based Sensors in the Near Real-time Analysis of CO2 in Air","volume":"7","author":"Pandey","year":"2007","journal-title":"Sensors"},{"key":"ref_8","unstructured":"Lewicki, J.L., and Oldenburg, C.M. Near-Surface CO2 Monitoring and Analysis to Detect Hidden Geothermal Systems. Stanford, California."},{"key":"ref_9","unstructured":"Weiss, R.F. (1975). Permeable Membrane Gas Saturometer. (US Patent No. 3 871 228)."},{"key":"ref_10","unstructured":"Jax, P., and Leuker, W. (1991). Einrichtung und Verfahren zur Entnahme und Messung von Proben von einer Anzahl verschiedener Messstellen. (DE Patent 41 25 739 A1)."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1016\/0021-9673(94)00944-9","article-title":"Continuous Monitoring of Volatile Organic Compounds in Water Using on-Line Membrane Extraction and Microtrap Gas Chromatography System","volume":"688","author":"Xu","year":"1994","journal-title":"J. Chromatogr. A"},{"key":"ref_12","unstructured":"Davies, G.B., Patterson, B.M., Barber, C., and Johnston, C.D. Evaluating in situ Bioremediation Using Innovative Monitoring Technologies. Taiwan."},{"key":"ref_13","unstructured":"Kaneblei, I., and Rabenecker, H. (2008). Messanordnung zur Konzentrationsbestimmung von Gasen aus fl\u00fcssigen Medien. (DE Patent 19 705 195 A1)."},{"key":"ref_14","unstructured":"Lazik, D., and Geistlinger, H. (1999). Verfahren zur Messung der Konzentration oder des Partialdruckes von Gasen, insbesondere Sauerstoff, in Fluiden und Gassensor. (DE Patent 19 925 482)."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1016\/j.sna.2004.06.015","article-title":"A New Method for Membrane-Based Gas Measurement","volume":"117","author":"Lazik","year":"2005","journal-title":"Sens. Actuat. A"},{"key":"ref_16","unstructured":"Brandrup, J., Immergut, E.H., and Grulke, E.A. (1999). Polymer Handbook, Wiley & Sons. Chapter VI."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/9\/2\/756\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T22:09:46Z","timestamp":1760220586000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/9\/2\/756"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,2,2]]},"references-count":16,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2009,2]]}},"alternative-id":["s90200756"],"URL":"https:\/\/doi.org\/10.3390\/s90200756","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,2,2]]}}}