{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,17]],"date-time":"2026-05-17T06:19:10Z","timestamp":1778998750799,"version":"3.51.4"},"reference-count":21,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2009,2,26]],"date-time":"2009-02-26T00:00:00Z","timestamp":1235606400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>In this report, alkanethiol self assembled monolayers (SAM) with two different chain lengths were used to immobilize the functionalizing enzyme (glucose oxidase) onto gold nanopillar modified electrodes and the electrochemical processes of these functionalized electrodes in glucose detection were investigated. First, the formation of these SAMs on the nanopillar modified electrodes was characterized by the cyclic voltammetry and electrochemical impedance spectroscopy techniques, and then the detection sensitivity of these functionalized electrodes to glucose was evaluated by the amperometry technique. Results showed that the SAM of alkanethiols with a longer chain length resulted in a higher degree of surface coverage with less defect and a higher electron transfer resistance, whereas the SAM of alkanethiols with a shorter chain length gave rise to a higher detection sensitivity to glucose. This study sheds some new insight into how to enhance the sensing performance of nanopillar modified electrodes.<\/jats:p>","DOI":"10.3390\/s90301295","type":"journal-article","created":{"date-parts":[[2009,3,1]],"date-time":"2009-03-01T04:04:25Z","timestamp":1235880265000},"page":"1295-1305","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":38,"title":["Role of SAM Chain Length in Enhancing the Sensitivity of Nanopillar Modified Electrodes for Glucose Detection"],"prefix":"10.3390","volume":"9","author":[{"given":"Venkataramani","family":"Anandan","sequence":"first","affiliation":[{"name":"Micro\/Nano Bioengineering Lab, The University of Georgia, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rajan","family":"Gangadharan","sequence":"additional","affiliation":[{"name":"Micro\/Nano Bioengineering Lab, The University of Georgia, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guigen","family":"Zhang","sequence":"additional","affiliation":[{"name":"Micro\/Nano Bioengineering Lab, The University of Georgia, USA"},{"name":"Faculty of Engineering, The University of Georgia, USA"},{"name":"Bioengineering, Electrical & Computer Engineering, Clemson University, USA"},{"name":"Institute for Biological Interfaces of Engineering, Clemson University, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2009,2,26]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/S0003-2670(97)90075-1","article-title":"Design and development of a miniaturised total chemical analysis system for on-line lactate and glucose monitoring in biological samples","volume":"346","author":"Dempsey","year":"1997","journal-title":"Anal. Chim. Acta"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1016\/j.aca.2003.12.030","article-title":"Droplet-based microfluidic lab-on-a-chip for glucose detection","volume":"507","author":"Srinivasan","year":"2001","journal-title":"Anal. Chim. Acta"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/S0003-2670(00)01361-1","article-title":"Chemiluminescence flow sensor for in vivo on-line monitoring of glucose in awake rabbit by microdialysis sampling","volume":"432","author":"Li","year":"2001","journal-title":"Anal. Chim. Acta"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1186\/1754-1611-1-5","article-title":"Role of reaction kinetics and mass transport in glucose sensing with nanopillar array electrodes","volume":"1","author":"Anandan","year":"2007","journal-title":"J. Biol. Eng"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.jelechem.2004.08.023","article-title":"Glucose oxidase entrapped in polypyrrole on high-surface-area Pt electrodes: a model platform for sensitive electroenzymatic biosensors","volume":"575","author":"Wang","year":"2005","journal-title":"J. Electroanal. Chem"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"943","DOI":"10.1016\/S0956-5663(02)00209-9","article-title":"Immobilisation of glucose oxidase within metallic nanotubes arrays for application to enzyme biosensors","volume":"18","author":"Delvaux","year":"2003","journal-title":"Biosens. Bioelectron"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1117","DOI":"10.1016\/j.bios.2007.10.025","article-title":"Electrochemical fabrication and evaluation of highly sensitive nanorod-modified electrodes for a biotin\/avidin system","volume":"23","author":"Lee","year":"2008","journal-title":"Biosens. Bioelectron"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1088\/0957-4484\/19\/39\/395501","article-title":"Optimizing the functionalization process for nanopillar enhanced electrodes with GOx\/PPY for glucose detection","volume":"19","author":"Gangadharan","year":"2008","journal-title":"Nanotechnology"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/j.aca.2005.08.046","article-title":"Impedance spectral studies of self-assembly of alkanethiols with different chain lengths using different immobilization strategies on Au electrodes","volume":"554","author":"Ding","year":"2005","journal-title":"Anal. Chim. Acta"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S0956-5663(01)00277-9","article-title":"Self-assembled monolayers as a tunable platform for biosensor applications","volume":"17","author":"Chaki","year":"2002","journal-title":"Biosens. Bioelectron"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1016\/S0022-0728(02)00753-2","article-title":"Preparation, characterization and application of alkanethiol self-assembled monolayers modified with tetrathiafulvalene and glucose oxidase at a gold disk electrode","volume":"526","author":"Campuzano","year":"2002","journal-title":"J. Electroanal. Chem"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1385","DOI":"10.1002\/1521-4109(200111)13:17<1385::AID-ELAN1385>3.0.CO;2-L","article-title":"The influence of the underlying gold substrate on glucose oxidase electrodes fabricated using self-assembled monolayer","volume":"13","author":"Losic","year":"2001a","journal-title":"Electroanal"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Anandan, V., Rao, Y.L., and Zhang, G. (2006). Nanopillar array structures for high performance electrochemical sensing. Int. J. Nanomedicine., 1, (1).","DOI":"10.2147\/nano.2006.1.1.73"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"2687","DOI":"10.1021\/la00059a048","article-title":"Reductive desorption of alkanethiolate monolayers at gold: a measure of surface coverage","volume":"7","author":"Walczak","year":"1991","journal-title":"Langmuir"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1016\/S0022-0728(00)00430-7","article-title":"In situ STM imaging of individual molecules in two-component self-assembled monolayers of 3-mercaptopropionic acid and 1-decanethiol on Au(111)","volume":"496","author":"Sawaguchi","year":"2001","journal-title":"J. Electroanal. Chem"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1002\/elan.1140050504","article-title":"Catalytic reduction of benzoquinone at polyaniline and polyaniline enzyme films","volume":"5","author":"Cooper","year":"1993","journal-title":"Electroanal"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1016\/j.jelechem.2007.09.033","article-title":"Effects of different self-assembled monolayers on enzyme immobilization procedures in peroxidase-based biosensor development","volume":"612","author":"Mendes","year":"2008","journal-title":"J.Electroanal. Chem"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1016\/0022-0728(91)85271-P","article-title":"The electrochemical desorption of n-alkanethiol monolayers from polycrystalline Au and Ag electrodes","volume":"310","author":"Widrig","year":"1991","journal-title":"J. Electroanal. Chem"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/S0022-0728(97)00006-5","article-title":"Reductive desorption of carboxylic-acid-terminated alkanethiol monolayers from Au(111) surfaces","volume":"428","author":"Imabayashi","year":"1997","journal-title":"J. Electroanal. Chem"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"3307","DOI":"10.1021\/la001462t","article-title":"Influence of surface topography on alkanethiol SAMs assembled from solution and by microcontact printing","volume":"17","author":"Losic","year":"2001b","journal-title":"Langmuir"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"4390","DOI":"10.1143\/JJAP.41.4390","article-title":"Influence of Substrate Roughness on the Formation of Aliphatic Self-Assembled Monolayers (SAMs) on Silicon (100)","volume":"1","author":"More","year":"2002","journal-title":"Jpn. J. Appl.Phys"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/9\/3\/1295\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T22:09:55Z","timestamp":1760220595000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/9\/3\/1295"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,2,26]]},"references-count":21,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2009,3]]}},"alternative-id":["s90301295"],"URL":"https:\/\/doi.org\/10.3390\/s90301295","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,2,26]]}}}