{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T21:56:06Z","timestamp":1792101366967,"version":"4.4.0"},"reference-count":24,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2009,3,13]],"date-time":"2009-03-13T00:00:00Z","timestamp":1236902400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>In this study, use of the covalent enzyme immobilization method was proposed to attach cholesterol oxidase (ChO) on a conducting polymer, poly(3-thiopheneacetic acid), [poly(3-TPAA)]. Three red-orange poly(3-TPAA) films, named electrodes A, B and C, were electropolymerized on a platinum electrode by applying a constant current of 1.5 mA, for 5, 20 and 100 s, respectively. Further, 1-ethyl-3-(3-dimethylamiopropyl)carbodiimide hydrochloride (EDC\u2027HCl) and N-hydroxysuccinimide (NHS) were used to activate the free carboxylic groups of the conducting polymer. Afterwards, the amino groups of the cholesterol oxidase were linked on the activated groups to form peptide bonds. The best sensitivity obtained for electrode B is 4.49 mA M-1 cm-2,with a linear concentration ranging from 0 to 8 mM, which is suitable for the analysis of cholesterol in humans. The response time (t95) is between 70 and 90 s and the limit of detection is 0.42 mM, based on the signal to noise ratio equal to 3. The interference of species such as ascorbic acid and uric acid increased to 5.2 and 10.3% of the original current response, respectively, based on the current response of cholesterol (100%). With respect to the long-term stability, the sensing response retains 88% of the original current after 13 days.<\/jats:p>","DOI":"10.3390\/s90301794","type":"journal-article","created":{"date-parts":[[2009,3,13]],"date-time":"2009-03-13T13:03:00Z","timestamp":1236949380000},"page":"1794-1806","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":35,"title":["Fabricating an Amperometric Cholesterol Biosensor by a Covalent Linkage between Poly(3-thiopheneacetic acid) and Cholesterol Oxidase"],"prefix":"10.3390","volume":"9","author":[{"given":"Po-Chin","family":"Nien","sequence":"first","affiliation":[{"name":"Department of Chemical Engineering, National Taiwan University\/No. 1, Sec. 4, Roosevelt Rd., Taipei 10617, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Po-Yen","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Chemical Engineering, National Taiwan University\/No. 1, Sec. 4, Roosevelt Rd., Taipei 10617, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kuo-Chuan","family":"Ho","sequence":"additional","affiliation":[{"name":"Department of Chemical Engineering, National Taiwan University\/No. 1, Sec. 4, Roosevelt Rd., Taipei 10617, Taiwan"},{"name":"Institute of Polymer Science and Engineering, National Taiwan University\/No. 1, Sec. 4, Roosevelt Rd., Taipei 10617, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2009,3,13]]},"reference":[{"key":"ref_1","unstructured":"White, A., Handler, P., Smith, E.L., Hill, R.L., and Lehman, I.R. (1987). Principles of Biochemistry, McGraw-Hill Book. [6th Ed]."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1093\/ajcp\/27.5_ts.583","article-title":"Simple rapid microtechnic for serum total cholesterol","volume":"27","author":"Zak","year":"1957","journal-title":"Am. J. Clin. Pathol"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1307","DOI":"10.1093\/ajcp\/24.11_ts.1307","article-title":"Rapid estimation of free and total cholesterol","volume":"24","author":"Zak","year":"1954","journal-title":"Am. J. Clin. Pathol"},{"key":"ref_4","unstructured":"Cunningham, A.J. (1998). Introduction to Bioanalytical Sensors, John Wiley & Sons Inc."},{"key":"ref_5","first-page":"502","article-title":"Hydrogen peroxide biosensor based on enzyme multilayers through electrostatic adsorption","volume":"62","author":"Yang","year":"2004","journal-title":"Acta Chim. Sin"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1016\/j.aca.2003.09.064","article-title":"Amperometric cholesterol biosensor based on immobilized cholesterol esterase and cholesterol oxidase on conducting polypyrrole films","volume":"502","author":"Singh","year":"2004","journal-title":"Anal. Chim. Acta"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/S0003-2670(01)01321-6","article-title":"Amperometric determination of cholesterol in serum using a biosensor of cholesterol oxidase contained within a polypyrrole-hydrogel membrane","volume":"448","author":"Brahim","year":"2001","journal-title":"Anal. Chim. Acta"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/S0925-4005(99)00025-8","article-title":"Bioelectrochemical characteristics of cholesterol oxidase immobilized in a polyaniline film","volume":"56","author":"Wang","year":"1999","journal-title":"Sensor. Actuator. B-Chem"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"396","DOI":"10.1111\/j.1749-6632.1990.tb18185.x","article-title":"Ultramicro-H2O2 electrode for fabrication of the invivo biosensor","volume":"613","author":"Tamiya","year":"1990","journal-title":"Ann. N.Y. Acad. Sci"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"3683","DOI":"10.1016\/j.biomaterials.2004.09.024","article-title":"An amperometric urea biosensor based on covalent immobilization of urease onto an electrochemically prepared copolymer poly (N-3-aminopropyl pyrrole-co-pyrrole) film","volume":"26","author":"Rajesh","year":"2005","journal-title":"Biomaterials"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1016\/j.ab.2008.08.039","article-title":"Polyaniline-carbon nanotube composite film for cholesterol biosensor","volume":"383","author":"Dhand","year":"2008","journal-title":"Anal. Biochem"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1002\/adma.19930050211","article-title":"Polyazulenes. 5. covalent binding of glucose-oxidase to functionalized polyazulenes - The 1st application of polyazulenes in amperometric biosensors","volume":"5","author":"Schuhmann","year":"1993","journal-title":"Adv. Mater"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"5575","DOI":"10.1021\/ma00120a023","article-title":"Reactive groups on polymer-covered electrodes. 2. Functionalized thiophene polymer by electrochemical polymerization and their application polymeric reagents","volume":"28","author":"Welzel","year":"1995","journal-title":"Macromolecules"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/0302-4598(92)80051-H","article-title":"Bioelectrocatalyzed reduction of nitrate utilizing polythiophene bipyridinium enzyme electrodes","volume":"29","author":"Willner","year":"1992","journal-title":"Bioelectrochem. Bioenerg"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"3355","DOI":"10.1002\/macp.1996.021971023","article-title":"Reactive groups on polymer covered electrodes. 4. Lactate-oxidase-biosensor based on electrodes modified by polythiophene","volume":"197","author":"Welzel","year":"1996","journal-title":"Macromol. Chem. Phys"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/S0379-6779(98)00201-X","article-title":"Synthesis and properties of poly(3-thiopheneacetic acid) and its networks via electropolymerization","volume":"99","author":"Liaw","year":"1999","journal-title":"Synth. Met"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/S0003-2670(00)00792-3","article-title":"Co-immobilization of cholesterol oxidase and horseradish peroxidase in a sol-gel film","volume":"414","author":"Kumar","year":"2000","journal-title":"Anal. Chim. Acta"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1016\/S0925-4005(99)00082-9","article-title":"In situ preparation of overoxidized PPy\/oPPD bilayer biosensors for the determination of glucose and cholesterol in serum","volume":"57","author":"Vidal","year":"1999","journal-title":"Sens. Actuat. B-Chem"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/S0956-5663(97)00076-6","article-title":"Amperometric biosensor with a composite membrane of sol-gel derived enzyme film and electrochemically generated poly(1,2-diaminobenzene) film","volume":"13","author":"Yao","year":"1998","journal-title":"Biosens. Bioelectron"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1016\/S0925-4005(01)00911-X","article-title":"Layer-by-layer construction of an active multilayer enzyme electrode applicable for direct amperometric determination of cholesterol","volume":"80","author":"Gobi","year":"2001","journal-title":"Sens. Actuat. B-Chem"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/S0731-7085(00)00395-2","article-title":"Strategies for the improvement of an amperometric cholesterol biosensor based on electropolymerization in flow systems: use of charge-transfer mediators and platinization of the electrode","volume":"24","author":"Vidal","year":"2000","journal-title":"J. Pharm. Biomed. Anal"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1016\/S0039-9140(99)00057-0","article-title":"Flow injection potentiometry for enzymatic assay of cholesterol with a tungsten electrode sensor","volume":"49","author":"Situmorang","year":"1999","journal-title":"Talanta"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/0003-2670(95)00311-8","article-title":"Amperometric determination of cholesterol in serum with use of a renewable surface peroxidase electrode","volume":"318","author":"Charpentier","year":"1995","journal-title":"Anal. Chim. Acta"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/0003-2670(95)00392-4","article-title":"Improvement of the analytical characteristics of an enzyme electrode for free and total cholesterol via laponite clay additives","volume":"317","author":"Besombes","year":"1995","journal-title":"Anal. Chim. Acta"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/9\/3\/1794\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T22:10:02Z","timestamp":1760220602000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/9\/3\/1794"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,3,13]]},"references-count":24,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2009,3]]}},"alternative-id":["s90301794"],"URL":"https:\/\/doi.org\/10.3390\/s90301794","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,3,13]]}}}