{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T22:05:07Z","timestamp":1794002707722,"version":"4.8.0"},"reference-count":25,"publisher":"MDPI AG","issue":"3","license":[{"start":{"date-parts":[[2009,3,25]],"date-time":"2009-03-25T00:00:00Z","timestamp":1237939200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A novel miniature cell biosensor detection system for the detection of Hepatis B virus (HBV)-associated antigens and anti-HBV is described. The biosensor is based on \u201cmembrane-engineered\u201d Vero fibroblast cells immobilized in an alginate matrix. The membrane-engineering process involved the electroinsertion of anti-HBV specific antibodies (anti-HBs, anti-HBe) or antigens (HBsAg) in the membranes of the Vero cells. The attachment of a homologous antigen to the electroinserted antibody (or, respectively, of the antibody to the electroinserted antigen) triggered specific changes to the cell membrane potential that were measured by appropriate microelectrodes, according to the principle of the Bioelectric Recognition Assay (BERA). The sensor was used for screening 133 clinical blood serum samples according to a double-blind protocol. Considerably higher sensor responses were observed against HBV-positive samples, compared with responses against negative samples or samples positive for heterologous hepatitis viruses such as Hepatitis C (HCV) virus. Detection of anti-HBs antibodies was made possible by using a biosensor based on immobilized Vero cells bearing the respective antigen (HBsAg). The observed response was rapid (45 sec) and quite reproducible. Fluorescence microscopy observations showed that attachment of HBV particles to cells membrane-engineered with anti-HBs was associated with a decrease of [Ca2+]cyt. The perspectives for using the novel biosensor as a qualitative, rapid screening, high throughput assay for HBV antigens and anti-HBs in clinical samples is discussed.<\/jats:p>","DOI":"10.3390\/s90302176","type":"journal-article","created":{"date-parts":[[2009,3,26]],"date-time":"2009-03-26T13:02:18Z","timestamp":1238072538000},"page":"2176-2186","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":28,"title":["Development of a Novel, Ultra-rapid Biosensor for the Qualitative Detection of Hepatitis B Virus-associated Antigens and Anti-HBV, Based on \u201cMembrane-engineered\u201d Fibroblast Cells with Virus-Specific Antibodies and Antigens"],"prefix":"10.3390","volume":"9","author":[{"given":"Antonios","family":"Perdikaris","sequence":"first","affiliation":[{"name":"Laboratory of Plant Physiology, Faculty of Biotechnology, Agricultural University of Athens, Iera Odos 75, 11855 Athens, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nikos","family":"Alexandropoulos","sequence":"additional","affiliation":[{"name":"Hippokration General Hospital, Microbiology Division, Vas. Sofias Av. 114, Athens, Greece"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2841-446X","authenticated-orcid":false,"given":"Spiridon","family":"Kintzios","sequence":"additional","affiliation":[{"name":"Laboratory of Plant Physiology, Faculty of Biotechnology, Agricultural University of Athens, Iera Odos 75, 11855 Athens, Greece"},{"name":"EMBIO Diagnostics Project, Nicosia, Cyprus"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2009,3,25]]},"reference":[{"key":"ref_1","unstructured":"Baron, S. (1996). Baron's Medical Microbiology, University of Texas Medical Branch. [4th Ed]."},{"key":"ref_2","first-page":"217","article-title":"Serological markers of HBV infectivity","volume":"24","author":"Bonino","year":"1987","journal-title":"Ann. Ist. Super. Sanita"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/j.jviromet.2005.10.013","article-title":"Performance evaluation of three automated human immunodeficiency virus antigen\u2013antibody combination immunoassays","volume":"133","author":"Kwon","year":"2006","journal-title":"J. Virol. Met"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/j.jviromet.2004.01.017","article-title":"Multiplex real-time quantitative RT-PCR assay for hepatitis B virus, hepatitis C virus, and human immunodeficiency virus type 1","volume":"118","author":"Candotti","year":"2004","journal-title":"J. Virol. Met"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"837","DOI":"10.1016\/S0039-9140(01)00650-6","article-title":"Electrochemical DNA biosensor for the detection of TT and Hepatitis B virus from PCR amplified real samples by using methylene blue","volume":"56","author":"Meric","year":"2002","journal-title":"Talanta"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1501","DOI":"10.1016\/S0956-5663(03)00121-0","article-title":"Electrochemical behaviour and detection of hepatitis B virus DNA PCR production at gold electrode","volume":"18","author":"Ye","year":"2003","journal-title":"Biosens. Bioelectron"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1016\/j.elecom.2005.05.006","article-title":"Electrochemical genomagnetic assay for the detection of the hepatitis B virus DNA in polymerase chain reaction amplicons by using disposable sensor technology","volume":"7","author":"Erdem","year":"2005","journal-title":"Electrochem. Commun"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/j.bioelechem.2006.09.002","article-title":"Electrochemical detection of short sequences related to the hepatitis B virus using MB on chitosan-modified CPE","volume":"70","author":"Mandog","year":"2007","journal-title":"Bioelectrochem"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/S0731-7085(01)00538-6","article-title":"Detection of hepatitis B virus by piezoelectric biosensor","volume":"27","author":"Zhou","year":"2002","journal-title":"J. Pharm. Biomed. Anal"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1016\/j.aca.2006.09.004","article-title":"Nucleic acid biosensor for detection of hepatitis B virus using 2,9-dimethyl-1,10-phenanthroline copper complex as electrochemical indicator","volume":"582","author":"Li","year":"2007","journal-title":"Anal. Chim. Acta"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/j.jcv.2008.09.005","article-title":"Diagnosis of human hepatitis B virus in non-treated blood by the bovine IgC DNA-linked carbon nanotube biosensor","volume":"44","author":"Ly","year":"2009","journal-title":"J. Clin. Virol"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"879","DOI":"10.1016\/j.bios.2007.09.003","article-title":"Hybridization assay of hepatiis B virus by QCM peptide nucleic acid biosensor","volume":"23","author":"Yao","year":"2008","journal-title":"Biosens. Bioelectron"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1016\/j.snb.2008.06.020","article-title":"An impedemetric DNA sensor based on functionalized magnetic nanoparticles for HIV and HBV detection","volume":"134","author":"Hassen","year":"2008","journal-title":"Sens. Actuat. B Chem"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1016\/j.snb.2005.03.055","article-title":"Application of SPR biosensor for medical diagnostics of human hepatitis B virus (hHBV)","volume":"111\u2013112","author":"Chung","year":"2005","journal-title":"Sens. Actuat. B Chem"},{"key":"ref_15","first-page":"100","article-title":"A sensitive immunoassay for determination of hepatitis B surface antigen and antibody in human serum using capillary electrophoresis with chemiluminescence detection","volume":"857","author":"Zhang","year":"2007","journal-title":"J. Chromatogr"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.2174\/138955707782110141","article-title":"Cell-based sensors in clinical chemistry","volume":"7","author":"Kintzios","year":"2007","journal-title":"Mini Rev. Clin. Chem"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1016\/S0956-5663(01)00127-0","article-title":"Bioelectric Recognition Assay (BERA)","volume":"16","author":"Kintzios","year":"2001","journal-title":"Biosens. Bioelectron"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1027","DOI":"10.1016\/j.bios.2008.06.039","article-title":"Engineering of the membrane of fibroblast cells with virus-specific antibodies: A novel biosensor tool for virus detection","volume":"24","author":"Moschopoulou","year":"2008","journal-title":"Biosens. Bioelectron"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"2818","DOI":"10.3390\/s8042818","article-title":"Assessment of organophosphate and carbamate pesticide residues in cigarette tobacco with a novel cell biosensor","volume":"8","author":"Mavrikou","year":"2008","journal-title":"Sensors"},{"key":"ref_20","first-page":"1065","article-title":"Single-cell immunosensors for protein detection","volume":"18","author":"Whelan","year":"2008","journal-title":"Biosens. Bioelectron"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/j.aca.2006.01.089","article-title":"Application of \u201cmembrane-engineering\u201d to bioelectric recognition cell sensors for the detection of picomole concentrations of superoxide radical: a novel biosensor principle","volume":"573\u2013574","author":"Moschopoulou","year":"2006","journal-title":"Anal. Chim. Acta"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1016\/0166-0934(87)90101-7","article-title":"Detection and identification of plant viruses by ELISA using crude sap extracts and unfractionated antisera","volume":"15","author":"Mowat","year":"1987","journal-title":"J. Virol. Meth"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/j.bioelechem.2006.09.002","article-title":"Electrochemical detection of short sequences related to the hepatitis B virus using MB on chitosan-modified CPE","volume":"70","author":"Guo","year":"2007","journal-title":"Bioelectrochem"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"S11","DOI":"10.1016\/j.jcv.2004.02.004","article-title":"Comparison of the ADVIA centaur\u00ae and Abbott AxSYM immunoassay systems for a routine diagnostic virology laboratory","volume":"30","author":"Taylor","year":"2004","journal-title":"J. Clin. Virol"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"378","DOI":"10.3390\/s90100378","article-title":"Immobilization of electroporated cells: physiological effects of the shape of calcium alginate matrices and foetal calf serum","volume":"9","author":"Katsanakis","year":"2009","journal-title":"Sensors"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/9\/3\/2176\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T22:10:07Z","timestamp":1760220607000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/9\/3\/2176"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,3,25]]},"references-count":25,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2009,3]]}},"alternative-id":["s90302176"],"URL":"https:\/\/doi.org\/10.3390\/s90302176","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,3,25]]}}}