{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,10]],"date-time":"2026-05-10T00:51:41Z","timestamp":1778374301657,"version":"3.51.4"},"reference-count":31,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2009,4,16]],"date-time":"2009-04-16T00:00:00Z","timestamp":1239840000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Arrays of microcantilevers are increasingly being used as physical, biological, and chemical sensors in various applications. To improve the sensitivity of microcantilever sensors, this study analyses and compares the deflection and vibration characteristics of rectangular and trapezoidal profile microcantilevers. Three models of each profile are investigated. The cantilevers are analyzed for maximum deflection, fundamental resonant frequency and maximum stress. The surface stress is modelled as in-plane tensile force applied on the top edge of the microcantilevers. A commercial finite element analysis software ANSYS is used to analyze the designs. Results show paddled trapezoidal profile microcantilevers have better sensitivity.<\/jats:p>","DOI":"10.3390\/s90402706","type":"journal-article","created":{"date-parts":[[2009,4,16]],"date-time":"2009-04-16T08:37:34Z","timestamp":1239871054000},"page":"2706-2718","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":34,"title":["Comparison between Deflection and Vibration Characteristics of Rectangular and Trapezoidal profile Microcantilevers"],"prefix":"10.3390","volume":"9","author":[{"given":"Mohd. Zahid","family":"Ansari","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, Inha University, 253 Yonghyun-dong, Nam-Ku, Incheon, 402-751 Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chongdu","family":"Cho","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Inha University, 253 Yonghyun-dong, Nam-Ku, Incheon, 402-751 Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jooyong","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Inha University, 253 Yonghyun-dong, Nam-Ku, Incheon, 402-751 Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Booun","family":"Bang","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Inha University, 253 Yonghyun-dong, Nam-Ku, Incheon, 402-751 Republic of Korea"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2009,4,16]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"3793","DOI":"10.1063\/1.1144509","article-title":"A femtojoule calorimeter using micromechanical sensors","volume":"65","author":"Barnes","year":"1994","journal-title":"Rev. Sci. Instrum"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"10","DOI":"10.3390\/s8010010","article-title":"Cantilever Micro-rheometer for the Characterization of Sugar Solutions","volume":"8","author":"Hennemeyer","year":"2008","journal-title":"Sensors"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"2174","DOI":"10.3390\/s7102174","article-title":"Magnetostrictive Micro Mirrors for an Optical Switch Matrix","volume":"7","author":"Lee","year":"2007","journal-title":"Sensors"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1031","DOI":"10.1063\/1.1532836","article-title":"Piezoresistive detection of acoustic waves","volume":"74","author":"Passian","year":"2003","journal-title":"Rev. Sci.Instrum"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"3434","DOI":"10.1063\/1.1147149","article-title":"Remote optical detection using micro-cantilevers","volume":"67","author":"Wachter","year":"1996","journal-title":"Rev.Sci. Instrum"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"4466","DOI":"10.3390\/s8074466","article-title":"Cantilever measurements of surface stress, surface reconstruction, film stress and magnetoelastic stress of monolayers","volume":"8","author":"Sander","year":"2008","journal-title":"Sensors"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1595","DOI":"10.3390\/s8031595","article-title":"SU-8 cantilevers for bio\/chemical sensing; fabrication, characterisation and development of novel read-out methods","volume":"8","author":"Nordstrom","year":"2008","journal-title":"Sensors"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"7144","DOI":"10.3390\/s8117144","article-title":"NO2 detection using microcantilever based potentiometry","volume":"8","author":"Qazi","year":"2008","journal-title":"Sensors"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"235502","DOI":"10.1088\/0957-4484\/19\/23\/235502","article-title":"Label-free ultra-sensitive detection of atrazine based on nanomechanics","volume":"19","author":"Suri","year":"2008","journal-title":"Nanotechnol"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"9783","DOI":"10.1073\/pnas.152330199","article-title":"Multiple label-free biodetection and quantitative DNA-binding assays on a nanomechanical cantilever array","volume":"99","author":"McKendry","year":"2002","journal-title":"Proc. Natl. Acad. Sci"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1088\/0957-4484\/14\/1\/319","article-title":"Label-free protein assay based on a nanomechanical cantilever array","volume":"14","author":"Arntz","year":"2003","journal-title":"Nanotechnol"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1038\/nnano.2006.134","article-title":"Rapid and label-free nanomechanical detection of biomarker transcripts in human RNA","volume":"1","author":"Zhang","year":"2006","journal-title":"Nature Nanotechnol"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"384007","DOI":"10.1088\/0957-4484\/19\/38\/384007","article-title":"Label-free detection of amyloid growth with microcantilever sensors","volume":"19","author":"Knowles","year":"2008","journal-title":"Nanotechnol"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1038\/nnano.2008.91","article-title":"Label-free detection of DNAhybridization based on hydrationinduced tension in nucleic acid films","volume":"3","author":"Mertens","year":"2008","journal-title":"Nature Nanotechnol"},{"key":"ref_15","unstructured":"Ibach, H. (2006). Physics of surfaces and interfaces, Springer-Verlag."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"2423","DOI":"10.1063\/1.1791731","article-title":"Development of a biosensor based on laser-fabricated polymer microcantilevers","volume":"85","author":"Zhang","year":"2004","journal-title":"Appl. Phys. Lett"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1016\/j.ultramic.2005.06.039","article-title":"Highly sensitive polymer-based cantilever-sensors for DNA detection","volume":"105","author":"Calleja","year":"2005","journal-title":"Ultramicroscopy"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1621","DOI":"10.1016\/j.mee.2006.01.175","article-title":"SU8 bio-chemical sensor microarrays","volume":"83","author":"Ransley","year":"2006","journal-title":"Microelectron. Eng"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"173505","DOI":"10.1063\/1.2364843","article-title":"Polymeric cantilever-based biosensor with integrated readout","volume":"89","author":"Johansson","year":"2006","journal-title":"Appl. Phys. Lett"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1757","DOI":"10.3390\/s7091757","article-title":"Study of the origin of bending induced by bimetallic effect on microcantilevers","volume":"7","author":"Ramos","year":"2007","journal-title":"Sensors"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"7530","DOI":"10.3390\/s8117530","article-title":"A study on increasing sensitivity of rectangular microcantilevers used in biosensors","volume":"8","author":"Ansari","year":"2008","journal-title":"Sensors"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1120","DOI":"10.1016\/j.mee.2008.01.082","article-title":"Crystalline silicon cantilevers for piezoresistive detection of biomolecular forces","volume":"85","author":"Villanueva","year":"2008","journal-title":"Microelectron. Eng"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"7652","DOI":"10.1088\/0022-3727\/40\/24\/009","article-title":"Improved cantilever profiles for sensor elements","volume":"40","author":"Fernando","year":"2007","journal-title":"J. Phys. D: Appl. Phys"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1098\/rspa.1909.0021","article-title":"The tension of metallic films deposited by electrolysis","volume":"82","author":"Stoney","year":"1909","journal-title":"Proc. Roy. Soc. Lond. A"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/S0039-6028(99)01174-7","article-title":"Bending of crystalline plates under the influence of surface stress \u2014a finite element analysis","volume":"446","author":"Dahmen","year":"2000","journal-title":"Surface Sci"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/S0304-8853(00)01392-5","article-title":"A finite element analysis of the bending of crystalline plates due to anisotropic surface and film stress applied to magnetoelasticity","volume":"231","author":"Dahmen","year":"2001","journal-title":"J. Magn. Magn. Mater"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"2911","DOI":"10.1063\/1.1342018","article-title":"Surface stress induced deflections of cantilever plates with applications to the atomic force microscope: Rectangular plates","volume":"89","author":"Sader","year":"2001","journal-title":"J. Appl. Phy"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1269","DOI":"10.1006\/jsvi.1999.2572","article-title":"Cantilever beam vibrations","volume":"229","author":"Hoffman","year":"2000","journal-title":"J. Sound Vib"},{"key":"ref_29","first-page":"259","article-title":"A comparative study of wet vs. dry isotropic etch to strengthen silicon micro-machined pressure sensor","volume":"27","author":"Sooriakumar","year":"1995","journal-title":"Electrocheml Soc. Proc"},{"key":"ref_30","unstructured":"Timoshenko, S.P., and Woinowsky-Krieger, S. (1959). Theory of plates and shells, McGraw Hill. [2nd Ed]."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"2894","DOI":"10.1063\/1.111407","article-title":"Thermal, ambient-induced deflections of scanning force microscope cantilevers","volume":"64","author":"Thundat","year":"1994","journal-title":"Appl. Phys. Lett"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/9\/4\/2706\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T22:10:14Z","timestamp":1760220614000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/9\/4\/2706"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,4,16]]},"references-count":31,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2009,4]]}},"alternative-id":["s90402706"],"URL":"https:\/\/doi.org\/10.3390\/s90402706","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,4,16]]}}}