{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T22:41:56Z","timestamp":1791240116464,"version":"4.1.0"},"reference-count":29,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2009,4,23]],"date-time":"2009-04-23T00:00:00Z","timestamp":1240444800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>A comprehensive review of film-sensors shows that they are primarily operated in a passive mode, i.e. without being actively heated to an extent, whereby they create a heat transfer situation on their own. Only when these sensors are used for wall shear stress measurements, the detection of laminar\/turbulent transition, or the measurement of certain flow velocities, they are operated in an active mode, i.e. heated by an electrical current (after an appropriate calibration). In our study we demonstrate how these R(T)-based sensors (temperature dependence of the electrical resistance R) can also be applied in an active mode for heat transfer measurements. These measurements can be made on cold, unheated bodies, provided certain requirements with respect to the flow field are fulfilled. Our new sensors are laminated nickel- and polyimide-foils manufactured with a special technology, which is also described in detail.<\/jats:p>","DOI":"10.3390\/s90403011","type":"journal-article","created":{"date-parts":[[2009,4,23]],"date-time":"2009-04-23T05:35:33Z","timestamp":1240464933000},"page":"3011-3032","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Heat Transfer Measurements with Surface Mounted Foil-Sensors in an Active Mode: A Comprehensive Review and a New Design"],"prefix":"10.3390","volume":"9","author":[{"given":"Horst","family":"Mocikat","sequence":"first","affiliation":[{"name":"Hamburg University of Technology, Institute of Thermo-Fluid Dynamics, Denickestr. 17, D 21073 Hamburg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Heinz","family":"Herwig","sequence":"additional","affiliation":[{"name":"Hamburg University of Technology, Institute of Thermo-Fluid Dynamics, Denickestr. 17, D 21073 Hamburg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2009,4,23]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1016\/j.sna.2006.07.019","article-title":"Flexible thin film temperature and strain sensor array utilizing a novel sensing concept","volume":"135","author":"Lichtenwalner","year":"2007","journal-title":"Sens. Actuat. A"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"933","DOI":"10.1016\/j.ijheatfluidflow.2004.02.027","article-title":"An investigation of the heat transfer and static pressure on the over-tip casing of an axial turbine operating at engine representative flow conditions. (I). Time-mean results","volume":"25","author":"Thorpe","year":"2004","journal-title":"Int. J. Heat Fluid Flow"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"945","DOI":"10.1016\/j.ijheatfluidflow.2004.02.028","article-title":"An investigation of the heat transfer and static pressure on the over-tip casing of an axial turbine operating at engine representative flow conditions. (II). Time-resolved results","volume":"25","author":"Thorpe","year":"2004","journal-title":"Int. J. Heat Fluid Flow"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1088\/0957-0233\/11\/4\/302","article-title":"The development of a new direct-heat-flux gauge for heat-transfer facilities","volume":"11","author":"Piccini","year":"2000","journal-title":"Meas. Sci. Technol"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1088\/0957-0233\/9\/3\/017","article-title":"Design optimization for fast heat-transfer gauges","volume":"9","author":"Hogendoorn","year":"1998","journal-title":"Meas. Sci. Technol"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1063\/1.1138882","article-title":"High-frequency response heat-flux gauge","volume":"57","author":"Epstein","year":"1986","journal-title":"Rev. Sci. Instrum"},{"key":"ref_7","unstructured":"Fralick, G., Wrbanek, J., and Blaha, C. Thin film heat flux sensor of improved design. NASA\/TM-2002-211566."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1007\/s00231-006-0095-9","article-title":"An advanced thin foil sensor concept for heat flux and heat transfer measurements in fully turbulent flows","volume":"43","author":"Mocikat","year":"2007","journal-title":"Heat Mass Transfer"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Stefanescu, S., DeAnna, R.G., and Mehregany, M. Experimental performance of a micromachined heat flux sensor. NASA\/TM-1998-107517.","DOI":"10.2514\/6.1997-3034"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1428","DOI":"10.1088\/0957-0233\/7\/10\/013","article-title":"Calibration of single-surface hot films and in-line hot-film arrays in laminar or turbulent flows","volume":"7","author":"Haselbach","year":"1996","journal-title":"Meas. Sci. Technol"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1016\/S0376-0421(02)00031-3","article-title":"Modern developments in shear-stress measurement","volume":"38","author":"Naughton","year":"2002","journal-title":"Progr. Aerospace Sci"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1007\/s003480200004","article-title":"Multiple hot-film sensor array calibration and skin friction measurement","volume":"32","author":"Desgeorges","year":"2002","journal-title":"Exp. Fluid"},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1016\/j.sna.2006.02.006","article-title":"Characterization of a miniature thermal shear-stress sensor with backside connections","volume":"128","author":"Kim","year":"2006","journal-title":"Sens. Actuat. A"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"665","DOI":"10.1088\/0957-0233\/10\/8\/302","article-title":"MEMS-based pressure and shear stress sensors for turbulent flows","volume":"10","year":"1999","journal-title":"Meas. Sci. Technol"},{"key":"ref_15","first-page":"90","article-title":"A micromachined flow shear stress sensor based on thermal transfer principles","volume":"8","author":"Liu","year":"1999","journal-title":"J. Micro. Elec. Mech. Sys"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1016\/j.sna.2004.12.022","article-title":"A MEMS multe-sensor chip for gas flow sensing","volume":"121","author":"Xu","year":"2005","journal-title":"Sens. Actuat. A"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1007\/s00348-005-0969-5","article-title":"Dynamic calibration technique for thermal shear-stress sensors with mean flow","volume":"39","author":"Chandrasekaran","year":"2005","journal-title":"Exp. Fluid"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1007\/s003480050214","article-title":"Measurement of unsteady boundary layer developed on an oscillating airfoil using multiple hot-film sensors","volume":"25","author":"Lee","year":"1998","journal-title":"Exp. Fluid"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1016\/S0924-4247(99)00277-0","article-title":"A flexible micromachine-based shear-stress sensor array and its application to separation-point detection","volume":"79","author":"Jiang","year":"2000","journal-title":"Sens. Actuat"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1016\/S0924-4247(03)00230-9","article-title":"Flexible shear-stress sensor skin and its application to unmanned aerial vehicles","volume":"105","author":"Xu","year":"2003","journal-title":"Sens. Actuat. A"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"2131","DOI":"10.1088\/0957-0233\/12\/12\/314","article-title":"Thermal flow sensor for ultra-low velocities based on printed circuit board technology","volume":"12","author":"Nguyen","year":"2001","journal-title":"Meas. Sci. Technol"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/S0924-4247(01)00668-9","article-title":"Anemometer with hot platinum thin film","volume":"94","author":"Mailly","year":"2001","journal-title":"Sens. Actuat. A"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1088\/0960-1317\/16\/4\/009","article-title":"A micromachined thin-film gas flow sensor for microchemical reactors","volume":"16","author":"Shin","year":"2006","journal-title":"J. Micromech. Microeng"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1016\/j.sna.2003.12.019","article-title":"Measurement of flow direction and velocity using a micromachined flow sensor","volume":"114","author":"Kim","year":"2004","journal-title":"Sens. Actuat. A"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1016\/j.sna.2003.10.068","article-title":"Multi-range silicon micromachined flow sensor","volume":"110","author":"Santander","year":"2004","journal-title":"Sens. Actuat. A"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1016\/j.sna.2004.04.050","article-title":"Thermal characterisation of a direction dependent flow sensor","volume":"115","year":"2004","journal-title":"Sens. Actuat. A"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1016\/j.sna.2006.11.012","article-title":"EPMA and XRD study on nickel metal thin film for temperature sensor","volume":"136","author":"Weiping","year":"2007","journal-title":"Sens. Actuat. A"},{"key":"ref_28","unstructured":"Herwig, H. (2002). Springer-Verlag."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1107","DOI":"10.1007\/s00231-007-0336-6","article-title":"Heat transfer measurements in fully turbulent flows: basic investigations with an advanced thin foil triple sensor","volume":"44","author":"Mocikat","year":"2008","journal-title":"Heat Mass Transfer"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/9\/4\/3011\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T22:10:17Z","timestamp":1760220617000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/9\/4\/3011"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,4,23]]},"references-count":29,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2009,4]]}},"alternative-id":["s90403011"],"URL":"https:\/\/doi.org\/10.3390\/s90403011","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,4,23]]}}}