{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T04:39:41Z","timestamp":1760243981936,"version":"build-2065373602"},"reference-count":15,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2009,5,6]],"date-time":"2009-05-06T00:00:00Z","timestamp":1241568000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Although ultrasound cavitation must be avoided for safe diagnostic applications, the ability of ultrasound to disrupt cell membranes has taken on increasing significance as a method to facilitate drug and gene delivery. A new ultrasonic resonance driving method is introduced to penetrate rigid wall plant cells or oocytes with springy cell membranes. When a reasonable design is created, ultrasound can gather energy and increase the amplitude factor. Ultrasonic penetration enables exogenous materials to enter cells without damaging them by utilizing instant acceleration. This paper seeks to develop a miniature ultrasonic probe experiment system for cell penetration. A miniature ultrasonic probe is designed and optimized using the Precise Four Terminal Network Method and Finite Element Method (FEM) and an ultrasonic generator to drive the probe is designed. The system was able to successfully puncture a single fish cell.<\/jats:p>","DOI":"10.3390\/s90503325","type":"journal-article","created":{"date-parts":[[2009,5,6]],"date-time":"2009-05-06T12:56:49Z","timestamp":1241614609000},"page":"3325-3336","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["A Miniature Probe for Ultrasonic Penetration of a Single Cell"],"prefix":"10.3390","volume":"9","author":[{"given":"Ting","family":"Wu","sequence":"first","affiliation":[{"name":"MEMS Lab, Department of Precision Instruments & Mechanology, Tsinghua University, Beijing 100084, P.R. China"},{"name":"School of Information Technology, China University of Geosciences (Beijing), Beijing 100083, P.R. China"},{"name":"State Key Laboratory of Precision Measurement Technology and Instruments, Tsinghua University, Beijing 100084, P.R. China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhaoying","family":"Zhou","sequence":"additional","affiliation":[{"name":"MEMS Lab, Department of Precision Instruments & Mechanology, Tsinghua University, Beijing 100084, P.R. China"},{"name":"State Key Laboratory of Precision Measurement Technology and Instruments, Tsinghua University, Beijing 100084, P.R. China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qun","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Information Technology, China University of Geosciences (Beijing), Beijing 100083, P.R. China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xing","family":"Yang","sequence":"additional","affiliation":[{"name":"MEMS Lab, Department of Precision Instruments & Mechanology, Tsinghua University, Beijing 100084, P.R. China"},{"name":"State Key Laboratory of Precision Measurement Technology and Instruments, Tsinghua University, Beijing 100084, P.R. China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mingfei","family":"Xiao","sequence":"additional","affiliation":[{"name":"MEMS Lab, Department of Precision Instruments & Mechanology, Tsinghua University, Beijing 100084, P.R. China"},{"name":"State Key Laboratory of Precision Measurement Technology and Instruments, Tsinghua University, Beijing 100084, P.R. China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2009,5,6]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1016\/S0924-4247(03)00050-5","article-title":"Microfabricated electroporation chip for single cell membrane permeabilization","volume":"104","author":"Huang","year":"2003","journal-title":"Sens. Actuat. A-Phys."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.sna.2003.05.002","article-title":"A microchip for electroporation of primary endothelial cells","volume":"108","author":"Lin","year":"2003","journal-title":"Sens. Actuat. A-Phys."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1038\/337387a0","article-title":"Cationic liposome-mediated transfection","volume":"337","author":"Felgner","year":"1989","journal-title":"Nature"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"1188","DOI":"10.1126\/science.289.5482.1188","article-title":"Pig cloning by microinjection of fetal fibroblast nuclei","volume":"289","author":"Onishi","year":"2000","journal-title":"Science"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1021\/nl0485399","article-title":"Nanoscale operation of a living cell using an atomic force microscope with a nanoneedle","volume":"5","author":"Obataya","year":"2005","journal-title":"Nano Lett."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"173901","DOI":"10.1063\/1.2112183","article-title":"Carbon nanotube probes for single-cell experimentation and assays","volume":"87","author":"Kouklin","year":"2005","journal-title":"Appl. Phys. Lett."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1007\/BF00656997","article-title":"Improved Patch-Clamp Techniques for High-Resolution Current Recording from Cells and Cell-Free Membrane Patches","volume":"391","author":"Hamill","year":"1981","journal-title":"Pfl\u00fcgers Arch."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1038\/nature02246","article-title":"The mitochondrial calcium uniporter is a highly selective ion channel","volume":"427","author":"Kirichok","year":"2004","journal-title":"Nature"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"2970","DOI":"10.1016\/S0006-3495(02)75638-5","article-title":"Single cell mechanotransduction and its modulation analyzed by atomic force microscope indentation","volume":"82","author":"Charras","year":"2002","journal-title":"Biophys. J."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"2746","DOI":"10.1016\/S0006-3495(03)74697-9","article-title":"Adhesively-tensed cell membranes: lysis kinetics and atomic force microscopy probing","volume":"85","author":"Hategan","year":"2003","journal-title":"Biophys. J."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1109\/TBME.2003.820323","article-title":"Prediction of ultrasound-mediated disruption of cell membranes using machine learning techniques and statistical analysis of acoustic spectra","volume":"51","author":"Lee","year":"2004","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"2935","DOI":"10.1063\/1.107468","article-title":"Nanotips by reverse electrochemical etching","volume":"60","author":"Fotino","year":"1992","journal-title":"Appl. Phys. Lett."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1016\/j.ultrasmedbio.2005.12.012","article-title":"Effects of different tissue loads on high power ultrasonic surgery scalpel","volume":"32","author":"Chen","year":"2006","journal-title":"Ultrasound Med. Biol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1109\/10.581934","article-title":"Development and application of ultrasonic surgical instruments","volume":"44","author":"Sun","year":"1997","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"872","DOI":"10.1109\/58.935703","article-title":"Finite element simulation of piezoelectric transformers","volume":"48","author":"Tsuchiya","year":"2001","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq Control"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/9\/5\/3325\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T22:10:21Z","timestamp":1760220621000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/9\/5\/3325"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,5,6]]},"references-count":15,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2009,5]]}},"alternative-id":["s90503325"],"URL":"https:\/\/doi.org\/10.3390\/s90503325","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2009,5,6]]}}}