{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,24]],"date-time":"2025-11-24T23:40:39Z","timestamp":1764027639084,"version":"build-2065373602"},"reference-count":49,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2009,5,11]],"date-time":"2009-05-11T00:00:00Z","timestamp":1242000000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The aim of this paperis to summarize the efforts carried out so far in the fabrication of Si-based biosensors by a team of researchers in Catania, Italy. This work was born as a collaboration between the Catania section of the Microelectronic and Microsystem Institute (IMM) of the CNR, the Surfaces and Interfaces laboratory (SUPERLAB) of the Consorzio Catania Ricerche and two departments at the University of Catania: the Biomedical Science and the Biological Chemistry and Molecular Biology Departments. The first goal of our study was the definition and optimization of an immobilization protocol capable of bonding the biological sensing element on a Si-based surface via covalent chemical bonds. We chose SiO2 as the anchoring surface due to its biocompatibility and extensive presence in microelectronic devices. The immobilization protocol was tested and optimized, introducing a new step, oxide activation, using techniques compatible with microelectronic processing. The importance of the added step is described by the experimental results. We also tested different biological molecule concentrations in the immobilization solutions and the effects on the immobilized layer. Finally a MOS-like structure was designed and fabricated to test an electrical transduction mechanism. The results obtained so far and the possible evolution of the research field are described in this review paper.<\/jats:p>","DOI":"10.3390\/s90503469","type":"journal-article","created":{"date-parts":[[2009,5,11]],"date-time":"2009-05-11T12:36:56Z","timestamp":1242045416000},"page":"3469-3490","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Feasibility Studies on Si-Based Biosensors"],"prefix":"10.3390","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5874-7284","authenticated-orcid":false,"given":"Sebania","family":"Libertino","sequence":"first","affiliation":[{"name":"CNR \u2013 IMM Catania, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Venera","family":"Aiello","sequence":"additional","affiliation":[{"name":"Universit\u00e0 degli Studi di Catania, Dipartimento di Chimica Biologica, Chimica Medica e Biologia Molecolare, Catania, Italy"},{"name":"Universit\u00e0 degli Studi di Catania, Dipartimento di Scienze Biomediche, Catania, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Antonino","family":"Scandurra","sequence":"additional","affiliation":[{"name":"Laboratorio Superfici e Interfasi (SUPERLAB), Consorzio Catania Ricerche, Catania, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marcella","family":"Renis","sequence":"additional","affiliation":[{"name":"Universit\u00e0 degli Studi di Catania, Dipartimento di Chimica Biologica, Chimica Medica e Biologia Molecolare, Catania, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fulvia","family":"Sinatra","sequence":"additional","affiliation":[{"name":"Universit\u00e0 degli Studi di Catania, Dipartimento di Scienze Biomediche, Catania, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Salvatore","family":"Lombardo","sequence":"additional","affiliation":[{"name":"CNR \u2013 IMM Catania, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2009,5,11]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1111\/j.1749-6632.1962.tb13623.x","article-title":"Electrode systems for continuous monitoring in cardiovascular surgery","volume":"102","author":"Clark","year":"1962","journal-title":"Ann. N.Y. Acad. Sci."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1016\/S0167-7799(00)01453-0","article-title":"Biotechnological applications of lab-chips and microarrays","volume":"18","author":"Jain","year":"2000","journal-title":"Trends Biotechnol."},{"key":"ref_3","unstructured":"Ramsay, G. (1998). Commercial Biosensors: Applications to Clinical, Bioprocess, and Environmental Samples, Wiley."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1016\/0167-7799(85)90119-2","article-title":"Immunosensors: Antibody-Based Biosensors","volume":"3","author":"North","year":"1985","journal-title":"Trends Biotechnol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1002\/bit.1065","article-title":"Adsorption of Avidin on Microfabricated Surfaces for Protein Biochip Applications","volume":"73","author":"Bashir","year":"2001","journal-title":"Biotechn. Bioengineer."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1007\/s002160051549","article-title":"Biosensors and Biochips, Advances in Biological and Medical Diagnostics","volume":"366","author":"Cullum","year":"2000","journal-title":"Fresenius J. Anal. Chem."},{"key":"ref_7","unstructured":"Hall, E.A.H. (1990). Biosensors, Open University Press."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1002\/1521-4109(200005)12:9<645::AID-ELAN645>3.0.CO;2-O","article-title":"The use of insect chemoreceptors for the assembly of biosensors based on semiconductor field-effect sensors","volume":"12","author":"Schroth","year":"2000","journal-title":"Electroanalysis"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"2637","DOI":"10.1021\/ac020239t","article-title":"Micro Total Analysis Systems. 2. Analytical Standard operations and Applications","volume":"74","author":"Auroux","year":"2002","journal-title":"Anal. Chem."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1039\/B400894D","article-title":"Microfluidic biosensing systems Part I. Development and optimisation of enzymatic chemiluminescent m-biosensors based on silicon microchips","volume":"4","author":"Davidsson","year":"2004","journal-title":"Lab Chip"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"2980","DOI":"10.1021\/jp963056h","article-title":"Direct Detection of the Hybridization of Synthetic Homo-Oligomer DNA Sequences by Field Effect","volume":"101","author":"Souteyrand","year":"1997","journal-title":"J. Phys. Chem. B"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"2374","DOI":"10.1021\/ac00172a011","article-title":"Direct detection of immunospecies by capacitance. measurements","volume":"60","author":"Bataillard","year":"1988","journal-title":"Anal. Chem."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1912","DOI":"10.1002\/elan.200403080","article-title":"Detection of DNA and Protein Molecules Using an FET-Type Biosensor with Gold as a Gate Metal","volume":"16","author":"Shin","year":"2004","journal-title":"Electroanalysis"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1002\/cbic.200400253","article-title":"Potentiometric Detection of Single Nucleotide Polymorphism by Using a Genetic Field-effect transistor","volume":"6","author":"Sakata","year":"2005","journal-title":"ChemBioChem"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/S1381-1177(99)00023-5","article-title":"Enzyme immobilisation on planar and porous silicon substrates for biosensor applications","volume":"7","author":"Thust","year":"1999","journal-title":"J. Molec. Cat. B: Enzymatic"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1681","DOI":"10.1002\/(SICI)1521-3765(19990604)5:6<1681::AID-CHEM1681>3.0.CO;2-U","article-title":"Towards Genoelectronics: Electrochemical Biosensing of DNA Hybridization","volume":"5","author":"Wang","year":"1999","journal-title":"Chem. Eur. J."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S0003-2670(96)00598-3","article-title":"DNA electrochemical biosensors for environmental monitoring. A review","volume":"347","author":"Wang","year":"1997","journal-title":"Analyt. Chim. Acta"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"1137","DOI":"10.1039\/B204444G","article-title":"Recent advances in biologically sensitive field-effect transistors (BioFETs)","volume":"127","author":"Poghossian","year":"2002","journal-title":"Analyst"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1002\/1521-4109(200103)13:3<173::AID-ELAN173>3.0.CO;2-B","article-title":"Capacitive biosensors","volume":"13","author":"Berggren","year":"2001","journal-title":"Electroanalysis"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1893","DOI":"10.1002\/elan.200603609","article-title":"Bio FEDs (Field-Effect Devices): State-of-the-Art and New Directions","volume":"18","author":"Poghossian","year":"2006","journal-title":"Electroanalysis"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1007\/s00216-006-0398-1","article-title":"New insights from X-ray photoelectron spectroscopy into the chemistry of covalent enzyme immobilization, with glutamate dehydrogenase (GDH) on silicon dioxide as an example","volume":"385","author":"Longo","year":"2006","journal-title":"Anal. Bioanal. Chem."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/S0379-6779(02)01276-6","article-title":"Optical and structural characterization of bacterio-rhodopsin films on Si-based materials","volume":"138","author":"Libertino","year":"2003","journal-title":"Synth. Met."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/S0925-4005(03)00096-0","article-title":"Immobilization of DNA on CMOS compatible materials","volume":"92","author":"Lobert","year":"2003","journal-title":"Sens. Actuat."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"546","DOI":"10.1016\/j.talanta.2004.03.050","article-title":"Biosensors for determination of glucose with glucose oxidase immobilized on an eggshell membrane","volume":"64","author":"Wu","year":"2004","journal-title":"Talanta"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/S0141-0229(98)00084-2","article-title":"Comparison of techniques for enzyme immobilization on silicon supports","volume":"24","author":"Subramanian","year":"1999","journal-title":"Enzyme Microb. Technol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/S0379-6779(02)01271-7","article-title":"Characterization and patterning of bacteriorhodopsin films on Si-based materials","volume":"138","author":"Libertino","year":"2003","journal-title":"Synth. Met."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/S0039-9140(01)00600-2","article-title":"Improved performance in silicon enzyme microreactors obtained by homogeneous porous silicon carrier matrix","volume":"56","author":"Bengtsson","year":"2002","journal-title":"Talanta"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1016\/j.jbiotec.2005.07.014","article-title":"Preparation of a very stable immobilized biocatalyst of glucose oxidase from Aspergillus niger","volume":"121","author":"Betancor","year":"2006","journal-title":"J. Biotechnol."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"622","DOI":"10.1016\/0022-0248(85)90029-6","article-title":"An experimental and theoretical study of the formation and microstructure of porous silicon","volume":"73","author":"Beale","year":"1985","journal-title":"J. Cryst. Growth"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1016\/j.mee.2006.10.064","article-title":"Experimental characterization of proteins immobilized on Si-based materials","volume":"84","author":"Libertino","year":"2007","journal-title":"Microelect. Eng."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"9116","DOI":"10.1016\/j.apsusc.2007.05.039","article-title":"Layer uniformity in glucose oxidase immobilization on SiO2 surfaces","volume":"253","author":"Libertino","year":"2007","journal-title":"Appl. Surf. Sci."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1006\/jmbi.1993.1015","article-title":"Crystal structure of glucose oxidase from Aspergillus niger refined at 2.3 A resolution","volume":"229","author":"Hecht","year":"1993","journal-title":"J. Mol. Biol."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1016\/0956-5663(92)87013-F","article-title":"Glucose oxidase: an ideal enzyme","volume":"7","author":"Wilson","year":"1992","journal-title":"Bios. Bioelectron."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/0925-4005(96)80061-X","article-title":"Enhanced enzyme activity in silicon integrated enzyme reactors utilizing porous silicon as the coupling matrix","volume":"31","author":"Laurell","year":"1996","journal-title":"Sens. Actuat. B"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1016\/j.cap.2004.06.021","article-title":"Recent trends in biosensors","volume":"5","author":"Malhotra","year":"2005","journal-title":"Curr. Appl. Phys."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1038\/171737a0","article-title":"A structure for Deoxyribose Nucleic Acid","volume":"171","author":"Watson","year":"1953","journal-title":"Nature"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1002\/elan.1140080104","article-title":"Electrochemical Biosensors for DNA Sequence Detection","volume":"8","author":"Mikkelsen","year":"1996","journal-title":"Electroanalysis"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1007\/s00018-002-8454-2","article-title":"Metallothionein: the multipurpose protein","volume":"59","author":"Coyle","year":"2002","journal-title":"Cell. Mol. Life Sci."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"1501","DOI":"10.1073\/pnas.80.6.1501","article-title":"Model for mammalian metallothionein structure","volume":"80","author":"Boulanger","year":"1983","journal-title":"Proc. Natl. Acad. Sci."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"1965","DOI":"10.1021\/la7029664","article-title":"XPS and AFM characterization of the enzyme glucose oxidase immobilized on SiO2 surfaces","volume":"24","author":"Libertino","year":"2008","journal-title":"Langmuir"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1166\/sl.2008.424","article-title":"Electrical characterization of biological molecules deposition in MOS capacitors","volume":"6","author":"Libertino","year":"2008","journal-title":"Sens. Letts"},{"key":"ref_42","unstructured":"Aiello, V., Libertino, S., Scandurra, A., Sinatra, F., and Renis, M. Feasibility study of a Si-based multisensor. Thin solid films, submitted."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"163108","DOI":"10.1063\/1.2196069","article-title":"Quantitative analysis of the sensitivity of porous silicon optical biosensors","volume":"88","author":"Ouyang","year":"2006","journal-title":"Appl. Phys. Lett."},{"key":"ref_44","unstructured":"Briggs, D., and Seah, M.P. (1990). Practical Surface Analysis, John Wiley & Sons. [2nd ed]."},{"key":"ref_45","unstructured":"Beamson, G., and Briggs, D. (2000). The XPS of Polymers Database, Surf. Spectra Publisher."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"5637","DOI":"10.3390\/s8095637","article-title":"Immobilization of the enzyme glucose oxidase immobilization on both bulk and porous SiO2 surfaces","volume":"8","author":"Libertino","year":"2008","journal-title":"Sensors"},{"key":"ref_47","doi-asserted-by":"crossref","unstructured":"Arrabito, G., Musumeci, C., Aiello, V., Libertino, S., Compagnini, G., and Pignataro, B. (2009). On the relationship between jetted inks and printed bio-patterns: molecular-thin functional micro-arrays of glucose oxidase. Langmuir.","DOI":"10.1021\/la900071z"},{"key":"ref_48","unstructured":"Libertino, S, Cannella, G., Aiello, V., Lombardo, S., and Busacca, A. Electrical characterization of DNA hybridization in MOS-like structures, submitted for publication on. Appl. Phys. Lett."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"253901","DOI":"10.1063\/1.2149981","article-title":"Enzyme-immobilized SiO2\u2013Si electrode: Fast interfacial electron transfer with preserved enzymatic activity","volume":"87","author":"Wang","year":"2005","journal-title":"Appl. Phys. Lett."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/9\/5\/3469\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T22:10:22Z","timestamp":1760220622000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/9\/5\/3469"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,5,11]]},"references-count":49,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2009,5]]}},"alternative-id":["s90503469"],"URL":"https:\/\/doi.org\/10.3390\/s90503469","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2009,5,11]]}}}