{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,17]],"date-time":"2026-11-17T04:15:04Z","timestamp":1794888904008,"version":"4.9.1"},"reference-count":108,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2009,5,12]],"date-time":"2009-05-12T00:00:00Z","timestamp":1242086400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>Over the last decade, cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) wide band gap semiconductors have attracted increasing interest as X-ray and gamma ray detectors. Among the traditional high performance spectrometers based on silicon (Si) and germanium (Ge), CdTe and CdZnTe detectors show high detection efficiency and good room temperature performance and are well suited for the development of compact and reliable detection systems. In this paper, we review the current status of research in the development of CdTe and CdZnTe detectors by a comprehensive survey on the material properties, the device characteristics, the different techniques for improving the overall detector performance and some major applications. Astrophysical and medical applications are discussed, pointing out the ongoing Italian research activities on the development of these detectors.<\/jats:p>","DOI":"10.3390\/s90503491","type":"journal-article","created":{"date-parts":[[2009,5,12]],"date-time":"2009-05-12T11:59:55Z","timestamp":1242129595000},"page":"3491-3526","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":788,"title":["Progress in the Development of CdTe and CdZnTe Semiconductor Radiation Detectors for Astrophysical and Medical Applications"],"prefix":"10.3390","volume":"9","author":[{"given":"Stefano","family":"Del Sordo","sequence":"first","affiliation":[{"name":"INAF\/IASF Palermo, Via Ugo La Malfa 153, 90146 Palermo, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leonardo","family":"Abbene","sequence":"additional","affiliation":[{"name":"INAF\/IASF Palermo, Via Ugo La Malfa 153, 90146 Palermo, Italy"},{"name":"Dipartimento di Fisica e Tecnologie Relative, Universit\u00e0 di Palermo,Viale delle Scienze, 90128 Palermo, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ezio","family":"Caroli","sequence":"additional","affiliation":[{"name":"INAF\/IASF Bologna, Via Gobetti 101, 40129 Bologna, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna Maria","family":"Mancini","sequence":"additional","affiliation":[{"name":"Dipartimento di Ingegneria dell\u2019Innovazione, Universit\u00e0 del Salento, Via Arnesano, 73100 Lecce, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Zappettini","sequence":"additional","affiliation":[{"name":"IMEM-CNR, Parco Area delle Scienze 37\/A, 43100 Parma, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pietro","family":"Ubertini","sequence":"additional","affiliation":[{"name":"INAF\/IASF Roma, Via del Fosso del Cavaliere 100, 00133 Roma, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2009,5,12]]},"reference":[{"key":"ref_1","unstructured":"Knoll, G.F. (1999). Radiation Detection and Measurement, Wiley. [3rd Ed.]."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/S0168-9002(97)00620-7","article-title":"Room-temperature compound semiconductor radiation detectors","volume":"395","author":"McGregor","year":"1997","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1016\/j.nima.2004.05.071","article-title":"Compound semiconductor radiation detectors","volume":"531","author":"Owens","year":"2004","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"ref_4","unstructured":"Van Heerden, P.J. (1945). The crystal counter. [Dissertation, Utrecht University]."},{"key":"ref_5","first-page":"1","article-title":"11th International Workshop on Room Temperature Semiconductors and Associated Electronics","volume":"458","author":"James","year":"2001","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"ref_6","first-page":"3585","article-title":"15th International Workshop on Room-Temperature Semiconductor X- and Gamma-Ray Detectors","volume":"6","author":"Phlips","year":"2006","journal-title":"IEEE Nucl. Sci. Symp.Conf. Rec."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"1997","DOI":"10.1118\/1.597899","article-title":"Comparison of x-ray cross sections for diagnostic and therapeutic medical physics","volume":"23","author":"Boone","year":"1996","journal-title":"Med. Phys."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1063\/1.1710367","article-title":"Currents to conductors induced by a moving point charge","volume":"9","author":"Shockley","year":"1938","journal-title":"J. Appl. Phys"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"584","DOI":"10.1109\/JRPROC.1939.228757","article-title":"Currents induced by electron motion","volume":"27","author":"Ramo","year":"1939","journal-title":"Proc. IRE"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1016\/0029-554X(71)90235-7","article-title":"Extension of Ramo theorem as applied to induced charge in semiconductor detectors","volume":"92","author":"Cavalleri","year":"1971","journal-title":"Nucl. Instrum. Methods"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1016\/S0168-9002(01)00223-6","article-title":"Review of the Shockley-Ramo theorem and its application in semiconductor gamma ray detectors","volume":"463","author":"He","year":"2001","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"ref_12","unstructured":"Jackson, J.D. (1999). Classical Electrodynamics, Wiley. [2rd Ed.]."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1007\/BF01338917","article-title":"Zum Mechanismus des lichtelektrischen Prim\u00e4rstromes in isolierenden Kristallen","volume":"77","author":"Hecht","year":"1932","journal-title":"Z. Phys."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1016\/j.nima.2006.05.085","article-title":"Signal variance in gamma-ray detectors \u2014 A review","volume":"565","author":"Devanathan","year":"2006","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1016\/j.nima.2005.03.026","article-title":"Resolution degradation of semiconductor detectors due to carrier trapping","volume":"546","author":"Kozorezov","year":"2005","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1016\/0029-554X(67)90147-4","article-title":"CdTe as a gamma detector","volume":"55","author":"Akutagawa","year":"1967","journal-title":"Nucl. Instrum. Methods"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1016\/S0080-8784(08)62745-3","article-title":"Growth methods of CdTe nuclear detector materials","volume":"43","author":"Schlesinger","year":"1995","journal-title":"Semiconductors for Room Temperature Nuclear Detector applications"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1109\/TNS.1974.4327478","article-title":"Polarization phenomena in CdTe nuclear detectors","volume":"21","author":"Malm","year":"1974","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/S0168-9002(02)01175-0","article-title":"Stability issues of high-energy resolution diode type CdTe nuclear radiation detectors in a long-term operation","volume":"491","author":"Niraula","year":"2002","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S0168-9002(00)00923-2","article-title":"On hydrogen transport VPE-grown CdTe epilayers for fabrication of 1-100 keV X-ray detectors","volume":"458","author":"Lovergine","year":"2001","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"ref_21","unstructured":"Lovergine, N., Marzo, F., Mancini, A.M, and Prete, P. (2004, January May). Development of a CdTe-CZT epitaxial technology for fabrication of large area RT 1-100 keV X-ray photon detectors. Como, Italy."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1018","DOI":"10.1002\/crat.200410478","article-title":"Hydrogen transport vapour growth and properties of thick CdTe epilayers for RT X-ray detector applications","volume":"40","author":"Lovergine","year":"2005","journal-title":"Crystal Res. Technol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1016\/0022-0248(90)90769-H","article-title":"A comparison of the structure of CdTe and (Hg, Cd)Te layers grown by MOVPE on {111}A and {111}B CdTe substrates","volume":"86","author":"Hails","year":"1990","journal-title":"J. Cryst. Growth"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"6472","DOI":"10.1063\/1.348853","article-title":"Growth of CdTe(111)B homoepitaxial layers by hot-wall epitaxy","volume":"69","author":"Tatsuoka","year":"1991","journal-title":"J. Appl. Phys."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1002\/1521-3951(200201)229:1<83::AID-PSSB83>3.0.CO;2-4","article-title":"Low-temperature growth and doping of CdTe epilayers on CdTe substrates in a remote-plasma-assisted MOCVD system for nuclear radiation detector applications","volume":"229","author":"Niraula","year":"2002","journal-title":"Phys. Stat. Solidi (B)"},{"key":"ref_26","first-page":"754","article-title":"MOVPE growth optimisation of CdTe epitaxial layers for p-i-n diode X-ray detector fabrication","volume":"3","author":"Traversa","year":"2006","journal-title":"Phys. Stat. Solidi"},{"key":"ref_27","first-page":"244","article-title":"Development of a homoepitaxial technology for fabrication of X-and \u03b3 -ray detectors based on CdTe p-i-n diodes","volume":"166C","author":"Lovergine","year":"2007","journal-title":"Nuclear Phys. B (Proc. Suppl.)"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1007\/s00339-007-4382-1","article-title":"Substrate treatment and precursor stoichiometry effects on the homoepitaxy of CdTe grown by MOVPE on detector-grade (111)B-CdTe crystals","volume":"91","author":"Traversa","year":"2008","journal-title":"Appl. Phys. A"},{"key":"ref_29","unstructured":"Traversa, M., Prete, P., Farella, I., Paiano, P., Marzo, F., Cola, A., Lovergine, N., and Mancini, A.M. A MOVPE technology for fabrication of CdTe-based homoepitaxial p-i-n diode structures as nuclear radiation detectors."},{"key":"ref_30","unstructured":"Farella, I., Cola, A., Lovergine, N., and Mancini, A.M. unpublished data."},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Farella, I., Montagna, G., Mancini, A.M., and Cola, A. (2008). Study on instability phenomena in CdTe diode-like detectors. IEEE Nucl. Sci. Symp. Conf. Rec., 154\u2013161.","DOI":"10.1109\/NSSMIC.2008.4775144"},{"key":"ref_32","unstructured":"Schlesinger, T.E., and James, R.B. (1995). Cd1-xZnxTe spectrometers for gamma and x-ray applications, Accademic Press."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1016\/S0927-796X(01)00027-4","article-title":"Cadmium zinc telluride and its use as a nuclear radiation material","volume":"32","author":"Schlesinger","year":"2001","journal-title":"Mater. Sci. Eng. R"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"1418","DOI":"10.1116\/1.586264","article-title":"Properties of CdZnTe crystals grown by a high pressure Bridgman method","volume":"10","author":"Doty","year":"1992","journal-title":"J. Vac. Sci. Technol. B"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"576","DOI":"10.1016\/S0022-0248(07)80003-0","article-title":"Vertical Bridgman growth and characterization of large-diameter single-crystal CdTe","volume":"128","author":"Casagrande","year":"1993","journal-title":"J. Cryst. Growth"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/0022-0248(90)90708-S","article-title":"High quality single crystal CdTe grown by a modified horizontal Bridgman technique","volume":"86","author":"Lay","year":"1988","journal-title":"J. Cryst. Growth"},{"key":"ref_37","first-page":"56","article-title":"Detached solidification","volume":"VIII","author":"Wilcox","year":"1995","journal-title":"Microgravity Sci. Technol."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/S0022-0248(98)00421-7","article-title":"Bridgman solidification of GaSb in space","volume":"192","author":"Duffar","year":"1998","journal-title":"J. Cryst. Growth"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.jcrysgro.2004.12.163","article-title":"Detached growth behavior of 2-in germanium crystals","volume":"277","author":"Jenkner","year":"2005","journal-title":"J. Cryst. Growth"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1016\/j.jcrysgro.2004.04.023","article-title":"Dewetted growth and characterisation of high-resistivity CdTe","volume":"267","author":"Fiederle","year":"2004","journal-title":"J. Cryst. Growth"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"782","DOI":"10.1109\/TNS.2007.902361","article-title":"Boron Oxide Encapsulated Vertical Bridgman: A method for preventing crystal-crucible contact in the CdZnTe growth","volume":"54","author":"Zappettini","year":"2007","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1016\/j.jcrysgro.2007.07.012","article-title":"Boron oxide fully encapsulated CdZnTe crystals grown by the vertical Bridgman technique","volume":"307","author":"Zappettini","year":"2007","journal-title":"J. Cryst. Growth"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"2072","DOI":"10.1016\/j.jcrysgro.2007.11.230","article-title":"Full encapsulated CdZnTe crystals by the vertical Bridgman method","volume":"310","author":"Zha","year":"2008","journal-title":"J. Cryst. Growth"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"1720","DOI":"10.1016\/S0022-0248(01)02316-8","article-title":"Heat treatment in semi-closed ampoule for obtaining stoichiometrically controlled cadmium telluride","volume":"237-239","author":"Zha","year":"2002","journal-title":"J. Cryst. Growth"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"574","DOI":"10.1063\/1.90871","article-title":"Observation of dislocations in cadmium telluride by cathode luminescence microscopy","volume":"34","author":"Nakagawa","year":"1979","journal-title":"Appl. Phys. Letters"},{"key":"ref_46","first-page":"276","article-title":"Fundamental studies on Bridgman growth of CdTe","volume":"29","author":"Rudolph","year":"1995","journal-title":"Prog. Crystal Growth"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/0022-0248(90)90707-R","article-title":"Crystal growth of large-area single-crystal CdTe and CdZnTe by the computer-controlled vertical modified-Bridgman process","volume":"86","author":"Sen","year":"1990","journal-title":"J. Cryst. Growth"},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"Auricchio, N., Marchini, L., Caroli, E., Donati, A., Zappettini, A., Zanichelli, M., and Quadrini, M. (2008). Spectroscopic response of CZT detectors obtained by the boron encapsulated vertical Bridgman method. IEEE Nucl. Sci. Symp. Conf. Rec., 250\u2013253.","DOI":"10.1109\/NSSMIC.2008.4775161"},{"key":"ref_49","doi-asserted-by":"crossref","unstructured":"Zappettini, A., Zha, M.Z., Marchini, L., Calestani, D., Mosca, R., Gombia, E., Zanotti, L., Zanichelli, M., Pavesi, M., Auricchio, N., and Caroli, E. (2008). Boron oxide encapsulated vertical Bridgman grown CdZnTe crystals as X-ray detector material. IEEE Nucl. Sci. Symp. Conf. Rec., 118\u2013121.","DOI":"10.1109\/NSSMIC.2008.4775136"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1109\/23.790691","article-title":"Investigation of response behavior in CdTe detectors versus inter-electrode charge formation position","volume":"46","author":"Auricchio","year":"1999","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1016\/S0168-9002(96)00357-9","article-title":"Compact circuit for pulse rise-time discrimination","volume":"380","author":"Jordanov","year":"1996","journal-title":"Nucl. Instrum. Meth. Phys. Res. A"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/0168-9002(92)91227-Z","article-title":"High resolution gamma ray spectroscopy with CdTe detector systems","volume":"322","author":"Richter","year":"1992","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"1982","DOI":"10.1109\/TNS.2005.856884","article-title":"Twin shaping filter techniques to compensate the signals from CZT\/CdTe detectors","volume":"52","author":"Auricchio","year":"2005","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"ref_54","first-page":"192","article-title":"Single charge carrier type sensing with a parallel strip pseudo-frisch-grid CdZnTe semiconductor radiation detector","volume":"12","author":"McGregor","year":"1998","journal-title":"Appl. Phys.Lett."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1109\/TNS.2006.871509","article-title":"Performance characteristics of frisch-ring CdZnTe detectors","volume":"53","author":"Bolotnikov","year":"2006","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1103\/PhysRevLett.75.156","article-title":"Charge transport in arrays of semiconductor gamma-rays detectors","volume":"75","author":"Barrett","year":"1995","journal-title":"Phys. Rev. Lett."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"1975","DOI":"10.1109\/TNS.2005.856882","article-title":"Pixelated CdZnTe drift detectors","volume":"52","author":"Kuvvetli","year":"2005","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"ref_58","doi-asserted-by":"crossref","unstructured":"Abbene, L., Del Sordo, S., Agnetta, G., Biondo, B., Caroli, E., Mangano, A., Russo, F., Stephen, J.B., Ventura, G., Carlino, A., Gerardi, G., and Bertuccio, G. (2008). Investigation on pixellated CZT detectors coupled with a low power readout ASIC. IEEE Nucl. Sci. Symp. Conf. Rec., 478\u2013483.","DOI":"10.1109\/NSSMIC.2008.4775211"},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1109\/23.467848","article-title":"Unipolar charge sensing with coplanar electrodes - application to semiconductor detectors","volume":"42","author":"Luke","year":"1995","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1016\/S0168-9002(99)00005-4","article-title":"Optimum spectroscopic performance from CZT \u03b3- and X-ray detectors with pad and strip segmentation","volume":"428","author":"Shor","year":"1999","journal-title":"Nucl. Instrum. Meth. Phys. Res. A"},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1016\/j.nima.2004.05.104","article-title":"Spectroscopic response of a CdTe microstrip detector when irradiated atvarious impinging angles","volume":"531","author":"Perillo","year":"2004","journal-title":"Nucl. Instrum. Meth. Phys. Res. A"},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1109\/23.682422","article-title":"Cadmium-zinc telluride, multiple-electrode detectors achieve good energy resolution with high sensitivity at room-temperature","volume":"45","author":"Lingren","year":"1998","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"1229","DOI":"10.1109\/TNS.2004.829385","article-title":"Investigation of the energy resolution and charge collection efficiency of Cd(Zn)Te detectors with three electrodes","volume":"51","author":"Kim","year":"2004","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1016\/j.nima.2007.09.015","article-title":"Spectroscopic response of a CdZnTe multiple electrode detector","volume":"583","author":"Abbene","year":"2007","journal-title":"Nucl. Instrum. Meth. Phys. Res. A"},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/S0168-9002(98)00283-6","article-title":"CdZnTe drift detector with correction for hole trapping","volume":"411","year":"1998","journal-title":"Nucl. Instrum. Meth. Phys. Res. A"},{"key":"ref_66","unstructured":"Frisch, O. (1944). British Atomic Energy Report, Unpublished report No. BR-49."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1016\/j.nima.2006.10.112","article-title":"X-ray spectroscopy and dosimetry with a portable CdTe device","volume":"571","author":"Abbene","year":"2007","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"ref_68","first-page":"1","article-title":"Space Science for Europe 2015-2025","volume":"BR-247","author":"Vision","year":"2005","journal-title":"ESA Brochure"},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"L131","DOI":"10.1051\/0004-6361:20031224","article-title":"IBIS: The imager on-board INTEGRAL","volume":"411","author":"Ubertini","year":"2003","journal-title":"Astron. Astrophys."},{"key":"ref_70","first-page":"157","article-title":"SIMBOL-X: a formation flying mission for hard-x-ray astrophysics","volume":"5900","author":"Ferrando","year":"2005","journal-title":"Proc. SPIE"},{"key":"ref_71","unstructured":"Knodleseder, J., von Ballmoos, P., Frontiera, F., Bazzano, A., Christensen, F., Hernanz, M., and Wunderer, C.B. (2007). The GRI proposal. CV07, 1\u201344."},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"1005","DOI":"10.1086\/422091","article-title":"The Swift gamma-ray burst mission","volume":"611","author":"Gehrels","year":"2004","journal-title":"Astrophys. J."},{"key":"ref_73","first-page":"59000X1","article-title":"Taylor, M.D.NuSTAR hard x-ray optics","volume":"5900","author":"Koglin","year":"2005","journal-title":"Proc. SPIE"},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"1333","DOI":"10.1016\/j.asr.2005.06.011","article-title":"The gamma ray burst monitor for LOBSTER-ISS","volume":"38","author":"Amati","year":"2006","journal-title":"Adv. Sp. Res."},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1007\/s10686-008-9092-y","article-title":"EDGE: Explorer of diffuse emission and gamma-ray burst explosions","volume":"23","author":"Piro","year":"2009","journal-title":"Exp. Astron."},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1016\/j.nima.2007.01.124","article-title":"Performance updating of CdZnTe strip-drift detectors","volume":"576","author":"Shorohov","year":"2007","journal-title":"Nucl. Instrum. Meth. Phys. Res. A"},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"70113G","DOI":"10.1117\/12.790558","article-title":"A three-dimensional CZT detector as a focal plane prototype for a Laue Lens telescope","volume":"7011","author":"Caroli","year":"2008","journal-title":"Proc. SPIE"},{"key":"ref_78","doi-asserted-by":"crossref","first-page":"1183","DOI":"10.1126\/science.1149056","article-title":"Polarized gamma-ray emission from the crab","volume":"321","author":"Dean","year":"2008","journal-title":"Science"},{"key":"ref_79","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1023\/B:EXPA.0000028172.78709.1e","article-title":"CHIPER, a polarimetric telescope concept for hard X-ray astronomy","volume":"15","author":"Caroli","year":"2003","journal-title":"Exp. Astron."},{"key":"ref_80","first-page":"1","article-title":"Polarimetric performance of a Laue lens gamma-ray CdZnTe focal plane prototipe","volume":"084903","author":"Caroli","year":"2008","journal-title":"J. Appl. Phys."},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"3091","DOI":"10.1109\/TNS.2005.862916","article-title":"Characterization of a CZT focal plane small prototype for hard X-ray telescope","volume":"52","author":"Abbene","year":"2005","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"ref_82","first-page":"257","article-title":"Spectroscopic performances of 16 \u00d7 16 pixel CZT imaging hard-X-ray detectors","volume":"119","author":"Strazzeri","year":"2004","journal-title":"Nuovo Cimento B"},{"key":"ref_83","unstructured":"Pareschi, G., Di Cocco, G., Caroli, E., Citterio, O., Cotroneo, V., Del Sordo, S., Frontera, F., Gizzi, L., Malaguti, G., Silvestri, S., and Spiga, D. (2003, January June). The HEXIT (high energy X-ray imaging telescope) balloon-borne mission. Sankt Gallen, Switzerland."},{"key":"ref_84","unstructured":"Willardson, R.K., Weber, E.R., and Beer, A.C. (1995). Semiconductors for Room Temperature Nuclear Detector Applications. In Semiconductors and Semimetals, Accademic Press."},{"key":"ref_85","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1016\/S0168-9002(99)00003-0","article-title":"CdTe and CdZnTe gamma ray detectors for medical and industrial imaging systems","volume":"428","author":"Eisen","year":"1999","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"ref_86","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/S0168-9002(00)01032-9","article-title":"Medical applications of CdTe and CdZnTe detectors","volume":"458","author":"Scheiber","year":"2001","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"ref_87","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1063\/1.1715998","article-title":"Scintillation Camera","volume":"29","author":"Anger","year":"1958","journal-title":"Rev. Sci. Instrum."},{"key":"ref_88","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1109\/23.682408","article-title":"CdZnTe solid-state gamma camera","volume":"45","author":"Butler","year":"1998","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"ref_89","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1016\/S0168-9002(99)00605-1","article-title":"Applications of semiconductor detectors to nuclear medicine","volume":"436","author":"Barber","year":"1999","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"ref_90","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1016\/S0168-9002(00)00282-5","article-title":"CdTe and CdZnTe detectors in nuclear medicine","volume":"448","author":"Scheiber","year":"2000","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"ref_91","doi-asserted-by":"crossref","first-page":"474","DOI":"10.1016\/S0168-9002(96)00364-6","article-title":"A gamma camera based on CdTe detectors","volume":"380","author":"Eisen","year":"1996","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"ref_92","doi-asserted-by":"crossref","first-page":"1728","DOI":"10.1109\/TNS.2002.801532","article-title":"NUCAM3 \u2014 a gamma camera based on segmented monolithic CdZnTe detectors","volume":"49","author":"Eisen","year":"2002","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"ref_93","doi-asserted-by":"crossref","first-page":"3111","DOI":"10.1109\/TNS.2004.839070","article-title":"Performance and perspectives of a CdZnTe-based gamma camera for medical imaging","volume":"51","author":"Verger","year":"2004","journal-title":"IEEE Trans. Nucl. Sci"},{"key":"ref_94","doi-asserted-by":"crossref","first-page":"1573","DOI":"10.1109\/TNS.2008.924069","article-title":"A new architecture for pixellated solid state gamma camera used in nuclear medicine","volume":"55","author":"Verger","year":"2008","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"ref_95","doi-asserted-by":"crossref","unstructured":"Zhang, F., He, Z., Xu, D., and Meng, L.J. (2005). Feasibility study of using two 3-D position sensitive CZT detectors for small animal PET. IEEE Nucl. Sci. Symp. Conf. Rec., 1582\u20131585.","DOI":"10.1109\/NSSMIC.2005.1596621"},{"key":"ref_96","doi-asserted-by":"crossref","unstructured":"Vaska, P., Dragone, A., Lee, W., Kim, D.H., Pratte, J.F., Cui, Y.G., Fried, J., Krishnamoorthy, S., Bolotnikov, A., Park, S.J., O'Connor, P., Dilmanian, F.A., and James, R.B. (2007). A Prototype CZT-Based PET Scanner for High Resolution Mouse Brain Imaging. IEEE Nucl. Sci. Symp. Conf. Rec., 3816\u20133819.","DOI":"10.1109\/NSSMIC.2007.4436952"},{"key":"ref_97","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.nima.2006.10.023","article-title":"New trends in \u03b3-ray imaging with CdZnTe\/CdTe at CEA-Leti","volume":"571","author":"Verger","year":"2007","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"ref_98","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1016\/j.nima.2006.10.292","article-title":"CdZnTe detectors for small field of view positron emission tomographic imaging","volume":"571","author":"Drezet","year":"2007","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"ref_99","doi-asserted-by":"crossref","first-page":"R287","DOI":"10.1088\/0031-9155\/53\/17\/R01","article-title":"Recent developments in PET detector technology","volume":"53","author":"Lewellen","year":"2008","journal-title":"Phys. Med. Biol."},{"key":"ref_100","doi-asserted-by":"crossref","first-page":"1421","DOI":"10.1118\/1.1485975","article-title":"CdZnTe detector in diagnostic x-ray spectroscopy","volume":"29","author":"Miyajima","year":"2002","journal-title":"Med. Phys."},{"key":"ref_101","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1118\/1.1566388","article-title":"Thin CdTe detector in diagnostic x-ray spectroscopy","volume":"30","author":"Miyajima","year":"2003","journal-title":"Med. Phys."},{"key":"ref_102","doi-asserted-by":"crossref","first-page":"3469","DOI":"10.1118\/1.2229431","article-title":"Comparison of two portable solid state detectors with an improved collimation and alignment device for mammographic x-ray spectroscopy","volume":"33","author":"Bottigli","year":"2006","journal-title":"Med. Phys."},{"key":"ref_103","unstructured":"Charles, C., and Thomas, S. (1983). The Physics of Radiology, [4th Ed.]."},{"key":"ref_104","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1016\/S0168-9002(00)00805-6","article-title":"The evolution of scintillating medical detectors","volume":"454","author":"Hell","year":"2000","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"ref_105","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1088\/0031-9155\/24\/3\/002","article-title":"Computation of bremsstrahlung X-ray spectra and comparison with spectra measured with a Ge(Li) detector","volume":"24","author":"Birch","year":"1979","journal-title":"Phys. Med. Biol."},{"key":"ref_106","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1118\/1.596354","article-title":"Measurement of diagnostic x-ray spectra using a silicon photodiode","volume":"16","author":"Aoki","year":"1989","journal-title":"Med. Phys."},{"key":"ref_107","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1016\/j.nima.2006.10.113","article-title":"Digital filtering and analysis for a semiconductor X-ray detector data acquisition","volume":"571","author":"Gerardi","year":"2007","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"key":"ref_108","first-page":"254","article-title":"L'esperimento XPRESS","volume":"1","author":"Abbene","year":"2005","journal-title":"Atti IV Congr. Naz. AIFM"}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/9\/5\/3491\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T22:10:22Z","timestamp":1760220622000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/9\/5\/3491"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,5,12]]},"references-count":108,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2009,5]]}},"alternative-id":["s90503491"],"URL":"https:\/\/doi.org\/10.3390\/s90503491","relation":{},"ISSN":["1424-8220"],"issn-type":[{"value":"1424-8220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,5,12]]}}}