{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,16]],"date-time":"2025-12-16T12:13:04Z","timestamp":1765887184090,"version":"build-2065373602"},"reference-count":36,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2009,11,17]],"date-time":"2009-11-17T00:00:00Z","timestamp":1258416000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Sensors"],"abstract":"<jats:p>The results of recent research on our implantable CMOS biomedical devices are reviewed. Topics include retinal prosthesis devices and deep-brain implantation devices for small animals. Fundamental device structures and characteristics as well as in vivo experiments are presented.<\/jats:p>","DOI":"10.3390\/s91109073","type":"journal-article","created":{"date-parts":[[2009,11,17]],"date-time":"2009-11-17T11:32:03Z","timestamp":1258457523000},"page":"9073-9093","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":79,"title":["Implantable CMOS Biomedical Devices"],"prefix":"10.3390","volume":"9","author":[{"given":"Jun","family":"Ohta","sequence":"first","affiliation":[{"name":"Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma, Nara 630-0101, Japan"},{"name":"CREST, Japan Science and Technology Agency, 3-5 Sanban, Chiyoda, Tokyo 102-0075, Japan"}]},{"given":"Takashi","family":"Tokuda","sequence":"additional","affiliation":[{"name":"Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma, Nara 630-0101, Japan"},{"name":"CREST, Japan Science and Technology Agency, 3-5 Sanban, Chiyoda, Tokyo 102-0075, Japan"}]},{"given":"Kiyotaka","family":"Sasagawa","sequence":"additional","affiliation":[{"name":"Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma, Nara 630-0101, Japan"},{"name":"CREST, Japan Science and Technology Agency, 3-5 Sanban, Chiyoda, Tokyo 102-0075, Japan"}]},{"given":"Toshihiko","family":"Noda","sequence":"additional","affiliation":[{"name":"Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma, Nara 630-0101, Japan"},{"name":"CREST, Japan Science and Technology Agency, 3-5 Sanban, Chiyoda, Tokyo 102-0075, Japan"}]}],"member":"1968","published-online":{"date-parts":[[2009,11,17]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.sna.2005.03.065","article-title":"Flexible and extendible neural interface device based on cooperative multi-chip CMOS LSI architecture","volume":"122","author":"Tokuda","year":"2005","journal-title":"Sens. Actuat. A"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1109\/MEMB.2006.1705747","article-title":"Silicon LSI-Based Smart Stimulators for Retinal Prosthesis","volume":"25","author":"Ohta","year":"2006","journal-title":"IEEE Eng. Med. Biol. Mag."},{"key":"ref_3","first-page":"487","article-title":"Pulse frequency modulation based CMOS image sensor for subretinal stimulation","volume":"53","author":"Ng","year":"2006","journal-title":"IEEE Trans. Circ. Syst. II"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"S85","DOI":"10.1088\/1741-2560\/4\/1\/S10","article-title":"Laboratory investigation of microelectronics-based stimulators for large-scale suprachroidal transretinal stimulation (STS)","volume":"4","author":"Ohta","year":"2007","journal-title":"J. Neural Eng."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"3220","DOI":"10.1143\/JJAP.47.3220","article-title":"Retinal stimulation on rabbit using CMOS-based multi-chip flexible stimulator toward retinal prosthesis","volume":"47","author":"Tokuda","year":"2008","journal-title":"Jpn. J. Appl. Phys."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"2006","DOI":"10.1016\/j.jneumeth.2006.02.005","article-title":"Real time in vivo imaging and measurement of serine protease activity in the mouse hippocampus using a dedicated CMOS imaging device","volume":"156","author":"Ng","year":"2006","journal-title":"J. Neurosci. Meth."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1016\/j.sna.2007.11.020","article-title":"An implantable and fully-integrated complementary metal-oxide semiconductor device for in vivo neural imaging and electrical interfacing with the mouse hippocampus","volume":"145-146","author":"Ng","year":"2008","journal-title":"Sens. Actuat. A"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1109\/JSEN.2007.912921","article-title":"Integrated in vivo neural imaging and interface CMOS devices: design; packaging; and implementation","volume":"8","author":"Ng","year":"2008","journal-title":"IEEE Sens. J."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/j.jneumeth.2008.06.002","article-title":"One-chip sensing device (Biomedical photonic LSI) enabled to assess hippocampal steep and gradual up-regulated proteolytic activities","volume":"173","author":"Tamura","year":"2008","journal-title":"J. Neurosci. Meth."},{"key":"ref_10","unstructured":"Roham, M., Garris, P., and Mohseni, P. A wireless multichannel IC for time-share chemical and electrical neural recording. San Francisco, CA, USA."},{"key":"ref_11","unstructured":"Agnew, W.F., McCreery, D.B., Yuen, T.G.H., and Bullara, L.A. (1990). Neural Prostheses, Prentice Hall."},{"key":"ref_12","unstructured":"Robblee, L.S., and Rose, T.L. (1990). Neural Prostheses, Prentice Hall."},{"key":"ref_13","unstructured":"McCreery, D.B., and Agnew, W.F. (1990). Neural Prostheses, Prentice Hall."},{"key":"ref_14","unstructured":"Wandell, B.A. (1995). Foundations of Vision, Sinauer Associates Inc."},{"key":"ref_15","unstructured":"(2005). Research Report by Ministry of Health, Labour, and Welfare of Japan."},{"key":"ref_16","first-page":"40","article-title":"Preservation of the inner retina in retinitis pigmentosa; a morphometric analysis","volume":"114","author":"Santos","year":"1996","journal-title":"Arch. Ophthalmol."},{"key":"ref_17","first-page":"143","article-title":"Morphometric analysis of the extramacular retina from postmorten eyes with retinitis pigmentosa","volume":"40","author":"Humayun","year":"1999","journal-title":"Invest. Ophthalmol Vis. Sci."},{"key":"ref_18","unstructured":"Liu, W., and Humayun, M.S. (2004). IEEE Int. Solid-State Cric. Conf.\u2014Dig. Tech. Papers."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"2573","DOI":"10.1016\/S0042-6989(03)00457-7","article-title":"Visual perception in a blind subject with a chronic microelectronic retinal prosthesis","volume":"43","author":"Humayun","year":"2003","journal-title":"Vision Res."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"5355","DOI":"10.1167\/iovs.02-0819","article-title":"Methods and perceptual thresholds for short-term electrical stimulation of human retina with microelectrode Arrays","volume":"44","author":"Rizzo","year":"2003","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"S129","DOI":"10.1088\/1741-2560\/2\/1\/014","article-title":"A method and technical equipment for an acute human trial to evaluate retinal implant technology","volume":"2","author":"Hornig","year":"2005","journal-title":"J. Neural. Eng."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1001\/archopht.122.4.460","article-title":"The artificial silicon retina microchip for the treatment of vision loss from retinitis pigmentosa","volume":"122","author":"Chow","year":"2004","journal-title":"Arch. Ophthalmol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1022","DOI":"10.1126\/science.1067996","article-title":"Will retinal implants restore vision?","volume":"295","author":"Zrenner","year":"2002","journal-title":"Science"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1007\/s00417-004-1049-x","article-title":"Subretinal implantation and testing of polyimide film electrodes in cats","volume":"243","author":"Sachs","year":"2005","journal-title":"Graefe's Arch. Clin. Exp. Ophthalmol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1167\/iovs.02-1268","article-title":"Electrophysiological studies of the feasibility of suprachoroidal-transretinal stimulation for artificial vision in normal and RCS rats","volume":"45","author":"Kanda","year":"2004","journal-title":"Invest. Ophthal. Vis. Sci."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1007\/s00417-004-1060-2","article-title":"Transretinal electrical stimulation by an intrascleral multichannel electrode array in rabbit eyes","volume":"243","author":"Nakauchi","year":"2005","journal-title":"Graefe's Arch. Clin. Exp. Ophthalmol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"996","DOI":"10.1046\/j.1525-1594.2003.07305.x","article-title":"Pattern recognition with the optica nerve visual prosthesis","volume":"11","author":"Veraart","year":"2003","journal-title":"Artif. Organs"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1097\/00002480-200001000-00002","article-title":"Artificial vision for the blind by connecting a television camera to the visual cortex","volume":"46","author":"Dobelle","year":"2000","journal-title":"ASAIO J."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1109\/10.8670","article-title":"A spiral nerve cuff electrode for peripheral nerve stimulation","volume":"35","author":"Naples","year":"1998","journal-title":"IEEE Trans. Biomedical Eng."},{"key":"ref_30","unstructured":"Kenneth, W.H., and Dhilon, G.S. (2004). Neuroprothetics, World Scientific Publishing Co. Pte. Ltd."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1146\/annurev.bioeng.7.060804.100435","article-title":"Retinal prosthesis","volume":"7","author":"Weiland","year":"2005","journal-title":"Annu. Rev. Biomed. Eng."},{"key":"ref_32","unstructured":"Toga, A.W., and Mazziota, J.C. (2002). Brain Mapping the Methods, Academic Press. [2nd ed.]."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"903","DOI":"10.1016\/S0896-6273(01)00421-4","article-title":"A miniature head-mounted neurotechnique two-photon microscope: high resolution brain imaging in freely moving animals","volume":"31","author":"Helmchen","year":"2001","journal-title":"Neuron"},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"993","DOI":"10.1109\/5.939806","article-title":"Brain-implantable biomimetic electronics as the next era in neuralprosthetics","volume":"89","author":"Berger","year":"2001","journal-title":"Proc. IEEE"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1016\/j.snb.2005.12.020","article-title":"On-chip biofluorescence imaging inside a brain tissue phantom using a CMOS image sensor for in vivo brain imaging verification","volume":"119","author":"Ng","year":"2006","journal-title":"Sens. Actuat. B"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"04C195-1","DOI":"10.1143\/JJAP.48.04C195","article-title":"Development of complementary metal oxide semiconductor imaging devices for detecting green fluorescent protein in the deep brain of a freely moving mouse","volume":"48","author":"Tagawa","year":"2009","journal-title":"Jpn. J. Appl. Phys."}],"container-title":["Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/1424-8220\/9\/11\/9073\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T22:11:40Z","timestamp":1760220700000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/1424-8220\/9\/11\/9073"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,11,17]]},"references-count":36,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2009,11]]}},"alternative-id":["s91109073"],"URL":"https:\/\/doi.org\/10.3390\/s91109073","relation":{},"ISSN":["1424-8220"],"issn-type":[{"type":"electronic","value":"1424-8220"}],"subject":[],"published":{"date-parts":[[2009,11,17]]}}}