{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T00:37:50Z","timestamp":1790383070143,"version":"4.1.0"},"reference-count":30,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2022,6,15]],"date-time":"2022-06-15T00:00:00Z","timestamp":1655251200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Science and Technology Department of Henan Province","award":["212102210017"],"award-info":[{"award-number":["212102210017"]}]},{"name":"Science and Technology Department of Henan Province","award":["222102220116"],"award-info":[{"award-number":["222102220116"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Symmetry"],"abstract":"<jats:p>Partial discharge (PD) localization in an air-insulated substation (AIS) can be used to assess insulation conditions efficiently. Many localization methods have been reported during the past few years. However, the error of the localization results has been large or the localization algorithm too inefficient. The reason is that the localization equation set is nonlinear and non-symmetrical. In this paper, an improved particle swarm optimization (PSO) algorithm is proposed to improve the localization accuracy in 3D. Firstly, the proposed localization method is based on the symmetrical antenna array and the location error distribution is analyzed. Secondly, the objective function of PSO is constructed using the error distribution. Specifically, the 3D location target is divided into two steps\u2014plane coordinates and height. The two targets are optimized respectively. To verify the method, a test is carried out by a prefabricated fault bushing in the laboratory to compare with the existing methods. According to the results, the localization error is 0.21 m, which can locate the PD source accurately. A complete calculation takes 42.29 s, and the efficiency is increased by 16.13 times under the same accuracy. The comparison results show that the proposed method can greatly improve the efficiency while ensuring accuracy.<\/jats:p>","DOI":"10.3390\/sym14061241","type":"journal-article","created":{"date-parts":[[2022,6,19]],"date-time":"2022-06-19T21:19:26Z","timestamp":1655673566000},"page":"1241","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["3D Localization Method of Partial Discharge in Air-Insulated Substation Based on Improved Particle Swarm Optimization Algorithm"],"prefix":"10.3390","volume":"14","author":[{"given":"Pengfei","family":"Li","sequence":"first","affiliation":[{"name":"School of Electrical and Mechanical Engineering, Pingdingshan University, Pingdingshan 467000, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xinjie","family":"Peng","sequence":"additional","affiliation":[{"name":"School of Electrical and Mechanical Engineering, Pingdingshan University, Pingdingshan 467000, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaiyang","family":"Yin","sequence":"additional","affiliation":[{"name":"School of Electrical and Mechanical Engineering, Pingdingshan University, Pingdingshan 467000, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yaxu","family":"Xue","sequence":"additional","affiliation":[{"name":"School of Electrical and Mechanical Engineering, Pingdingshan University, Pingdingshan 467000, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rongqing","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Electrical and Mechanical Engineering, Pingdingshan University, Pingdingshan 467000, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhengsen","family":"Ma","sequence":"additional","affiliation":[{"name":"School of Electrical and Mechanical Engineering, Pingdingshan University, Pingdingshan 467000, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,6,15]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1049\/hve.2019.0116","article-title":"PVC nanocomposites for cable insulation with enhanced dielectric properties, partial discharge resistance and mechanical performance","volume":"5","author":"Ahmed","year":"2020","journal-title":"High Volt."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Abdel-Gawad, N.M., El Dein, A.Z., Mansour DE, A., Ahmed, H.M., Darwish MM, F., and Lehtonen, M. (2017, January 19\u201321). Experimental measurements of partial discharge activity within LDPE\/TiO2 nanocomposites. Proceedings of the 2017 Nineteenth International Middle East Power Systems Conference (MEPCON), Cairo, Egypt.","DOI":"10.1109\/MEPCON.2017.8301273"},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Abdel-Gawad, N.M., Mansour DE, A., Darwish MM, F., El Dein, A.Z., Ahmed, H.M., and Lehtonen, M. (2018, January 1\u20135). Impact of nanoparticles functionalization on partial discharge activity within PVC\/SiO2 nanocomposites. Proceedings of the 2018 IEEE 2nd International Conference on Dielectrics (ICD), Budapest, Hungary.","DOI":"10.1109\/ICD.2018.8514756"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"2748","DOI":"10.1109\/TPWRD.2020.3026102","article-title":"Investigation of the UHF Partial Discharge Detection Characteristics of a Novel Bushing Tap Sensor for Transformers","volume":"36","author":"Cheng","year":"2020","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1571","DOI":"10.1109\/TPWRD.2020.3011455","article-title":"A Correction-iteration Method for Partial Discharge Localization in Transformer based on Acoustic Measurement","volume":"36","author":"Zhou","year":"2020","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"2548","DOI":"10.1109\/TPWRD.2020.2965804","article-title":"On Site Oscillating Lightning Impulse Test and Insulation Diagnose for Power Transformers","volume":"35","author":"Zhang","year":"2020","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"17040","DOI":"10.1109\/JSEN.2021.3080314","article-title":"A Novel Localization Method of Partial Discharge Sources in Substations Based on UHF Antenna and TSVD Regularization","volume":"21","author":"Ning","year":"2021","journal-title":"IEEE Sens. J."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1109\/TDEI.2016.005964","article-title":"Localization of multiple partial discharge sources in air-insulated substation using probability-based algorithm","volume":"24","author":"Zhu","year":"2017","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Li, Z., Luo, L., Zhou, N., Sheng, G., and Jiang, X. (2017). A Novel Partial Discharge Localization Method in Substation Based on a Wireless UHF Sensor Array. Sensors, 17.","DOI":"10.3390\/s17081909"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"3649","DOI":"10.1109\/TPWRD.2020.3046276","article-title":"A UHF Sensor Based Partial Discharge Monitoring System for Air Insulated Electrical Substations","volume":"36","author":"Dhara","year":"2020","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1960","DOI":"10.1109\/TPWRD.2013.2262315","article-title":"Robust Time Delay Estimation Method for Locating UHF Signals of Partial Discharge in Substation","volume":"28","author":"Hou","year":"2013","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1891","DOI":"10.1109\/TDEI.2012.6396945","article-title":"Partial discharge localization in transformers using UHF detection method","volume":"19","author":"Sinaga","year":"2012","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1109\/94.486773","article-title":"The excitation of UHF signals by partial discharges in GIS","volume":"3","author":"Judd","year":"1996","journal-title":"IEEE Trans. Dielectr. Electr. Insul."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1109\/TPWRD.2008.2005464","article-title":"RF-Based Partial Discharge Early Warning System for Air-Insulated Substations","volume":"24","author":"Portugues","year":"2009","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_15","first-page":"104","article-title":"Error analysis and antenna array placement optimization of localization system for partial discharge in substation","volume":"90","author":"He","year":"2014","journal-title":"Prz. Elektrotechniczny"},{"key":"ref_16","first-page":"1476","article-title":"Partial Discharge Localization Method by Multi-direction Measurement Using Directional Antenna in Substation","volume":"43","author":"Wenjun","year":"2017","journal-title":"Gaodianya Jishu\/High Volt. Eng."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"1947","DOI":"10.1109\/JSEN.2020.3019760","article-title":"Application of Time Difference of Arrival Methods in the Localization of Partial Discharge Sources Detected Using Bio-Inspired UHF Sensors","volume":"21","author":"Xavier","year":"2020","journal-title":"IEEE Sens. J."},{"key":"ref_18","first-page":"822","article-title":"Partial Discharge Localization in Substations Using a Regularization Method","volume":"6","author":"Wang","year":"2020","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_19","first-page":"53","article-title":"Localization of Partial Discharge Signals Based on Ultra-high-frequency Antenna Array and Analysis of Influence Factors","volume":"55","author":"Zhu","year":"2019","journal-title":"High Volt. Appar."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Khan, U.F., Lazaridis, P.I., Mohamed, H., Albarrac\u00edn, R., Zaharis, Z.D., Atkinson, R.C., Tachtatzis, C., and Glover, I.A. (2018). An Efficient Algorithm for Partial Discharge Localization in High-Voltage Systems Using Received Signal Strength. Sensors, 18.","DOI":"10.3390\/s18114000"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"2345","DOI":"10.1049\/iet-gtd.2019.0813","article-title":"Fault Early Warning in Air-insulated Substations by RSSI-Based Angle of Arrival Estimation and Monopole UHF Wireless Sensor Array","volume":"14","author":"Zheng","year":"2020","journal-title":"IET Gener. Transm. Distrib."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1109\/TIM.2021.3126847","article-title":"A RSSI-AOA Based UHF Partial Discharge Localization Method Using MUSIC Algorithm","volume":"70","author":"Zheng","year":"2021","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"231","DOI":"10.4028\/www.scientific.net\/AMM.864.231","article-title":"Research on Location Method of PD Signal for Metal-Clad Switchgear","volume":"864","author":"Wei","year":"2017","journal-title":"Appl. Mech. Mater."},{"key":"ref_24","first-page":"1334","article-title":"Partial Discharge Location Based on Radio Frequency Antenna Array in Substation","volume":"38","author":"Hou","year":"2012","journal-title":"High Volt. Eng."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"4966","DOI":"10.1109\/JSEN.2020.3032012","article-title":"Multi-Resolution Generalized S-Transform Denoising for Precise Localization of Partial Discharge in Substations","volume":"21","author":"Wang","year":"2020","journal-title":"IEEE Sens. J."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1049\/iet-smt.2016.0251","article-title":"A Novel Method for Partial Discharge Localization in Air-insulated Substations","volume":"11","author":"Li","year":"2017","journal-title":"IET Sci. Meas. Technol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1109\/TPWRD.2014.2344014","article-title":"Localization Algorithm for the PD Source in Substation Based on L-Shaped Antenna Array Signal Processing","volume":"30","author":"Hou","year":"2015","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1881","DOI":"10.1109\/LAWP.2016.2542269","article-title":"A Novel Miniaturized Vivaldi Antenna Using Tapered Slot Edge with Resonant Cavity Structure for Ultra-wide Band Applications","volume":"15","author":"Liu","year":"2016","journal-title":"IEEE Antennas Wirel. Propag. Lett."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Li, P., Dai, K., Zhang, T., Jin, Y., Liu, Y., and Liao, Y. (2018). An accurate and efficient time delay estimation method of ultra-high frequency signals for partial discharge localization in substations. Sensors, 18.","DOI":"10.3390\/s18103439"},{"key":"ref_30","first-page":"155","article-title":"A Novel Method of Newton Iteration in Complex Field and Lattice Search for Locating Partial Discharges in Transformers","volume":"33","author":"Zheng","year":"2013","journal-title":"Proc. CSEE"}],"container-title":["Symmetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2073-8994\/14\/6\/1241\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T23:31:44Z","timestamp":1760139104000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2073-8994\/14\/6\/1241"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,15]]},"references-count":30,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2022,6]]}},"alternative-id":["sym14061241"],"URL":"https:\/\/doi.org\/10.3390\/sym14061241","relation":{},"ISSN":["2073-8994"],"issn-type":[{"value":"2073-8994","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6,15]]}}}