{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T09:52:16Z","timestamp":1762509136392,"version":"build-2065373602"},"reference-count":52,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T00:00:00Z","timestamp":1762473600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Guangdong Provincial Department of Housing and Urban Rural Development Science and Technology Innovation Plan Project","award":["2021-K35-301789","2023-K47-255536"],"award-info":[{"award-number":["2021-K35-301789","2023-K47-255536"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Symmetry"],"abstract":"<jats:p>With advantages in efficiency and sustainability, assembly splicing technology promotes construction industry upgrading. However, research on the seismic response of assembly splicing subway stations (ASS) is particularly scarce. This work studies the asymmetric ASS in soft soil, establishing a refined finite element model with soil\u2013structure interactions. Three seismic records with different frequency characteristics are applied for nonlinear incremental dynamic analysis. Based on the seismic records that produce the most unfavorable seismic response, this research is conducted on the damage distribution characteristics and the mechanical responses. In addition, the influence of the splicing response at different locations on the interlayer displacement and internal forces of structures is systematically studied. The results indicate that when seismic records with low-frequency characteristics are inputted, the ASS structure in soft soil develops into the most unfavorable state. Under strong seismic action, the top joint of the sidewall exhibits significant horizontal sliding and opening, making key areas of weak seismic performance. It also indicates that the interface contact between precast and cast-in-place components is the primary factor that is causing internal force redistribution. This study provides a reference for performance-based seismic design of ASS in soft soil.<\/jats:p>","DOI":"10.3390\/sym17111902","type":"journal-article","created":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T09:14:45Z","timestamp":1762506885000},"page":"1902","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Seismic Response Analysis of Asymmetrical Rectangular Assembly Splicing Subway Station in Soft Soil"],"prefix":"10.3390","volume":"17","author":[{"given":"Kai","family":"Wang","sequence":"first","affiliation":[{"name":"Engineering Department, Sinohydro Bureau 7 Co., Ltd., Chengdu 610000, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tongwei","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Science and Technology Innovation, Dongguan Institute of Building Research Co., Ltd., Dongguan 523820, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xun","family":"Cheng","sequence":"additional","affiliation":[{"name":"Engineering Department, Sinohydro Bureau 7 Co., Ltd., Chengdu 610000, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaolin","family":"Zhu","sequence":"additional","affiliation":[{"name":"Engineering Department, Sinohydro Bureau 7 Co., Ltd., Chengdu 610000, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shudong","family":"Zhou","sequence":"additional","affiliation":[{"name":"Department of Science and Technology Innovation, Dongguan Institute of Building Research Co., Ltd., Dongguan 523820, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-7374-1846","authenticated-orcid":false,"given":"Tao","family":"Du","sequence":"additional","affiliation":[{"name":"Department of Science and Technology Innovation, Dongguan Institute of Building Research Co., Ltd., Dongguan 523820, China"},{"name":"School of Civil Engineering, Beijing Jiaotong University, Beijing 100044, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2025,11,7]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/j.conbuildmat.2015.08.145","article-title":"Comparing carbon emissions of precast and cast-in-situ construction methods\u2014A case study of high-rise private building","volume":"99","author":"Dong","year":"2015","journal-title":"Constr. Build. Mater."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"106065","DOI":"10.1016\/j.compgeo.2024.106065","article-title":"Seismic performance and vulnerability analysis for bifurcated tunnels in soft soil","volume":"167","author":"Jiang","year":"2024","journal-title":"Comput. Geotech."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Cheng, X.L., Li, Q.Q., Hai, R., Guo, S.S., and Xing, X.F. (2024). Research progress and prospects of seismic performance on underground structure embedded in soft soil foundation. Sci. Rep., 14.","DOI":"10.1038\/s41598-024-73122-3"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"105202","DOI":"10.1016\/j.tust.2023.105202","article-title":"Mechanical properties analysis of joints for prefabricated metro station structure based on whole-process in-situ monitoring","volume":"138","author":"Lin","year":"2023","journal-title":"Tunn. Undergr. Space Technol."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"102994","DOI":"10.1016\/j.tust.2019.102994","article-title":"Shaking table test on seismic response characteristics of prefabricated subway station structure","volume":"91","author":"Tao","year":"2019","journal-title":"Tunn. Undergr. Space Technol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"103583","DOI":"10.1016\/j.tust.2020.103583","article-title":"Comparative study of the seismic performance of prefabricated and cast-in-place subway station structures by shaking table test","volume":"105","author":"Tao","year":"2020","journal-title":"Tunn. Undergr. Space Technol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/j.scs.2018.11.010","article-title":"Three-dimensional dynamic response analysis of a single-ring structure in a prefabricated subway station","volume":"45","author":"Ding","year":"2019","journal-title":"Sustain. Cities Soc."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"107218","DOI":"10.1016\/j.istruc.2024.107218","article-title":"Numerical study on seismic performance of a prefabricated subway station considering the influence of construction process","volume":"69","author":"Gao","year":"2024","journal-title":"Structures"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"70259","DOI":"10.1002\/suco.70259","article-title":"Numerical simulation on the mechanical property improvement of prefabricated subway station containing prestressed steel strand joints","volume":"146","author":"Yu","year":"2025","journal-title":"Struct. Concr."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"140825","DOI":"10.1016\/j.conbuildmat.2025.140825","article-title":"Tensile anchorage and seismic performance of U-bar connections between sidewall and bottom slabs for prefabricated subway station structures","volume":"472","author":"Feng","year":"2025","journal-title":"Constr. Build. Mater."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"142117","DOI":"10.1016\/j.conbuildmat.2025.142117","article-title":"Experimental and numerical analysis on seismic behavior of tenon-bolted column end joints in prefabricated subway stations","volume":"487","author":"Xiong","year":"2025","journal-title":"Constr. Build. Mater."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"101410","DOI":"10.1016\/j.jobe.2020.101410","article-title":"Seismic performance of precast column connected with grouted sleeve connectors","volume":"31","author":"Liu","year":"2020","journal-title":"J. Build. Eng."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"111799","DOI":"10.1016\/j.engstruct.2020.111799","article-title":"The seismic behaviour of precast concrete interior joints with different connection methods in assembled monolithic subway station","volume":"232","author":"Liu","year":"2021","journal-title":"Eng. Struct."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"763","DOI":"10.1007\/s11709-023-0917-6","article-title":"Effect of strata restraint on seismic performance of prefabricated sidewall joints in fabricated subway stations","volume":"17","author":"He","year":"2023","journal-title":"Front. Struct. Civ. Eng."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"115015","DOI":"10.1016\/j.measurement.2024.115015","article-title":"Monitoring and assessment of mechanical response of large-scale prefabricated structures in underground subway stations during construction process","volume":"235","author":"Hong","year":"2024","journal-title":"Measurement"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"108972","DOI":"10.1016\/j.jcsr.2024.108972","article-title":"Joints mechanical characteristics of prefabricated subway station considering bending stiffness difference","volume":"222","author":"Jiang","year":"2024","journal-title":"J. Constr. Steel Res."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"9958436","DOI":"10.1155\/2021\/9958436","article-title":"Experimental Analysis of bending stiffness characteristics of grouted double mortise-tenon joint for prefabricated metro station structure","volume":"2021","author":"Yang","year":"2021","journal-title":"Adv. Civ. Eng."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Mo, Z.Z., Feng, S.K., Guan, D.Z., and Guo, Z.X. (2023). Effect of entrance frame on crack development around prefabricated subway station openings. Buildings, 13.","DOI":"10.3390\/buildings13041032"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"179","DOI":"10.2749\/101686695780601079","article-title":"Effect of the southern Hyogo earthquake on the Akashi-Kaikyo bridge","volume":"5","author":"Tada","year":"1995","journal-title":"Struct. Eng. Int."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"2650321","DOI":"10.1142\/S0219455426503219","article-title":"Seismic Damage simulations in Prefabricated Reinforce Concrete Subway Stations","volume":"5","author":"Wang","year":"2025","journal-title":"Int. J. Struct. Stab. Dyn."},{"key":"ref_21","first-page":"164","article-title":"Response comparisons of precast and cast-in-place subway station structures in the high seismic intensity region","volume":"42","author":"Jiang","year":"2025","journal-title":"Eng. Mech."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"107460","DOI":"10.1016\/j.soildyn.2022.107460","article-title":"Study on seismic performance and index limits quantification for prefabricated subway station structures","volume":"162","author":"Chen","year":"2022","journal-title":"Soil Dyn. Earthq. Eng."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"4065301","DOI":"10.1155\/2019\/4065301","article-title":"Research on Shear Capacity and Checking Method of MT\u00b7G-Joint for Application in Prefabricated Underground Structures","volume":"2019","author":"Yang","year":"2019","journal-title":"Adv. Mater. Sci. Eng."},{"key":"ref_24","first-page":"235","article-title":"Study on seismice dynamic responses and damping measures of the superimposed prefabricated subway station structure","volume":"43","author":"Yu","year":"2023","journal-title":"Earthq. Eng. Eng. Dyn."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"103153","DOI":"10.1016\/j.tust.2019.103153","article-title":"Shaking table test study on the functionality of rubber isolation bearing used in underground structure subjected to earthquakes","volume":"98","author":"Zheng","year":"2020","journal-title":"Tunn. Undergr. Space Technol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"110073","DOI":"10.1016\/j.engstruct.2019.110073","article-title":"Effect of vertical ground motions and overburden depth on the seismic responses of large underground structures","volume":"205","author":"Li","year":"2020","journal-title":"Eng. Struct."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"105967","DOI":"10.1016\/j.soildyn.2019.105967","article-title":"Numerical analyses of seismic performance of underground and aboveground structures with friction pendulum bearings","volume":"130","author":"Xu","year":"2020","journal-title":"Soil Dyn. Earthq. Eng."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"106724","DOI":"10.1016\/j.soildyn.2021.106724","article-title":"Selection of optimal intensity measures for fragility assessment of circular tunnels in soft soil deposits","volume":"145","author":"Huang","year":"2021","journal-title":"Soil Dyn. Earthq. Eng."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"106560","DOI":"10.1016\/j.soildyn.2020.106560","article-title":"Seismic performance and effective isolation of a large multilayered underground subway station","volume":"142","author":"Yang","year":"2021","journal-title":"Soil Dyn. Earthq. Eng."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"110970","DOI":"10.1016\/j.engstruct.2020.110970","article-title":"Seismic response analysis of assembled monolithic subway station in the transverse direction","volume":"219","author":"Liu","year":"2020","journal-title":"Eng. Struct."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1061\/JSFEAQ.0001885","article-title":"Finite element method accuracy for wave propagation problems","volume":"99","author":"Kuhlemeyer","year":"1973","journal-title":"J. Soil Mech. Found. Div."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"7505","DOI":"10.1080\/13632469.2021.1964647","article-title":"Seismic performance evaluation of two-story and three-span subway station in different engineering sites","volume":"26","author":"Zhong","year":"2022","journal-title":"J. Earthq. Eng."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.tust.2016.11.003","article-title":"Response characteristics of rectangular tunnels in soft soil subjected to transversal ground shaking","volume":"62","author":"Tsinidis","year":"2017","journal-title":"Tunn. Undergr. Space Technol."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"100971","DOI":"10.1016\/j.trgeo.2023.100971","article-title":"Shield tunneling-induced disturbance in soft soil","volume":"40","author":"Gao","year":"2023","journal-title":"Transp. Geotech."},{"key":"ref_35","unstructured":"Bardet, J.P., Ichii, K., and Lin, C.H. (2000). EERA: A Computer Program for Equivalent-Linear Earthquake Site Response Analyses of Layered Soil Deposits, Department of Civil Engineering, University of Southern California."},{"key":"ref_36","unstructured":"Larry, L., Martinovich, S., and Braceras, C. (2010). Technical Manual for Design and Construction of Road Tunnels-Civil Elements, American Association of State Highway and Transportation Offcials."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1139\/T10-047","article-title":"Effect of depth on seismic response of circular tunnels","volume":"48","author":"Cilingir","year":"2011","journal-title":"Can. Geotech. J."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1016\/j.soildyn.2010.10.004","article-title":"A model study on the effects of input motion on the seismic behaviour of tunnels","volume":"31","author":"Cilingir","year":"2011","journal-title":"Soil Dyn. Earthq. Eng."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"107782","DOI":"10.1016\/j.soildyn.2023.107782","article-title":"Study on the effect of burial depth on seismic response and seismic intensity measure of underground structures","volume":"166","author":"Xu","year":"2023","journal-title":"Soil Dyn. Earthq. Eng."},{"key":"ref_40","unstructured":"(2021). Code for Design of Concrete Structures (Standard No. GB 50010-2010)."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1016\/0020-7683(89)90050-4","article-title":"A plastic-damage model for concrete","volume":"25","author":"Lubliner","year":"1989","journal-title":"Int. J. Solids Struct."},{"key":"ref_42","first-page":"892","article-title":"Plastic-damage model for cyclic loading of concrete structures","volume":"124","author":"Lee","year":"1998","journal-title":"J. Eng. Mech."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/j.tust.2017.04.005","article-title":"Numerical analysis on the seismic behavior of a large metro subway tunnel in liquefiable ground","volume":"66","author":"Bao","year":"2017","journal-title":"Tunn. Undergr. Space Technol."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"103067","DOI":"10.1016\/j.tust.2019.103067","article-title":"Three-dimensional analysis of effects of ground loss on static and seismic response of shafts","volume":"92","author":"Chen","year":"2019","journal-title":"Tunn. Undergr. Space Technol."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1016\/j.soildyn.2006.10.003","article-title":"Three-dimensional numerical simulation of earthquake damage to group-piles in a liquefied ground","volume":"27","author":"Uzuoka","year":"2007","journal-title":"Soil Dyn. Earthq. Eng."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"808","DOI":"10.1016\/j.engstruct.2016.11.060","article-title":"Behavior of two new moment resisting precast beam to column connections subjected to lateral loading","volume":"132","author":"Bahrami","year":"2017","journal-title":"Eng. Struct."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.engstruct.2018.07.055","article-title":"Finite element modelling approach for precast reinforced concrete beam-to-column connections under cyclic loading","volume":"174","author":"Feng","year":"2018","journal-title":"Eng. Struct."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"1522","DOI":"10.1061\/(ASCE)1090-0241(2005)131:12(1522)","article-title":"Load transfer mechanisms between underground structure and surrounding ground: Evaluation of the failure of the Daikai station","volume":"131","author":"Huo","year":"2005","journal-title":"J. Geotech. Geoenviron. Eng."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1680\/geot.1982.32.3.195","article-title":"Computation of bearing capacity factors using finite elements","volume":"32","author":"Griffiths","year":"1982","journal-title":"Geotechnique"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.1193\/071913EQS208M","article-title":"Classification of main shocks and aftershocks in theNGA-West2 database","volume":"30","author":"Wooddell","year":"2014","journal-title":"Earthq. Spectra"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"103439","DOI":"10.1016\/j.tust.2020.103439","article-title":"Seismic performance of underground subway station with sliding between column and longitudinal beam","volume":"102","author":"Zhuang","year":"2020","journal-title":"Tunn. Undergr. Space Technol."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"107479","DOI":"10.1016\/j.soildyn.2022.107479","article-title":"Seismic vulnerability analysis for shallow-buried underground frame structure considering 18 existing subway stations","volume":"162","author":"Jiang","year":"2022","journal-title":"Soil Dyn. Earthq. Eng."}],"container-title":["Symmetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2073-8994\/17\/11\/1902\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T09:34:35Z","timestamp":1762508075000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2073-8994\/17\/11\/1902"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,7]]},"references-count":52,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2025,11]]}},"alternative-id":["sym17111902"],"URL":"https:\/\/doi.org\/10.3390\/sym17111902","relation":{},"ISSN":["2073-8994"],"issn-type":[{"value":"2073-8994","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,7]]}}}