{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T09:33:36Z","timestamp":1763026416839,"version":"3.45.0"},"reference-count":31,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T00:00:00Z","timestamp":1762992000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Jiangsu Vocational Institute of Architectural Technology General Research Project","award":["JYA324-27"],"award-info":[{"award-number":["JYA324-27"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Symmetry"],"abstract":"<jats:p>DC distribution networks exhibit inherent symmetry in their balanced power distribution and modular structure, offering high operational flexibility and making them particularly suitable for the integration of distributed generation and modern loads. This symmetric framework positions DC networks as a vital component of new power systems and a key development direction for future power supply systems in industrial and mining enterprises. However, pole-to-pole short-circuit faults disrupt this symmetry, characterized by low system damping, high fault currents, and extremely rapid current rise rates, which pose serious threats to system security and necessitate ultra-fast fault clearance. To address this issue, this paper proposes a novel pilot protection scheme inspired by symmetry principles, based on the slope of the line-mode current for pole-to-pole short-circuit faults in DC distribution networks. First, an equivalent circuit of the system before converter blocking under a pole-to-pole fault is established, and an analytical expression of the fault current is derived, incorporating symmetric analysis of modal components. Subsequently, the variation trends, amplitudes, and phase characteristics of the fault current under faults occurring in different zones of the DC line are analyzed from the perspective of modal symmetry, highlighting the symmetric and asymmetric behaviors of line-mode and zero-mode currents. Furthermore, considering the distinct symmetric properties of these currents during lightning disturbances and pole-to-pole faults, the least squares method is employed to perform linear fitting on the line-mode current, thereby capturing its symmetric variation trend. A pilot protection scheme utilizing the slope of the line-mode current is then proposed, leveraging symmetry in fault discrimination. Finally, simulation models built in MATLAB\/Simulink (R2022a) are used for validation. The results demonstrate that the proposed protection method can quickly identify faults within 1.5 ms while exhibiting strong tolerance to a 20 \u03a9 transitional resistance and 50 dB signal noise, indicating good feasibility and broad applicability, with symmetry-based analysis enhancing robustness.<\/jats:p>","DOI":"10.3390\/sym17111942","type":"journal-article","created":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T09:10:45Z","timestamp":1763025045000},"page":"1942","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A Line-Mode Current Slope-Based Protection Scheme for Pole-to-Pole Short-Circuit Faults in DC Distribution Networks"],"prefix":"10.3390","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7462-2705","authenticated-orcid":false,"given":"Wei","family":"Jin","sequence":"first","affiliation":[{"name":"College of New Energy Engineering, Jiangsu Vocational Institute of Architectural Technology, Xuzhou 221116, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shiguang","family":"Feng","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering, China University of Mining and Technology, Xuzhou 221116, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuping","family":"Lu","sequence":"additional","affiliation":[{"name":"School of Electrical Engineering, Southeast University, Nanjing 210096, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2025,11,13]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Huang, X., Fan, Y., Li, W., Fei, J., and Wang, J. (2025). Research on Line Selection Method Based on Active Injection Under DC Feeder Single-Pole Grounding Fault. Energies, 18.","DOI":"10.2139\/ssrn.5334600"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"9100","DOI":"10.1109\/TPEL.2023.3264534","article-title":"A comprehensive review of multiport DC circuit breakers for MTdc grid protection","volume":"38","author":"Zhang","year":"2023","journal-title":"IEEE Trans. Power Electron."},{"key":"ref_3","first-page":"59","article-title":"A review on voltage control strategies in DC distribution network","volume":"40","author":"Wu","year":"2021","journal-title":"Electr. Power Eng. Technol."},{"key":"ref_4","first-page":"208","article-title":"Research on key technology of underground DC power supply system in coal mine","volume":"48","author":"Mu","year":"2019","journal-title":"M. E. Eng. Technol."},{"key":"ref_5","unstructured":"Wang, C.B. (2020). Research on the Protection of Flexible DC Distribution System with High-Proportion Distributed Photovoltaics. [Master\u2019s Thesis, North China Electric Power University (Beijing)]."},{"key":"ref_6","first-page":"65","article-title":"Research on protection scheme of DC microgrid integrated with fault current limiting control technology","volume":"10","author":"Lao","year":"2023","journal-title":"South. Energy Constr."},{"key":"ref_7","first-page":"42","article-title":"Line protection schemes for flexible DC distribution network based on capacitor discharge","volume":"47","author":"Zhou","year":"2019","journal-title":"Power Syst. Prot. Control"},{"key":"ref_8","first-page":"1","article-title":"Studies on DC fault protection strategies for MMC based HVDC grid","volume":"37","author":"Yao","year":"2017","journal-title":"Proc. CSEE"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Ikhide, M., Tennakoon, S., Griffiths, A., Subramanian, S., and Ha, H. (2015, January 1\u20134). Fault detection in multi-terminal modular multilevel converter (MMC) based high voltage DC (HVDC) transmission system. Proceedings of the 2015 50th International Universities Power Engineering Conference (UPEC), Stoke-on-Trent, UK.","DOI":"10.1109\/UPEC.2015.7339887"},{"key":"ref_10","first-page":"1443","article-title":"Single-terminal fault location principle for DC distribution system based on norm assessment of linear equations coefficient inverse matrix","volume":"40","author":"Xue","year":"2020","journal-title":"Proc. CSEE"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1516","DOI":"10.1109\/TPWRD.2016.2590501","article-title":"DC fault detection and location in meshed multiterminal HVDC systems based on DC reactor voltage change rate","volume":"32","author":"Li","year":"2017","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_12","first-page":"185","article-title":"Protection method based on single-terminal transient voltage for DC distribution network with current limiting reactor","volume":"45","author":"Chen","year":"2021","journal-title":"Autom. Electr. Power Syst."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"950","DOI":"10.1109\/TPWRD.2018.2882431","article-title":"DC fault detection in MTDC systems based on transient high frequency of current","volume":"34","author":"Li","year":"2019","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1483","DOI":"10.1109\/TPWRD.2016.2608986","article-title":"Transient-voltage-based protection scheme for DC line faults in the multiterminal VSC-HVDC system","volume":"32","author":"Liu","year":"2017","journal-title":"IEEE Trans. Power Deliv."},{"key":"ref_15","first-page":"5797","article-title":"Single-ended traveling wave protection for flexible DC transmission lines based on the main frequency component of the initial traveling wave","volume":"43","author":"Deng","year":"2023","journal-title":"Proc. CSEE"},{"key":"ref_16","first-page":"2386","article-title":"Single terminal traveling wave protection for flexible HVDC transmission lines based on forward wave shape information","volume":"46","author":"Chen","year":"2022","journal-title":"Power Syst. Technol."},{"key":"ref_17","first-page":"2049","article-title":"Fault location based single-ended protection strategy for overhead VSC-MTDC independent on boundary component","volume":"39","author":"Tong","year":"2019","journal-title":"Proc. CSEE"},{"key":"ref_18","first-page":"49","article-title":"Current differential protection method of line distributed capacitance current compensation in flexible DC distribution network","volume":"51","author":"Yang","year":"2023","journal-title":"J. Fuzhou Univ. (Nat. Sci. Ed.)"},{"key":"ref_19","first-page":"2720","article-title":"A novel current differential protection scheme for flexible medium voltage direct current distribution network","volume":"21","author":"Liu","year":"2021","journal-title":"Sci. Technol. Eng."},{"key":"ref_20","first-page":"178","article-title":"A review of fault location methods in HVDC transmission lines","volume":"50","author":"Lei","year":"2022","journal-title":"Power Syst. Prot. Control"},{"key":"ref_21","first-page":"167","article-title":"Single pole-to-ground fault locating method with ability against synchronization error and high fault resistance for DC distribution network","volume":"42","author":"Wu","year":"2022","journal-title":"Electr. Power Autom. Equip."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"9301","DOI":"10.1109\/TIE.2019.2891457","article-title":"Transient current waveform similarity based protection for flexible DC distribution system","volume":"66","author":"Jia","year":"2019","journal-title":"IEEE Trans. Ind. Electron."},{"key":"ref_23","first-page":"86","article-title":"Single-pole ground selection method for DC distribution networks based on zero-mode current correlation","volume":"50","author":"Zuo","year":"2022","journal-title":"Power Syst. Prot. Control"},{"key":"ref_24","first-page":"94","article-title":"Pilot protection of flexible DC line based on Jaccard similarity integration criterion","volume":"42","author":"Li","year":"2023","journal-title":"Electr. Power Eng. Technol."},{"key":"ref_25","first-page":"116","article-title":"Directional pilot protection for flexible DC distribution network based on directional characteristics of instantaneous current","volume":"43","author":"Li","year":"2019","journal-title":"Autom. Electr. Power Syst."},{"key":"ref_26","first-page":"5343","article-title":"A directional pilot protection based on phase angle of transient high-frequency impedance for flexible DC distribution grid","volume":"38","author":"Jia","year":"2018","journal-title":"Proc. CSEE"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1049\/hve.2019.0256","article-title":"Study on lightning protection scheme of multi-terminal MMC-MVDC distribution system","volume":"5","author":"Gao","year":"2020","journal-title":"High Volt."},{"key":"ref_28","first-page":"3837","article-title":"A lightning recognition method for DC line traveling-wave protection of HVDC","volume":"38","author":"Gu","year":"2018","journal-title":"Proc. CSEE"},{"key":"ref_29","first-page":"4686","article-title":"Internal pole-to-pole short-circuit fault location of bipolar HVDC grid using sudden-change current information","volume":"39","author":"Zhu","year":"2019","journal-title":"Proc. CSEE"},{"key":"ref_30","first-page":"88","article-title":"Application of current integral cosine similarity in fault location for DC distribution lines","volume":"26","author":"Hong","year":"2022","journal-title":"Electr. Mach. Control"},{"key":"ref_31","first-page":"10","article-title":"Research on applicability of current fault component polarity pilot directional protection for VSC-HVDC cable lines","volume":"41","author":"Cai","year":"2013","journal-title":"Power Syst. Prot. Control"}],"container-title":["Symmetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2073-8994\/17\/11\/1942\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T09:29:23Z","timestamp":1763026163000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2073-8994\/17\/11\/1942"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,13]]},"references-count":31,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2025,11]]}},"alternative-id":["sym17111942"],"URL":"https:\/\/doi.org\/10.3390\/sym17111942","relation":{},"ISSN":["2073-8994"],"issn-type":[{"value":"2073-8994","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,13]]}}}