{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T02:12:57Z","timestamp":1787105577645,"version":"build-2736575974"},"reference-count":38,"publisher":"MDPI AG","issue":"10","license":[{"start":{"date-parts":[[2023,5,18]],"date-time":"2023-05-18T00:00:00Z","timestamp":1684368000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000968","name":"American Heart Association","doi-asserted-by":"publisher","award":["20CDA35310687"],"award-info":[{"award-number":["20CDA35310687"]}],"id":[{"id":"10.13039\/100000968","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000968","name":"American Heart Association","doi-asserted-by":"publisher","award":["T32EB025766"],"award-info":[{"award-number":["T32EB025766"]}],"id":[{"id":"10.13039\/100000968","id-type":"DOI","asserted-by":"publisher"}]},{"name":"National Institutes of Health\u2014National Institute of Biomedical Imaging &amp; Bioengineering","award":["20CDA35310687"],"award-info":[{"award-number":["20CDA35310687"]}]},{"name":"National Institutes of Health\u2014National Institute of Biomedical Imaging &amp; Bioengineering","award":["T32EB025766"],"award-info":[{"award-number":["T32EB025766"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Applied Sciences"],"abstract":"<jats:p>The aim of this study is to investigate the applicability of the dual-venc (DV) 4D flow magnetic resonance imaging (MRI) to quantify the complex flow patterns in type B aortic dissection (TBAD). One GRAPPA-accelerated single-venc (SV) and one compressed-sensing (CS) accelerated DV 4D flow MRI sequences are used to scan all subjects, including twelve chronic TBAD patients and two volunteers. The scans are performed twice for the reproducibility assessment of the scan protocols. Voxelwise quantitative flow parameters including kinetic energy (KE), peak velocity (PV), forward and reverse flows (FF, RF) and stasis are calculated. High-venc (HV) data from the DV acquisition are separately analyzed. The scan time reduction by the CS-accelerated DV 4D flow MRI acquisition is 46.4% compared with the SV acquisition. The DV velocity-to-noise ratio (VNR) is higher compared with HV (p = 0.000). No true lumen (TL) parameter shows a significant difference among the acquisition types (p &gt; 0.05). The false lumen (FL) RF is higher in SV compared with the DV acquisition (p = 0.009). The KE is higher (p = 0.038) and stasis is lower (p = 0.01) in HV compared with SV acquisition. All FL parameters except stasis are higher and stasis is lower in HV compared with DV acquisition (p &lt; 0.05). Positive Pearson correlations among the acquisition types in TL and high agreements between the two scans for all acquisition types are observed except HV RF in the FL, which demonstrates a moderate agreement. The CS-accelerated DV 4D flow MRI may have utility in the clinical daily routine with shortened scan times and improved velocity measurements while providing high VNR in TBAD. The observed hemodynamic flow trends are similar between GRAPPA-accelerated SV and CS-accelerated DV 4D flow MRI acquisitions; however, parameters are more impacted by CS-accelerated HV protocol in FL, which may be secondary to the CS regularization effects.<\/jats:p>","DOI":"10.3390\/app13106202","type":"journal-article","created":{"date-parts":[[2023,5,19]],"date-time":"2023-05-19T00:55:29Z","timestamp":1684457729000},"page":"6202","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Aortic Hemodynamics with Accelerated Dual-Venc 4D Flow MRI in Type B Aortic Dissection"],"prefix":"10.3390","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1492-6803","authenticated-orcid":false,"given":"Ozden","family":"Kilinc","sequence":"first","affiliation":[{"name":"Department of Radiology, Northwestern University, Chicago, IL 60611, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Justin","family":"Baraboo","sequence":"additional","affiliation":[{"name":"Department of Radiology, Northwestern University, Chicago, IL 60611, USA"},{"name":"Department of Biomedical Engineering, Northwestern University, Chicago, IL 60611, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9862-9960","authenticated-orcid":false,"given":"Joshua","family":"Engel","sequence":"additional","affiliation":[{"name":"Department of Radiology, Northwestern University, Chicago, IL 60611, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Giese","sequence":"additional","affiliation":[{"name":"Magnetic Resonance, Siemens Healthcare GmbH, 91052 Erlangen, Germany"},{"name":"Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg (FAU), 91054 Erlangen, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ning","family":"Jin","sequence":"additional","affiliation":[{"name":"Cardiovascular MR R&D, Siemens Medical Solutions USA, Inc., Cleveland, OH 44139, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elizabeth K.","family":"Weiss","sequence":"additional","affiliation":[{"name":"Department of Radiology, Northwestern University, Chicago, IL 60611, USA"},{"name":"Department of Biomedical Engineering, Northwestern University, Chicago, IL 60611, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anthony","family":"Maroun","sequence":"additional","affiliation":[{"name":"Department of Radiology, Northwestern University, Chicago, IL 60611, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kelvin","family":"Chow","sequence":"additional","affiliation":[{"name":"Department of Radiology, Northwestern University, Chicago, IL 60611, USA"},{"name":"Cardiovascular MR R&D, Siemens Medical Solutions USA, Inc., Chicago, IL 60611, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoming","family":"Bi","sequence":"additional","affiliation":[{"name":"Cardiovascular MR R&D, Siemens Medical Solutions USA, Inc., Chicago, IL 60611, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rachel","family":"Davids","sequence":"additional","affiliation":[{"name":"Cardiovascular MR R&D, Siemens Medical Solutions USA, Inc., Chicago, IL 60611, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher","family":"Mehta","sequence":"additional","affiliation":[{"name":"Department of Surgery (Cardiac Surgery), Northwestern University, Chicago, IL 60611, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S. Chris","family":"Malaisrie","sequence":"additional","affiliation":[{"name":"Department of Surgery (Cardiac Surgery), Northwestern University, Chicago, IL 60611, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew","family":"Hoel","sequence":"additional","affiliation":[{"name":"Department of Surgery (Vascular Surgery), Northwestern University, Chicago, IL 60611, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James","family":"Carr","sequence":"additional","affiliation":[{"name":"Department of Radiology, Northwestern University, Chicago, IL 60611, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Markl","sequence":"additional","affiliation":[{"name":"Department of Radiology, Northwestern University, Chicago, IL 60611, USA"},{"name":"Department of Biomedical Engineering, Northwestern University, Chicago, IL 60611, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0667-137X","authenticated-orcid":false,"given":"Bradley D.","family":"Allen","sequence":"additional","affiliation":[{"name":"Department of Radiology, Northwestern University, Chicago, IL 60611, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,5,18]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"e200456","DOI":"10.1148\/ryct.2021200456","article-title":"Noninvasive Morphologic and Hemodynamic Evaluation of Type B Aortic Dissection: State of the Art and Future Perspectives","volume":"3","author":"Zilber","year":"2021","journal-title":"Radiol. Cardiothorac. Imaging"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1177\/1556984520961037","article-title":"Updates on Indications for TEVAR in Type B Aortic Dissection","volume":"15","author":"Malaisrie","year":"2020","journal-title":"Innovations"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1016\/j.jtcvs.2021.04.053","article-title":"2021 The American association for thoracic surgery expert consensus document: Surgical treatment of acute type A aortic dissection","volume":"162","author":"Malaisrie","year":"2021","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"870","DOI":"10.1136\/heartjnl-2020-316617","article-title":"Prediction of aortic dissection","volume":"106","author":"Akin","year":"2020","journal-title":"Heart"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1661","DOI":"10.1016\/j.jacc.2012.11.072","article-title":"Interdisciplinary expert consensus document on management of type B aortic dissection","volume":"61","author":"Fattori","year":"2013","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"1357","DOI":"10.1002\/jmri.26986","article-title":"Parametric Hemodynamic 4D Flow MRI Maps for the Characterization of Chronic Thoracic Descending Aortic Dissection","volume":"51","author":"Jarvis","year":"2020","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_7","first-page":"231","article-title":"Chronic type B aortic dissection: Indications and strategies for treatment","volume":"56","author":"Rohlffs","year":"2015","journal-title":"J. Cardiovasc. Surg."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/j.ccl.2017.03.004","article-title":"Acute Type A Aortic Dissection","volume":"35","author":"Elsayed","year":"2017","journal-title":"Cardiol. Clin."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.mric.2014.08.006","article-title":"4D flow MRI applications for aortic disease","volume":"23","author":"Burris","year":"2015","journal-title":"Magn. Reson. Imaging Clin. N. Am."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1016\/j.jcmg.2018.10.034","article-title":"The role of imaging of flow patterns by 4D flow MRI in aortic stenosis","volume":"12","author":"Garcia","year":"2019","journal-title":"JACC Cardiovasc. Imaging"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1002\/jmri.22083","article-title":"Clinical evaluation of aortic coarctation with 4D flow MR imaging","volume":"31","author":"Hope","year":"2010","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1186\/s12968-018-0431-5","article-title":"Differential flow improvements after valve replacements in bicuspid aortic valve disease: A cardiovascular magnetic resonance assessment","volume":"20","author":"Bissell","year":"2018","journal-title":"J. Cardiovasc. Magn. Reson."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"2174","DOI":"10.1002\/mrm.28561","article-title":"Highly accelerated aortic 4D flow MRI using compressed sensing: Performance at different acceleration factors in patients with aortic disease","volume":"85","author":"Pathrose","year":"2021","journal-title":"Magn. Reson. Med."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1186\/s12968-021-00741-4","article-title":"False lumen pressure estimation in type B aortic dissection using 4D flow cardiovascular magnetic resonance: Comparisons with aortic growth","volume":"23","author":"Marlevi","year":"2021","journal-title":"J. Cardiovasc. Magn. Reson."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"896","DOI":"10.1093\/ejcts\/ezz343","article-title":"False lumen ejection fraction predicts growth in type B aortic dissection: Preliminary results","volume":"57","author":"Burris","year":"2020","journal-title":"Eur. J. Cardiothorac. Surg."},{"key":"ref_16","first-page":"173","article-title":"4D flow imaging with MRI","volume":"4","author":"Stankovic","year":"2014","journal-title":"Cardiovasc. Diagn. Ther."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"e180009","DOI":"10.1148\/ryct.2019180009","article-title":"Detection and Hemodynamic Evaluation of Flap Fenestrations in Type B Aortic Dissection with 4D Flow MRI: Comparison with Conventional MRI and CTA","volume":"1","author":"Allen","year":"2019","journal-title":"Radiol. Cardiothorac. Imaging"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"905718","DOI":"10.3389\/fcvm.2022.905718","article-title":"Baseline 4D Flow-Derived in vivo Hemodynamic Parameters Stratify Descending Aortic Dissection Patients with Enlarging Aortas","volume":"9","author":"Chu","year":"2022","journal-title":"Front. Cardiovasc. Med."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"914","DOI":"10.1016\/j.jvs.2011.11.005","article-title":"A new imaging method for assessment of aortic dissection using four-dimensional phase contrast magnetic resonance imaging","volume":"55","author":"Clough","year":"2012","journal-title":"J. Vasc. Surg."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"O96","DOI":"10.1186\/1532-429X-18-S1-O96","article-title":"Improved assessment of aortic hemodynamics by k-t accelerated dual-VENC 4D flow MRI in pediatric patients","volume":"18","author":"Schnell","year":"2016","journal-title":"J. Cardiovasc. Magn. Reson."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1002\/mrm.27943","article-title":"Efficient triple-VENC phase-contrast MRI for improved velocity dynamic range","volume":"83","author":"Ma","year":"2020","journal-title":"Magn. Reson. Med."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1002\/jmri.25595","article-title":"Accelerated dual-venc 4D flow MRI for neurovascular applications","volume":"46","author":"Schnell","year":"2017","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1002\/mrm.1910330119","article-title":"Three-point phase-contrast velocity measurements with increased velocity-to-noise ratio","volume":"33","author":"Lee","year":"1995","journal-title":"Magn. Reson. Med."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1337","DOI":"10.1002\/mrm.24370","article-title":"Bayesian multipoint velocity encoding for concurrent flow and turbulence mapping","volume":"69","author":"Binter","year":"2013","journal-title":"Magn. Reson. Med."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/j.mri.2019.05.015","article-title":"Precision, reproducibility and applicability of an undersampled multi-venc 4D flow MRI sequence for the assessment of cardiac hemodynamics","volume":"61","author":"Moersdorf","year":"2019","journal-title":"Magn. Reson. Imaging"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"109570","DOI":"10.1016\/j.ejrad.2021.109570","article-title":"Velocity quantification in 44 healthy volunteers using accelerated multi-VENC 4D flow CMR","volume":"137","author":"Kroeger","year":"2021","journal-title":"Eur. J. Radiol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1355","DOI":"10.1002\/jmri.25106","article-title":"Comprehensive motion-compensated highly accelerated 4D flow MRI with ferumoxytol enhancement for pediatric congenital heart disease","volume":"43","author":"Cheng","year":"2016","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1148\/radiol.14140973","article-title":"Abdominal 4D flow MR imaging in a breath hold: Combination of spiral sampling and dynamic compressed sensing for highly accelerated acquisition","volume":"275","author":"Dyvorne","year":"2015","journal-title":"Radiology"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1186\/s12968-019-0573-0","article-title":"Accelerated aortic 4D flow cardiovascular magnetic resonance using compressed sensing: Applicability, validation and clinical integration","volume":"21","author":"Neuhaus","year":"2019","journal-title":"J. Cardiovasc. Magn. Reson."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"3675","DOI":"10.1002\/mrm.27684","article-title":"Aortic 4D flow MRI in 2 minutes using compressed sensing, respiratory controlled adaptive k-space reordering, and inline reconstruction","volume":"81","author":"Ma","year":"2019","journal-title":"Magn. Reson. Med."},{"key":"ref_31","first-page":"1752","article-title":"Hemodynamic evaluation of type B aortic dissection using compressed sensing accelerated 4D flow MRI","volume":"7","author":"Kilinc","year":"2022","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1002\/mrm.1910390218","article-title":"Concomitant gradient terms in phase contrast MR: Analysis and correction","volume":"39","author":"Bernstein","year":"1998","journal-title":"Magn. Reson. Med."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1002\/jmri.1880030315","article-title":"Semiautomated method for noise reduction and background phase error correction in MR phase velocity data","volume":"3","author":"Walker","year":"1993","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Bobak, C.A., Barr, P.J., and O\u2019Malley, A.J. (2018). Estimation of an inter-rater intra-class correlation coefficient that overcomes common assumption violations in the assessment of health measurement scales. BMC Med. Res. Methodol., 1218.","DOI":"10.1186\/s12874-018-0550-6"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1148\/radiol.12120055","article-title":"Evaluation of valvular insufficiency and shunts with parallel-imaging compressed-sensing 4D phase-contrast MR imaging with stereoscopic 3D velocity-fusion volume-rendered visualization","volume":"265","author":"Hsiao","year":"2012","journal-title":"Radiology"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1002\/mrm.27747","article-title":"Semi-automated analysis of 4D flow MRI to assess the hemodynamic impact of intracranial atherosclerotic disease","volume":"82","author":"Vali","year":"2019","journal-title":"Magn. Reson. Med."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1718","DOI":"10.1002\/jmri.26784","article-title":"Standardized evaluation of cerebral arteriovenous malformations using flow distribution network graphs and dual-venc 4D flow MRI","volume":"50","author":"Aristova","year":"2019","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"e95","DOI":"10.1093\/ehjci\/jeaa343","article-title":"Dual VENC 4D flow magnetic resonance imaging demonstrates arterial-pulmonary collaterals in an adult with tetralogy of Fallot","volume":"22","author":"Shiina","year":"2021","journal-title":"Eur. Heart J. Cardiovasc. Imaging"}],"container-title":["Applied Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2076-3417\/13\/10\/6202\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T19:38:01Z","timestamp":1760125081000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2076-3417\/13\/10\/6202"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,18]]},"references-count":38,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2023,5]]}},"alternative-id":["app13106202"],"URL":"https:\/\/doi.org\/10.3390\/app13106202","relation":{},"ISSN":["2076-3417"],"issn-type":[{"value":"2076-3417","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,5,18]]}}}