{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,19]],"date-time":"2026-01-19T02:33:02Z","timestamp":1768789982834,"version":"3.49.0"},"reference-count":65,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2021,9,30]],"date-time":"2021-09-30T00:00:00Z","timestamp":1632960000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Audiology Research"],"abstract":"<jats:p>Sound localization in daily life is one of the important functions of binaural hearing. Bilateral bone conduction devices (BCDs), middle ear implants, and cartilage conduction hearing aids have been often applied for patients with conductive hearing loss (CHL) or mixed hearing loss, for example, resulting from bilateral microtia and aural atresia. In this review, factors affecting the accuracy of sound localization with bilateral BCDs, middle ear implants, and cartilage conduction hearing aids were classified into four categories: (1) types of device, (2) experimental conditions, (3) participants, and (4) pathways from the stimulus sound to both cochleae. Recent studies within the past 10 years on sound localization and lateralization by BCDs, middle ear implants, and cartilage conduction hearing aids were discussed. Most studies showed benefits for sound localization or lateralization with bilateral devices. However, the judgment accuracy was generally lower than that for normal hearing, and the localization errors tended to be larger than for normal hearing. Moreover, it should be noted that the degree of accuracy in sound localization by bilateral BCDs varied considerably among patients. Further research on sound localization is necessary to analyze the complicated mechanism of bone conduction, including suprathreshold air conduction with bilateral devices.<\/jats:p>","DOI":"10.3390\/audiolres11040046","type":"journal-article","created":{"date-parts":[[2021,9,30]],"date-time":"2021-09-30T10:22:42Z","timestamp":1632997362000},"page":"508-523","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Sound Localization and Lateralization by Bilateral Bone Conduction Devices, Middle Ear Implants, and Cartilage Conduction Hearing Aids"],"prefix":"10.3390","volume":"11","author":[{"given":"Kimio","family":"Shiraishi","sequence":"first","affiliation":[{"name":"Department of Communication Design Science, Faculty of Design, Kyushu University, Fukuoka 815-0032, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2021,9,30]]},"reference":[{"key":"ref_1","unstructured":"Moore, B.C.J. (2003). 7. Space perception. An Introduction to the Psychology of Hearing, Academic Press. [5th ed.]."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Plack, C.J. (2005). 9. Spatial hearing. The Sense of Hearing, Psychology Press.","DOI":"10.4324\/9781410613745"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"158","DOI":"10.3109\/00206090109073111","article-title":"Audiometric evaluation of bilaterally fitted bone-anchored hearing aids","volume":"40","author":"Bosman","year":"2001","journal-title":"Audiology"},{"key":"ref_4","first-page":"1","article-title":"Sound localization in subjects with impaired hearing. Spatial-discrimination and interaural-discrimination tests","volume":"400","author":"Colburn","year":"1983","journal-title":"Acta Otolaryngol. Suppl."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"311","DOI":"10.3109\/00206099509071921","article-title":"Factors in subjective hearing disability","volume":"34","author":"Kramer","year":"1995","journal-title":"Audiology"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"302","DOI":"10.3109\/00206099809072984","article-title":"The self-reported handicapping effect of hearing disabilities","volume":"37","author":"Kramer","year":"1998","journal-title":"Audiology"},{"key":"ref_7","first-page":"783","article-title":"Hearing by bone conduction and the use of bone-conduction hearing aids","volume":"45","author":"Littler","year":"1952","journal-title":"Proc. R. Soc. Med."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1177\/000348949810700301","article-title":"Binaural application of the bone-anchored hearing aid","volume":"107","author":"Snik","year":"1998","journal-title":"Ann Otol. Rhinol. Laryngol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"85","DOI":"10.3109\/00016488009127113","article-title":"Analysis of the mechanical impedance of bone-anchored hearing aids","volume":"89","author":"Rosenhall","year":"1980","journal-title":"Acta Otolaryngol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1177\/014556139407300210","article-title":"Long-term follow-up with the bone-anchored hearing aid: A review of the first 100 patients between 1977 and 1985","volume":"73","year":"1994","journal-title":"Ear Nose Throat J."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1097\/00005537-200401000-00013","article-title":"Bilateral bone-anchored hearing aids (BAHAs): An audiometric evaluation","volume":"114","author":"Priwin","year":"2004","journal-title":"Laryngoscope"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1177\/0194599812451569","article-title":"Bilateral bone-anchored hearing aids for bilateral permanent conductive hearing loss: A systematic review","volume":"147","author":"Janssen","year":"2012","journal-title":"Otolaryngol. Head Neck Surg."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/j.ijporl.2006.09.014","article-title":"BAHA in children and adolescents with unilateral or bilateral conductive hearing loss: A study of outcome","volume":"71","author":"Priwin","year":"2007","journal-title":"Int. J. Pediatr. Otorhinolaryngol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1080\/000164801300043820","article-title":"Bone-conducted sound lateralization of interaural time difference and interaural intensity difference in children and a young adult with bilateral microtia and atresia of the ears","volume":"121","author":"Kaga","year":"2001","journal-title":"Acta Otolaryngol."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1016\/j.heares.2004.11.012","article-title":"Time-intensity trading in bilateral congenital aural atresia patients","volume":"202","author":"Schmerber","year":"2005","journal-title":"Hear. Res."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"79","DOI":"10.2147\/MDER.S39691","article-title":"New developments in bone-conduction hearing implants: A review","volume":"8","author":"Reinfeldt","year":"2015","journal-title":"Med. Devices"},{"key":"ref_17","unstructured":"(2021, March 31). ADHEAR. Available online: https:\/\/blog.medel.pro\/adhear-hearing-system\/."},{"key":"ref_18","first-page":"104","article-title":"Development of cartilage conduction hearing aid","volume":"42","author":"Hosoi","year":"2010","journal-title":"Arch. Mater. Sci. Eng."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"690","DOI":"10.1097\/AUD.0000000000000336","article-title":"Binaural hearing ability with bilateral bone conduction stimulation in subjects with normal hearing: Implications for bone conduction hearing aids","volume":"37","author":"Zeitooni","year":"2016","journal-title":"Ear Hear."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1080\/14992020400050014","article-title":"The speech, spatial and qualities of hearing scale (SSQ)","volume":"43","author":"Gatehouse","year":"2004","journal-title":"Int J. Audiol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.1097\/MAO.0000000000001924","article-title":"Unilateral and bilateral audiological benefit with an adhesively attached, noninvasive bone conduction hearing system","volume":"39","author":"Gawliczek","year":"2018","journal-title":"Otol. Neurotol."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"5264124","DOI":"10.1155\/2018\/5264124","article-title":"Speech understanding and sound localization with a new nonimplantable wearing option for Baha","volume":"2018","author":"Gawliczek","year":"2018","journal-title":"BioMed. Res. Int."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"107881","DOI":"10.1016\/j.heares.2019.107881","article-title":"Bilateral bone conduction stimulation provides reliable binaural cues for localization","volume":"388","author":"Snapp","year":"2020","journal-title":"Hear. Res."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"806","DOI":"10.1097\/AUD.0b013e318291784e","article-title":"Bilateral bone conduction devices: Improved hearing ability in children with bilateral conductive hearing loss","volume":"34","author":"Dun","year":"2013","journal-title":"Ear Hear."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1080\/00016489.2020.1745883","article-title":"Comparative effects of unilateral and bilateral bone conduction hearing devices on functional hearing and sound localization abilities in patients with bilateral microtia-atresia","volume":"140","author":"Fan","year":"2020","journal-title":"Acta Otolaryngol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1327","DOI":"10.1097\/AUD.0000000000000853","article-title":"The merits of bilateral application of bone-conduction devices in children with bilateral conductive hearing loss","volume":"41","author":"Besten","year":"2020","journal-title":"Ear Hear."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"891","DOI":"10.1080\/14992027.2020.1802671","article-title":"Sound localisation ability using cartilage conduction hearing aids in bilateral aural atresia","volume":"59","author":"Nishimura","year":"2020","journal-title":"Int. J. Audiol."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1089","DOI":"10.1111\/coa.13770","article-title":"Instant auditory benefit of an adhesive BCHD on children with bilateral congenital microtia","volume":"46","author":"Ren","year":"2021","journal-title":"Clin. Otolaryngol."},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Caspers, C.J.I., Janssen, A.M., Agterberg, M.J.H., Cremers, C.W.R.J., Hol, M.K.S., and Bosman, A.J. (2021). Sound localization with bilateral bone conduction devices. Eur. Arch. Otorhinolaryngol.","DOI":"10.1007\/s00405-021-06842-1"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"926","DOI":"10.1080\/00016480500536871","article-title":"Bone-conducted auditory brainstem-evoked responses and skull vibratory velocity measurement in rats at frequencies of 0.5\u201330 kHz with a new giant magnetostrictive bone conduction transducer","volume":"126","author":"Sakai","year":"2016","journal-title":"Acta Otolaryngol."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1121\/1.2208429","article-title":"Perceptual recalibration in human sound localization: Learning to remediate front-back reversals","volume":"120","author":"Zahorik","year":"2006","journal-title":"J. Acoust Soc. Am."},{"key":"ref_32","unstructured":"(2021, March 31). ADHEAR SYSTEM Including the ADHEAR Audio Processor and the ADHEAR Adhesive Adapter Technical Data. Available online: https:\/\/s3.medel.com\/pdf\/28867_40_ADHEAR_Factsheet_English.pdf."},{"key":"ref_33","unstructured":"(2021, March 31). Cochlear\u2122 Baha\u00ae5 Sound Processor Data Sheet. Available online: https:\/\/www.cochlear.com\/3116aa05-0d7d-4806-9ed4-7ddb058d8998\/BUN335-ISS2-OCT17-Baha5-SP-Datasheet.pdf?MOD=AJPERES&CVID=nlcuPdQ."},{"key":"ref_34","unstructured":"Cire, G. (2021, July 23). The Baha 5 Sound Processor Overview, Audio Online, Available online: https:\/\/www.audiologyonline.com\/articles\/baha-5-sound-processor-overview-14427."},{"key":"ref_35","unstructured":"(2021, March 31). The BonebridgeTM Bone Conduction Implant System Data Sheet. Available online: https:\/\/s3.medel.com\/pdf\/INT\/professionals_brochure2014.pdf."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"1234","DOI":"10.1016\/j.apacoust.2013.04.013","article-title":"Development of monaural and binaural behind-the-ear cartilage conduction hearing aids","volume":"74","author":"Shimokura","year":"2013","journal-title":"Appl. Acoust"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"1732","DOI":"10.1121\/1.5126521","article-title":"On the limitations of sound localization with hearing devices","volume":"146","author":"Denk","year":"2019","journal-title":"J. Acoust Soc. Am."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1080\/14992020600920804","article-title":"The effect of multi-channel wide dynamic range compression, noise reduction, and the dsirectional microphone on horizontal localization performance in hearing aid wearers","volume":"45","author":"Keidser","year":"2006","journal-title":"Int. J. Audiol."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1121\/1.2139653","article-title":"Horizontal localization with bilateral hearing aids: Without is better than with","volume":"119","author":"Klasen","year":"2006","journal-title":"J. Acoust Soc. Am."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.4081\/audiores.2013.e1","article-title":"Evaluation of speech intelligibility and sound localization abilities with hearing aids using binaural wireless technology","volume":"3","author":"Ibrahim","year":"2013","journal-title":"Audiol. Res."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"746","DOI":"10.1097\/AUD.0000000000000473","article-title":"Impact of Hearing Aid Technology on Outcomes in Daily Life III: Localization","volume":"38","author":"Johnson","year":"2017","journal-title":"Ear Hear."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1097\/MAO.0b013e31823e28ab","article-title":"Transcranial attenuation of bone-conducted sound when stimulation is at the mastoid and at the bone conduction hearing aid position","volume":"33","author":"Stenfelt","year":"2012","journal-title":"Otol. Neurotol."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"439","DOI":"10.3109\/14992027.2016.1172120","article-title":"Influence of stimulation position on the sensitivity for bone conduction hearing aids without skin penetration","volume":"55","author":"Dobrev","year":"2016","journal-title":"Int. J. Audiol."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1250\/ast.40.259","article-title":"Effect of the contact condition of the actuator on the sound localization of bone-conducted reproduction","volume":"40","author":"Asakura","year":"2019","journal-title":"Acoust Sci. Technol"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1146\/annurev.ps.42.020191.001031","article-title":"Sound localization by human listeners","volume":"42","author":"Middlebrooks","year":"1991","journal-title":"Annu Rev. Psychol."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/0378-5955(86)90047-X","article-title":"The bandwidth effect on monaural and binaural localization","volume":"21","author":"Butler","year":"1986","journal-title":"Hear. Res."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1121\/1.1909553","article-title":"On the minimum audible angle","volume":"30","author":"Mills","year":"1958","journal-title":"J. Acoust Soc. Am."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1044\/1092-4388(2011\/11-0096)","article-title":"The developmental trajectory of spatial listening skills in normal-hearing children","volume":"55","author":"Lovett","year":"2012","journal-title":"J. Speech Lang. Hear. Res."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"e104","DOI":"10.1097\/AUD.0000000000000235","article-title":"Corneal-reflection eye-tracking technique for the assessment of horizontal sound localization accuracy from 6 months of age","volume":"37","author":"Asp","year":"2016","journal-title":"Ear Hear."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"2737","DOI":"10.1121\/1.4898045","article-title":"Sound source localization identification accuracy: Bandwidth dependencies","volume":"136","author":"Yost","year":"2014","journal-title":"J. Acoust Soc. Am."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"1695","DOI":"10.1121\/1.394282","article-title":"Localization of sound in rooms, III: Onset and duration effects","volume":"80","author":"Rakerd","year":"1986","journal-title":"J. Acoust Soc. Am."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/j.heares.2017.11.008","article-title":"The effect of simulated unilateral hearing loss on horizontal sound localization accuracy and recognition of speech in spatially separate competing speech","volume":"357","author":"Asp","year":"2018","journal-title":"Hear. Res."},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"368","DOI":"10.3109\/00016489.2015.1103900","article-title":"Sound lateralization test in patients with unilateral microtia and atresia after reconstruction of the auricle and external canal and fitting of canal-type hearing aids","volume":"136","author":"Kaga","year":"2016","journal-title":"Acta Otolaryngol."},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1044\/jshd.3204.360","article-title":"Clinical masking of the nontest ear","volume":"32","author":"Studebaker","year":"1967","journal-title":"J. Speech Hear. Disord"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1111\/j.1442-200X.1992.tb00939.x","article-title":"Development of sound localization","volume":"34","author":"Kaga","year":"1992","journal-title":"Acta Paediatr. Jpn."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1016\/j.heares.2014.11.005","article-title":"Localization training results in individuals with unilateral severe to profound hearing loss","volume":"319","author":"Firszt","year":"2015","journal-title":"Hear. Res."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1121\/1.1908493","article-title":"Some measurements of interaural time difference thresholds","volume":"28","author":"Klumpp","year":"1956","journal-title":"J. Acoust Soc. Am."},{"key":"ref_58","unstructured":"Eeg-Olofsson, M. (2021, March 31). Transmission of Bone-Conducted Sound in the Human Skull Based on Vibration and Perceptual Measures. Available online: https:\/\/gupea.ub.gu.se\/bitstream\/2077\/28248\/1\/gupea_2077_28248_1.pdf."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"481","DOI":"10.1121\/1.4807637","article-title":"Binaural hearing ability with mastoid applied bilateral bone conduction stimulation in normal hearing subjects","volume":"134","author":"Stenfelt","year":"2013","journal-title":"J. Acoust Soc. Am."},{"key":"ref_60","doi-asserted-by":"crossref","unstructured":"R\u00f6\u00f6sli, C., Dobrev, I., and Pfiffner, F. (2021). Transcranial attenuation in bone conduction stimulation. Ear Hear., in press.","DOI":"10.1016\/j.heares.2021.108318"},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"1277","DOI":"10.1121\/1.1908622","article-title":"Response of the human skull to mechanical vibrations","volume":"28","author":"Franke","year":"1956","journal-title":"J. Acoust Soc. Am."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"95","DOI":"10.3109\/00016486409121366","article-title":"Bone Conduction of sound pulse waves. Physical measurement of velocity","volume":"58","author":"Wigand","year":"1964","journal-title":"Acta Otolaryngol."},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"1294","DOI":"10.1121\/1.387143","article-title":"Velocity of propagation of bone-conducted sound in a human head","volume":"70","author":"Tonndorf","year":"1981","journal-title":"J. Acoust Soc. Am."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"2373","DOI":"10.1121\/1.2005847","article-title":"Transmission properties of bone conducted sound: Measurements in cadaver heads","volume":"118","author":"Stenfelt","year":"2005","journal-title":"J. Acoust Soc. Am."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"1476","DOI":"10.1097\/MAO.0000000000001556","article-title":"Intracochlear measurements of interaural time and level differences conveyed by bilateral bone conduction systems","volume":"38","author":"Farrell","year":"2017","journal-title":"Otol. Neurotol."}],"container-title":["Audiology Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2039-4349\/11\/4\/46\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T07:07:59Z","timestamp":1760166479000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2039-4349\/11\/4\/46"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9,30]]},"references-count":65,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2021,12]]}},"alternative-id":["audiolres11040046"],"URL":"https:\/\/doi.org\/10.3390\/audiolres11040046","relation":{},"ISSN":["2039-4349"],"issn-type":[{"value":"2039-4349","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,9,30]]}}}