{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T21:04:06Z","timestamp":1786568646424,"version":"build-2736575974"},"reference-count":60,"publisher":"MDPI AG","issue":"7","license":[{"start":{"date-parts":[[2024,6,28]],"date-time":"2024-06-28T00:00:00Z","timestamp":1719532800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000002","name":"NINDS","doi-asserted-by":"publisher","award":["K23-NS124688"],"award-info":[{"award-number":["K23-NS124688"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Bioengineering"],"abstract":"<jats:p>Trunk and pelvis range of motion (ROM) is essential to perform activities of daily living. The ROM may become limited with aging or with neuromusculoskeletal disorders. Inertial measurement units (IMU) with out-of-the box software solutions are increasingly being used to assess motion. We hypothesize that the accuracy (validity) and reliability (consistency) of the trunk and pelvis ROM during steady-state gait in normal individuals as measured using the Opal APDM 6 sensor IMU system and calculated using Mobility Lab version 4 software will be comparable to a gold-standard optoelectric motion capture system. Thirteen healthy young adults participated in the study. Trunk ROM, measured using the IMU was within 5\u20137 degrees of the motion capture system for all three planes and within 10 degrees for pelvis ROM. We also used a triad of markers mounted on the sternum and sacrum IMU for a head-to-head comparison of trunk and pelvis ROM. The IMU measurements were within 5\u201310 degrees of the triad. A greater variability of ROM measurements was seen for the pelvis in the transverse plane. IMUs and their custom software provide a valid and reliable measurement for trunk and pelvis ROM in normal individuals, and important considerations for future applications are discussed.<\/jats:p>","DOI":"10.3390\/bioengineering11070659","type":"journal-article","created":{"date-parts":[[2024,6,28]],"date-time":"2024-06-28T03:42:30Z","timestamp":1719546150000},"page":"659","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Validation of Pelvis and Trunk Range of Motion as Assessed Using Inertial Measurement Units"],"prefix":"10.3390","volume":"11","author":[{"given":"Farwa","family":"Ali","sequence":"first","affiliation":[{"name":"Department of Neurology, Mayo Clinic, Rochester, MN 55905, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cecilia A.","family":"Hogen","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN 55905, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emily J.","family":"Miller","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN 55905, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenton R.","family":"Kaufman","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN 55905, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2024,6,28]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1001\/jama.2013.13805","article-title":"The state of US health, 1990\u20132010: Burden of diseases, injuries, and risk factors","volume":"310","author":"Murray","year":"2013","journal-title":"JAMA"},{"key":"ref_2","unstructured":"(2018). Global, regional, and national incidence, prevalence, and years lived with disability for 354 diseases and injuries for 195 countries and territories, 1990\u20132017: A systematic analysis for the Global Burden of Disease Study 2017. Lancet Lond Engl., 392, 1789\u20131858."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"370","DOI":"10.1016\/j.gaitpost.2015.01.019","article-title":"Motion analysis of patients after knee arthroplasty during activities of daily living\u2014A systematic review","volume":"41","author":"Komnik","year":"2015","journal-title":"Gait Posture"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.bjpt.2017.03.012","article-title":"Hip, knee, and ankle kinematics during activities of daily living: A cross-sectional study","volume":"21","author":"Hyodo","year":"2017","journal-title":"Braz. J. Phys. Ther."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"2333721417703734","DOI":"10.1177\/2333721417703734","article-title":"Association of Fatigue With Sarcopenia and its Elements: A Secondary Analysis of SABE-Bogot\u00e1","volume":"3","author":"Borda","year":"2017","journal-title":"Gerontol. Geriatr. Med."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1093\/gerona\/glv126","article-title":"Gait Speed Predicts Incident Disability: A Pooled Analysis","volume":"71","author":"Perera","year":"2016","journal-title":"J. Gerontol. Ser. A Biomed. Sci. Med. Sci."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"726","DOI":"10.1093\/gerona\/gls224","article-title":"Cognitive function, gait, and gait variability in older people: A population-based study","volume":"68","author":"Martin","year":"2013","journal-title":"J. Gerontol. Ser. A Biomed. Sci. Med. Sci."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1605","DOI":"10.1001\/jama.2023.3054","article-title":"Trends in Deaths From Falls Among Adults Aged 65 Years or Older in the US, 1999\u20132020","volume":"329","year":"2023","journal-title":"JAMA"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/j.gaitpost.2023.05.004","article-title":"The effect of walking with reduced trunk motion on dynamic stability in healthy adults","volume":"103","author":"Buurke","year":"2023","journal-title":"Gait Posture"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"2200","DOI":"10.1080\/02640414.2020.1776914","article-title":"The relationships between pelvic range of motion, step width and performance during an athletic sprint start","volume":"38","author":"Sandamas","year":"2020","journal-title":"J. Sports Sci."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Voglar, M., Kozinc, \u017d., Kingma, I., van Die\u00ebn, J.H., and \u0160arabon, N. (2022). The Effects of Intermittent Trunk Flexion with and without Support on Sitting Balance in Young Adults. Front. Hum. Neurosci., Available online: https:\/\/www.frontiersin.org\/articles\/10.3389\/fnhum.2022.868153.","DOI":"10.3389\/fnhum.2022.868153"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1016\/j.math.2004.10.004","article-title":"A normative database of lumbar spine ranges of motion","volume":"10","author":"Troke","year":"2005","journal-title":"Man. Ther."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Cano-de-la-Cuerda, R., Vela-Desojo, L., Moreno-Verd\u00fa, M., Ferreira-S\u00e1nchez, M.D.R., Mac\u00edas-Mac\u00edas, Y., and Miangolarra-Page, J.C. (2020). Trunk Range of Motion Is Related to Axial Rigidity, Functional Mobility and Quality of Life in Parkinson\u2019s Disease: An Exploratory Study. Sensors, 20.","DOI":"10.3390\/s20092482"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Storm, F.A., Nair, K.P.S., Clarke, A.J., Meulen, J.M.V., and der Mazz\u00e0, C. (2018). Free-living and laboratory gait characteristics in patients with multiple sclerosis. PLoS ONE, 13.","DOI":"10.1371\/journal.pone.0196463"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Moore, J., Stuart, S., McMeekin, P., Walker, R., Celik, Y., Pointon, M., and Godfrey, A. (2023). Enhancing Free-Living Fall Risk Assessment: Contextualizing Mobility Based IMU Data. Sensors, 23.","DOI":"10.3390\/s23020891"},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Robert-Lachaine, X., Mecheri, H., Muller, A., Larue, C., and Plamondon, A. (2020). Validation of a low-cost inertial motion capture system for whole-body motion analysis. J. Biomech., 99.","DOI":"10.1016\/j.jbiomech.2019.109520"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1016\/j.gaitpost.2017.05.026","article-title":"Static and dynamic validation of inertial measurement units","volume":"57","author":"Taylor","year":"2017","journal-title":"Gait Posture"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1123\/jab.2016-0120","article-title":"Validation of Inertial Measurement Units for Upper Body Kinematics","volume":"33","author":"Morrow","year":"2017","journal-title":"J. Appl. Biomech."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"782","DOI":"10.1016\/j.jelekin.2015.06.001","article-title":"Concurrent validity and reliability of a novel wireless inertial measurement system to assess trunk movement","volume":"25","author":"Bauer","year":"2015","journal-title":"J. Electromyogr. Kinesiol."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Mikami, K., Shiraishi, M., Kawasaki, T., and Kamo, T. (2017). Forward flexion of trunk in Parkinson\u2019s disease patients is affected by subjective vertical position. PLoS ONE, 12.","DOI":"10.1371\/journal.pone.0181210"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/j.jmpt.2019.04.003","article-title":"Quantifying Lumbar Mobilization With Inertial Measurement Unit","volume":"43","author":"Mehyar","year":"2020","journal-title":"J. Manip. Physiol. Ther."},{"key":"ref_22","doi-asserted-by":"crossref","unstructured":"Al-Amri, M., Nicholas, K., Button, K., Sparkes, V., Sheeran, L., and Davies, J.L. (2018). Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity. Sensors, 18.","DOI":"10.3390\/s18030719"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"e10623","DOI":"10.7717\/peerj.10623","article-title":"A novel IMU-based clinical assessment protocol for Axial Spondyloarthritis: A protocol validation study","volume":"9","author":"Franco","year":"2021","journal-title":"PeerJ"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1586\/17434440.2016.1153421","article-title":"Potential of APDM Mobility Lab for the monitoring of the progression of Parkinson\u2019s disease","volume":"13","author":"Mancini","year":"2016","journal-title":"Expert Rev. Med. Devices"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1016\/j.gaitpost.2016.05.014","article-title":"Accuracy and Repeatability of two methods of gait analysis\u2014GaitRiteTM und Mobility LabTM\u2014In subjects with cerebellar ataxia","volume":"48","author":"Brandt","year":"2016","journal-title":"Gait Posture"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"095003","DOI":"10.1088\/1361-6579\/ab4023","article-title":"Validity of Mobility Lab (version 2) for gait assessment in young adults, older adults and Parkinson\u2019s disease","volume":"40","author":"Morris","year":"2019","journal-title":"Physiol. Meas."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1016\/0167-9457(91)90046-Z","article-title":"A gait analysis data collection and reduction technique","volume":"10","author":"Davis","year":"1991","journal-title":"Hum. Mov. Sci."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1080\/10543400701329422","article-title":"Agreement between methods of measurement with multiple observations per individual","volume":"17","author":"Bland","year":"2007","journal-title":"J. Biopharm. Stat."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"3094","DOI":"10.1177\/03635465211029017","article-title":"Are Wearable Sensors Valid and Reliable for Studying the Baseball Pitching Motion? An Independent Comparison with Marker-Based Motion Capture","volume":"49","author":"Camp","year":"2021","journal-title":"Am. J. Sports Med."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Poitras, I., Dupuis, F., Bielmann, M., Campeau-Lecours, A., Mercier, C., Bouyer, L.J., and Roy, J.S. (2019). Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review. Sensors, 19.","DOI":"10.3390\/s19071555"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"102589","DOI":"10.1016\/j.jelekin.2021.102589","article-title":"Evaluating the validity and reliability of inertial measurement units for determining knee and trunk kinematics during athletic landing and cutting movements","volume":"60","author":"Chia","year":"2021","journal-title":"J. Electromyogr. Kinesiol."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1109\/JSEN.2016.2630938","article-title":"Magneto-Gyro Wearable Sensor Algorithm for Trunk Sway Estimation During Walking and Running Gait","volume":"17","author":"Shull","year":"2017","journal-title":"IEEE Sens. J."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1108\/02602280710731713","article-title":"Inertial sensors for motion detection of human upper limbs","volume":"27","author":"Zhou","year":"2007","journal-title":"Sens Rev."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"1061","DOI":"10.1007\/s11517-006-0132-3","article-title":"Development of a real-time three-dimensional spinal motion measurement system for clinical practice","volume":"44","author":"Goodvin","year":"2006","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"697","DOI":"10.1016\/j.apergo.2006.12.006","article-title":"Evaluation of a hybrid system for three-dimensional measurement of trunk posture in motion","volume":"38","author":"Plamondon","year":"2007","journal-title":"Appl. Ergon."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1016\/j.math.2006.07.005","article-title":"Wireless orientation sensors: Their suitability to measure head movement for neck pain assessment","volume":"12","author":"Jasiewicz","year":"2007","journal-title":"Man Ther."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1007\/s11517-009-0562-9","article-title":"Ambulatory human motion tracking by fusion of inertial and magnetic sensing with adaptive actuation","volume":"48","author":"Schepers","year":"2010","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1109\/TBME.2006.889184","article-title":"Ambulatory position and orientation tracking fusing magnetic and inertial sensing","volume":"54","author":"Roetenberg","year":"2007","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/j.jbmt.2020.06.008","article-title":"Concurrent validity and within-session reliability of gait kinematics measured using an inertial motion capture system with repeated calibration","volume":"24","author":"Berner","year":"2020","journal-title":"J. Bodyw. Mov. Ther."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1016\/j.medengphy.2015.11.009","article-title":"Validity of an inertial measurement unit to assess pelvic orientation angles during gait, sit\u2013stand transfers and step-up transfers: Comparison with an optoelectronic motion capture system*","volume":"38","author":"Bolink","year":"2016","journal-title":"Med. Eng. Phys."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1111\/sms.13851","article-title":"3D trunk orientation measured using inertial measurement units during anatomical and dynamic sports motions","volume":"31","author":"Brouwer","year":"2021","journal-title":"Scand. J. Med. Sci. Sports"},{"key":"ref_42","doi-asserted-by":"crossref","unstructured":"Wang, X., Qureshi, A., Vepa, A., Rahman, U., Palit, A., Williams, M.A., King, R., and Elliott, M.T. (2020). A Sensor-Based Screening Tool for Identifying High Pelvic Mobility in Patients Due to Undergo Total Hip Arthroplasty. Sensors, 20.","DOI":"10.3390\/s20216182"},{"key":"ref_43","doi-asserted-by":"crossref","unstructured":"Catelli, D.S., Cotter, B., Lamontagne, M., and Grammatopoulos, G. (2021). Spine, Pelvis and Hip Kinematics\u2014Characterizing the Axial Plane in Healthy and Osteoarthritic Hips. Appl. Sci., 11.","DOI":"10.3390\/app11219921"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1080\/24725838.2018.1559261","article-title":"Lumbopelvic Kinematics in the Primary and Secondary Planes of Motion During Lateral Bending and Axial Twisting: Age-Related Differences","volume":"7","author":"Vazirian","year":"2019","journal-title":"IISE Trans. Occup. Ergon. Hum. Factors"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"1125","DOI":"10.1249\/MSS.0b013e3182825aca","article-title":"Relationship between hip strength and trunk motion in college cross-country runners","volume":"45","author":"Ford","year":"2013","journal-title":"Med. Sci. Sports Exerc."},{"key":"ref_46","doi-asserted-by":"crossref","unstructured":"Taniguchi, M., Tateuchi, H., Ibuki, S., and Ichihashi, N. (2017). Relative mobility of the pelvis and spine during trunk axial rotation in chronic low back pain patients: A case-control study. PLoS ONE, 12.","DOI":"10.1371\/journal.pone.0186369"},{"key":"ref_47","first-page":"83","article-title":"Three-dimensional analysis of the pelvic and hip mobility during gait on a treadmill and on the ground","volume":"14","author":"Staszkiewicz","year":"2012","journal-title":"Acta Bioeng. Biomech. Wroc. Univ. Technol."},{"key":"ref_48","doi-asserted-by":"crossref","unstructured":"Cerfoglio, S., Capodaglio, P., Rossi, P., Conforti, I., D\u2019Angeli, V., Milani, E., Galli, M., and Cimolin, V. (2023). Evaluation of Upper Body and Lower Limbs Kinematics through an IMU-Based Medical System: A Comparative Study with the Optoelectronic System. Sensors, 23.","DOI":"10.3390\/s23136156"},{"key":"ref_49","doi-asserted-by":"crossref","unstructured":"Rattanakoch, J., Samala, M., Limroongreungrat, W., Guerra, G., Tharawadeepimuk, K., Nanbancha, A., Niamsang, W., Kerdsomnuek, P., and Suwanmana, S. (2023). Validity and Reliability of Inertial Measurement Unit (IMU)-Derived 3D Joint Kinematics in Persons Wearing Transtibial Prosthesis. Sensors, 23.","DOI":"10.3390\/s23031738"},{"key":"ref_50","doi-asserted-by":"crossref","unstructured":"Bent, M.A., Ciccodicola, E.M., Rethlefsen, S.A., and Wren, T.A.L. (2021). Increased Asymmetry of Trunk, Pelvis, and Hip Motion during Gait in Ambulatory Children with Spina Bifida. Symmetry, 13.","DOI":"10.3390\/sym13091595"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"786","DOI":"10.1097\/01241398-199611000-00016","article-title":"Three-dimensional gait analysis in spina bifida","volume":"16","author":"Duffy","year":"1996","journal-title":"J. Pediatr. Orthop."},{"key":"ref_52","doi-asserted-by":"crossref","unstructured":"Vayalapra, S., Wang, X., Qureshi, A., Vepa, A., Rahman, U., Palit, A., Williams, M.A., King, R., and Elliott, M.T. (2022). Repeatability of Inertial Measurement Units for Measuring Pelvic Mobility in Patients Undergoing Total Hip Arthroplasty. Sensors, 23.","DOI":"10.3390\/s23010377"},{"key":"ref_53","doi-asserted-by":"crossref","unstructured":"Rekant, J., Rothenberger, S., and Chambers, A. (2024). Obesity-Specific Considerations for Assessing Gait with Inertial Measurement Unit-Based vs. Optokinetic Motion Capture. Sensors, 24.","DOI":"10.20944\/preprints202401.0866.v1"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"2369","DOI":"10.1002\/mds.23292","article-title":"Falls in Parkinson\u2019s disease: Kinematic evidence for impaired head and trunk control","volume":"25","author":"Cole","year":"2010","journal-title":"Mov. Disord."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1016\/j.gaitpost.2018.07.181","article-title":"Fallers with Parkinson\u2019s disease exhibit restrictive trunk control during walking","volume":"65","author":"Jehu","year":"2018","journal-title":"Gait Posture"},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.clineuro.2015.11.016","article-title":"Post-surgical functional recovery, lumbar lordosis, and range of motion associated with MR-detectable redundant nerve roots in lumbar spinal stenosis","volume":"140","author":"Chen","year":"2016","journal-title":"Clin. Neurol. Neurosurg."},{"key":"ref_57","doi-asserted-by":"crossref","unstructured":"Igawa, T., Katsuhira, J., Hosaka, A., Uchikoshi, K., Ishihara, S., and Matsudaira, K. (2018). Kinetic and kinematic variables affecting trunk flexion during level walking in patients with lumbar spinal stenosis. PLoS ONE, 13.","DOI":"10.1371\/journal.pone.0197228"},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"2263","DOI":"10.1002\/mds.29194","article-title":"Longitudinal Monitoring of Progressive Supranuclear Palsy using Body-Worn Movement Sensors","volume":"37","author":"Sotirakis","year":"2022","journal-title":"Mov. Disord."},{"key":"ref_59","doi-asserted-by":"crossref","unstructured":"Lebleu, J., Gosseye, T., Detrembleur, C., Mahaudens, P., Cartiaux, O., and Penta, M. (2020). Lower Limb Kinematics Using Inertial Sensors during Locomotion: Accuracy and Reproducibility of Joint Angle Calculations with Different Sensor-to-Segment Calibrations. Sensors, 20.","DOI":"10.3390\/s20030715"},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1179\/1743288X11Y.0000000006","article-title":"The use of inertial sensors system for human motion analysis","volume":"15","author":"Williams","year":"2010","journal-title":"Phys. Ther. Rev."}],"container-title":["Bioengineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2306-5354\/11\/7\/659\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T15:06:44Z","timestamp":1760108804000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2306-5354\/11\/7\/659"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,28]]},"references-count":60,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2024,7]]}},"alternative-id":["bioengineering11070659"],"URL":"https:\/\/doi.org\/10.3390\/bioengineering11070659","relation":{},"ISSN":["2306-5354"],"issn-type":[{"value":"2306-5354","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,6,28]]}}}