{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T17:32:35Z","timestamp":1791912755057,"version":"4.3.4"},"reference-count":77,"publisher":"MDPI AG","issue":"12","license":[{"start":{"date-parts":[[2024,12,5]],"date-time":"2024-12-05T00:00:00Z","timestamp":1733356800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Bioengineering"],"abstract":"<jats:p>The implementation of clinical 7T MRI presents both opportunities and challenges for advanced medical imaging. This tutorial provides practical considerations and experiences with 7T MRI in clinical settings. We first explore the history and evolution of MRI technology, highlighting the benefits of increased signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and susceptibility at 7T. Technical challenges such as increased susceptibility artifacts and RF inhomogeneity are also discussed, along with innovative adaptations. This review also discusses hardware and software considerations, including new parallel transmission head coils and advanced image processing techniques to optimize image quality. Safety considerations, such as managing tissue heating and susceptibility to artifacts, are also discussed. Additionally, clinical applications of 7T MRI are examined, focusing on neurological conditions such as epilepsy, multiple sclerosis, and vascular imaging. Emerging trends in the use of 7T MRI for spectroscopy, perfusion imaging, and multinuclear imaging are explored, with insights into the future of ultra-high-field MRI in clinical practice. This review aims to provide clinicians, technologists, and researchers with a roadmap for successfully implementing 7T MRI in both research and clinical environments.<\/jats:p>","DOI":"10.3390\/bioengineering11121228","type":"journal-article","created":{"date-parts":[[2024,12,5]],"date-time":"2024-12-05T04:13:03Z","timestamp":1733371983000},"page":"1228","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["How to Implement Clinical 7T MRI\u2014Practical Considerations and Experience with Ultra-High-Field MRI"],"prefix":"10.3390","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0350-184X","authenticated-orcid":false,"given":"Justin","family":"Cramer","sequence":"first","affiliation":[{"name":"Department of Radiology, Mayo Clinic Arizona, 5711 E Mayo Blvd, Phoenix, AZ 85054, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7145-833X","authenticated-orcid":false,"given":"Ichiro","family":"Ikuta","sequence":"additional","affiliation":[{"name":"Department of Radiology, Mayo Clinic Arizona, 5711 E Mayo Blvd, Phoenix, AZ 85054, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuxiang","family":"Zhou","sequence":"additional","affiliation":[{"name":"Department of Radiology, Mayo Clinic Arizona, 5711 E Mayo Blvd, Phoenix, AZ 85054, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2024,12,5]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/S0140-6736(07)60151-2","article-title":"Magnetic resonance imaging and computed tomography in emergency assessment of patients with suspected acute stroke: A prospective comparison","volume":"369","author":"Chalela","year":"2007","journal-title":"Lancet"},{"key":"ref_2","unstructured":"Bushberg, J.T., Seibert, J.A., Leidholdt, E.M., and Boone, J.M. (2011). The Essential Physics of Medical Imaging, Lippincott Williams & Wilkins."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1111\/j.1749-6632.2009.04420.x","article-title":"What\u2019s new in neuroimaging methods?","volume":"1156","author":"Bandettini","year":"2009","journal-title":"Ann. N. Y. Acad. Sci."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1148\/radiology.185.3.1438743","article-title":"Intracranial vascular stenosis and occlusion: Evaluation with three-dimensional time-of-flight MR angiography","volume":"185","author":"Heiserman","year":"1992","journal-title":"Radiology"},{"key":"ref_5","unstructured":"Danielsen, E.R., and Ross, B. (2014). Magnetic Resonance Spectroscopy Diagnosis of Neurological Diseases, CRC Press."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Soares, J.M., Marques, P., Alves, V., and Sousa, N. (2013). A hitchhiker\u2019s guide to diffusion tensor imaging. Front. Neurosci., 7.","DOI":"10.3389\/fnins.2013.00031"},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"628","DOI":"10.1097\/00004728-200207000-00027","article-title":"Comparison of 1.5 and 8 Tesla High-Resolution Magnetic Resonance Imaging of Lacunar Infarcts","volume":"26","author":"Chakeres","year":"2002","journal-title":"J. Comput. Assist. Tomogr."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1016\/j.neuroimage.2017.01.067","article-title":"MRI and MRS of the human brain at magnetic fields of 14T to 20T: Technical feasibility, safety, and neuroscience horizons","volume":"168","author":"Budinger","year":"2018","journal-title":"Neuroimage"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"U\u011furbil, K. (2021). Ultrahigh field and ultrahigh resolution fMRI. Curr. Opin. Biomed. Eng., 18.","DOI":"10.1016\/j.cobme.2021.100288"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1111\/jon.12481","article-title":"Clinical Neuroimaging Using 7 T MRI: Challenges and Prospects","volume":"28","author":"Vargas","year":"2017","journal-title":"J. Neuroimaging"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1204","DOI":"10.3174\/ajnr.A4180","article-title":"Ultra-High-Field MR Neuroimaging","volume":"36","author":"Balchandani","year":"2015","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"106366","DOI":"10.1016\/j.yebeh.2019.06.010","article-title":"Epilepsy under the scope of ultra-high field MRI","volume":"121","author":"Rondinoni","year":"2019","journal-title":"Epilepsy Behav."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"20210708","DOI":"10.1259\/bjr.20210708","article-title":"3 T: The good, the bad and the ugly","volume":"95","author":"Graves","year":"2021","journal-title":"Br. J. Radiol."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1097\/RMR.0000000000000202","article-title":"Evolution of UHF Body Imaging in the Human Torso at 7T: Technology, Applications, and Future Directions","volume":"28","author":"Erturk","year":"2019","journal-title":"Top. Magn. Reson. Imaging"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1002\/mrm.10353","article-title":"Transmit SENSE","volume":"49","author":"Katscher","year":"2002","journal-title":"Magn. Reson. Med."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1145","DOI":"10.1002\/nbm.3313","article-title":"Parallel transmission for ultrahigh-field imaging","volume":"29","author":"Padormo","year":"2015","journal-title":"NMR Biomed."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Williams, S.N., McElhinney, P., and Gunamony, S. (2023). Ultra-high field MRI: Parallel-transmit arrays and RF pulse design. Phys. Med. Biol., 68.","DOI":"10.1088\/1361-6560\/aca4b7"},{"key":"ref_18","unstructured":"Jezzard, P. (2019). Relaxation Times and Basic Pulse Sequences. Magnetic Resonance in Medicine, BoD\u2013Books on Demand."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1103\/PhysRev.73.679","article-title":"Relaxation Effects in Nuclear Magnetic Resonance Absorption","volume":"73","author":"Bloembergen","year":"1948","journal-title":"Phys. Rev."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1002\/(SICI)1099-0534(1997)9:5<277::AID-CMR1>3.0.CO;2-W","article-title":"NMR signal reception: Virtual photons and coherent spontaneous emission","volume":"9","author":"Hoult","year":"1997","journal-title":"Concepts Magn. Reson."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1002\/cmr.1820030305","article-title":"Relaxation. Can T2, be longer than T1?","volume":"3","author":"Traficante","year":"1991","journal-title":"Concepts Magn. Reson."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1002\/mrm.21122","article-title":"Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivo","volume":"57","author":"Rooney","year":"2007","journal-title":"Magn. Reson. Med."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1002\/mrm.20946","article-title":"High magnetic field water and metabolite proton T1 and T2 relaxation in rat brain in vivo","volume":"56","author":"Brown","year":"2006","journal-title":"Magn. Reason. Med."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1002\/mrm.20605","article-title":"T1, T2 relaxation and magnetization transfer in tissue at 3T","volume":"54","author":"Stanisz","year":"2005","journal-title":"Magn. Reason. Med."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1118\/1.595535","article-title":"A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1\u2013100 MHz: Dependence on tissue type, NMR frequency, temperature, species, excision, and age","volume":"11","author":"Bottomley","year":"1984","journal-title":"Med. Phys."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1201","DOI":"10.1103\/PhysRev.111.1201","article-title":"Diffusion and Nuclear Spin Relaxation in Water","volume":"111","author":"Simpson","year":"1958","journal-title":"Phys. Rev. B"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"831","DOI":"10.2214\/ajr.149.4.831","article-title":"The biophysical basis of tissue contrast in extracranial MR imaging","volume":"149","author":"Mitchell","year":"1987","journal-title":"Am. J. Roentgenol."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1007\/s10334-017-0659-3","article-title":"T 2 mapping of cerebrospinal fluid: 3 T versus 7 T","volume":"31","author":"Spijkerman","year":"2017","journal-title":"Magn. Reson. Mater. Physics, Biol. Med."},{"key":"ref_29","first-page":"1411","article-title":"Measuring T2 and T2\u2032 in the brain at 1.5T, 3T and 7T using a hybrid gradient echo-spin echo sequence and EPI","volume":"16","author":"Cox","year":"2008","journal-title":"Proc. Intl. Soc. Mag. Reason. Med."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1002\/mrm.22397","article-title":"High-resolution magnetization-prepared 3D-FLAIR imaging at 7.0 Tesla","volume":"64","author":"Visser","year":"2010","journal-title":"Magn. Reason. Med."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/j.neuroimage.2014.10.011","article-title":"FLAIR images at 7 Tesla MRI highlight the ependyma and the outer layers of the cerebral cortex","volume":"104","author":"Fracasso","year":"2015","journal-title":"NeuroImage"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"100025","DOI":"10.1016\/j.ipemt.2024.100025","article-title":"Towards clinical translation of 7 Tesla MRI in the human brain","volume":"9","author":"Keith","year":"2024","journal-title":"IPEM-Translation"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1439","DOI":"10.1148\/rg.2015140289","article-title":"Body MR Imaging: Artifacts, k-Space, and Solutions","volume":"35","author":"Huang","year":"2015","journal-title":"RadioGraphics"},{"key":"ref_34","first-page":"S14","article-title":"Neuroimaging in the Era of Artificial Intelligence: Current Applications","volume":"39","author":"Monsour","year":"2022","journal-title":"Fed. Pract."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.neuroimage.2016.11.033","article-title":"Gradient and shim technologies for ultra high field MRI","volume":"168","author":"Winkler","year":"2016","journal-title":"NeuroImage"},{"key":"ref_36","unstructured":"Blasche, M., and Fischer, D. (2024, September 24). Magnet Homogeneity and Shimming. Siemens Healthineers. Erlangen Ger. White Pap. Siemens Healthc. GmbH, Available online: https:\/\/www.magnetomworld.siemens-healthineers.com\/publications\/whitepapers."},{"key":"ref_37","doi-asserted-by":"crossref","unstructured":"Shokrollahi, P., Drake, J.M., and Goldenberg, A.A. (2017). Quantification of Force and Torque Applied by a High-Field Magnetic Resonance Imaging System on an Ultrasonic Motor for MRI-Guided Robot-Assisted Interventions. Actuators, 6.","DOI":"10.3390\/act6040029"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1097\/RMR.0000000000000204","article-title":"Parallel Transmission for Ultrahigh Field MRI","volume":"28","author":"Deniz","year":"2019","journal-title":"Top. Magn. Reson. Imaging"},{"key":"ref_39","unstructured":"(2024, November 11). MAGNETOM Terra.X Make the Difference. [Internet]. Available online: https:\/\/www.siemens-healthineers.com\/en-us\/magnetic-resonance-imaging\/7t-mri-scanner\/magnetom-terra-x."},{"key":"ref_40","first-page":"2","article-title":"Deep Resolve: Unrivaled Speed in MRI","volume":"89","author":"Behl","year":"2024","journal-title":"MAGNETOM Flash"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"1574","DOI":"10.1002\/mrm.22161","article-title":"Accelerating SENSE using compressed sensing","volume":"62","author":"Liang","year":"2009","journal-title":"Magn. Reson. Med."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1016\/j.pbiomolbio.2004.08.009","article-title":"Physical interactions of static magnetic fields with living tissues","volume":"87","author":"Schenck","year":"2004","journal-title":"Prog. Biophys. Mol. Biol."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1002\/1522-2586(200007)12:1<171::AID-JMRI19>3.0.CO;2-W","article-title":"Potential MR Hazard to Patients With Metallic Heart Valves: The Lenz Effect","volume":"12","author":"Condon","year":"2000","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"1514","DOI":"10.1002\/jmri.29002","article-title":"Managing Patients With Unlabeled Passive Implants on MR Systems Operating Below 1.5 T","volume":"59","author":"Shellock","year":"2023","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1002\/bem.20680","article-title":"A large-scale study on subjective perception of discomfort during 7 and 1.5 T MRI examinations","volume":"32","author":"Heilmaier","year":"2011","journal-title":"Bioelectromagnetics"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1148\/radiol.2019182742","article-title":"Safety Considerations of 7-T MRI in Clinical Practice","volume":"292","author":"Hoff","year":"2019","journal-title":"Radiology"},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1007\/s10334-007-0095-x","article-title":"Subjective acceptance of 7 Tesla MRI for human imaging","volume":"21","author":"Theysohn","year":"2007","journal-title":"Magn. Reson. Mater. Phys. Biol. Med."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1002\/jmri.23904","article-title":"Subject tolerance of 7 T MRI examinations","volume":"38","author":"Versluis","year":"2012","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1097\/RLI.0000000000000035","article-title":"Multicenter Study of Subjective Acceptance During Magnetic Resonance Imaging at 7 and 9.4 T","volume":"49","author":"Rauschenberg","year":"2014","journal-title":"Investig. Radiol."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"684","DOI":"10.1002\/mrm.1091","article-title":"Signal-to-noise ratio and absorbed power as functions of main magnetic field strength, and definition of \u201c90 degrees\u201d RF pulse for the head in the birdcage coil","volume":"45","author":"Collins","year":"2001","journal-title":"Magn. Reason. Med."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1097\/RMR.0b013e3180f612b3","article-title":"High-field-strength magnetic resonance: Potential and limits","volume":"18","author":"Ladd","year":"2007","journal-title":"Top. Magn. Reason. Imaging"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1016\/j.neuroimage.2016.11.031","article-title":"Key clinical benefits of neuroimaging at 7 T","volume":"168","author":"Trattnig","year":"2018","journal-title":"NeuroImage"},{"key":"ref_53","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1002\/epi4.12041","article-title":"Seven tesla MRI improves detection of focal cortical dysplasia in patients with refractory focal epilepsy","volume":"2","author":"Veersema","year":"2017","journal-title":"Epilepsia Open"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"76","DOI":"10.3174\/ajnr.A8083","article-title":"Central Vein Sign in Multiple Sclerosis: A Comparison Study of the Diagnostic Performance of 3T versus 7T MRI","volume":"45","author":"Okromelidze","year":"2023","journal-title":"Am. J. Neuroradiol."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1111\/jon.13173","article-title":"Paramagnetic rim lesions and the central vein sign: Characterizing multiple sclerosis imaging markers","volume":"34","author":"Clarke","year":"2023","journal-title":"J. Neuroimaging"},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1016\/j.mri.2016.11.006","article-title":"7 Tesla MRA for the differentiation between intracranial aneurysms and infundibula","volume":"37","author":"Wermer","year":"2017","journal-title":"Magn. Reson. Imaging"},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1016\/j.inat.2018.02.001","article-title":"Preoperative FMRI associated with decreased mortality and morbidity in brain tumor patients","volume":"13","author":"Vysotski","year":"2018","journal-title":"Interdiscip. Neurosurg."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1002\/mrm.1080","article-title":"Imaging brain function in humans at 7 Tesla","volume":"45","author":"Yacoub","year":"2001","journal-title":"Magn. Reson. Med."},{"key":"ref_59","doi-asserted-by":"crossref","unstructured":"Kreitz, S., Mennecke, A., Konerth, L., R\u00f6sch, J., Nagel, A.M., Laun, F.B., Uder, M., D\u00f6rfler, A., and Hess, A. (2023). 3T vs. 7T fMRI: Capturing early human memory consolidation after motor task utilizing the observed higher functional specificity of 7T. Front. Neurosci., 17.","DOI":"10.3389\/fnins.2023.1215400"},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"2085","DOI":"10.1177\/0271678X231197000","article-title":"Determining the effects of elevated partial pressure of oxygen on hypercapnia-induced cerebrovascular reactivity","volume":"43","author":"Sayin","year":"2023","journal-title":"J. Cereb. Blood Flow Metab."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1177\/1971400915576311","article-title":"Functional Neuroimaging: Fundamental Principles and Clinical Applications","volume":"28","author":"Khanna","year":"2015","journal-title":"Neuroradiol. J."},{"key":"ref_62","doi-asserted-by":"crossref","unstructured":"Agarwal, S., Welker, K.M., Black, D.F., Little, J.T., DeLone, D.R., Messina, S.A., Passe, T.J., Bettegowda, C., and Pillai, J.J. (2023). Detection and Mitigation of Neurovascular Uncoupling in Brain Gliomas. Cancers, 15.","DOI":"10.3390\/cancers15184473"},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"1306","DOI":"10.1161\/01.STR.21.9.1306","article-title":"A simple test to assess cerebrovascular reserve capacity using transcranial Dopper sonography and acetazolamide","volume":"21","author":"Piepgras","year":"1990","journal-title":"Stroke"},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1016\/j.neuroimage.2018.03.047","article-title":"Cerebrovascular reactivity (CVR) MRI with CO2 challenge: A technical review","volume":"187","author":"Liu","year":"2019","journal-title":"NeuroImage"},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/j.nic.2020.09.003","article-title":"The Problem of Neurovascular Uncoupling","volume":"31","author":"Agarwal","year":"2020","journal-title":"Neuroimaging Clin. N. Am."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"2011","DOI":"10.1161\/STROKEAHA.118.021012","article-title":"Magnetic Resonance Imaging\u2013Based Cerebrovascular Reactivity and Hemodynamic Reserve","volume":"49","author":"Fisher","year":"2018","journal-title":"Stroke"},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"936","DOI":"10.1002\/mrm.26190","article-title":"In vivo detection of 2-hydroxyglutarate in brain tumors by optimized point-resolved spectroscopy (PRESS) at 7T","volume":"77","author":"Ganji","year":"2016","journal-title":"Magn. Reson. Med."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1007\/s10334-020-00879-9","article-title":"On the reproducibility of hippocampal MEGA-sLASER GABA MRS at 7T using an optimized analysis pipeline","volume":"34","author":"Pracht","year":"2021","journal-title":"Magn. Reson. Mater. Phys. Biol. Med."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.pnmrs.2023.04.002","article-title":"Recent technical developments and clinical research applications of sodium (23Na) MRI","volume":"138\u2013139","author":"Gast","year":"2023","journal-title":"Prog. Nucl. Magn. Reson. Spectrosc."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"181","DOI":"10.3174\/ajnr.A7404","article-title":"Sodium MRI at 7T for Early Response Evaluation of Intracranial Tumors following Stereotactic Radiotherapy Using the CyberKnife","volume":"43","author":"Huang","year":"2022","journal-title":"Am. J. Neuroradiol."},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"e220127","DOI":"10.1148\/rycan.220127","article-title":"Whole-Brain Intracellular pH Mapping of Gliomas Using High-Resolution 31P MR Spectroscopic Imaging at 7.0 T","volume":"6","author":"Paech","year":"2024","journal-title":"Radiol. Imaging Cancer"},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"788","DOI":"10.2214\/AJR.23.29342","article-title":"Use of a Commercial 7-T MRI Scanner for Clinical Brain Imaging: Indications, Protocols, Challenges, and Solutions\u2014A Single-Center Experience","volume":"221","author":"White","year":"2023","journal-title":"Am. J. Roentgenol."},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"2048","DOI":"10.1038\/s41592-023-02068-7","article-title":"Next-generation MRI scanner designed for ultra-high-resolution human brain imaging at 7 Tesla","volume":"20","author":"Feinberg","year":"2023","journal-title":"Nat. Methods"},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"1811","DOI":"10.3174\/ajnr.A8393","article-title":"Prevalence of Rathke\u2019s Cleft and Other Incidental Pituitary Gland Findings on Contrast-Enhanced 3D Fat-Saturated T1-MPRAGE at 7 Tesla MRI","volume":"45","author":"Mir","year":"2024","journal-title":"Am. J. Neuroradiol."},{"key":"ref_75","first-page":"1","article-title":"Enhancing outcomes in deep brain stimulation: A comparative study of direct targeting using 7T versus 3T MRI","volume":"1","author":"Middlebrooks","year":"2024","journal-title":"J. Neurosurg."},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1186\/s41747-020-00174-1","article-title":"Musculoskeletal MRI at 7 T: Do we need more or is it more than enough?","volume":"4","author":"Aringhieri","year":"2020","journal-title":"Eur. Radiol. Exp."},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"2978","DOI":"10.1002\/mp.12931","article-title":"7T ultra-high field body MR imaging with an 8-channel transmit\/32-channel receive radiofrequency coil array","volume":"45","author":"Rietsch","year":"2018","journal-title":"Med. Phys."}],"container-title":["Bioengineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2306-5354\/11\/12\/1228\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T16:47:12Z","timestamp":1760114832000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2306-5354\/11\/12\/1228"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,5]]},"references-count":77,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["bioengineering11121228"],"URL":"https:\/\/doi.org\/10.3390\/bioengineering11121228","relation":{},"ISSN":["2306-5354"],"issn-type":[{"value":"2306-5354","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,5]]}}}