{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T17:10:36Z","timestamp":1787764236896,"version":"build-2784847793"},"reference-count":45,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2025,4,3]],"date-time":"2025-04-03T00:00:00Z","timestamp":1743638400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Youth Science and Technology Fund Project of China National Machinery Industry Corporation","award":["QNJJ-PY-2023-11"],"award-info":[{"award-number":["QNJJ-PY-2023-11"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Bioengineering"],"abstract":"<jats:p>The interspinous process device (IPD) has emerged as a viable alternative for managing lumbar degenerative pathologies. Nevertheless, limited research exists regarding mechanical failure modes including device failure and spinous process fracture. This study developed a novel IPD (IPD-NEW) and systematically evaluated its biomechanical characteristics through finite element (FE) analysis and in vitro cadaveric biomechanical testing. Six human L1\u2013L5 lumbar specimens were subjected to mechanical testing under four experimental conditions: (1) Intact spine (control); (2) L3\u2013L4 implanted with IPD-NEW; (3) L3\u2013L4 implanted with Wallis device; (4) L3\u2013L4 implanted with Coflex device. Segmental range of motion (ROM) was quantified across all test conditions. A validated L1\u2013L5 finite element model was subsequently employed to assess biomechanical responses under both static and vertical vibration loading regimes. Comparative analysis revealed that IPD-NEW demonstrated comparable segmental ROM to the Wallis device while exhibiting lower rigidity than the Coflex implant. The novel design effectively preserved physiological spinal mobility while enhancing load distribution capacity. IPD-NEW demonstrated notable reductions in facet joint forces, device stress concentrations, and spinous process loading compared to conventional implants, particularly under vibrational loading conditions. These findings suggest that IPD-NEW may mitigate risks associated with facetogenic pain, device failure, and spinous process fracture through optimized load redistribution.<\/jats:p>","DOI":"10.3390\/bioengineering12040384","type":"journal-article","created":{"date-parts":[[2025,4,4]],"date-time":"2025-04-04T06:52:56Z","timestamp":1743749576000},"page":"384","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["A Biomechanical Evaluation of a Novel Interspinous Process Device: In Vitro Flexibility Assessment and Finite Element Analysis"],"prefix":"10.3390","volume":"12","author":[{"given":"Hangkai","family":"Shen","sequence":"first","affiliation":[{"name":"China United Engineering Corporation, First Industrial Design and Research Institute, Hangzhou 310000, China"},{"name":"Biomechanics & Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518000, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chuanguang","family":"Ju","sequence":"additional","affiliation":[{"name":"Yantai Affiliated Hospital, Binzhou Med University, Yantai 264100, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tao","family":"Gao","sequence":"additional","affiliation":[{"name":"China United Engineering Corporation, First Industrial Design and Research Institute, Hangzhou 310000, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3824-1059","authenticated-orcid":false,"given":"Jia","family":"Zhu","sequence":"additional","affiliation":[{"name":"Biomechanics & Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518000, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weiqiang","family":"Liu","sequence":"additional","affiliation":[{"name":"Biomechanics & Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518000, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,4,3]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"462","DOI":"10.3171\/2023.5.SPINE23353","article-title":"Midline lumbar interbody fusion: A review of the surgical technique and outcomes","volume":"39","author":"Alentado","year":"2023","journal-title":"J. Neurosurg. Spine"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"705","DOI":"10.3109\/02688697.2015.1036838","article-title":"Anterior lumbar interbody fusion versus transforaminal lumbar interbody fusion-systematic review and meta-analysis","volume":"29","author":"Phan","year":"2019","journal-title":"Br. J. Neurosurg."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"819","DOI":"10.1016\/j.wneu.2019.02.164","article-title":"Biomechanical Evaluation of Transforaminal Lumbar Interbody Fusion and Oblique Lumbar Interbody Fusion on the Adjacent Segment: A Finite Element Analysis","volume":"126","author":"Wang","year":"2019","journal-title":"World Neurosurg."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1016\/j.wneu.2023.02.023","article-title":"Biomechanical Evaluation of Lateral Lumbar Interbody Fusion with Various Fixation Options for Adjacent Segment Degeneration: A Finite Element Analysis","volume":"173","author":"Lee","year":"2023","journal-title":"World Neurosurg."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1938","DOI":"10.1097\/01.brs.0000137069.88904.03","article-title":"Adjacent segment disease after lumbar or lumbosacral fusion: Review of the literature","volume":"29","author":"Park","year":"2004","journal-title":"Spine"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1007\/s11517-018-1838-8","article-title":"Finite element analysis and design of an interspinous device using topology optimization","volume":"57","author":"Guo","year":"2019","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1007\/s11916-020-0845-2","article-title":"Minimally Invasive Lumbar Decompression and Interspinous Process Device for the Management of Symptomatic Lumbar Spinal Stenosis: A Literature Review","volume":"24","author":"Merkow","year":"2020","journal-title":"Curr. Pain Headache Rep."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"2909","DOI":"10.2147\/JPR.S417319","article-title":"Instrumented Posterior Arthrodesis of the Lumbar Spine: Prospective Study Evaluating Fusion Outcomes in Patients Receiving an Interspinous Fixation Device for the Treatment of Degenerative Spine Diseases","volume":"16","author":"Skoblar","year":"2023","journal-title":"J. Pain Res."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/j.clineuro.2018.06.030","article-title":"Comparative effectiveness and safety of posterior lumbar interbody fusion, Coflex, Wallis, and X-stop for lumbar degenerative diseases: A systematic review and network meta-analysis","volume":"172","author":"Mo","year":"2018","journal-title":"Clin. Neurol. Neurosurg."},{"key":"ref_10","first-page":"45","article-title":"Which is the most effective treatment for lumbar spinal stenosis: Decompression, fusion, or interspinous process device? A Bayesian network meta-analysis","volume":"26","author":"Zhang","year":"2021","journal-title":"J. Orthop. Transl."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.1007\/s00586-008-0657-2","article-title":"Biomechanical effect of different lumbar interspinous implants on flexibility and intradiscal pressure","volume":"17","author":"Wilke","year":"2008","journal-title":"Eur. Spine J."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1112","DOI":"10.1016\/j.wneu.2019.04.051","article-title":"Biomechanical Analysis of Different Lumbar Interspinous Process Devices: A Finite Element Study","volume":"127","author":"Shen","year":"2019","journal-title":"World Neurosurg."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1080\/10255842.2020.1851368","article-title":"Biomechanical analysis of lumbar spine with interbody fusion surgery and U-shaped lumbar interspinous spacers","volume":"24","author":"Yin","year":"2021","journal-title":"Comput. Methods Biomech. Biomed. Engin."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"1333","DOI":"10.1007\/s11517-017-1767-y","article-title":"Biomechanical analysis of a new lumbar interspinous device with optimized topology","volume":"56","author":"Chen","year":"2018","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"2199","DOI":"10.1007\/s00264-013-2006-2","article-title":"Complications in degenerative lumbar disease treated with a dynamic interspinous spacer (Coflex)","volume":"37","author":"Xu","year":"2013","journal-title":"Int. Orthop."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/j.wneu.2015.08.069","article-title":"Paradoxical Radiographic Changes of Coflex Interspinous Device with Minimum 2-Year Follow-Up in Lumbar Spinal Stenosis","volume":"85","author":"Lee","year":"2016","journal-title":"World Neurosurg."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"100162","DOI":"10.1016\/j.wnsx.2023.100162","article-title":"Relationship between lumbar lordosis, pelvic parameters, PI-LL mismatch and outcome after short fusion surgery for lumbar degenerative disease. Literature review, rational and presentation of public study protocol: RELApSE study (registry for evaluation of lumbar arthrodesis sagittal alignEment)","volume":"18","author":"Tartara","year":"2023","journal-title":"World Neurosurg.-X"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"e3214","DOI":"10.1002\/cnm.3214","article-title":"Finite element analysis of a ball-and-socket artificial disc design to suppress excessive loading on facet joints: A comparative study with ProDisc","volume":"35","author":"Choi","year":"2019","journal-title":"Int. J. Numer. Methods Biomed. Eng."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/j.wneu.2021.02.094","article-title":"Posterior Lumbar Interbody Fusion Versus Transforaminal Lumbar Interbody Fusion: Finite Element Analysis of the Vibration Characteristics of Fused Lumbar Spine","volume":"150","author":"Fan","year":"2021","journal-title":"World Neurosurg."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Fan, W., and Guo, L.X. (2021). Prediction of the influence of vertical whole-body vibration on biomechanics of spinal segments after lumbar interbody fusion surgery. Clin. Biomech., 86.","DOI":"10.1016\/j.clinbiomech.2021.105389"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"1326","DOI":"10.1016\/j.jbiomech.2006.05.019","article-title":"Novel model to analyze the effect of a large compressive follower pre-load on range of motions in a lumbar spine","volume":"40","author":"Renner","year":"2007","journal-title":"J. Biomech."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1115\/1.3426225","article-title":"Mechanical-properties of human lumbar spine motion segments. 2. Responses in compression and shear-influence of gross morphology","volume":"101","author":"Berkson","year":"1979","journal-title":"J Biomech. Eng.\u2014T. ASME"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1097\/00007632-199106000-00008","article-title":"Change of disk height, radial disk bulge, and intradiscal pressure from discectomy-an in vitro investigation on human lumbar disks","volume":"16","author":"Brinckmann","year":"1991","journal-title":"Spine"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"106481","DOI":"10.1016\/j.cmpb.2021.106481","article-title":"Comparative biomechanical analysis of rigid vs. flexible fixation devices for the lumbar spine: A geometrically patient-specific poroelastic finite element study","volume":"212","author":"Khalaf","year":"2021","journal-title":"Comput. Methods Programs Biomed."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"2597","DOI":"10.1007\/s12541-014-0632-2","article-title":"Pre-tension effects from tightening the ligature on spinous process fracture risk in interspinous process device implantation","volume":"15","author":"Park","year":"2014","journal-title":"Int. J. Precision Eng. Manuf."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Liu, X., Ma, J., Park, P., Huang, X., Xie, N., and Ye, X. (2017). Biomechanical comparison of multilevel lateral interbody fusion with and without supplementary instrumentation: A three-dimensional finite element study. BMC Musculoskelet Disord, 18.","DOI":"10.1186\/s12891-017-1387-6"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"2000009","DOI":"10.1002\/mats.202000009","article-title":"Simplification of Hyperelastic Constitutive Model and Finite Element Analysis of Thermoplastic Polyurethane Elastomers","volume":"29","author":"Wang","year":"2020","journal-title":"Macromol. Theory Simul."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"863","DOI":"10.1016\/j.spinee.2011.06.015","article-title":"Biomechanical analysis of a novel posterior construct in a transforaminal lumbar interbody fusion model an in vitro study","volume":"11","author":"Sethi","year":"2011","journal-title":"Spine J."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1016\/j.wneu.2021.09.066","article-title":"Fundamentals of Intervertebral Disc Degeneration","volume":"157","author":"Kirnaz","year":"2022","journal-title":"World Neurosurg."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"536","DOI":"10.14245\/ns.2347216.608","article-title":"Finite Element Analysis of Stress Distribution and Range of Motion in Discogenic Back Pain","volume":"21","author":"Cho","year":"2024","journal-title":"Neurospine"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"103952","DOI":"10.1016\/j.medengphy.2023.103952","article-title":"Comparison of the biomechanical effects of lumbar disc degeneration on normal patients and osteoporotic patients: A finite element analysis","volume":"112","author":"Zhang","year":"2023","journal-title":"Med. Eng. Phys."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1871","DOI":"10.1007\/s00198-005-1953-x","article-title":"Factors related to spinal mobility in patients with postmenopausal osteoporosis","volume":"16","author":"Miyakoshi","year":"2005","journal-title":"Osteoporos. Int."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"140","DOI":"10.14444\/7021","article-title":"Variations Among Human Lumbar Spine Segments and Their Relationships to In Vitro Biomechanics: A Retrospective Analysis of 281 Motion Segments From 85 Cadaveric Spines","volume":"14","author":"Sawa","year":"2020","journal-title":"Int. J. Spine Surg."},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Jeong, J.G., Kang, S.W., Jung, G.H., Cho, M.G., Kim, H., Kim, K.T., Kim, D.H., and Hwang, J.M. (2022). Biomechanical Effect of Disc Height on the Components of the Lumbar Column at the Same Axial Load: A Finite-Element Study. J. Healthc. Eng., 7069448.","DOI":"10.1155\/2022\/7069448"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1016\/j.jocn.2021.06.020","article-title":"Age-related degenerative changes and sex-specific differences in osseous anatomy and intervertebral disc height of the thoracolumbar spine","volume":"90","author":"Machino","year":"2021","journal-title":"J. Clin. Neurosci."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"105872","DOI":"10.1016\/j.clinbiomech.2023.105872","article-title":"Biomechanical responses of the human lumbar spine to vertical whole-body vibration in normal and osteoporotic conditions","volume":"102","author":"Fan","year":"2023","journal-title":"Clin. Biomech."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"e3764","DOI":"10.1002\/cnm.3764","article-title":"Prediction of the biomechanical behaviour of the lumbar spine under multi-axis whole-body vibration using a whole-body finite element model","volume":"39","author":"Zhang","year":"2023","journal-title":"Int. J. Numer. Methods Biomed. Eng."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"e3645","DOI":"10.1002\/cnm.3645","article-title":"Biomechanical analysis of lumbar nonfusion dynamic stabilization using a pedicle screw-based dynamic stabilizer or an interspinous process spacer","volume":"38","author":"Fan","year":"2022","journal-title":"Int. J. Numer. Methods Biomed. Eng."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1007\/s10856-019-6320-0","article-title":"Stress analysis of the implants in transforaminal lumbar interbody fusion under static and vibration loadings: A comparison between pedicle screw fixation system with rigid and flexible rods. Journal of materials science","volume":"30","author":"Fan","year":"2019","journal-title":"Mater. Med."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1227\/NEU.0000000000001237","article-title":"Three-year follow-up of the prospective, randomized, controlled trial of coflex interlaminar stabilization vs instrumented fusion in patients with lumbar stenosis","volume":"79","author":"Bae","year":"2016","journal-title":"Neurosurg."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1007\/s10143-012-0394-1","article-title":"Role of lumbar interspinous distraction on the neural elements","volume":"35","author":"Alfieri","year":"2012","journal-title":"Neurosurg. Rev."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"e3498","DOI":"10.1002\/cnm.3498","article-title":"Biomechanical analysis of lumbar fusion with proximal interspinous process device implantation","volume":"37","author":"Shen","year":"2021","journal-title":"Int. J. Numer. Methods Biomed. Eng."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1186\/s12984-024-01522-7","article-title":"The trunk segmental motion complexity and balance performance in challenging seated perturbation among individuals with spinal cord injury","volume":"22","author":"Shan","year":"2025","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Chabarova, O., Selivonec, J., and Menendez Hurtado, A. (2024). Investigation of the Role of Osteoporotic Vertebra Degeneration on the Stability of the Lumbar Spine: In Silico Modelling under Compressive Loading. Bioengineering, 11.","DOI":"10.3390\/bioengineering11050507"},{"key":"ref_45","doi-asserted-by":"crossref","unstructured":"Huang, Z.B., Liu, S., Nie, M.D., Yuan, J.B., Lin, X.M., Chu, X.R., and Shi, Z.C. (2023). Treatment of Lumbar Degenerative Disease with a Novel Interlaminar Screw Elastic Spacer Technique: A Finite Element Analysis. Bioengineering, 10.","DOI":"10.3390\/bioengineering10101204"}],"container-title":["Bioengineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2306-5354\/12\/4\/384\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T17:09:46Z","timestamp":1760029786000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2306-5354\/12\/4\/384"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,3]]},"references-count":45,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2025,4]]}},"alternative-id":["bioengineering12040384"],"URL":"https:\/\/doi.org\/10.3390\/bioengineering12040384","relation":{},"ISSN":["2306-5354"],"issn-type":[{"value":"2306-5354","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,3]]}}}