{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T01:09:06Z","timestamp":1790384946025,"version":"4.1.0"},"reference-count":43,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2025,4,10]],"date-time":"2025-04-10T00:00:00Z","timestamp":1744243200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Bioengineering"],"abstract":"<jats:p>The dental profession has a high prevalence of musculoskeletal disorders because daily working life is characterized by many monotonous and one-sided physical exertions. Inertial measurement unit (IMU)-based motion capture (MoCap) is increasingly utilized for assessing workplace postural risk. However, practical alternatives are needed because it is time-consuming and relatively cost intensive for ergonomists. This study compared two measurement technologies: IMU-based MoCap and a time-effective alternative, two-dimensional (2D) pose estimation. Forty-five dental assistant students (all female) were included (age: 19.56 \u00b1 5.91 years; height: 165.00 \u00b1 6.35 cm; weight: 63.41 \u00b1 13.87 kg; BMI: 21.56 \u00b1 4.63 kg\/m2). A 30 s IMU-based MoCap and image-based pose estimation in the sagittal and frontal planes were performed during a representative experimental task. Data were analyzed using Cohen\u2019s weighted kappa and Bland\u2013Altman plots. There was a significant moderate agreement between the Rapid Upper Limb Assessment (RULA) score from IMU-based MoCap and pose estimation (\u03ba = 0.461, pB = 0.006), but no significant poor agreement (p &gt; 0.05) regarding the body regions of the upper arm, lower arm, wrist, neck, and trunk. These findings indicate that IMU-based MoCap and pose estimation moderately align when assessing the overall RULA score but not for specific body parts. While pose estimation might be useful for quick general posture assessment, it may not be reliable for evaluating joint-level differences, especially in body areas such as the upper extremities. Future research should focus on refining video-based pose estimation for real-time postural risk assessment in the workplace.<\/jats:p>","DOI":"10.3390\/bioengineering12040403","type":"journal-article","created":{"date-parts":[[2025,4,10]],"date-time":"2025-04-10T07:41:51Z","timestamp":1744270911000},"page":"403","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["2D Pose Estimation vs. Inertial Measurement Unit-Based Motion Capture in Ergonomics: Assessing Postural Risk in Dental Assistants"],"prefix":"10.3390","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-0881-6791","authenticated-orcid":false,"given":"Steven","family":"Simon","sequence":"first","affiliation":[{"name":"Department of Sports Science, RPTU University Kaiserslautern-Landau, 67663 Kaiserslautern, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonna","family":"Meining","sequence":"additional","affiliation":[{"name":"Department of Sports Science, RPTU University Kaiserslautern-Landau, 67663 Kaiserslautern, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laura","family":"Laurendi","sequence":"additional","affiliation":[{"name":"Department of Sports Science, RPTU University Kaiserslautern-Landau, 67663 Kaiserslautern, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thorsten","family":"Berkefeld","sequence":"additional","affiliation":[{"name":"Department of Sports Science, RPTU University Kaiserslautern-Landau, 67663 Kaiserslautern, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6822-0697","authenticated-orcid":false,"given":"Jonas","family":"Dully","sequence":"additional","affiliation":[{"name":"Department of Sports Science, RPTU University Kaiserslautern-Landau, 67663 Kaiserslautern, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0378-8481","authenticated-orcid":false,"given":"Carlo","family":"Dindorf","sequence":"additional","affiliation":[{"name":"Department of Sports Science, RPTU University Kaiserslautern-Landau, 67663 Kaiserslautern, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1982-6374","authenticated-orcid":false,"given":"Michael","family":"Fr\u00f6hlich","sequence":"additional","affiliation":[{"name":"Department of Sports Science, RPTU University Kaiserslautern-Landau, 67663 Kaiserslautern, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,4,10]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1111\/j.1601-5037.2009.00395.x","article-title":"A systematic review of musculoskeletal disorders among dental professionals","volume":"7","author":"Hayes","year":"2009","journal-title":"Int. J. Dent. Hyg."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1007\/s13191-014-0364-0","article-title":"Postural assessment of students evaluating the need of ergonomic seat and magnification in dentistry","volume":"14","author":"Dable","year":"2014","journal-title":"J. Ind. Prosthodont. Soc."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"Lietz, J., Ulusoy, N., and Nienhaus, A. (2020). Prevention of musculoskeletal diseases and pain among dental professionals through ergonomic interventions: A systematic literature review. Int. J. Environ. Res. Public Health, 17.","DOI":"10.3390\/ijerph17103482"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"30","DOI":"10.5005\/jp-journals-10005-1229","article-title":"Ergonomics in dentistry","volume":"7","author":"Gupta","year":"2014","journal-title":"Int. J. Clin. Pediatr. Dent."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1016\/S0003-6870(01)00040-0","article-title":"Muscle activity and range of motion during active trunk rotation in a sitting posture","volume":"32","year":"2001","journal-title":"Appl. Ergon."},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Maurer-Grubinger, C., Holzgreve, F., Fraeulin, L., Betz, W., Erbe, C., Brueggmann, D., Wanke, E.M., Nienhaus, A., Groneberg, D.A., and Ohlendorf, D. (2021). Combining ergonomic risk assessment (RULA) with inertial motion capture technology in dentistry\u2014Using the benefits from two worlds. Sensors, 21.","DOI":"10.3390\/s21124077"},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Kee, D. (2022). Systematic comparison of OWAS, RULA, and REBA based on a literature review. Int. J. Environ. Res. Public Health, 19.","DOI":"10.3390\/ijerph19010595"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1007\/s40664-020-00386-7","article-title":"Improved ergonomic risk assessment through the combination of inertial sensors and observational methods exemplified by RULA","volume":"70","author":"Maltry","year":"2020","journal-title":"Zentralblatt F\u00fcr Arbeitsmedizin Arbeitsschutz Und Ergon."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"103140","DOI":"10.1016\/j.ergon.2021.103140","article-title":"Comparison of OWAS, RULA and REBA for assessing potential work-related musculoskeletal disorders","volume":"83","author":"Kee","year":"2021","journal-title":"Int. J. Ind. Ergon."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"103164","DOI":"10.1016\/j.ergon.2021.103164","article-title":"Ergonomic postural assessment using a new open-source human pose estimation technology (OpenPose)","volume":"84","author":"Kim","year":"2021","journal-title":"Int. J. Ind. Ergon."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"102882","DOI":"10.1016\/j.apergo.2019.102882","article-title":"Ergonomics assessment methods used by ergonomics professionals","volume":"81","author":"Lowe","year":"2019","journal-title":"Appl. Ergon."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"566","DOI":"10.1016\/j.apergo.2012.11.008","article-title":"Innovative system for real-time ergonomic feedback in industrial manufacturing","volume":"44","author":"Vignais","year":"2013","journal-title":"Appl. Ergon."},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Holzgreve, F., Fraeulin, L., Betz, W., Erbe, C., Wanke, E.M., Br\u00fcggmann, D., Nienhaus, A., Groneberg, D.A., Maurer-Grubinger, C., and Ohlendorf, D. (2022). A RULA-based comparison of the ergonomic risk of typical working procedures for dentists and dental assistants of general dentistry, endodontology, oral and maxillofacial surgery, and orthodontics. Sensors, 22.","DOI":"10.3390\/s22030805"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Zhao, W., Wang, L., Li, Y., Liu, X., Zhang, Y., Yan, B., and Li, H. (2024). A Multi-Scale and Multi-Stage Human Pose Recognition Method Based on Convolutional Neural Networks for Non-Wearable Ergonomic Evaluation. Processes, 12.","DOI":"10.3390\/pr12112419"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Nowara, R., Holzgreve, F., Golbach, R., Wanke, E.M., Maurer-Grubinger, C., Erbe, C., Brueggmann, D., Nienhaus, A., Groneberg, D.A., and Ohlendorf, D. (2023). Testing the Level of Agreement between Two Methodological Approaches of the Rapid Upper Limb Assessment (RULA) for Occupational Health Practice\u2014An Exemplary Application in the Field of Dentistry. Bioengineering, 10.","DOI":"10.3390\/bioengineering10040477"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1173","DOI":"10.1177\/0018720817723496","article-title":"Errors using observational methods for ergonomics assessment in real practice","volume":"59","year":"2017","journal-title":"Hum. Factors"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"103138","DOI":"10.1016\/j.apergo.2020.103138","article-title":"A novel vision-based real-time method for evaluating postural risk factors associated with musculoskeletal disorders","volume":"87","author":"Li","year":"2020","journal-title":"Appl. Ergon."},{"key":"ref_18","unstructured":"Li, L., and Xu, X. (November, January 28). A deep learning-based RULA method for working posture assessment. Proceedings of the Human Factors and Ergonomics Society Annual Meeting, Washington, DC, USA."},{"key":"ref_19","unstructured":"Blondin, M.J., Fister, I., and Pardalos, P.M. (2025). Machine learning in biomechanics: Key applications and limitations in walking, running and sports movements. Artificial Intelligence, Optimization, and Data Sciences in Sports, Springer Nature."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Baldinger, M., Lippmann, K., and Senner, V. (2024). Artificial intelligence-based motion capture: Current technologies, applications and challenges. Artificial Intelligence in Sports, Movement, and Health, Springer.","DOI":"10.1007\/978-3-031-67256-9_10"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Kapse, S., Wu, R., and Thamsuwan, O. (2024). Addressing ergonomic challenges in agriculture through AI-enabled posture classification. Appl. Sci., 14.","DOI":"10.3390\/app14020525"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1007\/s40664-022-00464-y","article-title":"Pr\u00e4valenz von Muskel-Skelett-Erkrankungen in der Zahnmedizin","volume":"72","author":"Holzgreve","year":"2022","journal-title":"Zentralblatt f\u00fcr Arbeitsmedizin Arbeitsschutz und Ergon."},{"key":"ref_23","first-page":"4","article-title":"Next-generation pose detection with movenet and tensorflow. js","volume":"4","author":"Votel","year":"2021","journal-title":"TensorFlow Blog"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"119","DOI":"10.18280\/ts.390111","article-title":"Comparative analysis of OpenPose, PoseNet, and MoveNet models for pose estimation in mobile devices","volume":"39","author":"Jo","year":"2022","journal-title":"Trait. Du Signal"},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"103147","DOI":"10.1016\/j.ergon.2021.103147","article-title":"In-field instrumented ergonomic risk assessment: Inertial measurement units versus Kinect V2","volume":"84","author":"Humadi","year":"2021","journal-title":"Int. J. Ind. Ergon."},{"key":"ref_26","first-page":"1","article-title":"Xsens MVN: Full 6DOF human motion tracking using miniature inertial sensors","volume":"1","author":"Roetenberg","year":"2009","journal-title":"Xsens Motion Technol. BV Tech. Rep."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"7293","DOI":"10.1109\/ACCESS.2020.3048645","article-title":"Instrumented ergonomic risk assessment using wearable inertial measurement units: Impact of joint angle convention","volume":"9","author":"Humadi","year":"2020","journal-title":"IEEE Access"},{"key":"ref_28","unstructured":"Deutsche Gesetzliche Unfallversicherung (2010). Grunds\u00e4tze f\u00fcr arbeitsmedizinische Vorsorgeuntersuchungen, VBG-Ihre gesetzliche Unfallversicherung, Aufl, Gentner. 5. vollst. neu bearb."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/0003-6870(93)90080-S","article-title":"RULA: A survey method for the investigation of work-related upper limb disorders","volume":"24","author":"McAtamney","year":"1993","journal-title":"Appl. Ergon."},{"key":"ref_30","doi-asserted-by":"crossref","unstructured":"Altman, D.G. (1990). Practical Statistics for Medical Research, Chapman and Hall\/CRC.","DOI":"10.1201\/9780429258589"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1037\/h0028106","article-title":"Large sample standard errors of kappa and weighted kappa","volume":"72","author":"Fleiss","year":"1969","journal-title":"Psychol. Bull."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1149","DOI":"10.3758\/BRM.41.4.1149","article-title":"Statistical power analyses using G* Power 3.1: Tests for correlation and regression analyses","volume":"41","author":"Faul","year":"2009","journal-title":"Behav. Res. Methods"},{"key":"ref_33","unstructured":"Teufl, W. (2021). Validation and Initial Applications of a Magnetometer-Free Inertial Sensor Based Motion Capture System for the Human Lower Body. [Ph.D. Thesis, Technische Universit\u00e4t Kaiserslautern]."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"1533","DOI":"10.1109\/TPAMI.2016.2522398","article-title":"Human pose estimation from video and imus","volume":"38","author":"Rosenhahn","year":"2016","journal-title":"IEEE Trans. Pattern Anal. Mach. Intell."},{"key":"ref_35","unstructured":"Alvarez, H.Y. (2023). Validity of the MoveNet Deep Learning Model for Joint Angle Estimation. [Ph.D. Thesis, San Francisco State University]."},{"key":"ref_36","doi-asserted-by":"crossref","unstructured":"Chen, W., Jiang, Z., Guo, H., and Ni, X. (2020). Fall detection based on key points of human-skeleton using openpose. Symmetry, 12.","DOI":"10.3390\/sym12050744"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"e12995","DOI":"10.7717\/peerj.12995","article-title":"Applications and limitations of current markerless motion capture methods for clinical gait biomechanics","volume":"10","author":"Wade","year":"2022","journal-title":"PeerJ"},{"key":"ref_38","doi-asserted-by":"crossref","unstructured":"Teufl, W., Lorenz, M., Miezal, M., Taetz, B., Fr\u00f6hlich, M., and Bleser, G. (2018). Towards inertial sensor based mobile gait analysis: Event-detection and spatio-temporal parameters. Sensors, 19.","DOI":"10.3390\/s19010038"},{"key":"ref_39","doi-asserted-by":"crossref","unstructured":"Al-Amri, M., Nicholas, K., Button, K., Sparkes, V., Sheeran, L., and Davies, J.L. (2018). Inertial measurement units for clinical movement analysis: Reliability and concurrent validity. Sensors, 18.","DOI":"10.3390\/s18030719"},{"key":"ref_40","doi-asserted-by":"crossref","unstructured":"Ludwig, O., Becker, S., and Fr\u00f6hlich, M. (2022). Einf\u00fchrung in die Ganganalyse. Einf\u00fchrung in die Ganganalyse: Grundlagen, Anwendungsgebiete, Messmethoden, Springer.","DOI":"10.1007\/978-3-662-66235-9"},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1007\/s11517-016-1537-2","article-title":"Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis","volume":"55","author":"Mecheri","year":"2017","journal-title":"Med. Biol. Eng. Comput."},{"key":"ref_42","doi-asserted-by":"crossref","unstructured":"Ellegast, R., Hermanns, I., and Schiefer, C. (2009). Workload assessment in field using the ambulatory CUELA system. Digital Human Modeling: Proceedings of the Second International Conference, ICDHM 2009, Held as Part of HCI International 2009, San Diego, CA, USA, 19\u201324 July 2009, Springer. Proceedings 2.","DOI":"10.1007\/978-3-642-02809-0_24"},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"103757","DOI":"10.1016\/j.apergo.2022.103757","article-title":"K-score: A novel scoring system to quantify fatigue-related ergonomic risk based on joint angle measurements via wearable inertial measurement units","volume":"102","author":"Martinez","year":"2022","journal-title":"Appl. Ergon."}],"container-title":["Bioengineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2306-5354\/12\/4\/403\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T17:12:10Z","timestamp":1760029930000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2306-5354\/12\/4\/403"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,10]]},"references-count":43,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2025,4]]}},"alternative-id":["bioengineering12040403"],"URL":"https:\/\/doi.org\/10.3390\/bioengineering12040403","relation":{},"ISSN":["2306-5354"],"issn-type":[{"value":"2306-5354","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4,10]]}}}