{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T22:33:28Z","timestamp":1788474808651,"version":"build-2803163510"},"reference-count":34,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2025,11,9]],"date-time":"2025-11-09T00:00:00Z","timestamp":1762646400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Bioengineering"],"abstract":"<jats:p>This study presents a comprehensive simulation-based comparative analysis of four parallel robotic mechanisms, each developed to assist patient recovery through adaptive movement control and feedback, particularly for upper and lower limb therapy. Kinematic and dynamic models were developed and implemented in Matlab-Simulink, integrating force control via conventional regulators and real-time interaction with simulated patient-applied forces. The structural differences between spherical, rotational, and universal joints in each kinematic chain variant were evaluated. To systematically determine the most suitable design, a detailed Analytic Hierarchy Process was applied considering performance, precision, stability, and actuator effort. The study emphasizes the advantages of parallel robots in rehabilitation due to their precision, rigidity, and compact design, highlighting the potential of parallel robotic systems in customized and adaptive physical therapy interventions. These insights contribute to the optimal design selection of clinical motor therapy robots.<\/jats:p>","DOI":"10.3390\/bioengineering12111224","type":"journal-article","created":{"date-parts":[[2025,11,10]],"date-time":"2025-11-10T08:57:55Z","timestamp":1762765075000},"page":"1224","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Aspects Concerning Parallel Robots Used in Rehabilitation"],"prefix":"10.3390","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2156-1443","authenticated-orcid":false,"given":"Adrian","family":"Todor","sequence":"first","affiliation":[{"name":"Department of Orthopaedics and Traumatology, \u201cIuliu Ha\u021bieganu\u201d University of Medicine and Pharmacy\u2014Cluj-Napoca, 400012 Cluj-Napoca, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9636-0582","authenticated-orcid":false,"given":"Daniel Vasile","family":"Banyai","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cornel","family":"Brisan","sequence":"additional","affiliation":[{"name":"Department of Mechatronics and Machine Dynamics, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adriana Daniela","family":"Banyai","sequence":"additional","affiliation":[{"name":"Department of Mechatronics and Machine Dynamics, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,11,9]]},"reference":[{"key":"ref_1","unstructured":"World Health Organization (2025, May 13). World Report on Disability. Available online: https:\/\/www.who.int\/health-topics\/disability."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1109\/86.662623","article-title":"Robot-aided neurorehabilitation","volume":"6","author":"Krebs","year":"1998","journal-title":"IEEE Trans. Rehabil. Eng."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1177\/1545968316666957","article-title":"Effects of Robot-Assisted Therapy for the Upper Limb After Stroke","volume":"31","author":"Veerbeek","year":"2017","journal-title":"Neurorehabil. Neural Repair"},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Pons, J.L. (2008). Wearable Robots: Biomechatronic Exoskeletons, John Wiley and Sons.","DOI":"10.1002\/9780470987667"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"106117","DOI":"10.1109\/ACCESS.2022.3210514","article-title":"Wearable Robotics for Impaired Upper-Limb Assistance and Rehabilitation: State of the Art and Future Perspectives","volume":"10","author":"Proietti","year":"2022","journal-title":"IEEE Access"},{"key":"ref_6","doi-asserted-by":"crossref","unstructured":"Banyai, A.D., and Brisan, C. (2024). Robotics in Physical Rehabilitation: Systematic Review. Healthcare, 12.","DOI":"10.20944\/preprints202406.2007.v1"},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Datta, S., Das, A., and Gayen, R.K. (2021, January 24\u201326). Kinematic Analysis of Stewart Platform using MATLAB. Proceedings of the 2021 5th International Conference on Electronics, Materials Engineering & Nano-Technology (IEMENTech), Kolkata, India.","DOI":"10.1109\/IEMENTech53263.2021.9614923"},{"key":"ref_8","doi-asserted-by":"crossref","unstructured":"\u010cier\u0165a\u017esk\u00fd, R., Vargovsk\u00e1, M., and Pivar\u010diov\u00e1, E. (2025). Experimental Innovative Prototype Solution for a Specialized Handling Trolley for Sampling Devices. Machines, 13.","DOI":"10.3390\/machines13090775"},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"1","DOI":"10.2478\/msr-2019-0001","article-title":"Machine Vision System Measuring the Trajectory of Upper Limb Motion Applying the Matlab Software","volume":"19","author":"Cyganiuk","year":"2019","journal-title":"Meas. Sci. Rev."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"526","DOI":"10.1016\/j.proeng.2017.02.256","article-title":"A Plastic Strain and Stress Analysis of Bending and Torsion Fatigue Specimens in the Low-cycle Fatigue Region Using the Finite Element Methods","volume":"177","author":"Kopas","year":"2017","journal-title":"Procedia Eng."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1016\/j.rcim.2012.06.001","article-title":"Structural design and kinematics of a new parallel reconfigurable robot","volume":"29","author":"Plitea","year":"2013","journal-title":"Robot. Comput.-Integr. Manuf."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"954","DOI":"10.1109\/TRA.2003.819603","article-title":"Workspace analysis and optimal design of a 3-leg 6-DOF parallel platform mechanism","volume":"19","author":"Monsarrat","year":"2003","journal-title":"IEEE Trans. Robot. Autom."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1016\/j.mechmachtheory.2014.02.017","article-title":"Kinetostatic analysis of a novel 6-DoF 3UPS parallel manipulator with multi-fingers","volume":"78","author":"Lu","year":"2014","journal-title":"Mech. Mach. Theory"},{"key":"ref_14","unstructured":"Merlet, J.P. (2006). Parallel Robots, Springer."},{"key":"ref_15","unstructured":"Moosavian, S.A.A., Nazari, A.A., and Hasani, A. (2011, January 17\u201319). Kinematics and workspace analysis of a novel 3-DOF spatial parallel robot. Proceedings of the 19th Iranian Conference on Electrical Engineering, Tehran, Iran. Available online: https:\/\/ieeexplore.ieee.org\/document\/5955449."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"1018","DOI":"10.1016\/j.robot.2009.07.017","article-title":"Kinematic design optimization of a parallel ankle rehabilitation robot using modified genetic algorithm","volume":"57","author":"Jamwal","year":"2009","journal-title":"Robot. Auton. Syst."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Tucan, P., Pisla, D., Vaida, C., and Carbone, G. (2019). Risk-based assessment engineering of a parallel robot used in post-stroke upper limb rehabilitation. Sustainability, 11.","DOI":"10.3390\/su11102893"},{"key":"ref_18","unstructured":"Vaida, C., Carbone, G., Major, K., Major, Z., Plitea, N., and Pisla, D. (2017). On human\u2013robot interaction modalities in the upper limb rehabilitation after stroke. Acta Tech. Napoc. Ser. Appl. Math. Mech. Eng., 60, Available online: https:\/\/atna-mam.utcluj.ro\/index.php\/Acta\/article\/view\/838."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1186\/s12984-021-00845-z","article-title":"State of the art in parallel ankle rehabilitation robot: A systematic review","volume":"18","author":"Dong","year":"2021","journal-title":"J. Neuroeng. Rehabil."},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Wang, Y., and Xu, Q. (2021). Design and testing of a soft parallel robot based on pneumatic artificial muscles for wrist rehabilitation. Sci. Rep., 11.","DOI":"10.1038\/s41598-020-80411-0"},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Doroftei, I., Oprisan, C., Pisla, D., and Lovasz, E. (2018). Preliminary design for a spherical parallel robot for shoulder rehabilitation. New Advances in Mechanism and Machine Science, Springer.","DOI":"10.1007\/978-3-319-79111-1"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"051007","DOI":"10.1115\/1.4046511","article-title":"Mechanical design and performance analysis of a novel parallel robot for ankle rehabilitation","volume":"12","author":"Li","year":"2020","journal-title":"J. Mech. Robot."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"1687814017718112","DOI":"10.1177\/1687814017718112","article-title":"An ankle rehabilitation robot based on 3-RRS spherical parallel mechanism","volume":"9","author":"Du","year":"2017","journal-title":"Adv. Mech. Eng."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"1433","DOI":"10.1109\/TASE.2014.2331241","article-title":"Three-stage design analysis and multicriteria optimization of a parallel ankle rehabilitation robot using genetic algorithm","volume":"12","author":"Jamwal","year":"2015","journal-title":"IEEE Trans. Autom. Sci. Eng."},{"key":"ref_25","unstructured":"Jamwal, P.K., Xie, S.Q., Aw, K.C., and Tsoi, Y.H. (2009). Multi criteria optimal design of cable driven ankle rehabilitation robot. Mobile Robots\u2014State of the Art in Land, Sea, Air, and Collaborative Missions, InTech."},{"key":"ref_26","first-page":"9","article-title":"Multi-criteria optimum design of manipulators","volume":"53","author":"Ceccarelli","year":"2005","journal-title":"Bull. Pol. Acad. Sci. Techincal Sci."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"060801","DOI":"10.1115\/1.4056919","article-title":"Energy-efficient actuator design principles for robotic leg prostheses and exoskeletons: A review of series elasticity and backdrivability","volume":"18","author":"Laschowski","year":"2023","journal-title":"J. Comput. Nonlinear Dynam."},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Silva, D., Garrido, J., and Riveiro, E. (2022). Stewart Platform Motion Control Automation with Industrial Resources to Perform Cycloidal and Oceanic Wave Trajectories. Machines, 10.","DOI":"10.3390\/machines10080711"},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Bingul, Z., and Karah, O. (2012). Dynamic Modeling and Simulation of Stewart Platform, InTech.","DOI":"10.5772\/32470"},{"key":"ref_30","first-page":"83","article-title":"Decision making with the analytic hierarchy process","volume":"1","author":"Saaty","year":"2008","journal-title":"Int. J. Serv. Sci."},{"key":"ref_31","doi-asserted-by":"crossref","unstructured":"Saaty, T.L. (1980). The Analytic Hierarchy Process: Planning, Priority Setting, Resource Allocation, McGraw Hill.","DOI":"10.21236\/ADA214804"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s11518-006-0179-6","article-title":"Making and validating complex decisions with the AHP\/ANP","volume":"14","author":"Saaty","year":"2005","journal-title":"J. Syst. Sci. Syst. Eng."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1016\/j.ins.2019.08.042","article-title":"On the transitivity and consistency approximated thresholds of some consistency indices for pairwise comparison matrices","volume":"507","author":"Amenta","year":"2020","journal-title":"Inf. Sci."},{"key":"ref_34","doi-asserted-by":"crossref","unstructured":"Abarca, V.E., and Elias, D.A. (2024). Modeling and Simulation of a 2SPU-RU Parallel Mechanism for a Prosthetic Ankle with Three Degrees of Freedom. Inventions, 9.","DOI":"10.3390\/inventions9040071"}],"container-title":["Bioengineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2306-5354\/12\/11\/1224\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,10]],"date-time":"2025-11-10T09:46:37Z","timestamp":1762767997000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2306-5354\/12\/11\/1224"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,9]]},"references-count":34,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2025,11]]}},"alternative-id":["bioengineering12111224"],"URL":"https:\/\/doi.org\/10.3390\/bioengineering12111224","relation":{},"ISSN":["2306-5354"],"issn-type":[{"value":"2306-5354","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,9]]}}}