{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T04:59:03Z","timestamp":1785560343062,"version":"3.56.0"},"reference-count":31,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T00:00:00Z","timestamp":1785369600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"crossref","award":["NIH R01EB036127"],"award-info":[{"award-number":["NIH R01EB036127"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"crossref","award":["NIH R01HL171515"],"award-info":[{"award-number":["NIH R01HL171515"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"crossref","award":["NIH R01HL173035"],"award-info":[{"award-number":["NIH R01HL173035"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Bioengineering"],"abstract":"<jats:p>A high-density posterior cushion coil (HDPCC) can improve the SNR in pediatric MRI by conforming to the body and minimizing distance to the imaged volume when compared to a conventional rigid built-in table coil array. Posterior coil arrays built into MRI tables are mainstays but provide suboptimal performance in pediatric imaging due to their distance from the imaged volume and lower coil density. Our goal is to improve pediatric MRI by constructing a prototype 30-channel high-density posterior cushion coil (HDPCC) incorporated into a padded cushion. Twenty-five pediatric patients were scanned with the HDPCC, and twenty-five pediatric controls served as the comparison group using standard coils. Two radiologists graded image quality on a 5-point scale. SNR was measured in the right paraspinal musculature and the liver. All images obtained with the HDPCC were diagnostic (mean score 4.13\/5). SNR in the superficial tissues of the paraspinal musculature was 34% higher with the HDPCC than with standard coils, while SNR in the deeper tissues of the liver was statistically similar between the two coils. HDPCC yields improved the signal-to-noise ratio in phantoms and pediatric study participants by conforming to the body.<\/jats:p>","DOI":"10.3390\/bioengineering13080881","type":"journal-article","created":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T09:32:13Z","timestamp":1785403933000},"page":"881","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Improved SNR and Image Quality of Pediatric MRI with a Shape Conforming High-Density Posterior Cushion Coil"],"prefix":"10.3390","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6951-1894","authenticated-orcid":false,"given":"Terrence","family":"Jao","sequence":"first","affiliation":[{"name":"Department of Radiology, Stanford University, 300 Pasteur Ave., Stanford, CA 94305, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Praveen","family":"Jayapal","sequence":"additional","affiliation":[{"name":"Department of Radiology, Stanford University, 300 Pasteur Ave., Stanford, CA 94305, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2707-6000","authenticated-orcid":false,"given":"Jana","family":"Vincent","sequence":"additional","affiliation":[{"name":"General Electric Healthcare, Aurora, OH 44202, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Pauly","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Stanford University, Stanford, CA 94305, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ceara","family":"Stack","sequence":"additional","affiliation":[{"name":"General Electric Healthcare, Aurora, OH 44202, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Victor","family":"Taracila","sequence":"additional","affiliation":[{"name":"General Electric Healthcare, Aurora, OH 44202, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1625-9709","authenticated-orcid":false,"given":"Fraser","family":"Robb","sequence":"additional","affiliation":[{"name":"General Electric Healthcare, Aurora, OH 44202, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Grafendorfer","sequence":"additional","affiliation":[{"name":"General Electric Healthcare, Aurora, OH 44202, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yun Jeong","family":"Stickle","sequence":"additional","affiliation":[{"name":"General Electric Healthcare, Aurora, OH 44202, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark","family":"Giancola","sequence":"additional","affiliation":[{"name":"General Electric Healthcare, Aurora, OH 44202, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Clyve Konrad","family":"Follante","sequence":"additional","affiliation":[{"name":"General Electric Healthcare, Aurora, OH 44202, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Greig","family":"Scott","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, Stanford University, Stanford, CA 94305, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1999-6595","authenticated-orcid":false,"given":"Shreyas","family":"Vasanawala","sequence":"additional","affiliation":[{"name":"Department of Radiology, Stanford University, 300 Pasteur Ave., Stanford, CA 94305, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ali B.","family":"Syed","sequence":"additional","affiliation":[{"name":"Department of Radiology, Stanford University, 300 Pasteur Ave., Stanford, CA 94305, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,7,30]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1007\/s00247-011-2103-6","article-title":"Advances in pediatric body MRI","volume":"41","author":"Vasanawala","year":"2011","journal-title":"Pediatr. Radiol."},{"key":"ref_2","first-page":"1270","article-title":"Pediatric Magnetic Resonance Imaging: Faster Is Better","volume":"53","author":"Bedoya","year":"2023","journal-title":"Pediatr. Radiol."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1016\/j.ejrad.2008.05.019","article-title":"3 T MRI in Paediatrics: Challenges and Clinical Applications","volume":"68","author":"Dagia","year":"2008","journal-title":"Eur. J. Radiol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"794","DOI":"10.1002\/mrm.26462","article-title":"A dedicated neonatal brain imaging system","volume":"78","author":"Hughes","year":"2017","journal-title":"Magn. Reson. Med."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1777","DOI":"10.1002\/mrm.22961","article-title":"Size-optimized 32-channel brain arrays for 3 T pediatric imaging","volume":"66","author":"Keil","year":"2011","journal-title":"Magn. Reson. Med."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"e3944","DOI":"10.1002\/nbm.3944","article-title":"Size-adaptable 13-channel receive array for brain MRI in human neonates at 3 T","volume":"31","author":"Foias","year":"2018","journal-title":"NMR Biomed."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"e4928","DOI":"10.1002\/nbm.4928","article-title":"A radiofrequency coil for infants and toddlers","volume":"36","author":"Gilbert","year":"2023","journal-title":"NMR Biomed."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"2771","DOI":"10.1002\/mrm.70011","article-title":"A Size-Adaptive RF Coil for MRI of the Pediatric Human Brain at 7 T","volume":"94","author":"Yazdanbakhsh","year":"2025","journal-title":"Magn. Reson. Med."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1109\/JERM.2021.3136090","article-title":"Towards Brain MRI Adaptable to Head Size: Bowing RF Coil Phased Arrays","volume":"6","author":"Mathieu","year":"2022","journal-title":"IEEE J. Electromagn. RF Microw. Med. Biol."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1007\/s10334-021-00988-z","article-title":"Towards an Integrated Neonatal Brain and Cardiac Examination Capability at 7 T: Electromagnetic Field Simulations and Early Phantom Experiments Using an 8-Channel Dipole Array","volume":"35","author":"Malik","year":"2022","journal-title":"Magn. Reson. Mater. Phys. Biol. Med."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"3659","DOI":"10.1109\/TBME.2021.3082149","article-title":"Simultaneous Head and Spine MR Imaging in Children Using a Dedicated Multichannel Receiver System at 3T","volume":"68","author":"Li","year":"2021","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1773","DOI":"10.1002\/mrm.28791","article-title":"A Size-Adaptive 32-Channel Array Coil for Awake Infant Neuroimaging at 3 Tesla MRI","volume":"86","author":"Ghotra","year":"2021","journal-title":"Magn. Reson. Med."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"2186","DOI":"10.1002\/mrm.30428","article-title":"Adaptable, Wearable, and Stretchable Coils: A Review","volume":"93","author":"Ramesh","year":"2025","journal-title":"Magn. Reson. Med."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1002\/mrm.26399","article-title":"Materials and methods for higher performance screen-printed flexible MRI receive coils","volume":"78","author":"Corea","year":"2017","journal-title":"Magn. Reson. Med."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"2200647","DOI":"10.1002\/admt.202200647","article-title":"Additive Manufacturing of Subject-Conformal Receive Coils for Magnetic Resonance Imaging","volume":"7","author":"Vanduffel","year":"2022","journal-title":"Adv. Mater. Technol."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Gopalan, K., Maravilla, J., Mendelsohn, J., Arias, A.C., and Lustig, M. (2021, January 9\u201313). Vacuum Formed Coils for Magnetic Resonance Imaging. Proceedings of the 2021 International Conference on Electromagnetics in Advanced Applications (ICEAA), Honolulu, HI, USA.","DOI":"10.1109\/ICEAA52647.2021.9539783"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"2635","DOI":"10.1038\/s41598-021-81833-0","article-title":"Custom, Spray Coated Receive Coils for Magnetic Resonance Imaging","volume":"11","author":"Zamarayeva","year":"2021","journal-title":"Sci. Rep."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"3406","DOI":"10.1002\/mrm.27637","article-title":"Size-Adaptable \u201cTrellis\u201d Structure for Tailored MRI Coil Arrays","volume":"81","author":"Zhang","year":"2019","journal-title":"Magn. Reson. Med."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1015","DOI":"10.1002\/mrm.25999","article-title":"A Semiflexible 64-Channel Receive-Only Phased Array for Pediatric Body MRI at 3T","volume":"76","author":"Zhang","year":"2016","journal-title":"Magn. Reson. Med."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/j.zemedi.2023.05.002","article-title":"A Modular System of Flexible Receive-Only Coil Arrays for 3 T Magnetic Resonance Imaging","volume":"35","author":"Nohava","year":"2025","journal-title":"Z. Med. Phys."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"10839","DOI":"10.1038\/ncomms10839","article-title":"Screen-printed flexible MRI receive coils","volume":"7","author":"Corea","year":"2016","journal-title":"Nat. Commun."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1148\/radiol.2019181883","article-title":"Evaluation of a Flexible 12-Channel Screen-printed Pediatric MRI Coil","volume":"291","author":"Winkler","year":"2019","journal-title":"Radiology"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1109\/TMI.2009.2036996","article-title":"An MRI Receiver Coil Produced by Inkjet Printing Directly on to a Flexible Substrate","volume":"29","author":"Mager","year":"2010","journal-title":"IEEE Trans. Med. Imaging"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"2655","DOI":"10.1002\/mrm.30456","article-title":"A 60-channel high-density flexible receive array for pediatric abdominal MRI","volume":"93","author":"Lee","year":"2025","journal-title":"Magn. Reson. Med."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1439","DOI":"10.1002\/mrm.20713","article-title":"Image reconstruction in SNR units: A general method for SNR measurement","volume":"54","author":"Kellman","year":"2005","journal-title":"Magn. Reson. Med."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1002\/jmri.20969","article-title":"Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters","volume":"26","author":"Dietrich","year":"2007","journal-title":"J. Magn. Reson. Imaging"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1348\/000711006X126600","article-title":"Computing inter-rater reliability and its variance in the presence of high agreement","volume":"61","author":"Gwet","year":"2008","journal-title":"Br. J. Math. Stat. Psychol."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1002\/mrm.1910160203","article-title":"The NMR phased array","volume":"16","author":"Roemer","year":"1990","journal-title":"Magn. Reson. Med."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1002\/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S","article-title":"SENSE: Sensitivity encoding for fast MRI","volume":"42","author":"Pruessmann","year":"1999","journal-title":"Magn. Reson. Med."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.1002\/mrm.10171","article-title":"Generalized autocalibrating partially parallel acquisitions (GRAPPA)","volume":"47","author":"Griswold","year":"2002","journal-title":"Magn. Reson. Med."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"990","DOI":"10.1002\/mrm.24751","article-title":"ESPIRiT\u2014An Eigenvalue Approach to Autocalibrating Parallel MRI: Where SENSE meets GRAPPA","volume":"71","author":"Uecker","year":"2014","journal-title":"Magn. Reson. Med."}],"container-title":["Bioengineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2306-5354\/13\/8\/881\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T04:28:48Z","timestamp":1785558528000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2306-5354\/13\/8\/881"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,30]]},"references-count":31,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2026,8]]}},"alternative-id":["bioengineering13080881"],"URL":"https:\/\/doi.org\/10.3390\/bioengineering13080881","relation":{},"ISSN":["2306-5354"],"issn-type":[{"value":"2306-5354","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,30]]}}}