{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T10:18:14Z","timestamp":1787739494254,"version":"build-2784847793"},"reference-count":45,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T00:00:00Z","timestamp":1787702400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100012166","name":"National Key R&D Program of China","doi-asserted-by":"publisher","award":["2024YFC3406302"],"award-info":[{"award-number":["2024YFC3406302"]}],"id":[{"id":"10.13039\/501100012166","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Bioengineering"],"abstract":"<jats:p>Retinal responses to ultrasound depend on carrier frequency, but whether a constrained tissue-to-neuron model can predict this dependence on a common published response scale remains unclear. We developed an acoustic-radiation-force (ARF) modelling workflow that couples an effective tissue-scale stress proxy to a stochastic Hodgkin\u2013Huxley retinal ganglion cell population. One non-negative affine observation model, shared across frequencies, linked raw simulated spike counts to the published three-frequency ex vivo RGC response scale without frequency-specific rescaling. In a nested leave-one-frequency-out model-selection assessment, the workflow achieved an overall Q2 of 0.915 and an RMSE of 0.0752 across 25 held-out observations. Mean-response transfer remained strong across frequencies, although probabilistic calibration was weakest at 1.9 MHz. An in-sample fixed-map sensitivity analysis using moment-matched log-normal, Gamma, and Weibull thresholds yielded overall RMSEs of 0.0434\u20130.0461 and preserved positive overall K-ablation NLPD differences of 0.219\u20130.238, with the effect concentrated at 43 MHz. These results show that shared-scale modelling captures the main cross-frequency response structure and that a high-threshold inhibitory functional component improves the description of high-intensity rolloff. Within the published three-frequency dataset, the workflow provides a reproducible benchmark for targeted comparisons of retinal ultrasound mechanisms.<\/jats:p>","DOI":"10.3390\/bioengineering13090979","type":"journal-article","created":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T09:05:46Z","timestamp":1787735146000},"page":"979","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Shared-Scale Predictive Benchmarking of an Acoustic-Radiation-Force Model for Frequency-Dependent Retinal Ganglion Cell Responses"],"prefix":"10.3390","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-1269-3971","authenticated-orcid":false,"given":"Bingao","family":"Zhang","sequence":"first","affiliation":[{"name":"The Key Laboratory for the Physics and Chemistry of Nanodevices, Institute of Physical Electronics, Department of Electronics, Peking University, Beijing 100871, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9567-5980","authenticated-orcid":false,"given":"Shengyong","family":"Xu","sequence":"additional","affiliation":[{"name":"The Key Laboratory for the Physics and Chemistry of Nanodevices, Institute of Physical Electronics, Department of Electronics, Peking University, Beijing 100871, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,8,26]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1016\/j.ophtha.2011.09.028","article-title":"Interim results from the international trial of Second Sight\u2019s visual prosthesis","volume":"119","author":"Humayun","year":"2012","journal-title":"Ophthalmology"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1038\/s41467-022-28125-x","article-title":"Simultaneous perception of prosthetic and natural vision in AMD patients","volume":"13","author":"Palanker","year":"2022","journal-title":"Nat. Commun."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1489","DOI":"10.1098\/rspb.2010.1747","article-title":"Subretinal electronic chips allow blind patients to read letters and combine them to words","volume":"278","author":"Zrenner","year":"2011","journal-title":"Proc. R. Soc. B"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"026006","DOI":"10.1088\/1741-2560\/9\/2\/026006","article-title":"Towards multifocal ultrasonic neural stimulation II: Design considerations for an acoustic retinal prosthesis","volume":"9","author":"Naor","year":"2012","journal-title":"J. Neural Eng."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"9829316","DOI":"10.34133\/2022\/9829316","article-title":"Noninvasive ultrasound retinal stimulation for vision restoration at high spatiotemporal resolution","volume":"2022","author":"Qian","year":"2022","journal-title":"BME Front."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"046012","DOI":"10.1088\/1741-2552\/ac7d75","article-title":"Low-frequency, low-intensity ultrasound modulates light responsiveness of mouse retinal ganglion cells","volume":"19","author":"Zhuo","year":"2022","journal-title":"J. Neural Eng."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Badadhe, J.D., Roh, H., Lee, B.C., Kim, J.H., and Im, M. (2022). Ultrasound stimulation for non-invasive visual prostheses. Front. Cell. Neurosci., 16.","DOI":"10.3389\/fncel.2022.971148"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1605","DOI":"10.1109\/TNSRE.2017.2682923","article-title":"Simulation study of an ultrasound retinal prosthesis with a novel contact-lens array for noninvasive retinal stimulation","volume":"25","author":"Gao","year":"2017","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Yu, Y., Zhang, Z., Cai, F., Su, M., Jiang, Q., Zhou, Q., Humayun, M.S., Qiu, W., and Zheng, H. (2019). A novel racing array transducer for noninvasive ultrasonic retinal stimulation: A simulation study. Sensors, 19.","DOI":"10.3390\/s19081825"},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Tyler, W.J., Tufail, Y., Finsterwald, M., Tauchmann, M.L., Olson, E.J., and Majestic, C. (2008). Remote excitation of neuronal circuits using low-intensity, low-frequency ultrasound. PLoS ONE, 3.","DOI":"10.1371\/journal.pone.0003511"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1016\/j.ultrasmedbio.2012.09.009","article-title":"Effective parameters for ultrasound-induced in vivo neurostimulation","volume":"39","author":"King","year":"2013","journal-title":"Ultrasound Med. Biol."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"1509","DOI":"10.1016\/j.ultrasmedbio.2018.12.015","article-title":"Ultrasound neuromodulation: A review of results, mechanisms and safety","volume":"45","author":"Blackmore","year":"2019","journal-title":"Ultrasound Med. Biol."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1209","DOI":"10.1016\/j.brs.2018.08.013","article-title":"Low-intensity ultrasound neuromodulation: An overview of mechanisms and emerging human applications","volume":"11","author":"Fomenko","year":"2018","journal-title":"Brain Stimul."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"6251","DOI":"10.1523\/JNEUROSCI.2394-18.2019","article-title":"Radiation force as a physical mechanism for ultrasonic neurostimulation of the ex vivo retina","volume":"39","author":"Menz","year":"2019","journal-title":"J. Neurosci."},{"key":"ref_15","first-page":"011004","article-title":"Intramembrane cavitation as a predictive bio-piezoelectric mechanism for ultrasonic brain stimulation","volume":"4","author":"Plaksin","year":"2014","journal-title":"Phys. Rev. X"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"ENEURO.0136-15.2016","DOI":"10.1523\/ENEURO.0136-15.2016","article-title":"Cell-type-selective effects of intramembrane cavitation as a unifying theoretical framework for ultrasonic neuromodulation","volume":"3","author":"Plaksin","year":"2016","journal-title":"eNeuro"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"046007","DOI":"10.1088\/1741-2552\/ab1685","article-title":"Understanding ultrasound neuromodulation using a computationally efficient and interpretable model of intramembrane cavitation","volume":"16","author":"Lemaire","year":"2019","journal-title":"J. Neural Eng."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1016\/0301-5629(94)90102-3","article-title":"Acoustic velocity and attenuation of eye tissues at 20 MHz","volume":"20","author":"Thijssen","year":"1994","journal-title":"Ultrasound Med. Biol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1038\/nature14013","article-title":"Physical mechanism for gating and mechanosensitivity of the human TRAAK K+ channel","volume":"516","author":"Brohawn","year":"2014","journal-title":"Nature"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"3142","DOI":"10.1038\/s41467-024-47208-5","article-title":"Tension activation of mechanosensitive two-pore domain K+ channels TRAAK, TREK-1, and TREK-2","volume":"15","author":"Sorum","year":"2024","journal-title":"Nat. Commun."},{"key":"ref_21","first-page":"3075","article-title":"Molecular force transduction by ion channels: Diversity and unifying principles","volume":"125","author":"Sukharev","year":"2012","journal-title":"J. Cell Sci."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"24170","DOI":"10.1038\/srep24170","article-title":"Ultrasound modulates ion channel currents","volume":"6","author":"Kubanek","year":"2016","journal-title":"Sci. Rep."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"46085","DOI":"10.1038\/srep46085","article-title":"Expression and localisation of two-pore domain (K2P) background leak potassium ion channels in the mouse retina","volume":"7","author":"Hughes","year":"2017","journal-title":"Sci. Rep."},{"key":"ref_24","first-page":"924","article-title":"Elevated expression of TREK\u2013TRAAK K2P channels in the retina of adult rd1 mice","volume":"12","author":"Zhang","year":"2019","journal-title":"Int. J. Ophthalmol."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"135008","DOI":"10.1088\/1361-6560\/acdbb5","article-title":"Acoustic radiation force for analyzing the mechanical stress in ultrasound neuromodulation","volume":"68","author":"Kim","year":"2023","journal-title":"Phys. Med. Biol."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"500","DOI":"10.1113\/jphysiol.1952.sp004764","article-title":"A quantitative description of membrane current and its application to conduction and excitation in nerve","volume":"117","author":"Hodgkin","year":"1952","journal-title":"J. Physiol."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1038\/nrn3687","article-title":"The log-dynamic brain: How skewed distributions affect network operations","volume":"15","author":"Mizuseki","year":"2014","journal-title":"Nat. Rev. Neurosci."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"e12088","DOI":"10.7554\/eLife.12088","article-title":"Mechanical sensitivity of Piezo1 ion channels can be tuned by cellular membrane tension","volume":"4","author":"Lewis","year":"2015","journal-title":"eLife"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1948","DOI":"10.1152\/jn.1997.78.4.1948","article-title":"Mechanisms by which cell geometry controls repetitive impulse firing in retinal ganglion cells","volume":"78","author":"Fohlmeister","year":"1997","journal-title":"J. Neurophysiol."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/S0306-4522(01)00344-X","article-title":"Fluctuating synaptic conductances recreate in vivo-like activity in neocortical neurons","volume":"107","author":"Destexhe","year":"2001","journal-title":"Neuroscience"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"2057","DOI":"10.1162\/089976602320264015","article-title":"Dynamics of the firing probability of noisy integrate-and-fire neurons","volume":"14","author":"Fourcaud","year":"2002","journal-title":"Neural Comput."},{"key":"ref_32","unstructured":"U.S. Food and Drug Administration (2026, August 18). Marketing Clearance of Diagnostic Ultrasound Systems and Transducers: Guidance for Industry and Food and Drug Administration Staff. Final Guidance, Available online: https:\/\/www.fda.gov\/regulatory-information\/search-fda-guidance-documents\/marketing-clearance-diagnostic-ultrasound-systems-and-transducers."},{"key":"ref_33","unstructured":"Health Canada (2026, August 18). Device Licence Applications for Diagnostic Ultrasound Systems and Transducers: Notice to Industry, Available online: https:\/\/www.canada.ca\/en\/health-canada\/services\/drugs-health-products\/medical-devices\/application-information\/guidance-documents\/device-licence-applications-diagnostic-ultrasound-systems-transducers-notice-industry.html."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1016\/j.ultrasmedbio.2016.09.021","article-title":"Quantification of temperature rise within the lens of the porcine eye caused by ultrasound insonation","volume":"43","author":"King","year":"2017","journal-title":"Ultrasound Med. Biol."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"082902","DOI":"10.1118\/1.4812423","article-title":"Influence of the pressure field distribution in transcranial ultrasonic neurostimulation","volume":"40","author":"Younan","year":"2013","journal-title":"Med. Phys."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1152\/jn.00458.2009","article-title":"Interneuron circuits tune inhibition in retinal bipolar cells","volume":"103","author":"Eggers","year":"2010","journal-title":"J. Neurophysiol."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1167\/iovs.12-10773","article-title":"Effect of ultrasound radiation force on the choroid","volume":"54","author":"Silverman","year":"2013","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"1439","DOI":"10.1016\/j.brs.2019.07.015","article-title":"Reversible neuroinhibition by focused ultrasound is mediated by a thermal mechanism","volume":"12","author":"Darrow","year":"2019","journal-title":"Brain Stimul."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"e2006980118","DOI":"10.1073\/pnas.2006980118","article-title":"Ultrasound activates mechanosensitive TRAAK K+ channels through the lipid membrane","volume":"118","author":"Sorum","year":"2021","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"5487","DOI":"10.1113\/jphysiol.2008.156224","article-title":"Distinct expressions of contrast gain control in parallel synaptic pathways converging on a retinal ganglion cell","volume":"586","author":"Beaudoin","year":"2008","journal-title":"J. Physiol."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"934","DOI":"10.1038\/nn.3408","article-title":"Synaptic mechanisms of adaptation and sensitization in the retina","volume":"16","author":"Nikolaev","year":"2013","journal-title":"Nat. Neurosci."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1038\/s41467-022-28040-1","article-title":"Focused ultrasound excites cortical neurons via mechanosensitive calcium accumulation and ion channel amplification","volume":"13","author":"Yoo","year":"2022","journal-title":"Nat. Commun."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"e2300291120","DOI":"10.1073\/pnas.2300291120","article-title":"The mechanosensitive ion channel Piezo1 contributes to ultrasound neuromodulation","volume":"120","author":"Zhu","year":"2023","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"4481","DOI":"10.1038\/s41467-024-48683-6","article-title":"Noninvasive imaging-guided ultrasonic neurostimulation with arbitrary 2D patterns and its application for high-quality vision restoration","volume":"15","author":"Lu","year":"2024","journal-title":"Nat. Commun."},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"1039","DOI":"10.1016\/j.neuron.2019.11.006","article-title":"Single-cell profiles of retinal ganglion cells differing in resilience to injury reveal neuroprotective genes","volume":"104","author":"Tran","year":"2019","journal-title":"Neuron"}],"container-title":["Bioengineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2306-5354\/13\/9\/979\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T09:23:29Z","timestamp":1787736209000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2306-5354\/13\/9\/979"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,26]]},"references-count":45,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2026,9]]}},"alternative-id":["bioengineering13090979"],"URL":"https:\/\/doi.org\/10.3390\/bioengineering13090979","relation":{},"ISSN":["2306-5354"],"issn-type":[{"value":"2306-5354","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,26]]}}}