{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T15:21:02Z","timestamp":1791904862409,"version":"4.3.4"},"reference-count":23,"publisher":"MDPI AG","issue":"9","license":[{"start":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T00:00:00Z","timestamp":1788480000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Bioengineering"],"abstract":"<jats:p>Forward head posture (FHP) is common in young adults using technological devices and often accompanied by increased thoracic kyphosis. This study reports the design and custom manufacturing of a 3D-printed craniocervical orthosis and a pilot application evaluating its effects on the craniocervical angle (CVA), thoracic kyphosis angle (TKA), and user satisfaction. In this prospective, single-arm, within-subject pilot study, each participant underwent 3D scanning, and a custom orthosis was manufactured from their scan data using a common three-point CAD template via FDM 3D printing. Ten volunteers aged 18\u201325 years completed the study without a priori sample size calculation. The CVA and TKA were assessed photogrammetrically at baseline and weeks 2, 4, and 6, under orthosis-assisted and non-assisted conditions, with devices iteratively adjusted over six weeks. Satisfaction was evaluated at follow-up completion using the Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST 2.0-TR), and data were analyzed using a linear mixed model. Of the 13 individuals screened, 10 completed the protocol (one discontinued owing to discomfort and two withdrew voluntarily); no serious adverse events occurred. The CVA was significantly higher, and the TKA significantly lower, under the orthosis condition at every time point (all p &lt; 0.001), reflecting an acute, device-on effect rather than a demonstrated lasting, unassisted postural correction. Mean device satisfaction was 4.88 \u00b1 0.12\/5 and mean service satisfaction was 5.00 \u00b1 0.00\/5 among the 10 completers; these scores exclude the participant who discontinued owing to discomfort and two who withdrew for unrelated reasons, which likely inflates the apparent satisfaction level. The custom-manufactured orthosis was feasible to design and fabricate, tolerable after iterative adjustment, and associated with improved craniocervical and thoracic alignment when worn; these findings reflect an acute, device-on effect and do not yet establish lasting postural correction without the orthosis. Given the single-arm, non-blinded pilot design, findings are preliminary and hypothesis-generating, supporting further confirmatory trials.<\/jats:p>","DOI":"10.3390\/bioengineering13091030","type":"journal-article","created":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T13:22:57Z","timestamp":1788528177000},"page":"1030","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Craniocervical Orthosis Produced Using 3D Printing Technology for Anterior Head Tilt Posture and Thoracic Kyphosis: A Custom-Manufactured Device Pilot Application Study"],"prefix":"10.3390","volume":"13","author":[{"given":"Buse","family":"Ak\u00e7a","sequence":"first","affiliation":[{"name":"Graduate School of Health Sciences Ankara, Ankara University, Ankara 06100, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2557-4484","authenticated-orcid":false,"given":"Senem","family":"G\u00fcner","sequence":"additional","affiliation":[{"name":"Department of Orthotics and Prosthetics, Faculty of Health Sciences, Ankara University, Ankara 06100, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0731-6668","authenticated-orcid":false,"given":"Ahmet G\u00f6khan","family":"Acar","sequence":"additional","affiliation":[{"name":"Department of Orthotics and Prosthetics, Faculty of Health Sciences, Ankara University, Ankara 06100, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1566-3208","authenticated-orcid":false,"given":"Yunis","family":"Akka\u015f","sequence":"additional","affiliation":[{"name":"Department of Orthotics and Prosthetics, Faculty of Health Sciences, Ankara University, Ankara 06100, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2026,9,4]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"3577","DOI":"10.1007\/s00586-015-4254-x","article-title":"Evaluation of forward head posture in sitting and standing positions","volume":"25","author":"Shaghayeghfard","year":"2016","journal-title":"Eur. Spine J."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"3463","DOI":"10.1007\/s00586-023-07821-2","article-title":"Defining text neck: A scoping review","volume":"32","author":"Grasser","year":"2023","journal-title":"Eur. Spine J."},{"key":"ref_3","doi-asserted-by":"crossref","unstructured":"David, D., Giannini, C., Chiarelli, F., and Mohn, A. (2021). Text neck syndrome in children and adolescents. Int. J. Environ. Res. Public Health, 18.","DOI":"10.3390\/ijerph18041565"},{"key":"ref_4","first-page":"258","article-title":"The reliability and validity of measurement of craniovertebral angle using photographic method","volume":"30","author":"Kim","year":"2018","journal-title":"J. Phys. Ther. Sci."},{"key":"ref_5","first-page":"101","article-title":"Sagittal thoracic spine alignment and postural adaptations: A narrative review","volume":"46","author":"Oakley","year":"2024","journal-title":"J. Orthop. Med."},{"key":"ref_6","first-page":"E646","article-title":"Patients with neck pain demonstrate reduced variability of muscle activity during repetitive movements","volume":"31","author":"Falla","year":"2016","journal-title":"Spine"},{"key":"ref_7","first-page":"45","article-title":"Effectiveness of orthotic devices in the treatment of forward head posture: A systematic review","volume":"45","author":"Hamzelouie","year":"2025","journal-title":"J. Orthop. Rehabil."},{"key":"ref_8","first-page":"163","article-title":"Effect of the craniocervical brace on craniocervical angle, thoracic kyphosis angle, and trunk extensor muscle activity during typing in subjects with forward head posture","volume":"55","author":"Yoon","year":"2016","journal-title":"Work"},{"key":"ref_9","first-page":"411","article-title":"Additive manufacturing applications in medical cases: A literature based review","volume":"54","author":"Javaid","year":"2018","journal-title":"Alex. J. Med."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Dombroski, C.E., Balsdon, M.E., and Froats, A. (2014). The use of a low cost 3D scanning and printing tool in the manufacture of custom-made foot orthoses: A preliminary study. BMC Res. Notes, 7.","DOI":"10.1186\/1756-0500-7-443"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1002\/pst.185","article-title":"Sample size of 12 per group rule of thumb for a pilot study","volume":"4","author":"Julious","year":"2005","journal-title":"Pharm. Stat."},{"key":"ref_12","first-page":"e58047","article-title":"The validity and reliability of a smartphone application for measuring wrist and metacarpophalangeal joint motion","volume":"16","author":"Ozcelep","year":"2024","journal-title":"Cureus"},{"key":"ref_13","first-page":"19","article-title":"A methodological study on the reliability of Kinovea for assessing eccentric hamstring breakpoint angle in young football players","volume":"6","author":"Koc","year":"2025","journal-title":"Ulus. Kinesyoloji Derg."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1080\/09638280110066352","article-title":"Reliability, validity, and applicability of the Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST 2.0)","volume":"24","author":"Demers","year":"2002","journal-title":"Disabil. Rehabil."},{"key":"ref_15","first-page":"284","article-title":"Turkish adaptation of the Quebec User Evaluation of Satisfaction with Assistive Technology 2.0 in individuals using prostheses and orthoses","volume":"7","author":"Yakut","year":"2020","journal-title":"J. Exerc. Ther. Rehabil."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1016\/j.math.2012.07.005","article-title":"Effects of thoracic kyphosis and forward head posture on cervical range of motion in older adults","volume":"18","author":"Quek","year":"2013","journal-title":"Man. Ther."},{"key":"ref_17","first-page":"569","article-title":"Relationships between forward head posture and thoracic kyphosis in adolescents","volume":"26","author":"Ruivo","year":"2014","journal-title":"J. Phys. Ther. Sci."},{"key":"ref_18","first-page":"1856","article-title":"Characteristics of cervical position sense in subjects with forward head posture","volume":"29","author":"Lee","year":"2017","journal-title":"J. Phys. Ther. Sci."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"98","DOI":"10.5535\/arm.2012.36.1.98","article-title":"The effect of the forward head posture on postural balance in long time computer based worker","volume":"36","author":"Kang","year":"2012","journal-title":"Ann. Rehabil. Med."},{"key":"ref_20","first-page":"1450006","article-title":"Association between forward head posture and thoracic kyphosis in Indian population","volume":"17","author":"Singla","year":"2014","journal-title":"J. Musculoskelet. Res."},{"key":"ref_21","first-page":"252","article-title":"Orthotic management of forward head posture: A systematic review","volume":"29","author":"Nejati","year":"2022","journal-title":"J. Bodyw. Mov. Ther."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1682\/JRRD.2009.12.0195","article-title":"Dimensional accuracy of ankle-foot orthoses constructed by rapid customization and manufacturing framework","volume":"48","author":"Schrank","year":"2011","journal-title":"J. Rehabil. Res. Dev."},{"key":"ref_23","unstructured":"(2025). Biological Evaluation of Medical Devices\u2014Part 1: Requirements and General Principles for the Evaluation of Biological Safety Within a Risk Management Process (Standard No. ISO 10993-1:2025)."}],"container-title":["Bioengineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2306-5354\/13\/9\/1030\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T16:40:22Z","timestamp":1788540022000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2306-5354\/13\/9\/1030"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,4]]},"references-count":23,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2026,9]]}},"alternative-id":["bioengineering13091030"],"URL":"https:\/\/doi.org\/10.3390\/bioengineering13091030","relation":{},"ISSN":["2306-5354"],"issn-type":[{"value":"2306-5354","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,4]]}}}