{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T12:45:48Z","timestamp":1794314748739,"version":"4.9.0"},"reference-count":57,"publisher":"MDPI AG","issue":"6","license":[{"start":{"date-parts":[[2022,6,19]],"date-time":"2022-06-19T00:00:00Z","timestamp":1655596800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Bioengineering"],"abstract":"<jats:p>Adequate fixation is fundamental in revision total knee arthroplasty; consequently, surgeons must determine the correct set-up for each patient, choosing from numerous stem solutions. Several designs are currently available on the market, but there are no evidence-based quantitative biomechanical guideline yet. Therefore, several stems were designed and analyzed using a previously-validated finite-element model. The following parameters were studied: stem design characteristics (length and shape), added features (straight\/bowed stem), fixation technique, and effect of slots\/flutes. Bone stress and Risk of Fracture (RF) were analyzed in different regions of interest during a squat (up to 120\u00b0). For the femoral stem, the results indicated that all parameters influenced the bone stress distribution. The maximum von Mises stress and RF were always located near the tip of the stem. The long stems generated stress-shielding in the distal bone. Regarding the tibial stem, cemented stems showed lower micromotions at the bone-tibial tray interface and at the stem tip compared to press-fit stems, reducing the risk of implant loosening. The results demonstrated that anatomical shapes and slots reduce bone stress and risk of fracture, whereas flutes have the opposite effect; no relevant differences were found in this regard when alternating cemented and press-fit stem configurations. Cemented tibial stems reduce antero-posterior micromotions, preventing implant loosening.<\/jats:p>","DOI":"10.3390\/bioengineering9060259","type":"journal-article","created":{"date-parts":[[2022,6,19]],"date-time":"2022-06-19T10:14:52Z","timestamp":1655633692000},"page":"259","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Biomechanical Analysis of the Use of Stems in Revision Total Knee Arthroplasty"],"prefix":"10.3390","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8992-8865","authenticated-orcid":false,"given":"Bernardo","family":"Innocenti","sequence":"first","affiliation":[{"name":"BEAMS Department, Universit\u00e9 Libre de Bruxelles, Av. F. Roosevelt, 50 CP165\/56, 1050 Bruxelles, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1670-8359","authenticated-orcid":false,"given":"Edoardo","family":"Bori","sequence":"additional","affiliation":[{"name":"BEAMS Department, Universit\u00e9 Libre de Bruxelles, Av. F. Roosevelt, 50 CP165\/56, 1050 Bruxelles, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Silvia","family":"Pianigiani","sequence":"additional","affiliation":[{"name":"BEAMS Department, Universit\u00e9 Libre de Bruxelles, Av. F. Roosevelt, 50 CP165\/56, 1050 Bruxelles, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2022,6,19]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1007\/s12178-015-9295-6","article-title":"Level of constraint in revision knee arthroplasty","volume":"8","author":"Indelli","year":"2015","journal-title":"Curr. Rev. Musculoskelet. Med."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1097\/00003086-200211000-00003","article-title":"Insall award paper: Why are total knee arthroplasty failing today?","volume":"404","author":"Sharkey","year":"2002","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"1774","DOI":"10.1016\/j.arth.2013.07.024","article-title":"Why Are Total Knee Arthroplasties Failing Today\u2014Has Anything Changed After 10 Years?","volume":"29","author":"Sharkey","year":"2014","journal-title":"J. Arthroplast."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"780","DOI":"10.2106\/00004623-200704000-00012","article-title":"Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030","volume":"89","author":"Kurtz","year":"2007","journal-title":"J. Bone Jt. Surg. Am."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1221","DOI":"10.1007\/s11999-009-1204-0","article-title":"Midterm assessment of causes and results of revision total knee arthroplasty","volume":"468","author":"Hossain","year":"2010","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/j.arth.2007.03.025","article-title":"Revision total knee arthroplasty with modular cemented stems: Long-term follow-up","volume":"22","author":"Mabry","year":"2007","journal-title":"J. Arthroplast."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1016\/j.arth.2004.08.010","article-title":"Revision total knee arthroplasty with modular components inserted with metaphyseal cement and stems without cement","volume":"20","author":"Peters","year":"2005","journal-title":"J. Arthroplast."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1097\/01.blo.0000093032.56370.4b","article-title":"Stem fixation in revision total knee arthroplasty: A comparative analysis","volume":"416","author":"Fehring","year":"2003","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/S0883-5403(03)00301-2","article-title":"Revision total knee arthroplasty with cemented components and uncemented intramedullary stems","volume":"18","author":"Shannon","year":"2003","journal-title":"J. Arthroplast."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1097\/01.blo.0000138094.86911.55","article-title":"Reoperations after 3200 revision TKAs: Rates, etiology, and lessons learned","volume":"425","author":"Sierra","year":"2004","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"592","DOI":"10.1016\/S0883-5403(03)00200-6","article-title":"Cemented long-stem revision total knee arthroplasty","volume":"18","author":"Whaley","year":"2003","journal-title":"J. Arthroplast."},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"810","DOI":"10.1007\/s11999-008-0621-9","article-title":"Results of press-fit stems in revision knee arthroplasties","volume":"467","author":"Wood","year":"2009","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.jbiomech.2015.11.052","article-title":"Spatial distribution and remodeling of elastic modulus of bone in micro-regime as prediction of early stage osteoporosis","volume":"49","author":"Grover","year":"2016","journal-title":"J. Biomech."},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Bono, J.V., and Scott, R.D. (2005). Use of Stems in Revision Total Knee Arthroplasty. Revision Total Knee Arthroplasty, Springer International Publishing.","DOI":"10.1007\/b138582"},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Hirschmann, M.T., and Becker, R. (2015). The Unhappy Total Knee Replacement, Springer International Publishing.","DOI":"10.1007\/978-3-319-08099-4"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1097\/00003086-198911000-00013","article-title":"Tibial tray augmentation with modular metal wedges for tibial bone stock deficiency","volume":"248","author":"Brand","year":"1989","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/j.knee.2008.01.008","article-title":"The Influence of Different Tibial Stem Designs in Load Sharing and Stability at the Cement-Bone Interface in Revision TKA","volume":"15","author":"Completo","year":"2008","journal-title":"Knee"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1016\/j.arth.2014.03.049","article-title":"Clinical & Radiographic Outcomes of Cemented vs. Diaphyseal Engaging Cementless Stems in Aseptic Revision TKA","volume":"29","author":"Gililland","year":"2014","journal-title":"J. Arthroplast."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1219","DOI":"10.1016\/j.arth.2007.09.018","article-title":"The Effect of an Augmentation Patella Prosthesis Versus Patelloplasty on Revision Patellar Kinematics and Quadriceps Tendon Force: An Ex Vivo Study","volume":"23","author":"Mountney","year":"2008","journal-title":"J. Arthroplast."},{"key":"ref_20","first-page":"151","article-title":"Tibial Wedge Augmentation for Bone Deficiency in Total Knee Arthroplasty: A Follow-up Study","volume":"321","author":"Pagnano","year":"1995","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1308\/003588412X13171221592537","article-title":"Periprosthetic fractures around total knee arthroplasty","volume":"94","author":"Sarmah","year":"2012","journal-title":"Ann. R. Coll. Surg. Engl."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"106499","DOI":"10.1016\/j.cmpb.2021.106499","article-title":"Biomechanical analysis of femoral stems in hinged total knee arthroplasty in physiological and osteoporotic bone","volume":"213","author":"Bori","year":"2021","journal-title":"Comput. Methods Programs Biomed."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Innocenti, B., and Galbusera, F. (2022). The use of computational models in orthopedic biomechanical research. Human Orthopaedic Biomechanics, Academic Press.","DOI":"10.1016\/B978-0-12-824481-4.00003-2"},{"key":"ref_24","unstructured":"Stewart, J. (2015). The use of finite element modeling to improve biomechanical research on knee prosthesis. New Developments in Knee Prosthesis Research, Nova Science Publishers, Inc."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1016\/j.arth.2019.08.005","article-title":"Analysis of biomechanical differences between condylar constrained knee and rotating hinged implants: A numerical study","volume":"35","author":"Andreani","year":"2019","journal-title":"J. Arthroplast."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1491","DOI":"10.1016\/j.arth.2014.01.020","article-title":"Load sharing and ligament strains in balanced, overstuffed and understuffed UKA. A validated finite element analysis","volume":"29","author":"Labey","year":"2014","journal-title":"J. Arthroplast."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1016\/S0021-9290(97)00003-1","article-title":"Relationship between bone-prosthesis bonding and load transfer in total hip reconstruction","volume":"30","author":"McNamara","year":"1997","journal-title":"J. Biomech."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"111006","DOI":"10.1115\/1.4040966","article-title":"Biomechanical Analysis of Augments in Revision Total Knee Arthroplasty","volume":"140","author":"Innocenti","year":"2018","journal-title":"J. Biomech. Eng."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1177\/0954411916638684","article-title":"The influence of tibial component malalignment on bone strain in revision total knee replacement","volume":"230","author":"Rastetter","year":"2016","journal-title":"Proc. H Inst. Mech. Eng."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"1437","DOI":"10.1016\/j.arth.2013.01.010","article-title":"Stemmed TKA in a femur with a total hip arthroplasty. Is there a safe distance between the stem tips?","volume":"28","author":"Soenen","year":"2013","journal-title":"J. Arthroplast."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"1241","DOI":"10.1016\/0021-9290(95)00164-6","article-title":"The \u2018standardized femur program\u2019. Proposal for a reference geometry to be used for the creation of finite element models of the femur","volume":"29","author":"Viceconti","year":"1996","journal-title":"J. Biomech."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"1573","DOI":"10.1016\/j.jbiomech.2011.02.081","article-title":"Contact Forces in Several TKA Designs During Squatting: A Numerical Sensitivity Analysis","volume":"44","author":"Innocenti","year":"2011","journal-title":"J. Biomech."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"2315","DOI":"10.1016\/j.jbiomech.2012.06.014","article-title":"Tibio-Femoral Kinematics in Different Total Knee Arthroplasty Designs During a Loaded Squat: A Numerical Sensitivity Study","volume":"45","author":"Pianigiani","year":"2012","journal-title":"J. Biomech."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1016\/j.knee.2009.01.001","article-title":"How Precise Can Bony Landmarks Be Determined on a CT Scan of the Knee?","volume":"16","author":"Victor","year":"2009","journal-title":"Knee"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1016\/j.arth.2015.07.038","article-title":"Deviations from Optimal Alignment in TKA: Is There a Biomechanical Difference Between Femoral or Tibial Component Alignment?","volume":"31","author":"Innocenti","year":"2016","journal-title":"J. Arthroplast."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"2143","DOI":"10.2106\/JBJS.I.01398","article-title":"Effect of Postoperative Mechanical Axis Alignment on the Fifteen-Year Survival of Modern, Cemented Total Knee Replacements","volume":"15","author":"Parratte","year":"2010","journal-title":"J. Bone Jt. Surg. Am."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1007\/s12008-012-0167-7","article-title":"Finite element analysis of two total knee prostheses","volume":"7","author":"Ingrassia","year":"2013","journal-title":"Int. J. Interact. Des. Manuf."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1016\/S1350-4533(98)00007-1","article-title":"Mechanical properties and the hierarchical structure of bone","volume":"20","author":"Rho","year":"1998","journal-title":"Med. Eng. Phys."},{"key":"ref_39","first-page":"19","article-title":"Influence of three variables on the stresses in a three-dimensional model of a proximal tibia-total knee implant construct","volume":"17","author":"Lewis","year":"2007","journal-title":"Biomed. Mater. Eng."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"2550","DOI":"10.1007\/s00167-015-3630-8","article-title":"All-polyethylene tibial components generate higher stress and micromotions than metal-backed tibial components in total knee arthroplasty","volume":"24","author":"Brihault","year":"2016","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"2269","DOI":"10.1016\/j.matdes.2006.08.012","article-title":"The effects of static, dynamic and fatigue behavior on three-dimensional shape optimization of hip prosthesis by finite element method","volume":"28","author":"Kayabasi","year":"2007","journal-title":"Mater. Des."},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"2685","DOI":"10.1016\/j.arth.2016.07.006","article-title":"Biomechanical Effects of Different Varus and Valgus Alignments in Medial Unicompartmental Knee Arthroplasty","volume":"31","author":"Innocenti","year":"2017","journal-title":"J. Arthroplast."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"54","DOI":"10.3389\/fbioe.2014.00054","article-title":"Material Models and Properties in the Finite Element Analysis of Knee Ligaments: A Literature Review","volume":"2","author":"Galbusera","year":"2014","journal-title":"Front. Bioeng. Biotechnol."},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1016\/j.knee.2008.11.015","article-title":"Cementing the femoral component in total arthroplasty: Which technique is the best?","volume":"16","author":"Vaninbroukx","year":"2009","journal-title":"Knee"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"2415","DOI":"10.1007\/s00167-015-3514-y","article-title":"Knee Kinetics and Kinematics: What Are the Effects of TKA Malconfigurations?","volume":"24","author":"Pianigiani","year":"2016","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1016\/j.arth.2010.01.107","article-title":"Cementing the Tibial Component in Total Knee Arthroplasty: Which Technique Is the Best?","volume":"26","author":"Vanlommel","year":"2011","journal-title":"J. Arthroplast."},{"key":"ref_47","first-page":"1741","article-title":"Fixation techniques and stem dimensions in hinged total knee arthroplasty: A finite element study","volume":"136","author":"Heyse","year":"2015","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1097\/00003086-199910000-00027","article-title":"Pain at the end of the stem after revision total knee arthroplasty","volume":"367","author":"Barrack","year":"1999","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/j.arth.2004.06.009","article-title":"The effect of stem design on end-of-stem pain in revision total knee arthroplasty","volume":"19","author":"Barrack","year":"2004","journal-title":"J. Arthroplast."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"1009","DOI":"10.1302\/0301-620X.94B8.28289","article-title":"The role of the design of tibial components and stems in knee replacement","volume":"94","author":"Scott","year":"2012","journal-title":"J. Bone Joint Surg. Br."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"2476","DOI":"10.1007\/s00167-015-3863-6","article-title":"Femur bowing could be a risk factor for implant flexion in conventional total knee arthroplasty and notching in navigated total knee arthroplasty","volume":"24","author":"Ko","year":"2016","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1016\/j.clinbiomech.2008.01.010","article-title":"Analysis of biomechanical effect of stem-end design in revision TKA using Digital Korean model","volume":"23","author":"Kim","year":"2008","journal-title":"Clin. Biomech."},{"key":"ref_53","doi-asserted-by":"crossref","unstructured":"Fokter, S.K. (2012). Titanium as a Biomaterial for Implants. Recent Advances in Arthroplasty, IntechOpen.","DOI":"10.5772\/1445"},{"key":"ref_54","doi-asserted-by":"crossref","unstructured":"Plecko, M., Sievert, C., Andermatt, D., Frigg, R., Kronen, P., Klein, K., St\u00fcbinger, S., Nuss, K., B\u00fcrki, A., and Ferguson, S. (2012). Osseointegration and biocompatibility of different metal implants\u2014A comparative experimental investigation in sheep. BMC Musculoskelet. Disord., 13.","DOI":"10.1186\/1471-2474-13-32"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"759","DOI":"10.1054\/arth.2001.25507","article-title":"The effect of stem modularity and mode of fixation on tibial component stability in revision total knee arthroplasty","volume":"16","author":"Jazrawi","year":"2001","journal-title":"J. Arthroplast."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1097\/00003086-198205000-00042","article-title":"Effects of tibial components on load transfer in the upper tibia","volume":"165","author":"Reilly","year":"1982","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_57","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1097\/00003086-199712000-00008","article-title":"The effect of tibial stem design on component micromotion in knee arthroplasty","volume":"345","author":"Stern","year":"1997","journal-title":"Clin. Orthop. Relat. Res."}],"container-title":["Bioengineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2306-5354\/9\/6\/259\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T23:35:05Z","timestamp":1760139305000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2306-5354\/9\/6\/259"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,19]]},"references-count":57,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2022,6]]}},"alternative-id":["bioengineering9060259"],"URL":"https:\/\/doi.org\/10.3390\/bioengineering9060259","relation":{},"ISSN":["2306-5354"],"issn-type":[{"value":"2306-5354","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6,19]]}}}