{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T09:47:24Z","timestamp":1762508844109,"version":"build-2065373602"},"reference-count":35,"publisher":"MDPI AG","issue":"8","license":[{"start":{"date-parts":[[2022,8,17]],"date-time":"2022-08-17T00:00:00Z","timestamp":1660694400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Biomedicines"],"abstract":"<jats:p>Background: A ruptured abdominal aortic aneurysm is a severe condition associated with high mortality. Currently, the most important criterion used to estimate the risk of its rupture is the size of the aneurysm, but due to patients\u2019 anatomical variability, many aneurysms have a high risk of rupture with a small aneurysm size. We asked ourselves whether individual differences in anatomy could be taken into account when assessing the risk of rupture. Methods: Based on the CT scan image, aneurysm and normal aorta diameters were collected from 186 individuals and compared in patients with ruptured and unruptured aneurysms. To take into account anatomical differences between patients, diameter ratios were calculated by dividing the aneurysm diameter by the diameter of the normal aorta at various heights, and then further comparisons were made. Results: It was found that the calculated ratios differ between patients with ruptured and unruptured aneurysms. This observation is also present in patients with small aneurysms, with its maximal size below the level that indicates the need for surgical treatment. For small aneurysms, the ratios help us to estimate the risk of rupture better than the maximum sac size (AUC: 0.783 vs. 0.650). Conclusions: The calculated ratios appear to be a valuable feature to indicate which of the small aneurysms have a high risk of rupture. The obtained results suggest the need for further confirmation of their usefulness in subsequent groups of patients.<\/jats:p>","DOI":"10.3390\/biomedicines10081997","type":"journal-article","created":{"date-parts":[[2022,8,17]],"date-time":"2022-08-17T21:23:56Z","timestamp":1660771436000},"page":"1997","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["The Ratio of the Size of the Abdominal Aortic Aneurysm to That of the Unchanged Aorta as a Risk Factor for Its Rupture"],"prefix":"10.3390","volume":"10","author":[{"given":"Maciej","family":"Jusko","sequence":"first","affiliation":[{"name":"Department of General Surgery, Vascular Surgery, Angiology and Phlebology, Medical University of Silesia, 40-055 Katowice, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Piotr","family":"Kasprzak","sequence":"additional","affiliation":[{"name":"Department of Vascular Surgery, University Hospital Regensburg, 93053 Regensburg, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6554-1831","authenticated-orcid":false,"given":"Alicja","family":"Majos","sequence":"additional","affiliation":[{"name":"General and Transplant Surgery Department, Medical University of Lodz, 93-338 Lodz, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Waclaw","family":"Kuczmik","sequence":"additional","affiliation":[{"name":"Department of General Surgery, Vascular Surgery, Angiology and Phlebology, Medical University of Silesia, 40-055 Katowice, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2022,8,17]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1067\/mva.2001.115604","article-title":"Ruptured abdominal aortic aneurysms: The excessive mortality rate of conventional repair","volume":"34","author":"Noel","year":"2001","journal-title":"J. Vasc. Surg."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1016\/j.jvs.2014.07.098","article-title":"Endovascular balloon occlusion is associated with reduced intraoperative mortality of unstable patients with ruptured abdominal aortic aneurysm but fails to improve other outcomes","volume":"61","author":"Raux","year":"2015","journal-title":"J. Vasc. Surg."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1016\/j.ejvs.2015.02.015","article-title":"Midterm Re-interventions and Survival After Endovascular Versus Open Repair for Ruptured Abdominal Aortic Aneurysm","volume":"49","author":"Vahl","year":"2015","journal-title":"Eur. J. Vasc. Endovasc. Surg."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1016\/j.avsg.2014.12.014","article-title":"Risk-Adjusted Meta-analysis of 30-Day Mortality of Endovascular Versus Open Repair for Ruptured Abdominal Aortic Aneurysms","volume":"29","author":"Luebke","year":"2015","journal-title":"Ann. Vasc. Surg."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1016\/0741-5214(91)90249-T","article-title":"Determination of the Expansion Rate and Incidence of Rupture of Abdominal Aortic Aneurysms","volume":"14","author":"Limet","year":"1991","journal-title":"J. Vasc. Surg."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1111\/j.1749-6632.1996.tb33298.x","article-title":"Variables That Affect the Expansion Rate and Rupture of Abdominal Aortic Aneurysms","volume":"800","author":"Cronenwett","year":"1996","journal-title":"Ann. N. Y. Acad. Sci."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/j.ejvs.2005.03.009","article-title":"A Review of Biological Factors Implicated in Abdominal Aortic Aneurysm Rupture","volume":"30","author":"Choke","year":"2005","journal-title":"Eur. J. Vasc. Endovasc. Surg."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"500","DOI":"10.1016\/j.tcm.2019.11.006","article-title":"Small Abdominal Aortic Aneurysms: Has Anything Changed So Far?","volume":"30","author":"Galyfos","year":"2020","journal-title":"Trends Cardiovasc. Med."},{"key":"ref_9","first-page":"168","article-title":"A Comparative Study of Aortic Wall Stress Using Finite Element Analysis for Ruptured and Non-ruptured Abdominal Aortic Aneurysms","volume":"28","author":"Venkatasubramaniam","year":"2004","journal-title":"Eur. J. Vasc. Endovasc. Surg."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1583\/04-1239.1","article-title":"Heterogeneity of Tensile Strength and Matrix Metalloproteinase Activity in the Wall of Abdominal Aortic Aneurysms","volume":"11","author":"Vallabhaneni","year":"2004","journal-title":"J. Endovasc. Ther."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Maguire, E.M., Pearce, S.W.A., Xiao, R., Oo, A.Y., and Xiao, Q. (2019). Matrix Metalloproteinase in Abdominal Aortic Aneurysm and Aortic Dissection. Pharmaceuticals, 12.","DOI":"10.3390\/ph12030118"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1177\/0003319718785278","article-title":"The Association of Biomarkers of Inflammation and Extracellular Matrix Degradation with the Risk of Abdominal Aortic Aneurysm: The ARIC Study","volume":"70","author":"Tang","year":"2019","journal-title":"Angiology"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"MA3RS Study Investigators (2017). Aortic Wall Inflammation Predicts Abdominal Aortic Aneurysm Expansion, Rupture, and Need for Surgical Repair. Circulation, 136, 787\u2013797.","DOI":"10.1161\/CIRCULATIONAHA.117.028433"},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1016\/0022-4804(87)90178-8","article-title":"The influence of aorta-aneurysm geometry upon stress in the aneurysm wall","volume":"42","author":"Stringfellow","year":"1987","journal-title":"J. Surg Res."},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1006\/jsre.1993.1123","article-title":"Stress Distributions in Vascular Aneurysms: Factors Affecting Risk of Aneurysm Rupture","volume":"55","author":"Mower","year":"1993","journal-title":"J. Surg. Res."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1115\/1.2796014","article-title":"The Influence of Shape on the Stresses in Model Abdominal Aortic Aneurysms","volume":"118","author":"Elger","year":"1996","journal-title":"J. Biomech. Eng."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1016\/S1078-5884(98)80031-2","article-title":"Biomechanics of abdominal aortic aneurysm in the presence of endoluminal thrombus: Experimental characterisation and structural static computational analysis","volume":"15","author":"Mantero","year":"1998","journal-title":"Eur. J. Vasc. Endovasc. Surg."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"39","DOI":"10.23736\/S0392-9590.18.04006-3","article-title":"Effect of Intraluminal Thrombus on Growth Rate of Abdominal Aortic Aneurysms","volume":"38","author":"Domonkos","year":"2019","journal-title":"Int. Angiol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1067\/mva.2000.103693","article-title":"Thrombus within an aortic aneurysm does not reduce pressure on the aneurysmal wall","volume":"31","author":"Schurink","year":"2000","journal-title":"J. Vasc. Surg."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1115\/1.2834747","article-title":"Effect of Intraluminal Thrombus Thickness and Bulge Diameter on the Oxygen Diffusion in Abdominal Aortic Aneurysm","volume":"120","author":"Vorp","year":"1998","journal-title":"J. Biomech. Eng."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1067\/mva.2001.114813","article-title":"Association of intraluminal thrombus in abdominal aortic aneurysm with local hypoxia and wall weakening","volume":"34","author":"Vorp","year":"2001","journal-title":"J. Vasc. Surg."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1701","DOI":"10.1016\/S0002-9440(10)64447-1","article-title":"Involvement of the Mural Thrombus as a Site of Protease Release and Activation in Human Aortic Aneurysms","volume":"161","author":"Fontaine","year":"2002","journal-title":"Am. J. Path."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.jvs.2017.10.044","article-title":"The Society for Vascular Surgery Practice Guidelines on the Care of Patients with an Abdominal Aortic Aneurysm","volume":"67","author":"Chaikof","year":"2018","journal-title":"J. Vasc. Surg."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1016\/j.ejvs.2010.09.011","article-title":"Management of Abdominal Aortic Aneurysms Clinical Practice Guidelines of the European Society for Vascular Surgery","volume":"41","author":"Moll","year":"2011","journal-title":"Eur. J. Vasc. Endovasc Surg."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1016\/j.jvs.2018.04.035","article-title":"Geometric analysis of ruptured and nonruptured abdominal aortic aneurysms","volume":"69","author":"Kimura","year":"2019","journal-title":"J. Vasc. Surg."},{"key":"ref_26","first-page":"472","article-title":"Actuarial analysis of variables associated with rupture of small abdominal aortic aneurysms","volume":"98","author":"Cronenwett","year":"1985","journal-title":"Surgery"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1437","DOI":"10.1056\/NEJMoa012573","article-title":"Immediate Repair Compared with Surveillance of Small Abdominal Aortic Aneurysms","volume":"346","author":"Lederle","year":"2002","journal-title":"N. Engl. J. Med."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"1122","DOI":"10.1111\/ijcp.12453","article-title":"Diagnostic accuracy of non-radiologist performed ultrasound for abdominal aortic aneurysm: Systematic review and meta-analysis","volume":"68","author":"Concannon","year":"2014","journal-title":"Int. J. Clin. Pract."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1016\/j.jvs.2011.04.047","article-title":"Contrast-induced nephropathy","volume":"54","author":"Rundback","year":"2011","journal-title":"J. Vasc. Surg."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"706","DOI":"10.1016\/j.ejvs.2017.09.010","article-title":"Increased Peak Wall Stress, but Not Maximum Diameter, Is Associated with Symptomatic Abdominal Aortic Aneurysm","volume":"54","author":"Soto","year":"2017","journal-title":"Eur. J. Vasc. Endovasc. Surg."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/j.medengphy.2018.06.007","article-title":"Geometric surrogates of abdominal aortic aneurysm wall mechanics","volume":"59","author":"Urrutia","year":"2018","journal-title":"Med. Eng. Phys."},{"key":"ref_32","doi-asserted-by":"crossref","unstructured":"Zelaya, J.E., Goenezen, S., Dargon, P.T., Azarbal, A.-F., and Rugonyi, S. (2014). Improving the efficiency of abdominal aortic aneurysm wall stress computations. PLoS ONE, 9.","DOI":"10.1371\/journal.pone.0101353"},{"key":"ref_33","first-page":"1","article-title":"Statistical techniques for predicting rupture risk in abdominal aortic aneurysms: A contribution based on bootstrap","volume":"104","author":"Lipsa","year":"2021","journal-title":"Sci. Prog."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/j.ejvs.2009.09.026","article-title":"The Role of Geometric Parameters in the Prediction of Abdominal Aortic Aneurysm Wall Stress","volume":"39","author":"Georgakarakos","year":"2010","journal-title":"Eur. J. Vasc Surg."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1196\/annals.1383.046","article-title":"A biomechanics-based rupture potential index for abdominal aortic aneurysm risk assessment: Demonstrative application","volume":"1085","author":"Geest","year":"2006","journal-title":"Ann. N. Y. Acad. Sci."}],"container-title":["Biomedicines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2227-9059\/10\/8\/1997\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T00:11:03Z","timestamp":1760141463000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2227-9059\/10\/8\/1997"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8,17]]},"references-count":35,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2022,8]]}},"alternative-id":["biomedicines10081997"],"URL":"https:\/\/doi.org\/10.3390\/biomedicines10081997","relation":{},"ISSN":["2227-9059"],"issn-type":[{"type":"electronic","value":"2227-9059"}],"subject":[],"published":{"date-parts":[[2022,8,17]]}}}