{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T02:33:33Z","timestamp":1793932413644,"version":"4.8.0"},"reference-count":39,"publisher":"MDPI AG","issue":"4","license":[{"start":{"date-parts":[[2023,4,21]],"date-time":"2023-04-21T00:00:00Z","timestamp":1682035200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Biomedicines"],"abstract":"<jats:p>Central blood pressure (cBP) is known to be a better predictor of the damage caused by hypertension in comparison with peripheral blood pressure. During cardiac catheterization, we measured cBP in the ascending aorta with a fluid-filled guiding catheter (FF) in 75 patients and with a high-fidelity micromanometer tipped wire (FFR) in 20 patients. The wire was withdrawn into the brachial artery and aorto-brachial pulse wave velocity (abPWV) was calculated from the length of the pullback and the time delay between the ascending aorta and the brachial artery pulse waves by gating to the R-wave of the ECG for both measurements. In 23 patients, a cuff was inflated around the calf and an aorta-tibial pulse wave velocity (atPWV) was calculated from the distance between the cuff around the leg and the axillary notch and the time delay between the ascending aorta and the tibial pulse waves. Brachial BP was measured non-invasively and cBP was estimated using a new suprasystolic oscillometric technology. The mean differences between invasively measured cBP by FFR and non-invasive estimation were \u22120.4 \u00b1 5.7 mmHg and by FF 5.4 \u00b1 9.4 mmHg in 52 patients. Diastolic and mean cBP were both overestimated by oscillometry, with mean differences of \u22128.9 \u00b1 5.5 mmHg and \u22126.4 \u00b1 5.1 mmHg compared with the FFR and \u221210.6 \u00b1 6.3 mmHg and \u22125.9 \u00b1 6.2 mmHg with the FF. Non-invasive systolic cBP compared accurately with the high-fidelity FFR measurements, demonstrating a low bias (\u22645 mmHg) and high precision (SD \u2264 8 mmHg). These criteria were not met when using the FF measurements. Invasively derived average Ao-brachial abPWV was 7.0 \u00b1 1.4 m\/s and that of Ao-tibial atPWV was 9.1 \u00b1 1.8 m\/s. Non-invasively estimated PWV based on the reflected wave transit time did not correlate with abPWV or with atPWV. In conclusion, we demonstrate the advantages of a novel method of validation for non-invasive cBP monitoring devices using acknowledged gold standard FFR wire transducers and the possibility to easily measure PWV during coronary angiography with the impact of cardiovascular risk factors.<\/jats:p>","DOI":"10.3390\/biomedicines11041235","type":"journal-article","created":{"date-parts":[[2023,4,21]],"date-time":"2023-04-21T10:11:25Z","timestamp":1682071885000},"page":"1235","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["High Fidelity Pressure Wires Provide Accurate Validation of Non-Invasive Central Blood Pressure and Pulse Wave Velocity Measurements"],"prefix":"10.3390","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0195-1321","authenticated-orcid":false,"given":"Alessandro","family":"Scalia","sequence":"first","affiliation":[{"name":"Department of Cardiology, Centre Hospitalier Universitaire Ambroise Par\u00e9, 7000 Mons, Belgium"},{"name":"Department of Cardiology, UMONS Research Institute for Health Sciences and Technology, University of Mons (UMONS), 7000 Mons, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5971-5073","authenticated-orcid":false,"given":"Chadi","family":"Ghafari","sequence":"additional","affiliation":[{"name":"Department of Cardiology, UMONS Research Institute for Health Sciences and Technology, University of Mons (UMONS), 7000 Mons, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wivine","family":"Navarre","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, Universit\u00e9 Libre de Bruxelles, 1070 Bruxelles, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philippe","family":"Delmotte","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Centre Hospitalier Universitaire Ambroise Par\u00e9, 7000 Mons, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rob","family":"Phillips","sequence":"additional","affiliation":[{"name":"The School of Medicine, The University of Queensland, Brisbane 4072, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7787-1937","authenticated-orcid":false,"given":"St\u00e9phane","family":"Carlier","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Centre Hospitalier Universitaire Ambroise Par\u00e9, 7000 Mons, Belgium"},{"name":"Department of Cardiology, UMONS Research Institute for Health Sciences and Technology, University of Mons (UMONS), 7000 Mons, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2023,4,21]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"e127","DOI":"10.1016\/j.jacc.2017.11.006","article-title":"2017 ACC\/AHA\/AAPA\/ABC\/ACPM\/AGS\/APhA\/ASH\/ASPC\/NMA\/PCNA Guideline for the Prevention, Detection, Evaluation, and Management of High Blood Pressure in Adults","volume":"71","author":"Whelton","year":"2018","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"2224","DOI":"10.1016\/S0140-6736(12)61766-8","article-title":"A comparative risk assessment of burden of disease and injury attributable to 67 risk factors and risk factor clusters in 21 regions, 1990\u20132010: A systematic analysis for the Global Burden of Disease Study 2010","volume":"380","author":"Lim","year":"2012","journal-title":"Lancet"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"3021","DOI":"10.1093\/eurheartj\/ehy339","article-title":"2018 ESC\/ESH Guidelines for the management of arterial hypertension: The Task Force for the management of arterial hypertension of the European Society of Cardiology (ESC) and the European Society of Hypertension (ESH)","volume":"39","author":"Williams","year":"2018","journal-title":"Eur. Heart J."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"680","DOI":"10.1001\/jama.2021.24464","article-title":"Validation Status of Blood Pressure Measuring Devices Sold Globally","volume":"327","author":"Picone","year":"2022","journal-title":"JAMA"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1161\/HYPERTENSIONAHA.107.089078","article-title":"Central Pressure More Strongly Relates to Vascular Disease and Outcome Than Does Brachial Pressure","volume":"50","author":"Roman","year":"2007","journal-title":"Hypertension"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"S23","DOI":"10.1016\/j.cjca.2014.03.010","article-title":"Central Blood Pressure as an Index of Antihypertensive Control: Determinants and Potential Value","volume":"30","author":"Trudeau","year":"2014","journal-title":"Can. J. Cardiol."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"90","DOI":"10.5527\/wjn.v5.i1.90","article-title":"Central blood pressure and chronic kidney disease","volume":"5","author":"Ohno","year":"2016","journal-title":"World J. Nephrol."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1719","DOI":"10.1093\/eurheartj\/eht565","article-title":"Central blood pressure: Current evidence and clinical importance","volume":"35","author":"McEniery","year":"2014","journal-title":"Eur. Heart J."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1161\/HYPERTENSIONAHA.109.133009","article-title":"Amplification of the Pressure Pulse in the Upper Limb in Healthy, Middle-Aged Men and Women","volume":"54","author":"Segers","year":"2009","journal-title":"Hypertension"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"1476","DOI":"10.1161\/HYPERTENSIONAHA.107.105445","article-title":"Central Pressure: Variability and Impact of Cardiovascular Risk Factors","volume":"51","author":"McEniery","year":"2008","journal-title":"Hypertension"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1161\/HYPERTENSIONAHA.109.134379","article-title":"Role of Pulse Pressure Amplification in Arterial Hypertension","volume":"54","author":"Avolio","year":"2009","journal-title":"Hypertension"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.artres.2012.09.001","article-title":"Arterial stiffening: Causes and consequences","volume":"7","author":"Cecelja","year":"2013","journal-title":"Artery Res."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1258\/cvd.2012.012024","article-title":"Arterial stiffness","volume":"1","author":"Quinn","year":"2012","journal-title":"JRSM Cardiovasc. Dis."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1161\/01.HYP.0000164581.39811.bd","article-title":"Basal NO Locally Modulates Human Iliac Artery Function In Vivo","volume":"46","author":"Schmitt","year":"2005","journal-title":"Hypertension"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1045","DOI":"10.1093\/ajh\/hpt081","article-title":"Effects of Antihypertensive Drugs on Central Blood Pressure in Humans: A Preliminary Observation","volume":"26","author":"Agnoletti","year":"2013","journal-title":"Am. J. Hypertens."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1161\/hy1001.096106","article-title":"Prospective Evaluation of a Method for Estimating Ascending Aortic Pressure From the Radial Artery Pressure Waveform","volume":"38","author":"Pauca","year":"2001","journal-title":"Hypertension"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1007\/s10877-013-9477-y","article-title":"Validation of the new Complior sensor to record pressure signals non-invasively","volume":"27","author":"Sztrymf","year":"2013","journal-title":"J. Clin. Monit. Comput."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"H542","DOI":"10.1152\/ajpheart.2000.279.2.H542","article-title":"Individualizing the aorto-radial pressure transfer function: Feasibility of a model-based approach","volume":"279","author":"Segers","year":"2000","journal-title":"Am. J. Physiol.-Heart Circ. Physiol."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"1237","DOI":"10.1097\/HJH.0000000000000921","article-title":"Accuracy of commercial devices and methods for noninvasive estimation of aortic systolic blood pressure a systematic review and meta-analysis of invasive validation studies","volume":"34","author":"Papaioannou","year":"2016","journal-title":"J. Hypertens."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"1318","DOI":"10.1016\/j.jacc.2009.10.061","article-title":"Prediction of Cardiovascular Events and All-Cause Mortality With Arterial Stiffness","volume":"55","author":"Vlachopoulos","year":"2010","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1161\/CIRCULATIONAHA.109.886655","article-title":"Arterial Stiffness and Cardiovascular Events","volume":"121","author":"Mitchell","year":"2010","journal-title":"Circulation"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"636","DOI":"10.1016\/j.jacc.2013.09.063","article-title":"Aortic Pulse Wave Velocity Improves Cardiovascular Event Prediction","volume":"63","author":"Spears","year":"2014","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/j.ijcard.2011.01.045","article-title":"Association between brachial-ankle pulse wave velocity and occult coronary artery disease detected by multi-detector computed tomography","volume":"157","author":"Nam","year":"2012","journal-title":"Int. J. Cardiol."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"2588","DOI":"10.1093\/eurheartj\/ehl254","article-title":"Expert consensus document on arterial stiffness: Methodological issues and clinical applications","volume":"27","author":"Laurent","year":"2006","journal-title":"Eur. Heart J."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1097\/HJH.0000000000002237","article-title":"Accuracy of fully automated oscillometric central aortic blood pressure measurement techniques","volume":"38","author":"Gotzmann","year":"2020","journal-title":"J. Hypertens."},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"2370","DOI":"10.1097\/HJH.0000000000002943","article-title":"Inaccuracy of brachial blood pressure and its potential impact on treatment and aortic blood pressure estimation","volume":"39","author":"Kowalski","year":"2021","journal-title":"J. Hypertens."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"2111","DOI":"10.1016\/j.jbiomech.2009.05.029","article-title":"Non-invasive model-based estimation of aortic pulse pressure using suprasystolic brachial pressure waveforms","volume":"42","author":"Lowe","year":"2009","journal-title":"J. Biomech."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1097\/00000542-198103000-00010","article-title":"Direct Blood Pressure Measurement\u2014Dynamic Response Requirements","volume":"54","author":"Gardner","year":"1981","journal-title":"Anesthesiology"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.mpaic.2011.10.010","article-title":"Principles of pressure transducers, resonance, damping and frequency response","volume":"13","author":"Gilbert","year":"2012","journal-title":"Anaesth. Intensive Care Med."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"2123","DOI":"10.12998\/wjcc.v11.i10.2123","article-title":"Fractional flow reserve and non-hyperemic indices: Essential tools for percutaneous coronary interventions","volume":"11","author":"Boutaleb","year":"2023","journal-title":"World J. Clin. Cases"},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"2805","DOI":"10.1093\/eurheartj\/ehw632","article-title":"Validation of non-invasive central blood pressure devices: ARTERY Society task force consensus statement on protocol standardization","volume":"38","author":"Sharman","year":"2017","journal-title":"Eur. Heart J."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1109\/RBME.2021.3092208","article-title":"Non-Invasive Methods for PWV Measurement in Blood Vessel Stiffness Assessment","volume":"15","author":"Fiori","year":"2022","journal-title":"IEEE Rev. Biomed. Eng."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"876","DOI":"10.1007\/s10439-010-9945-1","article-title":"Numerical Validation of a New Method to Assess Aortic Pulse Wave Velocity from a Single Recording of a Brachial Artery Waveform with an Occluding Cuff","volume":"38","author":"Trachet","year":"2010","journal-title":"Ann. Biomed. Eng."},{"key":"ref_34","first-page":"307","article-title":"Measurement in Medicine: The Analysis of Method Comparison Studies","volume":"32","author":"Altman","year":"1983","journal-title":"J. R. Stat. Soc. Ser. Stat."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1186\/s13054-016-1354-x","article-title":"The accuracy of blood pressure measured by arterial line and non-invasive cuff in critically ill children","volume":"20","author":"Joffe","year":"2016","journal-title":"Crit. Care"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1097\/HJH.0000000000001135","article-title":"Invasive validation of a novel brachial cuff-based oscillometric device (SphygmoCor XCEL) for measuring central blood pressure","volume":"35","author":"Shoji","year":"2017","journal-title":"J. Hypertens."},{"key":"ref_37","first-page":"2338","article-title":"The Reference Values for Arterial Stifness?","volume":"31","author":"Hofman","year":"2010","journal-title":"Collaboration. Determinants of Pulse wave velocity in healthy people amd im the presence of cardiovascular rsik factors: \u201cEstablishing normal and reference values.\u201d Eur. Heart J."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"2022","DOI":"10.1097\/HJH.0b013e32832e94e7","article-title":"Comparison between carotid-femoral and brachial-ankle pulse wave velocity as measures of arterial stiffness","volume":"27","author":"Tanaka","year":"2009","journal-title":"J. Hypertens."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1016\/j.jacc.2017.05.064","article-title":"Accuracy of Cuff-Measured Blood Pressure","volume":"70","author":"Picone","year":"2017","journal-title":"J. Am. Coll. Cardiol."}],"container-title":["Biomedicines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2227-9059\/11\/4\/1235\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T19:20:49Z","timestamp":1760124049000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2227-9059\/11\/4\/1235"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4,21]]},"references-count":39,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2023,4]]}},"alternative-id":["biomedicines11041235"],"URL":"https:\/\/doi.org\/10.3390\/biomedicines11041235","relation":{},"ISSN":["2227-9059"],"issn-type":[{"value":"2227-9059","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,4,21]]}}}