{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,14]],"date-time":"2026-11-14T01:37:54Z","timestamp":1794620274220,"version":"4.9.1"},"reference-count":117,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2025,10,31]],"date-time":"2025-10-31T00:00:00Z","timestamp":1761868800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Biomedicines"],"abstract":"<jats:p>Transesophageal echocardiography (TEE) has long been established as a cornerstone imaging modality in cardiac surgery and perioperative medicine. In recent years, however, its role has expanded into emergency and intensive care settings, where rapid and accurate hemodynamic assessment is crucial for survival. Point-of-care TEE provides advantages over transthoracic echocardiography when acoustic windows are limited, particularly in mechanically ventilated or critically unstable patients, allowing continuous high-quality visualization of cardiac function, volume status, and great vessel pathology to guide immediate therapeutic interventions. This narrative review examines the evolving role of TEE in acute settings, with emphasis on its application in shock, cardiac arrest, pulmonary embolism, tamponade, and its value in extracorporeal membrane oxygenation (ECMO) cannulation. Advances such as three-dimensional TEE, miniaturized probes, and the integration of artificial intelligence are also discussed, as potential drivers of innovation. While bridging technological progress with clinical practice, TEE emerges as a versatile tool in critical care. However, its broader adoption is still limited by probe availability, operator training, and institutional resources. Overcoming these barriers will be essential to translating technological advances into widespread practice.<\/jats:p>","DOI":"10.3390\/biomedicines13112680","type":"journal-article","created":{"date-parts":[[2025,11,3]],"date-time":"2025-11-03T13:55:22Z","timestamp":1762178122000},"page":"2680","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Point-of-Care Transesophageal Echocardiography in Emergency and Intensive Care: An Evolving Imaging Modality"],"prefix":"10.3390","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-5046-4275","authenticated-orcid":false,"given":"Debora Emanuela","family":"Torre","sequence":"first","affiliation":[{"name":"Department of Cardiac Anesthesia and Intensive Care Unit, Cardiac Surgery, Ospedale dell\u2019Angelo, Mestre, 30174 Venice, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0119-6549","authenticated-orcid":false,"given":"Carmelo","family":"Pirri","sequence":"additional","affiliation":[{"name":"Department of Neurosciences, Institute of Human Anatomy, University of Padova, 35121 Padova, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,10,31]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"314","DOI":"10.17305\/bb.2024.10847","article-title":"Transesophageal echocardiography: Revolutionizing perioperative cardiac care","volume":"25","author":"Liang","year":"2025","journal-title":"Biomol. Biomed."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1007\/s13665-024-00351-2","article-title":"Transesophageal Echocardiography in Critical Care","volume":"13","author":"Bora","year":"2024","journal-title":"Curr. Pulmonol. Rep."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"745","DOI":"10.1016\/j.jacc.2020.05.074","article-title":"Focused Transesophageal Echocardiography During Cardiac Arrest Resuscitation: JACC Review Topic of the Week","volume":"76","author":"Teran","year":"2020","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"271","DOI":"10.15441\/ceem.22.399","article-title":"Intra-arrest transesophageal echocardiography during cardiopulmonary resuscitation","volume":"9","author":"Hwang","year":"2022","journal-title":"Clin. Exp. Emerg. Med."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.resuscitation.2020.06.035","article-title":"Intra-arrest transoesophageal echocardiographic findings and resuscitation outcomes","volume":"154","author":"Jung","year":"2020","journal-title":"Resuscitation"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1111\/echo.15266","article-title":"Echocardiography for extracorporeal membrane oxygenation","volume":"39","author":"Hussey","year":"2022","journal-title":"Echocardiography"},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Farina, J.M., Barry, T., Arsanjani, R., Ayoub, C., and Naqvi, T.Z. (2023). Three-Dimensional Transesophageal Echocardiography in Percutaneous Catheter-Based Cardiac Interventions. J. Clin. Med., 12.","DOI":"10.3390\/jcm12175664"},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"R121","DOI":"10.1186\/cc12793","article-title":"Hemodynamic assessment of critically ill patients using a miniaturized transesophageal echocardiography probe","volume":"17","author":"Cioccari","year":"2013","journal-title":"Crit. Care"},{"key":"ref_9","doi-asserted-by":"crossref","unstructured":"Kagiyama, N., Abe, Y., Kusunose, K., Kato, N., Kaneko, T., Murata, A., Ota, M., Shibayama, K., Izumo, M., and Watanabe, H. (2024). Multicenter validation study for automated left ventricular ejection fraction assessment using a handheld ultrasound with artificial intelligence. Sci. Rep., 14.","DOI":"10.1038\/s41598-024-65557-5"},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1016\/j.chest.2018.09.023","article-title":"Better with Ultrasound: Transesophageal Echocardiography","volume":"155","author":"Jaidka","year":"2019","journal-title":"Chest."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"P182","DOI":"10.1186\/cc12120","article-title":"Utility of transesophageal echocardiography in the ICU: A preliminary US perspective","volume":"17","author":"Kaynar","year":"2013","journal-title":"Crit. Care"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1177\/08850666221115348","article-title":"Indications, Clinical Impact, and Complications of Critical Care Transesophageal Echocardiography: A Scoping Review","volume":"38","author":"Prager","year":"2023","journal-title":"J. Intensive Care Med."},{"key":"ref_13","first-page":"e1035","article-title":"Point-of-Care Echocardiography in the Difficult-to-Image Patient in the ICU: A Narrative Review","volume":"6","author":"Grotberg","year":"2024","journal-title":"Crit. Care Explor."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"791","DOI":"10.21037\/atm-2020-hdm-23","article-title":"Hemodynamic monitoring using trans esophageal echocardiography in patients with shock","volume":"8","author":"Boissier","year":"2020","journal-title":"Ann. Transl. Med."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Cha, S., and Kostibas, M.P. (2024). Echocardiographic and Point-of-Care Ultrasonography (POCUS) Guidance in the Management of the ECMO Patient. J. Clin. Med., 13.","DOI":"10.3390\/jcm13092630"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1186\/s13049-023-01077-x","article-title":"Resuscitative transesophageal echocardiography in the emergency department: A single-centre case series","volume":"31","author":"Kegel","year":"2023","journal-title":"Scand. J. Trauma Resusc. Emerg. Med."},{"key":"ref_17","doi-asserted-by":"crossref","unstructured":"Krammel, M., Hamp, T., Hafner, C., Magnet, I., Poppe, M., and Marhofer, P. (2023). Feasibility of resuscitative transesophageal echocardiography at out-of-hospital emergency scenes of cardiac arrest. Sci. Rep., 13.","DOI":"10.1038\/s41598-023-46684-x"},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"100861","DOI":"10.1016\/j.resplu.2024.100861","article-title":"Enhancing resuscitative transesophageal echocardiography training by integrating clinical scenarios","volume":"21","author":"Chen","year":"2024","journal-title":"Resusc. Plus"},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1016\/j.resuscitation.2019.02.013","article-title":"Evaluation of out-of-hospital cardiac arrest using transesophageal echocardiography in the emergency department","volume":"137","author":"Teran","year":"2019","journal-title":"Resuscitation"},{"key":"ref_20","doi-asserted-by":"crossref","unstructured":"Mauriello, A., Marrazzo, G., Del Vecchio, G.E., Ascrizzi, A., Roma, A.S., Correra, A., Sabatella, F., Gioia, R., Desiderio, A., and Russo, V. (2024). Echocardiography in Cardiac Arrest: Incremental Diagnostic and Prognostic Role During Resuscitation Care. Diagnostics, 14.","DOI":"10.20944\/preprints202409.0540.v1"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1055\/s-2007-1013821","article-title":"Reproducibility of assessment of left-ventricular function using intraoperative transesophageal echocardiography","volume":"41","author":"Deutsch","year":"1993","journal-title":"Thorac. Cardiovasc. Surg."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1186\/s12947-015-0015-6","article-title":"Variability in echocardiographic measurements of left ventricular function in septic shock patients","volume":"13","author":"Oscarsson","year":"2015","journal-title":"Cardiovasc. Ultrasound"},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1186\/s13089-019-0120-0","article-title":"Basic critical care echocardiography training of intensivists allows reproducible and reliable measurements of cardiac output","volume":"11","author":"Villavicencio","year":"2019","journal-title":"Ultrasound J."},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1016\/j.ajem.2016.10.018","article-title":"Emergency physician performed tricuspid annular plane systolic excursion in the evaluation of suspected pulmonary embolism","volume":"35","author":"Daley","year":"2017","journal-title":"Am. J. Emerg. Med."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"1017","DOI":"10.1007\/s10554-018-1306-4","article-title":"The feasibility of tricuspid annular plane systolic excursion performed by transesophageal echocardiography throughout heart surgery and its interchangeability with transthoracic echocardiography","volume":"34","author":"Korshin","year":"2018","journal-title":"Int. J. Cardiovasc. Imaging"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.echo.2014.10.003","article-title":"Recommendations for cardiac chamber quantification by echocardiography in adults: An update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging","volume":"28","author":"Lang","year":"2015","journal-title":"J. Am. Soc. Echocardiogr."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"1301","DOI":"10.1093\/ehjci\/jex244","article-title":"2016\u20132018 EACVI Scientific Documents Committee; 2016\u20132018 EACVI Scientific Documents Committee. Standardization of adult transthoracic echocardiography reporting in agreement with recent chamber quantification, diastolic function, and heart valve disease recommendations: An expert consensus document of the European Association of Cardiovascular Imaging","volume":"18","author":"Galderisi","year":"2017","journal-title":"Eur. Heart J. Cardiovasc. Imaging."},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Raksamani, K., Noirit, A., and Chaikittisilpa, N. (2023). Comparison of visual estimation and quantitative measurement of left ventricular ejection fraction in untrained perioperative echocardiographers. BMC Anesthesiol., 23.","DOI":"10.1186\/s12871-023-02067-3"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1016\/j.echo.2010.05.010","article-title":"Guidelines for the echocardiographic assessment of the right heart in adults: A report from the American Society of Echocardiography endorsed by the European Association of Echocardiography, a registered branch of the European Society of Cardiology, and the Canadian Society of Echocardiography","volume":"23","author":"Rudski","year":"2010","journal-title":"J. Am. Soc. Echocardiogr."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1007\/BF01728328","article-title":"Transgastric, pulsed Doppler echocardiographic determination of cardiac output","volume":"22","author":"Smail","year":"1996","journal-title":"Intensive Care Med."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1016\/j.echo.2025.03.011","article-title":"Recommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography and for Heart Failure With Preserved Ejection Fraction Diagnosis: An Update from the American Society of Echocardiography","volume":"38","author":"Nagueh","year":"2025","journal-title":"J. Am. Soc. Echocardiogr."},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1186\/s13613-022-01022-8","article-title":"Prediction of fluid responsiveness. What\u2019s new?","volume":"12","author":"Monnet","year":"2022","journal-title":"Ann. Intensive Care"},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1186\/s13089-021-00225-7","article-title":"Resuscitative transesophageal echocardiography in the diagnosis of post-CABG loculated pericardial clot causing cardiac tamponade","volume":"13","author":"Adi","year":"2021","journal-title":"Ultrasound J."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"780","DOI":"10.1016\/S0735-1097(97)00218-0","article-title":"Diagnostic accuracy of transesophageal echocardiography during cardiopulmonary resuscitation","volume":"30","author":"Koster","year":"1997","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"350","DOI":"10.1097\/00000542-199808000-00010","article-title":"Intraoperative determination of cardiac output using multiplane transesophageal echocardiography: A comparison to thermodilution","volume":"89","author":"Perrino","year":"1998","journal-title":"Anesthesiology"},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1023\/A:1009982611386","article-title":"A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques","volume":"15","author":"Critchley","year":"1999","journal-title":"J. Clin. Monit. Comput."},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1016\/S0002-9149(99)80107-6","article-title":"Comparison of echocardiographic assessment of cardiac hemodynamics in the intensive care unit with right-sided cardiac catheterization","volume":"76","author":"Dabaghi","year":"1995","journal-title":"Am. J. Cardiol."},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1378\/chest.112.3.722","article-title":"Noninvasive diagnosis of suspected severe pulmonary embolism: Transesophageal echocardiography vs. spiral CT","volume":"112","author":"Pruszczyk","year":"1997","journal-title":"Chest"},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1016\/j.jemermed.2017.08.011","article-title":"Bedside Identification of Massive Pulmonary Embolism with Point-of-Care Transesophageal Echocardiography","volume":"53","author":"Jelic","year":"2017","journal-title":"J. Emerg. Med."},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"e08","DOI":"10.15420\/usc.2021.03","article-title":"Echocardiography in the Evaluation of the Right Heart","volume":"16","author":"Tsipis","year":"2022","journal-title":"US Cardiol."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1016\/j.case.2020.05.007","article-title":"Clot in Transit on Transesophageal Echocardiography in a Prone Patient with COVID-19 Acute Respiratory Distress Syndrome","volume":"4","author":"Horowitz","year":"2020","journal-title":"CASE"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"e04994","DOI":"10.1002\/ccr3.4994","article-title":"McConnell\u2019s sign: Echocardiography in the management of acute pulmonary embolism","volume":"9","author":"Patel","year":"2021","journal-title":"Clin. Case Rep."},{"key":"ref_43","first-page":"e13800","article-title":"Analysis of the 60\/60 Sign and Other Right Ventricular Parameters by 2D Transthoracic Echocardiography as Adjuncts to Diagnosis of Acute Pulmonary Embolism","volume":"13","author":"Shah","year":"2021","journal-title":"Cureus"},{"key":"ref_44","doi-asserted-by":"crossref","first-page":"1310","DOI":"10.1378\/chest.112.5.1310","article-title":"Diagnosis and treatment of shock due to massive pulmonary embolism: Approach with transesophageal echocardiography and intrapulmonary thrombolysis","volume":"112","author":"Krivec","year":"1997","journal-title":"Chest"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"1575","DOI":"10.1007\/s11604-025-01811-8","article-title":"Comprehensive review of pulmonary embolism imaging: Past, present and future innovations in computed tomography (CT) and other diagnostic techniques","volume":"43","author":"Triggiani","year":"2025","journal-title":"Jpn. J. Radiol."},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1093\/eurheartj\/ehz405","article-title":"2019 ESC Guidelines for the diagnosis and management of acute pulmonary embolism developed in collaboration with the European Respiratory Society (ERS)","volume":"41","author":"Konstantinides","year":"2020","journal-title":"Eur Heart J."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"109426","DOI":"10.1016\/j.ejrad.2020.109426","article-title":"Effects of radiation dose reduction on diagnostic performance of 3rd generation Dual Source CT pulmonary angiography","volume":"134","author":"Winkelmann","year":"2021","journal-title":"Eur. J. Radiol."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1186\/s40560-018-0274-z","article-title":"Predicting contrast-induced nephropathy after CT pulmonary angiography in the critically ill: A retrospective cohort study","volume":"6","author":"Ho","year":"2018","journal-title":"J. Intensive Care"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1186\/s13089-025-00418-4","article-title":"Assess, improve, detect, guide: A narrative review and proposal for a standardized protocol for prehospital transesophageal echocardiography during out-of-hospital cardiac arrest","volume":"17","author":"Katzenschlager","year":"2025","journal-title":"Ultrasound J."},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1186\/s13054-023-04575-7","article-title":"Hemodynamic impact of chest compression location during cardiopulmonary resuscitation guided by transesophageal echocardiography","volume":"27","author":"Teran","year":"2023","journal-title":"Crit. Care"},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1186\/s13089-019-0150-7","article-title":"Bedside ultrasound in cardiac standstill: A clinical review","volume":"11","author":"Hussein","year":"2019","journal-title":"Ultrasound J."},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"5285","DOI":"10.1007\/s00431-023-05199-3","article-title":"Unveiling pseudo-pulseless electrical activity (pseudo-PEA) in ultrasound-integrated infant resuscitation","volume":"182","author":"Chan","year":"2023","journal-title":"Eur. J. Pediatr."},{"key":"ref_53","doi-asserted-by":"crossref","unstructured":"P\u00e9rez-Casares, A., Cesar, S., Brunet-Garcia, L., and Sanchez-de-Toledo, J. (2017). Echocardiographic Evaluation of Pericardial Effusion and Cardiac Tamponade. Front. Pediatr., 5.","DOI":"10.3389\/fped.2017.00079"},{"key":"ref_54","doi-asserted-by":"crossref","unstructured":"Wang, T.K.M., Klein, A.L., Cremer, P.C., Imazio, M., Kohnstamm, S., Luis, S.A., Mardigyan, V., Mukherjee, M., Ordovas, K., and Vakamudi, S. (2025). 2025 Concise Clinical Guidance: An ACC Expert Consensus Statement on the Diagnosis and Management of Pericarditis: A Report of the American College of Cardiology Solution Set Oversight Committee. J. Am. Coll. Cardiol.","DOI":"10.1016\/j.jacc.2025.05.023"},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1186\/s13054-015-1042-2","article-title":"Echocardiography for adult patients supported with extracorporeal membrane oxygenation","volume":"19","author":"Roscoe","year":"2015","journal-title":"Crit. Care"},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"1637","DOI":"10.1016\/j.ajem.2016.06.038","article-title":"Emergency physician-performed transesophageal echocardiography for extracorporeal life support vascular cannula placement","volume":"34","author":"Fair","year":"2016","journal-title":"Am. J. Emerg. Med."},{"key":"ref_57","first-page":"291","article-title":"Contemporary Comprehensive Monitoring of Veno-Arterial Extracorporeal Membrane Oxygenation Patients","volume":"36","author":"Bhatia","year":"2020","journal-title":"Can. J. Cardiol."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"283","DOI":"10.4103\/aca.ACA_75_19","article-title":"Transesophageal Echocardiography Compared to Fluoroscopy for Avalon Bicaval Dual-Lumen Cannula Positioning for Venovenous ECMO","volume":"23","author":"Hemamalini","year":"2020","journal-title":"Ann. Card. Anaesth."},{"key":"ref_59","doi-asserted-by":"crossref","first-page":"4296","DOI":"10.1053\/j.jvca.2022.07.020","article-title":"Transesophageal Echocardiography-Guided Extracorporeal Membrane Oxygenation Cannulation in COVID-19 Patients","volume":"36","author":"Urner","year":"2022","journal-title":"J. Cardiothorac. Vasc. Anesth."},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1097\/01.MAT.0000142872.19219.C0","article-title":"The use of transesophageal echocardiography to demonstrate obstruction of venous drainage cannula during ECMO","volume":"50","author":"Ranasinghe","year":"2004","journal-title":"ASAIO J."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1051\/ject\/201850167","article-title":"Malposition of the Extracorporeal Membrane Oxygenation Venous Cannula in an Accessory Hepatic Vein","volume":"50","author":"Winiszewski","year":"2018","journal-title":"J. Extra Corpor. Technol."},{"key":"ref_62","doi-asserted-by":"crossref","unstructured":"Tigano, S., Casolaro, G., Bianchini, A., Bernardi, E., Laici, C., Ramahi, L., Vitale, G., and Siniscalchi, A. (2025). Hemodynamic Monitoring During Liver Transplantation for Patients on Perioperative Extracorporeal Membrane Oxygenation (ECMO) Support: A Narrative Review. Medicina, 61.","DOI":"10.3390\/medicina61040768"},{"key":"ref_63","doi-asserted-by":"crossref","first-page":"20150705","DOI":"10.1259\/bjr.20150705","article-title":"Recommendations for accurate CT diagnosis of suspected acute aortic syndrome (AAS)--on behalf of the British Society of Cardiovascular Imaging (BSCI)\/British Society of Cardiovascular CT (BSCCT)","volume":"89","author":"Vardhanabhuti","year":"2016","journal-title":"Br. J. Radiol."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"1350","DOI":"10.1001\/archinte.166.13.1350","article-title":"Diagnostic Accuracy of Transesophageal Echocardiography, Helical Computed Tomography, and Magnetic Resonance Imaging for Suspected Thoracic Aortic Dissection: Systematic Review and Meta-Analysis","volume":"166","author":"Shiga","year":"2006","journal-title":"Arch. Intern. Med."},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"R53","DOI":"10.1530\/ERP-18-0058","article-title":"The current role of echocardiography in acute aortic syndrome","volume":"6","author":"Evangelista","year":"2019","journal-title":"Echo Res. Pract."},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1016\/j.jcmg.2013.10.015","article-title":"The role of imaging in aortic dissection and related syndromes","volume":"7","author":"Baliga","year":"2014","journal-title":"JACC Cardiovasc. Imaging"},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1186\/s40981-025-00802-y","article-title":"Progressive coronary stenosis detected by intraoperative TEE after acute type-A aortic dissection repair: A case report","volume":"11","author":"Komatsu","year":"2025","journal-title":"JA Clin. Rep."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1016\/j.echo.2025.03.017","article-title":"Intraoperative Transesophageal Echocardiography in Acute Type A Aortic Dissection: Contemporary Approach","volume":"38","author":"Kelava","year":"2025","journal-title":"J. Am. Soc. Echocardiogr."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"2618","DOI":"10.1097\/CCM.0b013e31829e4dc5","article-title":"Focused critical care echocardiography","volume":"41","author":"Talmor","year":"2013","journal-title":"Crit. Care Med."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"2115","DOI":"10.1016\/j.jacc.2023.03.412","article-title":"Management of Mechanical Prosthetic Heart Valve Thrombosis: JACC Review Topic of the Week","volume":"81","author":"Papolos","year":"2023","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_71","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.echo.2023.10.004","article-title":"Guidelines for the Evaluation of Prosthetic Valve Function with Cardiovascular Imaging: A Report from the American Society of Echocardiography Developed in Collaboration with the Society for Cardiovascular Magnetic Resonance and the Society of Cardiovascular Computed Tomography","volume":"37","author":"Zoghbi","year":"2024","journal-title":"J. Am. Soc. Echocardiogr."},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"617","DOI":"10.2147\/VHRM.S425525","article-title":"Mechanical Aortic Valve Thrombosis with Heart Failure Successfully Treated with Oral Anticoagulation: A Case Report","volume":"19","author":"Ababneh","year":"2023","journal-title":"Vasc. Health Risk Manag."},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"3948","DOI":"10.1093\/eurheartj\/ehad193","article-title":"2023 ESC Guidelines for the management of endocarditis","volume":"44","author":"Delgado","year":"2023","journal-title":"Eur. Heart J."},{"key":"ref_74","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1007\/s11886-024-02042-5","article-title":"Echocardiography in the Recognition and Management of Mechanical Complications of Acute Myocardial Infarction","volume":"26","author":"Zhang","year":"2024","journal-title":"Curr. Cardiol. Rep."},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"2532","DOI":"10.1161\/01.CIR.88.6.2532","article-title":"The role of transesophageal echocardiography in identifying anomalous coronary arteries","volume":"88","author":"Fernandes","year":"1993","journal-title":"Circulation"},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"921","DOI":"10.1016\/j.echo.2013.07.009","article-title":"Guidelines for performing a comprehensive transesophageal echocardiographic examination: Recommendations from the American Society of Echocardiography and the Society of Cardiovascular Anesthesiologists","volume":"26","author":"Hahn","year":"2013","journal-title":"J. Am. Soc. Echocardiogr."},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"1195","DOI":"10.1016\/j.echo.2022.07.017","article-title":"Multidisciplinary Approach to Improving Safety in Transesophageal Echocardiography in Patients with Relative Contraindications","volume":"35","author":"Mishra","year":"2022","journal-title":"J. Am. Soc. Echocardiogr."},{"key":"ref_78","doi-asserted-by":"crossref","unstructured":"De Luca, V.M., Cammalleri, V., Antonelli, G., Bombace, S., Ruf, T.F., G\u00f6\u00dfler, T.A.M., Lurz, P., von Bardeleben, R.S., Grigioni, F., and Ussia, G.P. (2024). The Other Side of the Coin: Transesophageal Echocardiography Complications following Cardiac Surgery and Transcatheter Structural Heart Interventions. J. Clin. Med., 13.","DOI":"10.3390\/jcm13154291"},{"key":"ref_79","doi-asserted-by":"crossref","unstructured":"Zhang, L., Xie, Y., Ren, Z., and Xie, M. (2024). Transesophageal echocardiography related complications. Front. Cardiovasc. Med., 11.","DOI":"10.3389\/fcvm.2024.1410594"},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"3292","DOI":"10.1053\/j.jvca.2022.02.015","article-title":"Complications of Transesophageal Echocardiography: A Review of Injuries, Risk Factors, and Management","volume":"36","author":"Patel","year":"2022","journal-title":"J. Cardiothorac. Vasc. Anesth."},{"key":"ref_81","doi-asserted-by":"crossref","first-page":"e05164","DOI":"10.1002\/ccr3.5164","article-title":"Three-dimensional critical care transesophageal echocardiography: A bedside tool in the diagnosis and management of shock","volume":"9","author":"Higny","year":"2021","journal-title":"Clin. Case Rep."},{"key":"ref_82","doi-asserted-by":"crossref","first-page":"110220","DOI":"10.1016\/j.resuscitation.2024.110220","article-title":"Personalized resuscitation using 3D transesophageal echocardiography","volume":"199","author":"Chen","year":"2024","journal-title":"Resuscitation"},{"key":"ref_83","doi-asserted-by":"crossref","first-page":"S271","DOI":"10.21037\/jtd.2017.03.123","article-title":"An update on intraoperative three-dimensional transesophageal echocardiography","volume":"9","author":"Rong","year":"2017","journal-title":"J. Thorac. Dis."},{"key":"ref_84","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1161\/CIRCULATIONAHA.107.751354","article-title":"Real-time 3-dimensional echocardiography: An integral component of the routine echocardiographic examination in adult patients?","volume":"119","author":"Sugeng","year":"2009","journal-title":"Circulation"},{"key":"ref_85","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1016\/j.amjcard.2006.08.026","article-title":"Comparison of two- and three-dimensional echocardiography with sequential magnetic resonance imaging for evaluating left ventricular volume and ejection fraction over time in patients with healed myocardial infarction","volume":"99","author":"Jenkins","year":"2007","journal-title":"Am. J. Cardiol."},{"key":"ref_86","doi-asserted-by":"crossref","first-page":"1814","DOI":"10.1161\/01.CIR.0000142670.65971.5F","article-title":"Fast measurement of left ventricular mass with real-time three-dimensional echocardiography: Comparison with magnetic resonance imaging","volume":"110","author":"Sugeng","year":"2004","journal-title":"Circulation"},{"key":"ref_87","doi-asserted-by":"crossref","first-page":"1358","DOI":"10.1097\/MS9.0000000000000601","article-title":"Diagnostic accuracy of two-dimensional and three-dimensional transesophageal echocardiography in detecting pannus and thrombus in left mechanical valve obstruction","volume":"85","author":"Pham","year":"2023","journal-title":"Ann. Med. Surg."},{"key":"ref_88","doi-asserted-by":"crossref","first-page":"e99","DOI":"10.1097\/MAT.0000000000002147","article-title":"Transesophageal Echocardiography Guided Veno-Pulmonary Extracorporeal Membrane Oxygenation Cannula Insertion Technique","volume":"70","author":"Landolt","year":"2024","journal-title":"ASAIO J."},{"key":"ref_89","doi-asserted-by":"crossref","first-page":"1860","DOI":"10.1111\/echo.14879","article-title":"Utility of three-dimensional transesophageal echocardiography to guide transseptal positioning of a single multistage venous cannula to provide both venous drainage and indirect left ventricular venting in veno-arterial extracorporeal membrane oxygenation","volume":"37","author":"Addis","year":"2020","journal-title":"Echocardiography"},{"key":"ref_90","doi-asserted-by":"crossref","first-page":"1886","DOI":"10.1007\/s00134-015-3998-4","article-title":"Hemodynamic assessment of ventilated ICU patients with cardiorespiratory failure using a miniaturized multiplane transesophageal echocardiography probe","volume":"41","author":"Begot","year":"2015","journal-title":"Intensive Care Med."},{"key":"ref_91","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1186\/s12947-025-00354-2","article-title":"Mini 3D transesophageal probe: Technical advances and clinical applications","volume":"23","author":"Barki","year":"2025","journal-title":"Cardiovasc. Ultrasound"},{"key":"ref_92","doi-asserted-by":"crossref","first-page":"1540","DOI":"10.1053\/j.jvca.2018.08.199","article-title":"Miniaturized Echocardiography in the Cardiac Intensive Care Unit","volume":"33","author":"Hastie","year":"2019","journal-title":"J. Cardiothorac. Vasc. Anesth."},{"key":"ref_93","doi-asserted-by":"crossref","first-page":"1308","DOI":"10.1053\/j.jvca.2017.10.017","article-title":"Impact of a Monoplane Hemodynamic TEE (hTEE) Monitoring Device on Decision Making in a Heterogeneous Hemodynamically Unstable Intensive Care Unit Population: A Prospective, Observational Study","volume":"32","author":"Hlaing","year":"2018","journal-title":"J. Cardiothorac. Vasc. Anesth."},{"key":"ref_94","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1007\/s00134-012-2797-4","article-title":"A pilot study on safety and clinical utility of a single-use 72-h indwelling transesophageal echocardiography probe","volume":"39","author":"Slama","year":"2013","journal-title":"Intensive Care Med."},{"key":"ref_95","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1007\/s00134-019-05670-6","article-title":"Continual hemodynamic monitoring with a single-use transesophageal echocardiography probe in critically ill patients with shock: A randomized controlled clinical trial","volume":"45","author":"Merz","year":"2019","journal-title":"Intensive Care Med."},{"key":"ref_96","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1038\/s44325-025-00064-8","article-title":"Contemporary applications of artificial intelligence and machine learning in echocardiography","volume":"2","author":"Xu","year":"2025","journal-title":"NPJ Cardiovasc. Health"},{"key":"ref_97","doi-asserted-by":"crossref","unstructured":"Tian, Y., Qin, W., Zhao, Z., Wang, C., Tian, Y., Zhang, Y., He, K., Zhang, Y., Shen, L., and Zhou, Z. (2024). Deep Learning Based Automatic Left Ventricle Segmentation from the Transgastric Short-Axis View on Transesophageal Echocardiography: A Feasibility Study. Diagnostics, 14.","DOI":"10.3390\/diagnostics14151655"},{"key":"ref_98","doi-asserted-by":"crossref","unstructured":"Zhang, Y., Liu, B., Bunting, K.V., Brind, D., Thorley, A., Karwath, A., Lu, W., Zhou, D., Wang, X., and Mobley, A.R. (2024). Development of automated neural network prediction for echocardiographic left ventricular ejection fraction. Front. Med., 11.","DOI":"10.3389\/fmed.2024.1354070"},{"key":"ref_99","doi-asserted-by":"crossref","unstructured":"Chen, W., Wu, J., Zhang, Z., Gao, Z., Chen, X., Zhang, Y., Lin, Z., Tang, Z., Yu, W., and Fan, S. (2024). Artificial intelligence-assisted echocardiographic monitoring in pediatric patients on extracorporeal membrane oxygenation. Front. Cardiovasc. Med., 11.","DOI":"10.3389\/fcvm.2024.1418741"},{"key":"ref_100","doi-asserted-by":"crossref","unstructured":"Myhre, P.L., Grenne, B., Asch, F.M., Delgado, V., Khera, R., Lafitte, S., Lang, R.M., Pellikka, P.A., Sengupta, P.P., and Vemulapalli, S. (2025). Artificial intelligence-enhanced echocardiography in cardiovascular disease management. Nat. Rev. Cardiol.","DOI":"10.1038\/s41569-025-01197-0"},{"key":"ref_101","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1186\/s12947-021-00261-2","article-title":"Artificial intelligence in echocardiography: Detection, functional evaluation, and disease diagnosis","volume":"19","author":"Zhou","year":"2021","journal-title":"Cardiovasc. Ultrasound"},{"key":"ref_102","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/S0735-1097(96)00448-2","article-title":"Cost-effectiveness of transesophageal echocardiographic-guided cardioversion: A decision analytic model for patients admitted to the hospital with atrial fibrillation","volume":"29","author":"Seto","year":"1997","journal-title":"J. Am. Coll. Cardiol."},{"key":"ref_103","doi-asserted-by":"crossref","first-page":"810","DOI":"10.7326\/0003-4819-130-10-199905180-00004","article-title":"Cost-effectiveness of transesophageal echocardiography to determine the duration of therapy for intravascular catheter-associated Staphylococcus aureus bacteremia","volume":"130","author":"Rosen","year":"1999","journal-title":"Ann. Intern. Med."},{"key":"ref_104","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3310\/hta10290","article-title":"An evaluation of the clinical and cost-effectiveness of pulmonary artery catheters in patient management in intensive care: A systematic review and a randomised controlled trial","volume":"10","author":"Harvey","year":"2006","journal-title":"Health Technol. Assess."},{"key":"ref_105","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1016\/j.jacc.2019.02.003","article-title":"2019 ACC\/AHA\/ASE Advanced Training Statement on Echocardiography (Revision of the 2003 ACC\/AHA Clinical Competence Statement on Echocardiography): A Report of the ACC Competency Management Committee","volume":"74","author":"Wiegers","year":"2019","journal-title":"J. Am. Coll Cardiol."},{"key":"ref_106","unstructured":"(2023). AIUM Official Statement: Guidelines for Cleaning and Preparing External- and Internal-Use Ultrasound Transducers and Equipment Between Patients as Well as Safe Handling and Use of Ultrasound Coupling Gel. J. Ultrasound Med., 42, E13\u2013E22."},{"key":"ref_107","doi-asserted-by":"crossref","first-page":"i17","DOI":"10.1093\/ejechocard\/jer095","article-title":"Guidelines for transoesophageal echocardiographic probe cleaning and disinfection from the British Society of Echocardiography","volume":"12","author":"Kanagala","year":"2011","journal-title":"Eur. J. Echocardiogr."},{"key":"ref_108","doi-asserted-by":"crossref","unstructured":"Steffner, K.R., Christensen, M., Gill, G., Bowdish, M., Rhee, J., Kumaresan, A., He, B., Zou, J., and Ouyang, D. (2024). Deep learning for transesophageal echocardiography view classification. Sci. Rep., 14.","DOI":"10.1038\/s41598-023-50735-8"},{"key":"ref_109","doi-asserted-by":"crossref","first-page":"S66","DOI":"10.5005\/jp-journals-10071-24301","article-title":"ISCCM Guidelines for Hemodynamic Monitoring in the Critically Ill","volume":"26","author":"Kulkarni","year":"2022","journal-title":"Indian. J. Crit. Care Med."},{"key":"ref_110","doi-asserted-by":"crossref","first-page":"315","DOI":"10.3949\/ccjm.58.4.315","article-title":"Transesophageal echocardiography in the critical care unit","volume":"58","author":"Font","year":"1991","journal-title":"Cleve Clin. J. Med."},{"key":"ref_111","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1177\/87564793241228533","article-title":"Transesophageal Echocardiography: Timely Resolution of an Urgent Right Atrial Mass\/Hepatocellular Carcinoma Thrombosis","volume":"40","author":"Pirri","year":"2024","journal-title":"J. Diagn. Med. Sonogr."},{"key":"ref_112","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1111\/echo.14558","article-title":"Detection of LV apical thrombus by three-dimensional transesophageal echocardiography","volume":"37","author":"Fazlinezhad","year":"2020","journal-title":"Echocardiography"},{"key":"ref_113","doi-asserted-by":"crossref","first-page":"1854","DOI":"10.1016\/j.jcmg.2018.06.024","article-title":"3-Dimensional Echocardiography: Latest Developments and Future Directions","volume":"11","author":"Lang","year":"2018","journal-title":"JACC Cardiovasc. Imaging"},{"key":"ref_114","doi-asserted-by":"crossref","first-page":"e45464","DOI":"10.2196\/45464","article-title":"Augmented Reality in Real-Time Telemedicine and Telementoring: Scoping Review","volume":"11","author":"Dinh","year":"2023","journal-title":"JMIR Mhealth Uhealth."},{"key":"ref_115","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1093\/ejechocard\/jep222","article-title":"Usefulness of trans-oesophageal echocardiography using intracardiac echography probe in guiding patent foramen ovale percutaneous closure","volume":"11","author":"Lim","year":"2010","journal-title":"Eur. J. Echocardiogr."},{"key":"ref_116","doi-asserted-by":"crossref","first-page":"1855","DOI":"10.1016\/j.jcin.2024.05.042","article-title":"Intracardiac Echocardiographic Probe Used Via Transesophageal to Guide Left Atrial Appendage Occlusion: The DIONISO Study","volume":"17","author":"Laterra","year":"2024","journal-title":"JACC Cardiovasc. Interv."},{"key":"ref_117","doi-asserted-by":"crossref","unstructured":"Laterra, G., Dattilo, G., Correale, M., Brunetti, N.D., Artale, C., Sacchetta, G., Pistelli, L., Borgi, M., Campanella, F., and Cocuzza, F. (2023). Imaging Modality to Guide Left Atrial Appendage Closure: Current Status and Future Perspectives. J. Clin. Med., 12.","DOI":"10.3390\/jcm12113756"}],"container-title":["Biomedicines"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2227-9059\/13\/11\/2680\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,3]],"date-time":"2025-11-03T14:37:15Z","timestamp":1762180635000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2227-9059\/13\/11\/2680"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,31]]},"references-count":117,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2025,11]]}},"alternative-id":["biomedicines13112680"],"URL":"https:\/\/doi.org\/10.3390\/biomedicines13112680","relation":{},"ISSN":["2227-9059"],"issn-type":[{"value":"2227-9059","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,31]]}}}