{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,8]],"date-time":"2026-06-08T10:00:52Z","timestamp":1780912852089,"version":"3.54.1"},"reference-count":30,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2025,5,18]],"date-time":"2025-05-18T00:00:00Z","timestamp":1747526400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"Research Start-up Fund for Doctoral Scholars, Xi\u2019an University of Technology","award":["106-451123004"],"award-info":[{"award-number":["106-451123004"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Biomimetics"],"abstract":"<jats:p>To address lower limb fatigue in workers engaged in prolonged standing, this study proposes a structural design for a medial-support passive exoskeleton seat. The design incorporates support rods positioned along the medial aspect of the user\u2019s lower limbs and features an adaptive telescopic rod system, enhancing sitting stability and reducing collision risks in workplace environments. Human motion capture technology was used to collect kinematic data of the lower limbs, and a mathematical model of center-of-gravity variation was developed to calculate and optimize the exoskeleton\u2019s structural parameters. Static analysis was performed using ANSYS software (2025 R1) to evaluate the structural integrity of the design. The effectiveness of the exoskeleton seat was validated through surface electromyography (sEMG) experiments, with results showing that the exoskeleton significantly reduces lower limb muscle load by 49.2% to 72.9%. Additionally, force plate experiments demonstrated that the exoskeleton seat improves stability, with a 39.2% reduction in the average displacement of the center of pressure (CoP), confirming its superior postural alignment and balance. The design was also compared with existing exoskeleton chairs, showing comparable or better performance in terms of muscle load reduction, stability, and overall effectiveness.<\/jats:p>","DOI":"10.3390\/biomimetics10050330","type":"journal-article","created":{"date-parts":[[2025,5,19]],"date-time":"2025-05-19T06:31:29Z","timestamp":1747636289000},"page":"330","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Research and Design of a Medial-Support Exoskeleton Chair"],"prefix":"10.3390","volume":"10","author":[{"given":"Wenzhou","family":"Lin","sequence":"first","affiliation":[{"name":"School of Art and Design, Xi\u2019an University of Technology, Xi\u2019an 710054, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yin","family":"Xiong","sequence":"additional","affiliation":[{"name":"School of Art and Design, Xi\u2019an University of Technology, Xi\u2019an 710054, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chunqiang","family":"Zhang","sequence":"additional","affiliation":[{"name":"School of Art and Design, Xi\u2019an University of Technology, Xi\u2019an 710054, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xupeng","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Art and Design, Xi\u2019an University of Technology, Xi\u2019an 710054, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bing","family":"Han","sequence":"additional","affiliation":[{"name":"School of Mechanical and Electrical Engineering, Northwestern Polytechnical University, Xi\u2019an 710021, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,5,18]]},"reference":[{"key":"ref_1","first-page":"88","article-title":"Research progress on lower limb medical rehabilitation exoskeleton robots","volume":"46","author":"Wang","year":"2025","journal-title":"Chin. J. Med. Instrum."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Onofrejova, D., Balazikova, M., Glatz, J., Kotianova, Z., and Vaskovicova, K. (2022). Ergonomic Assessment of Physical Load in Slovak Industry Using Wearable Technologies. Appl. Sci., 12.","DOI":"10.3390\/app12073607"},{"key":"ref_3","first-page":"6","article-title":"Prevalence and influencing factors of work-related musculoskeletal disorders among workers in a furniture manufacturing factory","volume":"40","author":"Zeng","year":"2023","journal-title":"J. Environ. Occup. Med."},{"key":"ref_4","first-page":"16","article-title":"Research on the design and evaluation of industrial lower-limb support exoskeletons","volume":"7","author":"Zhang","year":"2021","journal-title":"Mod. Manuf. Eng."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1080\/00140139.2020.1870162","article-title":"Effects of industrial back-support exoskeletons on body loading and user experience: An updated systematic review","volume":"64","author":"Kermavnar","year":"2020","journal-title":"Ergonomics"},{"key":"ref_6","unstructured":"Noonee (2025, May 01). The Chairless Chair. Available online: https:\/\/www.noonee.com."},{"key":"ref_7","doi-asserted-by":"crossref","unstructured":"Kong, Y.K., Park, C.W., Cho, M.U., Kim, S.Y., Kim, M.J., Hyun, D.J., Bae, K., Choi, J.K., Ko, S.M., and Choi, K.H. (2021). Guidelines for Working Heights of the Lower-limb Exoskeleton (CEX) Based on Ergonomic Evaluations. Int. J. Environ. Res. Public Health, 18.","DOI":"10.3390\/ijerph18105199"},{"key":"ref_8","unstructured":"SuitX (2025, May 01). LegX. Available online: https:\/\/www.suitx.com\/legx."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1109\/THMS.2022.3216761","article-title":"Lower Extremity Posture Assistive Wearable Devices: A Review","volume":"53","author":"Wijegunawardana","year":"2023","journal-title":"IEEE Trans. Hum.-Mach. Syst."},{"key":"ref_10","first-page":"38","article-title":"Dual-mode exoskeleton structure design and optimization","volume":"12","author":"Feng","year":"2020","journal-title":"Mech. Eng."},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"992","DOI":"10.1016\/j.bbe.2019.01.002","article-title":"Development and testing of a passive walking assist exoskeleton","volume":"39","author":"Lovrenovic","year":"2019","journal-title":"Biocybern. Biomed. Eng."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Han, Y., Liu, Y., and Zhang, W. (2021, January 27\u201331). Design of a Passive Exoskeleton Chair with an Auxiliary Support Mechanism for Assembly Tasks. Proceedings of the 2021 IEEE International Conference on Robotics and Biomimetics (ROBIO), Sanya, China.","DOI":"10.1109\/ROBIO54168.2021.9739312"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Fournier, D.E., Yung, M., Somasundram, K.G., Du, B.B., Rezvani, S., and Yazdani, A. (2023). Quality, productivity, and economic implications of exoskeletons for occupational use: A systematic review. PLoS ONE, 18.","DOI":"10.1371\/journal.pone.0287742"},{"key":"ref_14","first-page":"295","article-title":"Design and support performance evaluation of a medical multi-posture assisted support exoskeleton mechanism","volume":"41","author":"Qi","year":"2024","journal-title":"J. Biomed. Eng."},{"key":"ref_15","unstructured":"Zhou, C.G., Meng, Q., Zhang, X.D., Cao, Y.H., and Zheng, Y. (2025). Design and analysis of a multi-degree-of-freedom gait-assisted lower limb exoskeleton robot. Mech. Sci. Technol. Aerosp. Eng., 1\u20138."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Ikeuchi, Y., Ashihara, J., Hiki, Y., Kudoh, H., and Noda, T. (2009, January 10\u201315). Walking assist device with body-weight support system. Proceedings of the 2009 IEEE\/RSJ International Conference on Intelligent Robots and Systems, St. Louis, MO, USA.","DOI":"10.1109\/IROS.2009.5354543"},{"key":"ref_17","first-page":"237","article-title":"Coordination evaluation of exoskeleton chair combined with motion capture","volume":"8","author":"Zhou","year":"2024","journal-title":"J. Mech. Des. Manuf."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Madhav, P.K., Mehdi, M.A., and Ehsan, R. (2023). A Systematic Review on Lower-Limb Industrial Exoskeletons: Evaluation Methods, Evidence, and Future Directions. Ann. Biomed. Eng., 51.","DOI":"10.1007\/s10439-023-03242-w"},{"key":"ref_19","first-page":"1230","article-title":"Configuration design and link length optimization of a variable-axis knee joint for lower limb exoskeletons","volume":"39","author":"Li","year":"2020","journal-title":"Mech. Sci. Technol. Aerosp. Eng."},{"key":"ref_20","unstructured":"Liu, Y., and Li, L. (2022). Research Methods in Biomechanics, Shanghai Jiao Tong University Press."},{"key":"ref_21","unstructured":"(2023). Human Body Dimensions of Chinese Adults (Standard No. GB\/T 10000-2023)."},{"key":"ref_22","first-page":"73","article-title":"Research on a lower limb pneumatic passive assistive exoskeleton device","volume":"40","author":"Ma","year":"2023","journal-title":"J. Mech. Des."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Sheng, W., Ghalichi, F., Ding, L., Yu, C., Lu, M., and Ye, X. (2025). Muscle Activation Reduction During Walking with an Active Hip Exoskeleton. Biomimetics, 10.","DOI":"10.3390\/biomimetics10010024"},{"key":"ref_24","first-page":"29","article-title":"Design of an upper limb exoskeleton rehabilitation training system based on surface electromyography signals","volume":"43","author":"Fu","year":"2024","journal-title":"Beijing Biomed. Eng."},{"key":"ref_25","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1016\/j.apergo.2019.05.018","article-title":"Influence of a Passive Lower-limb Exoskeleton During Simulated Industrial Work Tasks on Physical Load, Upper Body Posture, Postural Control and Discomfort","volume":"80","author":"Luger","year":"2019","journal-title":"Appl. Ergon."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Bennett, S.L., Goubran, R., Rockwood, K., and Knoefel, F. (2014, January 11\u201312). Distinguishing between stable and unstable sit-to-stand transfers using pressure sensors. Proceedings of the 2014 IEEE International Symposium on Medical Measurements and Applications (MeMeA), Lisbon, Portugal.","DOI":"10.1109\/MeMeA.2014.6860034"},{"key":"ref_27","doi-asserted-by":"crossref","unstructured":"Li, Z., Zhang, T., Xue, T., Du, Z., and Bai, O. (2019, January 27\u201330). Effect evaluation of a wearable exoskeleton chair based on surface EMG. Proceedings of the 2019 Chinese Control Conference (CCC), Guangzhou, China.","DOI":"10.23919\/ChiCC.2019.8865673"},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1177\/0018720820907752","article-title":"Evaluation of a lower leg support exoskeleton on floor and below hip height panel work","volume":"62","author":"Pillai","year":"2020","journal-title":"Hum. Factors"},{"key":"ref_29","doi-asserted-by":"crossref","unstructured":"Hong, Y.P., Koo, D., Park, J.I., Kim, S., and Kim, K.S. (October, January 28). The softgait: A simple and powerful weight-support device for walking and squatting. Proceedings of the 2015 IEEE International Conference on Intelligent Robots and Systems (IROS), Hamburg, Germany.","DOI":"10.1109\/IROS.2015.7354282"},{"key":"ref_30","unstructured":"Goyena, R., and Fallis, A.G. (2019, January 20\u201324). Mechanical framework design with experimental verification of a wearable exoskeleton chair. Proceedings of the 2019 International Conference on Robotics and Automation (ICRA), Montreal, QC, Canada."}],"container-title":["Biomimetics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2313-7673\/10\/5\/330\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T17:34:51Z","timestamp":1760031291000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2313-7673\/10\/5\/330"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,18]]},"references-count":30,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2025,5]]}},"alternative-id":["biomimetics10050330"],"URL":"https:\/\/doi.org\/10.3390\/biomimetics10050330","relation":{},"ISSN":["2313-7673"],"issn-type":[{"value":"2313-7673","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,18]]}}}