{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,16]],"date-time":"2026-05-16T07:35:12Z","timestamp":1778916912531,"version":"3.51.4"},"reference-count":33,"publisher":"MDPI AG","issue":"11","license":[{"start":{"date-parts":[[2025,11,19]],"date-time":"2025-11-19T00:00:00Z","timestamp":1763510400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Biomimetics"],"abstract":"<jats:p>Additive manufacturing has significantly advanced patient-specific medical devices, particularly for hard tissue repair, yet applications in soft tissue remain limited. Existing approaches for 3D-printed soft tissue devices employ mainly biogels and bioinks for regenerative purposes, while synthetic grafts for tendons and ligaments remain non-customizable in shape and mechanics. This study investigates the mechanical performance of 3D-printed thermoplastic polyurethane (TPU) elastomers as a function of printing parameters, informing customizable connective tissue graft designs. Type C dogbone specimens (n = 180) of three replicates each of parameter combinations from material shore hardness, presence of anchoring within the lattice, infill patterns, and infill density were printed and tested following modified ASTM D412 standards for vulcanized rubber and elastomers. The measured mechanical properties are elastic modulus, tensile yield stress, yield strain, ultimate tensile strength, and ultimate strain. Results show that shore hardness and infill density are the strongest predictors of mechanical properties, with positive but modest effects from anchor presence. Infill pattern is only significant through interactions, and its effects depend on other parameters. While all groups underperformed compared to manufacturer-reported TPU strengths and were well below in vitro tendon failure loads, findings highlight material selection and density optimization as critical early considerations for future patient-specific elastomeric graft design.<\/jats:p>","DOI":"10.3390\/biomimetics10110785","type":"journal-article","created":{"date-parts":[[2025,11,19]],"date-time":"2025-11-19T11:17:27Z","timestamp":1763551047000},"page":"785","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Three-Dimensional Printing Parameter Assessment of Elastomers for Tendon Graft Applications"],"prefix":"10.3390","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2494-3690","authenticated-orcid":false,"given":"Trent","family":"Lau","sequence":"first","affiliation":[{"name":"Department of Orthopedic Surgery, Duke University School of Medicine, Durham, NC 27710, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ashley","family":"Talwar","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Duke University Pratt School of Engineering, Durham, NC 27708, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5184-5762","authenticated-orcid":false,"given":"Bijan","family":"Abar","sequence":"additional","affiliation":[{"name":"Department of Emergency Medicine, Duke University School of Medicine, Durham, NC 27710, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1020-1167","authenticated-orcid":false,"given":"Samuel B.","family":"Adams","sequence":"additional","affiliation":[{"name":"Department of Orthopedic Surgery, Duke University School of Medicine, Durham, NC 27710, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2025,11,19]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1080\/03091902.2024.2399017","article-title":"Transformative applications of additive manufacturing in biomedical engineering: Bioprinting to surgical innovations","volume":"48","author":"Kennedy","year":"2024","journal-title":"J. Med. Eng. Technol."},{"key":"ref_2","doi-asserted-by":"crossref","unstructured":"Fang, W., Yang, M., Liu, M., Jin, Y., Wang, Y., Yang, R., Wang, Y., Zhang, K., and Fu, Q. (2023). Review on additives in hydrogels for 3D bioprinting of regenerative medicine: From mechanism to methodology. Pharmaceutics, 15.","DOI":"10.3390\/pharmaceutics15061700"},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"871","DOI":"10.2217\/rme-2016-0125","article-title":"The past, present and future of ligament regenerative engineering","volume":"11","author":"Mengsteab","year":"2016","journal-title":"Regen. Med."},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1007\/BF01845591","article-title":"Donor-site morbidity after harvest of a bone-tendon-bone patellar tendon autograft","volume":"2","author":"Kohn","year":"1994","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1080\/17434440.2022.2142557","article-title":"Implantable medical devices for tendon and ligament repair: A review of patents and commercial products","volume":"19","author":"Civera","year":"2022","journal-title":"Expert Rev. Med. Devices"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"2421","DOI":"10.1016\/j.jbiomech.2009.07.019","article-title":"Development of ligament tissue biodegradable devices: A review","volume":"42","author":"Vieira","year":"2009","journal-title":"J. Biomech."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1115\/1.2895466","article-title":"Effects of stress shielding on the mechanical properties of rabbit patellar tendon","volume":"115","author":"Yamamoto","year":"1993","journal-title":"J. Biomech. Eng."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/j.jhsa.2021.09.014","article-title":"Stress shielding of ligaments using nonabsorbable suture augmentation may influence the biology of ligament healing","volume":"47","author":"Nguyen","year":"2022","journal-title":"J. Hand Surg. Am."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1007\/s40964-017-0023-1","article-title":"The manufacture of 3D printing of medical grade TPU","volume":"2","author":"Xiao","year":"2017","journal-title":"Prog. Addit. Manuf."},{"key":"ref_10","unstructured":"Instron (2025, June 19). The Definitive Guide to ASTM D412 Tensile Testing of Elastomers. Available online: https:\/\/www.instron.com\/en\/testing-solutions\/astm-standards\/astm-d412."},{"key":"ref_11","unstructured":"International Organization for Standardization (2021). Part 10: Tests for skin sensitization. Biological Evaluation of Medical Devices, International Organization for Standardization. [4th ed.]."},{"key":"ref_12","unstructured":"International Organization for Standardization (2009). Part 5: Tests for in vitro cytotoxicity. Biological Evaluation of Medical Devices, International Organization for Standardization. [3rd ed.]."},{"key":"ref_13","unstructured":"International Organization for Standardization (2021). Part 23: Tests for irritation. Biological Evaluation of Medical Devices, International Organization for Standardization. [1st ed.]."},{"key":"ref_14","unstructured":"Siraya Tech (2025, September 27). Siraya Tech Flex TPU\u201485A Filament. Available online: https:\/\/siraya.tech\/products\/flex-tpu-85a-filament."},{"key":"ref_15","unstructured":"Wevolver (2025, June 19). TPU Glass Transition Temperature, Printing Temperature, and Other Thermal Considerations. Available online: https:\/\/www.wevolver.com\/article\/tpu-glass-transition-temperature-printing-temperature-and-other-thermal-considerations."},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1007\/s40964-023-00418-7","article-title":"The influence of printing parameters on the mechanical properties of 3D printed TPU-based elastomers","volume":"8","author":"Lion","year":"2023","journal-title":"Prog. Addit. Manuf."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"033601","DOI":"10.1117\/1.2714926","article-title":"Full-field strain measurement using a two-dimensional Savitzky\u2013Golay digital differentiator in digital image correlation","volume":"46","author":"Pan","year":"2007","journal-title":"Opt. Eng."},{"key":"ref_18","unstructured":"Michigan Technological University (2025, September 01). Tensile Test Experiment. Available online: https:\/\/www.mtu.edu\/materials\/k12\/experiments\/tensile\/."},{"key":"ref_19","doi-asserted-by":"crossref","first-page":"682","DOI":"10.1016\/j.procir.2022.02.114","article-title":"Compressive strength assessment of 3D printing infill patterns","volume":"105","author":"Pernet","year":"2022","journal-title":"Procedia CIRP"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1016\/j.matpr.2022.11.283","article-title":"Effect of infill pattern on fatigue characteristics of 3D printed polymers","volume":"78","author":"Dudescu","year":"2023","journal-title":"Mater. Today Proc."},{"key":"ref_21","doi-asserted-by":"crossref","unstructured":"Bakhtiari, H., Aamir, M., and Tolouei-Rad, M. (2023). Effect of 3D printing parameters on the fatigue properties of parts manufactured by fused filament fabrication: A review. Appl. Sci., 13.","DOI":"10.3390\/app13020904"},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1002\/jbm.a.37006","article-title":"3D printing of high-strength, porous, elastomeric structures to promote tissue integration of implants","volume":"109","author":"Abar","year":"2021","journal-title":"J. Biomed. Mater. Res. A"},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Alasfar, R.H., Ahzi, S., Barth, N., Kochkodan, V., Khraisheh, M., and Ko\u00e7, M. (2022). A review on the modeling of the elastic modulus and yield stress of polymers and polymer nanocomposites: Effect of temperature, loading rate and porosity. Polymers, 14.","DOI":"10.3390\/polym14030360"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"3875","DOI":"10.1021\/acs.macromol.3c01952","article-title":"Fracture behavior of polymers in plastic and elastomeric states","volume":"57","author":"Wang","year":"2024","journal-title":"Macromolecules"},{"key":"ref_25","unstructured":"Sovol3D Blog (2025, October 28). How Infill Percentage Affects Strength, Speed, and Filament Use. Available online: https:\/\/www.sovol3d.com\/blogs\/news\/infill-percentage-3d-printing-strength-filament."},{"key":"ref_26","unstructured":"ScienceDirect (2025, October 28). Gibson\u2013Ashby Model. Available online: https:\/\/www.sciencedirect.com\/topics\/engineering\/gibson-ashby-model."},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1002\/ca.10126","article-title":"Tensile properties of fresh human calcaneal (Achilles) tendons","volume":"17","author":"Leeson","year":"2004","journal-title":"Clin. Anat."},{"key":"ref_28","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/S0268-0033(00)00089-9","article-title":"Mechanical properties of the human Achilles tendon","volume":"16","author":"Wren","year":"2001","journal-title":"Clin. Biomech."},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1111\/j.1469-7793.1999.00307.x","article-title":"In vivo human tendon mechanical properties","volume":"521","author":"Maganaris","year":"1999","journal-title":"J. Physiol."},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"153","DOI":"10.22203\/eCM.v043a12","article-title":"Mechanical and strain behaviour of human Achilles tendon during in vitro testing to failure","volume":"43","author":"Nagelli","year":"2022","journal-title":"Eur. Cells Mater."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1243\/095441105X34239","article-title":"The influence of gripping techniques on the tensile properties of tendons","volume":"219","author":"Ng","year":"2005","journal-title":"Proc. Inst. Mech. Eng. H"},{"key":"ref_32","first-page":"36","article-title":"A study of the Achilles tendon while running","volume":"86","author":"Lucaciu","year":"2013","journal-title":"Clujul Med."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1327","DOI":"10.1108\/RPJ-08-2020-0205","article-title":"The influence of porosity, crystallinity and interlayer adhesion on the tensile strength of 3D printed polylactic acid (PLA)","volume":"27","author":"Collinson","year":"2021","journal-title":"Rapid Prototyp. J."}],"container-title":["Biomimetics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2313-7673\/10\/11\/785\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,19]],"date-time":"2025-11-19T11:57:27Z","timestamp":1763553447000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2313-7673\/10\/11\/785"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,19]]},"references-count":33,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2025,11]]}},"alternative-id":["biomimetics10110785"],"URL":"https:\/\/doi.org\/10.3390\/biomimetics10110785","relation":{},"ISSN":["2313-7673"],"issn-type":[{"value":"2313-7673","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,19]]}}}