{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T19:27:35Z","timestamp":1770751655796,"version":"3.50.0"},"reference-count":129,"publisher":"MDPI AG","issue":"2","license":[{"start":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T00:00:00Z","timestamp":1770681600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100002301","name":"Estonian Research Council, Estonia","doi-asserted-by":"publisher","award":["PRG643"],"award-info":[{"award-number":["PRG643"]}],"id":[{"id":"10.13039\/501100002301","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100002301","name":"Estonian Research Council, Estonia","doi-asserted-by":"publisher","award":["PSG1054"],"award-info":[{"award-number":["PSG1054"]}],"id":[{"id":"10.13039\/501100002301","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100002301","name":"Estonian Research Council, Estonia","doi-asserted-by":"publisher","award":["MNHA23020"],"award-info":[{"award-number":["MNHA23020"]}],"id":[{"id":"10.13039\/501100002301","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100002301","name":"Estonian Research Council, Estonia","doi-asserted-by":"publisher","award":["PRG3028"],"award-info":[{"award-number":["PRG3028"]}],"id":[{"id":"10.13039\/501100002301","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Biomimetics"],"abstract":"<jats:p>This first part of a two-part review examines how Computed Tomography(CT)-based, additively manufactured (AM) porous implants are used to reconstruct large segmental defects of the femur and tibia. We focus on lightweight patient-specific lattice implants, architected cages, and modular porous constructs that incorporate engineered porosity into the load-bearing structure and are deployed with plate-, nail-, or external-fixator-based stabilization. We show how defects are described and classified by size, morphology, and anatomical subsegment; how these descriptors influence fixation choice and the resulting mechanical environment; and where along the femur and tibia porous implants have been applied in clinical and preclinical settings. Across the literature, outcomes appear to depend most strongly on defect morphology and local biology, while fixation feasibility and construct behavior vary by subregional anatomy. Most reported constructs use Ti6Al4V porous architectures intended to share load with fixation, reduce stress shielding, and provide a regenerative space for graft and tissue ingrowth. Finite element analyses (FEA) and bench-top studies consistently indicate that lattice architecture, relative density (RD), and fixation concept jointly control stiffness, micromotion, and fatigue-sensitive regions, whereas early animal and human reports describe promising incorporation and functional recovery in selected cases. However, defect descriptors, fixation reporting, boundary conditions, and outcome metrics remain diverse, and explicit quantitative validation of simulations against mechanical or in vivo measurements is uncommon. Most published work relies on simulation and bench testing, with limited reporting of biological endpoints, leaving a validation gap that prevents direct translation. We emphasize the need for standardized defect and fixation descriptors, harmonized mechanical and modeling protocols, and defect-centered datasets that integrate anatomy, mechanics, and longitudinal outcomes. Across the 27 included studies (may be counted in more than one group), simulation and mechanical testing are reported in 19\/27 (70%) and 15\/27 (56%), respectively, while in vivo studies (preclinical or clinical) account for 9\/27 (33%), highlighting a validation gap that limits translation. Part 2 (under review); of these two series review paper; Patient-Specific Lattice Implants for Segmental Femoral and Tibial Reconstruction (Part 2): CT-Based Personalization, Design Workflows, and Validation-A Review; extends this work by detailing CT-to-implant workflows, lattice design strategies, and methodological validation.<\/jats:p>","DOI":"10.3390\/biomimetics11020128","type":"journal-article","created":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T11:16:38Z","timestamp":1770722198000},"page":"128","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Patient-Specific Lattice Implants for Segmental Femoral and Tibial Reconstruction (Part 1): Defect Patterns, Fixation Strategies and Reconstruction Options\u2014A Review"],"prefix":"10.3390","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6650-6467","authenticated-orcid":false,"given":"Mansoureh","family":"Rezapourian","sequence":"first","affiliation":[{"name":"Department of Mechanical and Industrial Engineering, Tallinn University of Technology, 19086 Tallinn, Estonia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-9713-8124","authenticated-orcid":false,"given":"Anooshe","family":"Sadat Mirhakimi","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, McMaster University, Hamilton, ON L8S 4L7, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-6647-8866","authenticated-orcid":false,"given":"Mahan","family":"Nematollahi","sequence":"additional","affiliation":[{"name":"Department of Technical Physics, University of Eastern Finland, 70210 Kuopio, Finland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2576-7040","authenticated-orcid":false,"given":"Tatevik","family":"Minasyan","sequence":"additional","affiliation":[{"name":"Department of Mechanical and Industrial Engineering, Tallinn University of Technology, 19086 Tallinn, Estonia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3081-2491","authenticated-orcid":false,"given":"Irina","family":"Hussainova","sequence":"additional","affiliation":[{"name":"Department of Mechanical and Industrial Engineering, Tallinn University of Technology, 19086 Tallinn, Estonia"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1968","published-online":{"date-parts":[[2026,2,10]]},"reference":[{"key":"ref_1","doi-asserted-by":"crossref","unstructured":"Marrara, G., Zampogna, B., Schick, V.D., Larizza, L., Rizzo, P., Sanzarello, I., Nanni, M., and Leonetti, D. (2024). Post-Traumatic Segmental Tibial Defects Management: A Systematic Review of the Literature. Appl. Sci., 15.","DOI":"10.3390\/app15010064"},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"7982","DOI":"10.1038\/s41598-024-58548-z","article-title":"Semi-focal bone transport versus traditional bone transport technique for the management of large tibial bone defects after trauma","volume":"14","author":"Wang","year":"2024","journal-title":"Sci. Rep."},{"key":"ref_3","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1111\/os.13604","article-title":"Induced Membrane Technique for the Management of Segmental Femoral Defects: A Systematic Review and Meta-Analysis of Individual Participant Data","volume":"15","author":"Lu","year":"2023","journal-title":"Orthop. Surg."},{"key":"ref_4","doi-asserted-by":"crossref","unstructured":"Schick, V.D., Zampogna, B., Marrara, G., Siracusano, L., Larizza, L., Calaciura, S., Sanzarello, I., Marinozzi, A., and Leonetti, D. (2025). Custom-Made 3D-Printed Titanium Implants for Managing Segmental Distal Tibial Bone Defects: A Systematic Literature Review. J. Clin. Med., 14.","DOI":"10.3390\/jcm14061796"},{"key":"ref_5","doi-asserted-by":"crossref","first-page":"1","DOI":"10.4055\/cios23294","article-title":"Patient-specific 3-dimensional-printed orthopedic implants and surgical devices are potential alternatives to conventional technology but require additional characterization","volume":"17","author":"McAnena","year":"2024","journal-title":"Clin. Orthop. Surg."},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"821","DOI":"10.1111\/os.14003","article-title":"3D-Printed personalized lattice implant as an innovative strategy to reconstruct geographic defects in load-bearing bones","volume":"16","author":"Li","year":"2024","journal-title":"Orthop. Surg."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"20417314241263689","DOI":"10.1177\/20417314241263689","article-title":"Novel 3D printed TPMS scaffolds: Microstructure, characteristics and applications in bone regeneration","volume":"15","author":"Ma","year":"2024","journal-title":"J. Tissue Eng."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1085","DOI":"10.1007\/s40964-024-00714-w","article-title":"Current status of the application of additive-manufactured TPMS structure in bone tissue engineering","volume":"10","author":"Wakjira","year":"2025","journal-title":"Prog. Addit. Manuf."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"105697","DOI":"10.1016\/j.rineng.2025.105697","article-title":"Bone-inspired lattice structures for biomedical applications: Design, pore network analysis, and mechanical performance","volume":"27","author":"Tauheed","year":"2025","journal-title":"Results Eng."},{"key":"ref_10","doi-asserted-by":"crossref","first-page":"e2530733","DOI":"10.1080\/17452759.2025.2530733","article-title":"Mechanical performance, fatigue behaviour, and biointegration of additively manufactured architected lattices","volume":"20","author":"Gandhi","year":"2025","journal-title":"Virtual Phys. Prototyp."},{"key":"ref_11","doi-asserted-by":"crossref","unstructured":"Alkentar, R., Kladovasilakis, N., Tzetzis, D., and Mankovits, T. (2023). Effects of pore size parameters of titanium additively manufactured lattice structures on the osseointegration process in orthopedic applications: A comprehensive review. Crystals, 13.","DOI":"10.3390\/cryst13010113"},{"key":"ref_12","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1177\/0954411912467884","article-title":"Patient-specific finite element modeling of bones","volume":"227","author":"Poelert","year":"2013","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"ref_13","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1002\/cnm.2530","article-title":"Accounting for patient variability in finite element analysis of the intact and implanted hip and knee: A review","volume":"29","author":"Taylor","year":"2013","journal-title":"Int. J. Numer. Methods Biomed. Eng."},{"key":"ref_14","doi-asserted-by":"crossref","first-page":"113668","DOI":"10.1016\/j.matdes.2025.113668","article-title":"Establishment of design guidelines for patient-specific 3D-printed reconstruction implants for large distal femoral defects","volume":"251","author":"Wu","year":"2025","journal-title":"Mater. Des."},{"key":"ref_15","doi-asserted-by":"crossref","unstructured":"Namvar, A., Lozanovski, B., Downing, D., Williamson, T., Kastrati, E., Shidid, D., Hill, D., Buehner, U., Ryan, S., and Choong, P.F. (2024). Finite element analysis of patient-specific additive-manufactured implants. Front. Bioeng. Biotechnol., 12.","DOI":"10.3389\/fbioe.2024.1386816"},{"key":"ref_16","doi-asserted-by":"crossref","first-page":"7497","DOI":"10.1097\/JS9.0000000000002944","article-title":"Clinical translation of 3D-printed patient-specific bone implants: A consensus statement","volume":"111","author":"Laubach","year":"2025","journal-title":"Int. J. Surg."},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"e016","DOI":"10.1097\/OI9.0000000000000016","article-title":"3D printed titanium cages combined with the Masquelet technique for the reconstruction of segmental femoral defects: Preliminary clinical results and molecular analysis of the biological activity of human-induced membranes","volume":"2","author":"Tetsworth","year":"2019","journal-title":"OTA Int."},{"key":"ref_18","doi-asserted-by":"crossref","first-page":"893","DOI":"10.1007\/s13770-023-00577-2","article-title":"Mechanics predicts effective critical-size bone regeneration using 3d-printed bioceramic scaffolds","volume":"20","author":"Morgaz","year":"2023","journal-title":"Tissue Eng. Regen. Med."},{"key":"ref_19","first-page":"89","article-title":"The Evolution of the Ilizarov Technique","volume":"71","author":"Goldstein","year":"2013","journal-title":"Bull. Hosp. Jt. Dis."},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/j.injury.2003.09.026","article-title":"Guidelines for the clinical application of the LCP","volume":"34","author":"Gautier","year":"2003","journal-title":"Injury"},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"257","DOI":"10.18321\/ectj1129","article-title":"Effect of Lattice Structure and Composite Precursor on Mechanical Properties of 3D-Printed Bone Scaffolds","volume":"23","author":"Shams","year":"2021","journal-title":"Eurasian-Chem.-Technol. J."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"1687814019883784","DOI":"10.1177\/1687814019883784","article-title":"Microstructure design and degradation performance in vitro of three-dimensional printed bioscaffold for bone tissue engineering","volume":"11","author":"Jin","year":"2019","journal-title":"Adv. Mech. Eng."},{"key":"ref_23","doi-asserted-by":"crossref","unstructured":"Verma, R., Kumar, J., Singh, N.K., Rai, S.K., Saxena, K.K., and Xu, J. (2022). Design and analysis of biomedical scaffolds using TPMS-based porous structures inspired from additive manufacturing. Coatings, 12.","DOI":"10.3390\/coatings12060839"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1186\/s13018-023-03612-z","article-title":"Design and performance analysis of 3D-printed stiffness gradient femoral scaffold","volume":"18","author":"Liu","year":"2023","journal-title":"J. Orthop. Surg. Res."},{"key":"ref_25","first-page":"214","article-title":"Additively manufactured metallic biomaterials","volume":"15","author":"Davoodi","year":"2022","journal-title":"Bioact. Mater."},{"key":"ref_26","doi-asserted-by":"crossref","unstructured":"Wu, P.K., Lee, C.W., Sun, W.H., and Lin, C.L. (2021). Biomechanical analysis and design method for patient-specific reconstructive implants for large bone defects of the distal lateral femur. Biosensors, 12.","DOI":"10.3390\/bios12010004"},{"key":"ref_27","doi-asserted-by":"crossref","first-page":"2590","DOI":"10.36922\/ijb.2590","article-title":"Optimizing implant lattice design for large distal femur defects: Stimulating interface bone growth to enhance osseointegration","volume":"10","author":"Chang","year":"2024","journal-title":"Int. J. Bioprinting"},{"key":"ref_28","doi-asserted-by":"crossref","unstructured":"Findeisen, S., Schwilk, M., Haubruck, P., Ferbert, T., Helbig, L., Miska, M., Schmidmaier, G., and Tanner, M.C. (2023). Matched-Pair Analysis: Large-Sized Defects in Surgery of Lower Limb Nonunions. J. Clin. Med., 12.","DOI":"10.3390\/jcm12134239"},{"key":"ref_29","doi-asserted-by":"crossref","first-page":"111130","DOI":"10.1016\/j.injury.2023.111130","article-title":"Management of segmental defects post open distal femur fracture using a titanium cage combined with the Masquelet technique A single-centre report of 23 cases","volume":"54","author":"Ma","year":"2023","journal-title":"Injury"},{"key":"ref_30","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1186\/s13018-023-03783-9","article-title":"Efficacy comparison of vascularized iliac crest bone flap and Ilizarov bone transport in the treatment of traumatic bone defects of the tibia combined with large soft tissue defects","volume":"18","author":"Cao","year":"2023","journal-title":"J. Orthop. Surg. Res."},{"key":"ref_31","doi-asserted-by":"crossref","first-page":"111465","DOI":"10.1016\/j.injury.2024.111465","article-title":"Can locking plate fixation and free Vascularised fibular transfer with skin island achieve good functional outcome in the treatment of large bone defects of Tibia? A study of 26 cases","volume":"55","author":"Dheenadhayalan","year":"2024","journal-title":"Injury"},{"key":"ref_32","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1186\/s13018-023-04356-6","article-title":"Docking site complications analysis of Ilizarov bone transport technique in the treatment of tibial bone defects","volume":"18","author":"Feng","year":"2023","journal-title":"J. Orthop. Surg. Res."},{"key":"ref_33","doi-asserted-by":"crossref","first-page":"1680","DOI":"10.1097\/CORR.0000000000003599","article-title":"Does Augmenting Irradiated Autografts With Free Vascularized Fibula Graft in Patients With Bone Loss From a Malignant Tumor Achieve Union, Function, and Complication Rate Comparably to Patients Without Bone Loss and Augmentation When Reconstructing Intercalary Resections in the Lower Extremity?","volume":"483","author":"Vahabi","year":"2025","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_34","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1097\/BOT.0000000000002928","article-title":"Consolidation of the Anteromedial Aspect of the Tibia Is Inferior to the Other Areas in the Reconstruction of Critical-Sized Bone Defect of the Tibial Shaft Using the Induced Membrane Technique: An Analysis of 111 Serial Computed Tomography of 37 Patients","volume":"39","author":"Son","year":"2025","journal-title":"J. Orthop. Trauma"},{"key":"ref_35","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1186\/s13018-023-03636-5","article-title":"Bifocal versus trifocal bone transport for the management of tibial bone defects caused by fracture-related infection: A meta-analysis","volume":"18","author":"Liu","year":"2023","journal-title":"J. Orthop. Surg. Res."},{"key":"ref_36","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1016\/j.injury.2023.01.029","article-title":"Acute shortening and double-level lengthening versus bone transport for the management of large tibial bone defects after trauma and infection","volume":"54","author":"Huang","year":"2023","journal-title":"Injury"},{"key":"ref_37","doi-asserted-by":"crossref","first-page":"807","DOI":"10.1016\/j.injury.2023.01.052","article-title":"Reconstruction of infected long bone defects: Issues and Challenges","volume":"54 3","author":"Papakostidis","year":"2023","journal-title":"Injury"},{"key":"ref_38","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1186\/s40001-021-00593-9","article-title":"Strategies for large bone defect reconstruction after trauma, infections or tumour excision: A comprehensive review of the literature","volume":"26","author":"Migliorini","year":"2021","journal-title":"Eur. J. Med. Res."},{"key":"ref_39","doi-asserted-by":"crossref","first-page":"S23","DOI":"10.1097\/BOT.0000000000000980","article-title":"Critical-Sized Bone Defects: Sequence and Planning","volume":"31","author":"Toogood","year":"2017","journal-title":"J. Orthop. Trauma"},{"key":"ref_40","doi-asserted-by":"crossref","first-page":"3877","DOI":"10.1007\/s00402-021-04299-9","article-title":"Three-stage limb salvage in tibial fracture related infection with composite bone and soft-tissue defect","volume":"142","author":"Corona","year":"2022","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"ref_41","doi-asserted-by":"crossref","first-page":"2248","DOI":"10.1016\/j.injury.2017.06.018","article-title":"Staged reconstruction of diaphyseal fractures with segmental defects: Surgical and patient-reported outcomes","volume":"48","author":"Zoller","year":"2017","journal-title":"Injury"},{"key":"ref_42","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.otsr.2018.11.012","article-title":"Very long-term results of post-traumatic bone defect reconstruction by the induced membrane technique","volume":"105","author":"Masquelet","year":"2019","journal-title":"Orthop. Traumatol. Surg. Res."},{"key":"ref_43","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.2106\/JBJS.RVW.M.00062","article-title":"Treatment of Traumatic Segmental Long-Bone Defects: A Critical Analysis Review","volume":"2","author":"Molina","year":"2014","journal-title":"JBJS Rev."},{"key":"ref_44","doi-asserted-by":"crossref","unstructured":"Chen, Z., Xing, Y., Li, X., Liu, B., Liu, N., Huo, Y., and Tian, Y. (2024). 3D-printed titanium porous prosthesis combined with the Masquelet technique for the management of large femoral bone defect caused by osteomyelitis. BMC Musculoskelet. Disord., 25.","DOI":"10.1186\/s12891-024-07576-x"},{"key":"ref_45","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1051\/sicotj\/2016043","article-title":"Putting 3D modelling and 3D printing into practice: Virtual surgery and preoperative planning to reconstruct complex post-traumatic skeletal deformities and defects","volume":"3","author":"Tetsworth","year":"2017","journal-title":"SICOT-J"},{"key":"ref_46","doi-asserted-by":"crossref","first-page":"2915","DOI":"10.1007\/s00264-018-3926-7","article-title":"Fixation augmentation using calcium-phosphate bone substitute improves outcomes of complex tibial plateau fractures. A matched, cohort study","volume":"42","author":"Ollivier","year":"2018","journal-title":"Int. Orthop."},{"key":"ref_47","doi-asserted-by":"crossref","first-page":"1739","DOI":"10.2106\/JBJS.23.01390","article-title":"Far Cortical Locking Versus Standard Constructs for Locked Plate Fixation in the Treatment of Acute, Displaced Fractures of the Distal Femur","volume":"106","author":"Lefaivre","year":"2024","journal-title":"J. Bone Jt. Surg."},{"key":"ref_48","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1097\/BOT.0000000000003047","article-title":"Outcomes of Nonunion Repair for Distal Femur Fracture","volume":"39","author":"Roddy","year":"2025","journal-title":"J. Orthop. Trauma"},{"key":"ref_49","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1097\/BOT.0000000000001362","article-title":"A Retrospective Comparative Cohort Study Comparing Temporary Internal Fixation to External Fixation at the First Stage Debridement in the Treatment of Type IIIB Open Diaphyseal Tibial Fractures","volume":"33","author":"Fowler","year":"2019","journal-title":"J. Orthop. Trauma"},{"key":"ref_50","doi-asserted-by":"crossref","first-page":"e03154","DOI":"10.1002\/adhm.202503154","article-title":"AI-Assisted Design and Evaluation of SLM-Ti64 Implants for Enhanced Bone Regeneration","volume":"14","author":"Zaheer","year":"2025","journal-title":"Adv. Healthc. Mater."},{"key":"ref_51","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1097\/BOT.0000000000002953","article-title":"Ring Fixator Bone Transport Is Associated With Fewer Unplanned Major Reoperations Than Masquelet in the Treatment of Segmental Bone Defects of the Tibia","volume":"39","author":"Whitlock","year":"2025","journal-title":"J. Orthop. Trauma"},{"key":"ref_52","doi-asserted-by":"crossref","first-page":"2319","DOI":"10.1007\/s00264-023-05865-z","article-title":"Clinical observation and finite element analysis of femoral stable interlocking intramedullary nail in intertrochanteric fractures","volume":"47","author":"Wu","year":"2023","journal-title":"Int. Orthop."},{"key":"ref_53","doi-asserted-by":"crossref","unstructured":"Wong, K.W., Wu, C.D., Chien, C.S., Lee, C.W., Yang, T.H., and Lin, C.L. (2020). Patient-specific 3-dimensional printing titanium implant biomechanical evaluation for complex distal femoral open fracture reconstruction with segmental large bone defect: A nonlinear finite element analysis. Appl. Sci., 10.","DOI":"10.3390\/app10124098"},{"key":"ref_54","doi-asserted-by":"crossref","first-page":"012096","DOI":"10.1088\/1757-899X\/402\/1\/012096","article-title":"Finite element analysis of scaffold for large defect in femur bone","volume":"402","author":"Karuppudaiyan","year":"2018","journal-title":"IOP Conf. Ser. Mater. Sci. Eng."},{"key":"ref_55","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/j.jmbbm.2018.08.034","article-title":"Nondestructive characterization of bone tissue scaffolds for clinical scenarios","volume":"89","author":"Entezari","year":"2019","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_56","doi-asserted-by":"crossref","first-page":"1453","DOI":"10.1177\/09544119211030715","article-title":"Design of patient specific bone stiffness mimicking scaffold","volume":"235","author":"Rana","year":"2021","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"ref_57","first-page":"3659","article-title":"Three-dimensional-printed individualized porous implants: A new \u201cimplant-bone\u201d interface fusion concept for large bone defect treatment","volume":"6","author":"Zhang","year":"2021","journal-title":"Bioact. Mater."},{"key":"ref_58","doi-asserted-by":"crossref","first-page":"eaam8828","DOI":"10.1126\/scitranslmed.aam8828","article-title":"Mechanobiologically optimized 3D titanium-mesh scaffolds enhance bone regeneration in critical segmental defects in sheep","volume":"10","author":"Pobloth","year":"2018","journal-title":"Sci. Transl. Med."},{"key":"ref_59","doi-asserted-by":"crossref","unstructured":"Obaton, A.F., Fain, J., Meinel, D., Tsamos, A., L\u00e9onard, F., L\u00e9cuelle, B., and Djema\u00ef, M. (2023). In vivo bone progression in and around lattice implants additively manufactured with a new titanium alloy. Appl. Sci., 13.","DOI":"10.20944\/preprints202305.1280.v1"},{"key":"ref_60","doi-asserted-by":"crossref","first-page":"2764","DOI":"10.35940\/ijeat.A9769.109119","article-title":"Design of scaffold with controlled internal architecture using fused deposition modeling (FDM)","volume":"9","author":"Karuppudaiyan","year":"2019","journal-title":"Int. J. Eng. Adv. Technol."},{"key":"ref_61","doi-asserted-by":"crossref","first-page":"2700","DOI":"10.1016\/j.jbiomech.2014.05.006","article-title":"Mechanical analysis of a rodent segmental bone defect model: The effects of internal fixation and implant stiffness on load transfer","volume":"47","author":"Yavari","year":"2014","journal-title":"J. Biomech."},{"key":"ref_62","doi-asserted-by":"crossref","first-page":"213617","DOI":"10.1016\/j.bioadv.2023.213617","article-title":"3D-printed LEGO\u00ae-inspired titanium scaffolds for patient-specific regenerative medicine","volume":"154","author":"Lee","year":"2023","journal-title":"Biomater. Adv."},{"key":"ref_63","first-page":"283","article-title":"Bio-printing of femur model: A bone substitute for biomedical research","volume":"57","author":"Vasanthanathan","year":"2023","journal-title":"Mater. Technol."},{"key":"ref_64","doi-asserted-by":"crossref","first-page":"S40","DOI":"10.1016\/S0020-1383(17)30793-3","article-title":"Influence of gap size, screw configuration, and nail materials in the stability of anterograde reamed intramedullary nail in femoral transverse fractures","volume":"48","author":"Gabarre","year":"2017","journal-title":"Injury"},{"key":"ref_65","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1016\/j.bone.2012.11.005","article-title":"Design and optimization of the oriented groove on the hip implant surface to promote bone microstructure integrity","volume":"52","author":"Noyama","year":"2013","journal-title":"Bone"},{"key":"ref_66","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1186\/s13018-020-01636-3","article-title":"J-bone graft with double locking plate: A symphony of mechanics and biology for atrophic distal femoral non-union with bone defect","volume":"15","author":"Lu","year":"2020","journal-title":"J. Orthop. Surg. Res."},{"key":"ref_67","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1186\/s13018-018-0792-3","article-title":"Comparing case-control study for treatment of proximal tibia fractures with a complete metaphyseal component in two centers with different distinct strategies: Fixation with Ilizarov frame or locking plates","volume":"13","author":"Berven","year":"2018","journal-title":"J. Orthop. Surg. Res."},{"key":"ref_68","doi-asserted-by":"crossref","first-page":"1774","DOI":"10.1002\/jor.23445","article-title":"Fully porous 3D printed titanium femoral stem to reduce stress-shielding following total hip arthroplasty","volume":"35","author":"Arabnejad","year":"2017","journal-title":"J. Orthop. Res."},{"key":"ref_69","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/j.jbiomech.2017.08.017","article-title":"Improving stress shielding following total hip arthroplasty by using a femoral stem made of \u03b2 type Ti-33.6Nb-4Sn with a Young\u2019s modulus gradation","volume":"63","author":"Yamako","year":"2017","journal-title":"J. Biomech."},{"key":"ref_70","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1097\/01.blo.0000246541.41951.20","article-title":"New femoral designs: Do they influence stress shielding?","volume":"453","author":"Glassman","year":"2006","journal-title":"Clin. Orthop. Relat. Res."},{"key":"ref_71","first-page":"1","article-title":"Metals for bone implants: Safety, design, and efficacy","volume":"1","year":"2016","journal-title":"Biomanufacturing Rev."},{"key":"ref_72","doi-asserted-by":"crossref","first-page":"1481","DOI":"10.1016\/j.medengphy.2016.09.018","article-title":"Stress shielding in periprosthetic bone following a total knee replacement: Effects of implant material, design and alignment","volume":"38","author":"Zhang","year":"2016","journal-title":"Med. Eng. Phys."},{"key":"ref_73","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/j.actbio.2023.11.011","article-title":"The role of stiffness-matching in avoiding stress shielding-induced bone loss and stress concentration-induced skeletal reconstruction device failure","volume":"173","author":"Chmielewska","year":"2024","journal-title":"Acta Biomater."},{"key":"ref_74","doi-asserted-by":"crossref","unstructured":"Ceddia, M., Morizio, A., Solarino, G., and Trentadue, B. (2025). Evaluation of the Stress-Shielding Effect of a PEEK Knee Prosthesis: A Finite Element Study. Osteology, 5.","DOI":"10.3390\/osteology5030024"},{"key":"ref_75","doi-asserted-by":"crossref","first-page":"2325967120S0032","DOI":"10.1177\/2325967120S00322","article-title":"Patients outcome after distal femur- and proximal tibia replacement","volume":"8","author":"Graulich","year":"2020","journal-title":"Orthop. J. Sport. Med."},{"key":"ref_76","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.artd.2020.11.014","article-title":"Distal Femoral Replacements for Acute Comminuted Periprosthetic Knee Fractures: Satisfactory Clinical Outcomes at Medium-Term Follow-up","volume":"7","author":"Matar","year":"2021","journal-title":"Arthroplast. Today"},{"key":"ref_77","doi-asserted-by":"crossref","first-page":"111185","DOI":"10.1016\/j.injury.2023.111185","article-title":"Mechanical outcomes of the TFNA, InterTAN and IMHS intramedullary nailing systems for the fixation of proximal femur fractures","volume":"55","author":"McAleese","year":"2024","journal-title":"Injury"},{"key":"ref_78","unstructured":"Stadelmann, V. (2008). Prevention of Micromotion-Related Periprosthetic Bone Loss Using Local Release of Bisphosphonate: Theoretical Developments and Experimental Validations. [Ph.D. Thesis, EPFL\u2014Swiss Federal Technology Institute of Lausanne]."},{"key":"ref_79","first-page":"47","article-title":"Total ankle replacement design and positioning affect implant-bone micromotion and bone strains","volume":"47","author":"Sopher","year":"2017","journal-title":"Med. Eng. Phys."},{"key":"ref_80","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1007\/s00167-020-05985-8","article-title":"Factors predicting repeat revision and outcome after aseptic revision total knee arthroplasty: Results from the New Zealand Joint Registry","volume":"29","author":"Klasan","year":"2020","journal-title":"Knee Surg. Sport. Traumatol. Arthrosc."},{"key":"ref_81","doi-asserted-by":"crossref","unstructured":"Nolte, P.C., Schlentrich, K., Raisch, P., Jung, M.K., Gr\u00fctzner, P.A., and Bischel, O. (2023). Survival and Clinical Outcomes after Unconstrained Total Knee Arthroplasty for Tibial Plateau Fractures\u2013A Retrospective Study with Minimum 4-Year Follow-Up. J. Clin. Med., 12.","DOI":"10.3390\/jcm12237303"},{"key":"ref_82","doi-asserted-by":"crossref","unstructured":"Rissolio, L., Sabatini, L., Risitano, S., Bistolfi, A., Galluzzo, U., Mass\u00e8, A., and Indelli, P.F. (2021). Is It the Surgeon, the Patient, or the Device? A Comprehensive Clinical and Radiological Evaluation of Factors Influencing Patient Satisfaction in 648 Total Knee Arthroplasties. J. Clin. Med., 10.","DOI":"10.3390\/jcm10122599"},{"key":"ref_83","doi-asserted-by":"crossref","unstructured":"Weis, S., Seifert, L., Oltmanns, M., Khury, F., Bieger, R., and Faschingbauer, M. (2024). The Etiology of Total Knee Arthroplasty Failure Influences on Improvement in Knee Function: A Follow-Up Study. J. Clin. Med., 13.","DOI":"10.3390\/jcm13247672"},{"key":"ref_84","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1016\/j.medengphy.2012.06.006","article-title":"Finite element analysis on the biomechanical stability of open porous titanium scaffolds for large segmental bone defects under physiological load conditions","volume":"35","author":"Wieding","year":"2013","journal-title":"Med. Eng. Phys."},{"key":"ref_85","doi-asserted-by":"crossref","first-page":"1053","DOI":"10.1016\/j.medengphy.2015.08.007","article-title":"Implementation of boundary conditions in modeling the femur is critical for the evaluation of distal intramedullary nailing","volume":"37","author":"Bayoglu","year":"2015","journal-title":"Med. Eng. Phys."},{"key":"ref_86","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1016\/j.actbio.2020.03.016","article-title":"Custom-made macroporous bioceramic implants based on triply-periodic minimal surfaces for bone defects in load-bearing sites","volume":"109","author":"Charbonnier","year":"2020","journal-title":"Acta Biomater."},{"key":"ref_87","doi-asserted-by":"crossref","first-page":"104380","DOI":"10.1016\/j.jmbbm.2021.104380","article-title":"Functional repair of critically sized femoral defects treated with bioinspired titanium gyroid-sheet scaffolds","volume":"116","author":"Kelly","year":"2021","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_88","doi-asserted-by":"crossref","unstructured":"Lee, M.C., Pan, C.T., Chen, W.F., Lin, M.C., and Shiue, Y.L. (2024). Design, manufacture, and characterization of a critical-sized gradient porosity dual-material tibial defect scaffold. Bioengineering, 11.","DOI":"10.3390\/bioengineering11040308"},{"key":"ref_89","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1007\/s42242-023-00259-x","article-title":"Customized scaffolds for large bone defects using 3D-printed modular blocks from 2D-medical images","volume":"7","author":"Acar","year":"2024","journal-title":"Bio-Des. Manuf."},{"key":"ref_90","first-page":"1883","article-title":"Biomechanical Study of Different Scaffold Designs for Reconstructing a Traumatic Distal Femur Defect Using Patient-Specific Computational Modeling","volume":"142","author":"Lu","year":"2025","journal-title":"Comput. Model. Eng. Sci. (CMES)"},{"key":"ref_91","doi-asserted-by":"crossref","first-page":"111605","DOI":"10.1016\/j.matdes.2023.111605","article-title":"Patient-specific Ti-6Al-4V lattice implants for critical-sized load-bearing bone defects reconstruction","volume":"226","author":"Benady","year":"2023","journal-title":"Mater. Des."},{"key":"ref_92","doi-asserted-by":"crossref","first-page":"10808","DOI":"10.1038\/s41598-024-61305-x","article-title":"Effect of different constraining boundary conditions on simulated femoral stresses and strains during gait","volume":"14","author":"Bavil","year":"2024","journal-title":"Sci. Rep."},{"key":"ref_93","doi-asserted-by":"crossref","unstructured":"Scheiner, S., and Hellmich, C. (2017). Patient-specific design of tissue engineering scaffolds, based on mathematical modeling. Advances in Ceramic Biomaterials, Woodhead Publishing.","DOI":"10.1016\/B978-0-08-100881-2.00013-0"},{"key":"ref_94","doi-asserted-by":"crossref","unstructured":"Laubach, M., Hildebrand, F., Suresh, S., Wagels, M., Kobbe, P., Gilbert, F., Kneser, U., Holzapfel, B.M., and Hutmacher, D.W. (2023). The concept of scaffold-guided bone regeneration for the treatment of long bone defects: Current clinical application and future perspective. J. Funct. Biomater., 14.","DOI":"10.3390\/jfb14070341"},{"key":"ref_95","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1002\/cnm.2536","article-title":"Patient-specific modelling of bone and bone-implant systems: The challenges","volume":"29","author":"Pankaj","year":"2013","journal-title":"Int. J. Numer. Methods Biomed. Eng."},{"key":"ref_96","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1002\/jbm.820040407","article-title":"Preliminary evaluation of porous metal surfaced titanium for orthopedic implants","volume":"4","author":"Hahn","year":"1970","journal-title":"J. Biomed. Mater. Res."},{"key":"ref_97","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1002\/jbm.820070305","article-title":"Fiber metal composites in the fixation of skeletal prosthesis","volume":"7","author":"Galante","year":"1973","journal-title":"J. Biomed. Mater. Res."},{"key":"ref_98","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/S0883-5403(87)80024-4","article-title":"Historical review of porous-coated implants","volume":"2","author":"Spector","year":"1987","journal-title":"J. Arthroplast."},{"key":"ref_99","doi-asserted-by":"crossref","unstructured":"Fabi, D., and Levine, B. (2012). Porous coatings on metallic implant materials. Materials for Medical Devices, ASM International.","DOI":"10.31399\/asm.hb.v23.a0005656"},{"key":"ref_100","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1302\/0301-620X.69B1.3818732","article-title":"Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results","volume":"69","author":"Engh","year":"1987","journal-title":"J. Bone Jt. Surg. Br."},{"key":"ref_101","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1016\/0883-5403(92)90040-W","article-title":"Porous-coated anatomic (PCA) knee arthroplasty: 3-Year results","volume":"7","author":"Eskola","year":"1992","journal-title":"J. Arthroplast."},{"key":"ref_102","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1007\/s00264-007-0505-8","article-title":"A long-term follow-up study of the cementless THA with anatomic stem\/HGPII cup with 22-mm head","volume":"33","author":"Nakoshi","year":"2009","journal-title":"Int. Orthop."},{"key":"ref_103","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1016\/S0883-5403(98)80013-2","article-title":"Revision total knee arthroplasty using the porous-coated anatomic revision prosthesis: Six-to twelve-year results","volume":"13","author":"Mow","year":"1998","journal-title":"J. Arthroplast."},{"key":"ref_104","doi-asserted-by":"crossref","first-page":"108353","DOI":"10.1016\/j.ijmecsci.2023.108353","article-title":"Selective laser melted Ti6Al4V split-P TPMS lattices for bone tissue engineering","volume":"251","author":"Rezapourian","year":"2023","journal-title":"Int. J. Mech. Sci."},{"key":"ref_105","doi-asserted-by":"crossref","first-page":"106977","DOI":"10.1016\/j.ijmecsci.2021.106977","article-title":"Enhancement in the mechanical behaviour of a Schwarz Primitive periodic minimal surface lattice structure design","volume":"216","author":"Guo","year":"2022","journal-title":"Int. J. Mech. Sci."},{"key":"ref_106","doi-asserted-by":"crossref","unstructured":"Li, Y., Jiang, D., Zhao, R., Wang, X., Wang, L., and Zhang, L.C. (2024). High mechanical performance of lattice structures fabricated by additive manufacturing. Metals, 14.","DOI":"10.3390\/met14101165"},{"key":"ref_107","doi-asserted-by":"crossref","first-page":"100606","DOI":"10.1016\/j.mser.2021.100606","article-title":"Architected cellular materials: A review on their mechanical properties towards fatigue-tolerant design and fabrication","volume":"144","author":"Benedetti","year":"2021","journal-title":"Mater. Sci. Eng. R Rep."},{"key":"ref_108","doi-asserted-by":"crossref","first-page":"105370","DOI":"10.1016\/j.jmbbm.2022.105370","article-title":"Biomimetic design of implants for long bone critical-sized defects","volume":"134","author":"Rezapourian","year":"2022","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_109","doi-asserted-by":"crossref","first-page":"2200558","DOI":"10.1002\/mame.202200558","article-title":"Biomimetic polycaprolactone-graphene oxide composites for 3D printing bone scaffolds","volume":"308","author":"Rahmati","year":"2023","journal-title":"Macromol. Mater. Eng."},{"key":"ref_110","doi-asserted-by":"crossref","first-page":"2429","DOI":"10.1007\/s11831-024-10212-5","article-title":"An overview of design and development of biomimetic bone scaffolds using heterogeneous TPMS lattice structures","volume":"32","author":"Mall","year":"2024","journal-title":"Arch. Comput. Methods Eng."},{"key":"ref_111","doi-asserted-by":"crossref","first-page":"106232","DOI":"10.1016\/j.jmbbm.2023.106232","article-title":"Optimal mechanical properties of Hydroxyapatite gradient Voronoi porous scaffolds for bone applications\u2014A numerical study","volume":"148","author":"Rezapourian","year":"2023","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"ref_112","doi-asserted-by":"crossref","first-page":"9892689","DOI":"10.34133\/2021\/9892689","article-title":"Fractal design boosts extrusion-based 3D printing of bone-mimicking radial-gradient scaffolds","volume":"2021","author":"Qu","year":"2021","journal-title":"Research"},{"key":"ref_113","doi-asserted-by":"crossref","first-page":"012005","DOI":"10.1088\/1758-5090\/ad905f","article-title":"Shape\/properties collaborative intelligent manufacturing of artificial bone scaffold: Structural design and additive manufacturing process","volume":"17","author":"Feng","year":"2024","journal-title":"Biofabrication"},{"key":"ref_114","doi-asserted-by":"crossref","unstructured":"Rezapourian, M., Cheloee Darabi, A., Khoshbin, M., and Hussainova, I. (2025). Multi-Objective Machine Learning Optimization of Cylindrical TPMS Lattices for Bone Implants. Biomimetics, 10.","DOI":"10.3390\/biomimetics10070475"},{"key":"ref_115","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1016\/j.polymer.2017.11.049","article-title":"Insights into the mechanical properties of several triply periodic minimal surface lattice structures made by polymer additive manufacturing","volume":"152","author":"Maskery","year":"2018","journal-title":"Polymer"},{"key":"ref_116","unstructured":"Kadkhodapour, J., Schmauder, S., and Sajadi, F. (2022). Quality Analysis of Additively Manufactured Metals: Simulation Approaches, Processes, and Microstructure Properties, Elsevier."},{"key":"ref_117","doi-asserted-by":"crossref","first-page":"222","DOI":"10.3176\/proc.2025.2.25","article-title":"Mechanical analysis of multi-surface TPMS lattices for bone applications","volume":"74","author":"Rezapourian","year":"2025","journal-title":"Proc. Est. Acad. Sci."},{"key":"ref_118","doi-asserted-by":"crossref","unstructured":"Lu, Y., Cheng, L., Yang, Z., Li, J., and Zhu, H. (2020). Relationship between the morphological, mechanical and permeability properties of porous bone scaffolds and the underlying microstructure. PLoS ONE, 15.","DOI":"10.1371\/journal.pone.0238471"},{"key":"ref_119","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1080\/14686996.2021.1907222","article-title":"Mechanical properties and fluid permeability of gyroid and diamond lattice structures for intervertebral devices: Functional requirements and comparative analysis","volume":"22","author":"Timercan","year":"2021","journal-title":"Sci. Technol. Adv. Mater."},{"key":"ref_120","doi-asserted-by":"crossref","unstructured":"Toosi, S., Javid-Naderi, M.J., Tamayol, A., Ebrahimzadeh, M.H., Yaghoubian, S., and Mousavi Shaegh, S.A. (2024). Additively manufactured porous scaffolds by design for treatment of bone defects. Front. Bioeng. Biotechnol., 11.","DOI":"10.3389\/fbioe.2023.1252636"},{"key":"ref_121","doi-asserted-by":"crossref","first-page":"2126","DOI":"10.1016\/j.jmrt.2024.06.234","article-title":"Laser powder bed fusion of bio-inspired metamaterials for energy absorption applications: A review","volume":"31","author":"Dubey","year":"2024","journal-title":"J. Mater. Res. Technol."},{"key":"ref_122","doi-asserted-by":"crossref","first-page":"2108","DOI":"10.1016\/j.bjps.2022.02.057","article-title":"Regenerative matching axial vascularisation of absorbable 3D-printed scaffold for large bone defects: A first in human series","volume":"75","author":"Castrisos","year":"2022","journal-title":"J. Plast. Reconstr. Aesthetic Surg."},{"key":"ref_123","doi-asserted-by":"crossref","first-page":"eadd6071","DOI":"10.1126\/sciadv.add6071","article-title":"Convergence of scaffold-guided bone regeneration principles and microvascular tissue transfer surgery","volume":"9","author":"Sparks","year":"2023","journal-title":"Sci. Adv."},{"key":"ref_124","doi-asserted-by":"crossref","first-page":"e056440","DOI":"10.1136\/bmjopen-2021-056440","article-title":"Protocol for the BONE-RECON trial: A single-arm feasibility trial for critical sized lower limb BONE defect RECONstruction using the mPCL-TCP scaffold system with autologous vascularised corticoperiosteal tissue transfer","volume":"13","author":"Sparks","year":"2023","journal-title":"BMJ Open"},{"key":"ref_125","doi-asserted-by":"crossref","first-page":"4100","DOI":"10.1016\/j.jmrt.2025.08.251","article-title":"Towards sustainable additive manufacturing: Enhanced productivity via numerical-experimental melt pool engineering in laser powder bed fusion of Ti-alloy","volume":"38","author":"Hasanabadi","year":"2025","journal-title":"J. Mater. Res. Technol."},{"key":"ref_126","first-page":"104811","article-title":"Laser powder bed fusion of difficult-to-print \u03b3 Ni-based superalloys: A review of processing approaches, properties, and remaining challenges","volume":"106","author":"Enrique","year":"2025","journal-title":"Addit. Manuf."},{"key":"ref_127","doi-asserted-by":"crossref","first-page":"21128","DOI":"10.1016\/j.ceramint.2020.05.189","article-title":"Selective laser melting of TiB2-Ti composite with high content of ceramic phase","volume":"46","author":"Liu","year":"2020","journal-title":"Ceram. Int."},{"key":"ref_128","doi-asserted-by":"crossref","unstructured":"Kadkhodapour, J., Mirhakimi, A.S., and Montazerian, H. (2023). Structural defects and mechanical properties of additively manufactured parts. Quality Analysis of Additively Manufactured Metals, Elsevier.","DOI":"10.1016\/B978-0-323-88664-2.00006-3"},{"key":"ref_129","doi-asserted-by":"crossref","unstructured":"Minasyan, T., and Hussainova, I. (2022). Laser powder-bed fusion of ceramic particulate reinforced aluminum alloys: A review. Materials, 15.","DOI":"10.3390\/ma15072467"}],"container-title":["Biomimetics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2313-7673\/11\/2\/128\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T11:57:21Z","timestamp":1770724641000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2313-7673\/11\/2\/128"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,10]]},"references-count":129,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2026,2]]}},"alternative-id":["biomimetics11020128"],"URL":"https:\/\/doi.org\/10.3390\/biomimetics11020128","relation":{},"ISSN":["2313-7673"],"issn-type":[{"value":"2313-7673","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,10]]}}}