{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T19:58:26Z","timestamp":1790279906890,"version":"4.1.0"},"reference-count":26,"publisher":"MDPI AG","issue":"5","license":[{"start":{"date-parts":[[2025,5,20]],"date-time":"2025-05-20T00:00:00Z","timestamp":1747699200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Biosensors"],"abstract":"<jats:p>We present a hermetically sealed capacitive microelectromechanical system (MEMS) strain sensor designed for arterial pulse waveform extraction using the strain plethysmography (SPG) modality. The MEMS strain sensor features a small form factor of 3.3 mm \u00d7 3.3 mm \u00d7 1 mm, leverages a nano-gap fabrication process to improve the sensitivity, and uses a differential sensing mechanism to improve the linearity and remove the common mode drift. The MEMS strain sensor is interfaced with an application-specific integrated circuit (ASIC) to form a compact strain sensing system. This system exhibits a high strain sensitivity of 316 aF\/\u00b5\u03b5, a gauge factor (GF) of 35, and a strain sensing resolution of 1.26 \u00b5\u03b5, while maintaining a linear range exceeding 700 \u00b5\u03b5. SPG signals have been reliably captured at both the fingertip and wrist using the MEMS strain sensor with high signal quality, preserving various photoplethysmography (PPG) features. Experimental results demonstrate that heart rate (HR) and heart rate variability (HRV) can be estimated from the SPG signal collected at the fingertip and wrist using the sensor with an accuracy of over 99%. Pulse arrival time (PAT) and pulse transit time (PTT) have been successfully extracted using the sensor together with a MEMS seismometer, showcasing its potential for ambulatory BP monitoring (ABPM) application.<\/jats:p>","DOI":"10.3390\/bios15050325","type":"journal-article","created":{"date-parts":[[2025,5,20]],"date-time":"2025-05-20T04:48:18Z","timestamp":1747716498000},"page":"325","update-policy":"https:\/\/doi.org\/10.3390\/mdpi_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Strain Plethysmography Using a Hermetically Sealed MEMS Strain Sensor"],"prefix":"10.3390","volume":"15","author":[{"given":"Xinyu","family":"Jiang","sequence":"first","affiliation":[{"name":"School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9054-8958","authenticated-orcid":false,"given":"Brian","family":"Sang","sequence":"additional","affiliation":[{"name":"School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haoran","family":"Wen","sequence":"additional","affiliation":[{"name":"StethX Microsystems Inc., Atlanta, GA 30308, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregory","family":"Junek","sequence":"additional","affiliation":[{"name":"StethX Microsystems Inc., Atlanta, GA 30308, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin-Woo","family":"Park","sequence":"additional","affiliation":[{"name":"StethX Microsystems Inc., Atlanta, GA 30308, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Farrokh","family":"Ayazi","sequence":"additional","affiliation":[{"name":"School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA"},{"name":"StethX Microsystems Inc., Atlanta, GA 30308, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1968","published-online":{"date-parts":[[2025,5,20]]},"reference":[{"key":"ref_1","first-page":"82","article-title":"Electrocardiography","volume":"1","author":"Mirvis","year":"2001","journal-title":"Heart Dis."},{"key":"ref_2","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1007\/s13246-018-0637-8","article-title":"Study of continuous blood pressure estimation based on pulse transit time, heart rate and photoplethysmography-derived hemodynamic covariates","volume":"41","author":"Feng","year":"2018","journal-title":"Australas. Phys. Eng. Sci. Med."},{"key":"ref_3","first-page":"33","article-title":"Continuous Blood Pressure Estimation from PPG Signal","volume":"42","author":"Marinko","year":"2024","journal-title":"Informatica"},{"key":"ref_4","doi-asserted-by":"crossref","first-page":"64","DOI":"10.3390\/vibration2010005","article-title":"Recent Advances in Seismocardiography","volume":"2","author":"Taebi","year":"2019","journal-title":"Vibration"},{"key":"ref_5","doi-asserted-by":"crossref","unstructured":"Liu, Z., Zhang, Y., and Zhou, C. (2024). BiGRU-attention for Continuous blood pressure trends estimation through single channel PPG. Comput. Biol. Med., 168.","DOI":"10.1016\/j.compbiomed.2023.107795"},{"key":"ref_6","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.bja.2020.09.049","article-title":"Cardiac output estimation using pulse wave analysis\u2014Physiology, algorithms, and technologies: A narrative review","volume":"126","author":"Saugel","year":"2021","journal-title":"Br. J. Anaesth."},{"key":"ref_7","doi-asserted-by":"crossref","first-page":"2699","DOI":"10.1109\/JBHI.2024.3372968","article-title":"MEMS Fingertip Strain Plethysmography for Cuffless Estimation of Blood Pressure","volume":"28","author":"Shokouhmand","year":"2024","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_8","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1113\/jphysiol.1953.sp004926","article-title":"The measurement of volume changes in human limbs","volume":"121","author":"Whitney","year":"1953","journal-title":"J. Physiol."},{"key":"ref_9","doi-asserted-by":"crossref","first-page":"5921","DOI":"10.1109\/JSEN.2020.2973342","article-title":"A Novel Approach to Acquire the Arterial Pulse by Finger Plethysmography Using Fiber Bragg Grating Sensor","volume":"20","author":"Pant","year":"2020","journal-title":"IEEE Sens. J."},{"key":"ref_10","doi-asserted-by":"crossref","unstructured":"Wang, Y.-J., Chen, C.-H., Sue, C.-Y., Lu, W.-H., and Chiou, Y.-H. (2018). Estimation of Blood Pressure in the Radial Artery Using Strain-Based Pulse Wave and Photoplethysmography Sensors. Micromachines, 9.","DOI":"10.3390\/mi9110556"},{"key":"ref_11","doi-asserted-by":"crossref","first-page":"6954","DOI":"10.1002\/adma.201502535","article-title":"A Sensitive and Biodegradable Pressure Sensor Array for Cardiovascular Monitoring","volume":"27","author":"Boutry","year":"2015","journal-title":"Adv. Mater."},{"key":"ref_12","doi-asserted-by":"crossref","unstructured":"Sang, B., Wen, H., Junek, G., Neveu, W., Di Francesco, L., and Ayazi, F. (2024). An Accelerometer-Based Wearable Patch for Robust Respiratory Rate and Wheeze Detection Using Deep Learning. Biosensors, 14.","DOI":"10.3390\/bios14030118"},{"key":"ref_13","doi-asserted-by":"crossref","unstructured":"Tadi, M.J., Lehtonen, E., Pank\u00e4\u00e4l\u00e4, M., Saraste, A., Vasankari, T., Ter\u00e1s, M., and Koivisto, T. (2016, January 16\u201320). Gyrocardiography: A new non-invasive approach in the study of mechanical motions of the heart. Concept, method and initial observations. Proceedings of the 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Lake Buena Vista, FL, USA.","DOI":"10.1109\/EMBC.2016.7591126"},{"key":"ref_14","doi-asserted-by":"crossref","unstructured":"Sun, Y., Dong, Y., Gao, R., Chu, Y., Zhang, M., Qian, X., and Wang, X. (2018). Wearable Pulse Wave Monitoring System Based on MEMS Sensors. Micromachines, 9.","DOI":"10.3390\/mi9020090"},{"key":"ref_15","doi-asserted-by":"crossref","first-page":"1069","DOI":"10.1109\/JMEMS.2006.881489","article-title":"A High-Performance MEMS Capacitive Strain Sensing System","volume":"15","author":"Suster","year":"2006","journal-title":"J. Microelectromech. Syst."},{"key":"ref_16","doi-asserted-by":"crossref","unstructured":"Poon, C.C.Y., and Zhang, Y.T. (January, January 1). Cuff-less and Non-invasive Measurements of Arterial Blood Pressure by Pulse Transit Time. Proceedings of the 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference, Shanghai, China.","DOI":"10.1109\/IEMBS.2005.1615827"},{"key":"ref_17","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1109\/JBHI.2017.2696703","article-title":"Pulse Transit Time Measurement Using Seismocardiogram, Photoplethysmogram, and Acoustic Recordings: Evaluation and Comparison","volume":"22","author":"Yang","year":"2018","journal-title":"IEEE J. Biomed. Health Inform."},{"key":"ref_18","doi-asserted-by":"crossref","unstructured":"Jiang, X., Shokouhmand, A., Ebadi, N., and Ayazi, F. (2024, January 21\u201325). Fingertip Plethysmography Using a Sensitive Wafer-Level-Packaged Capacitive MEMS Strain Sensor. Proceedings of the 2024 IEEE 37th International Conference on Micro Electro Mechanical Systems (MEMS), Austin, TX, USA.","DOI":"10.1109\/MEMS58180.2024.10439370"},{"key":"ref_19","doi-asserted-by":"crossref","unstructured":"Senturia, S.D. (2001). Structures. Microsystem Design, Springer US.","DOI":"10.1007\/b117574"},{"key":"ref_20","doi-asserted-by":"crossref","first-page":"22527","DOI":"10.1109\/JSEN.2021.3107441","article-title":"A Sawtooth MEMS Capacitive Strain Sensor for Passive Telemetry in Bearings","volume":"21","author":"Zhang","year":"2021","journal-title":"IEEE Sens. J."},{"key":"ref_21","doi-asserted-by":"crossref","first-page":"095003","DOI":"10.1088\/1361-6439\/ad690e","article-title":"Lithographically patternable SU-8\/Graphene nanocomposite based strain sensors for soft-MEMS applications","volume":"34","author":"Beigh","year":"2024","journal-title":"J. Micromech. Microeng."},{"key":"ref_22","doi-asserted-by":"crossref","first-page":"5070","DOI":"10.1039\/D4MH00757C","article-title":"Encapsulated stretchable amphibious strain sensors","volume":"11","author":"Wu","year":"2024","journal-title":"Mater. Horiz."},{"key":"ref_23","doi-asserted-by":"crossref","first-page":"385501","DOI":"10.1088\/1361-6528\/ab9970","article-title":"A highly sensitive wearable flexible strain sensor based on polycrystalline MoS2 thin film","volume":"31","author":"Rana","year":"2020","journal-title":"Nanotechnology"},{"key":"ref_24","doi-asserted-by":"crossref","first-page":"4300","DOI":"10.1109\/JSEN.2019.2961411","article-title":"Blood Pressure Estimation Using Photoplethysmogram Signal and Its Morphological Features","volume":"20","author":"Hasanzadeh","year":"2020","journal-title":"IEEE Sens. J."},{"key":"ref_25","doi-asserted-by":"crossref","unstructured":"Sol\u00e0, J., and Delgado-Gonzalo, R. (2019). The Handbook of Cuffless Blood Pressure Monitoring: A Practical Guide for Clinicians, Researchers, and Engineers, Springer International Publishing.","DOI":"10.1007\/978-3-030-24701-0"},{"key":"ref_26","doi-asserted-by":"crossref","first-page":"7445","DOI":"10.1364\/BOE.439893","article-title":"Monte Carlo analysis of optical heart rate sensors in commercial wearables: The effect of skin tone and obesity on the photoplethysmography (PPG) signal","volume":"12","author":"Ajmal","year":"2021","journal-title":"Biomed. Opt. Express"}],"container-title":["Biosensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.mdpi.com\/2079-6374\/15\/5\/325\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T17:35:29Z","timestamp":1760031329000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.mdpi.com\/2079-6374\/15\/5\/325"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,20]]},"references-count":26,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2025,5]]}},"alternative-id":["bios15050325"],"URL":"https:\/\/doi.org\/10.3390\/bios15050325","relation":{},"ISSN":["2079-6374"],"issn-type":[{"value":"2079-6374","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,20]]}}}